• 제목/요약/키워드: 표면 열유속

검색결과 128건 처리시간 0.026초

수직 동심 환형관 내부유동에서 과냉 유체의 비등 시작 열유속에 관한 표면 볼록 곡률의 영향 (Effect of Convex Surface Curvature on the Onset of Nucleate Boiling of Subcooled Fluid Flow in Vertical Concentric Annuli)

  • 변정환;이승홍
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1513-1520
    • /
    • 2002
  • Effect of Convex Surface Curvature on the Onset of Nucleate Boiling of Subcooled Fluid Flow in Vertical Concentric Annuli An experimental study has been carried out to investigate the effect of the transverse convex surface curvature of core tubes on heat transfer in concentric annular tubes. Water is used as the working fluid. Three annuli having a different radius of the inner cores, Ri=3.18mm, 6.35mm, and 12.70mm with a fixed ratio of Ri/Ro=0.5 are used over a range of the Reynolds number between about 40,000 and 80,000. The inner cores are made of smooth stainless steel tubes and heated electrically to provide constant heat fluxes throughout the whole length of each test section. Experimental result shows that heat flux values on the onset of nucleate boiling of the smaller inner diameter model is much higher than that of the larger size test model.

경사진 튜브 표면의 풀비등 열전달계수 계산을 위한 실험식 개발 (Development of Empirical Correlation to Calculate Pool Boiling Heat Transfer Coefficient on Inclined Tube Surface)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제40권8호
    • /
    • pp.527-533
    • /
    • 2016
  • 대기압 상태인 물의 내부에 설치된 튜브의 경사각이 풀비등 열전달계수에 미치는 영향을 확인하기 위하여 새로운 실험식을 개발하였다. 실험과 기존에 발표된 결과들에 대한 조사를 통하여 431개의 실험값을 결정하였으며, 회귀분석 기법으로 비선형 최소자승법을 사용하였다. 열유속($0{\sim}120kW/m^2$), 경사각($0^{\circ}{\sim}90^{\circ}$), 튜브 길이를 직경으로 나눈 값(18~42.52)을 주요 매개변수로 선정하였다. 새롭게 개발된 상관식은 약간의 예외를 제외하면 실험값을 ${\pm}18%$ 범위 내에서 잘 예측한다.

초크랄스키법에 의한 실리콘 단결정 성장시 축방향 자기장의 영향 (The Effect of an Axial Magnetic Field on Czochralski Growth of Silicon)

  • 정형태;한승호;윤종규
    • 한국결정성장학회지
    • /
    • 제3권1호
    • /
    • pp.1-11
    • /
    • 1993
  • 초크랄스키 법에 의한 실리콘 단결정 성장시 액상내의 난류 특성 억제 및 산소, 첨가제 등의 제어를 위해 보통 자기장을 걸어주고 있으며 본 연구에서는 축방향 자기장을 걸어주었을 경우 나타나는 자장의 효과를 수치적으로 계산하였다. 자기력의 증가에 따라 액상내의 유속의 크기는 상당히 억제되었다. 자장의 크기가 증가함에 따라 중심축 부근에서 상승하는 유동의 속도가 감소하기 때문에 S/L 응고계면은 점점 평탄해졌으며, B=0.3 Tesla에서 액상내의 온도 분포는 중심축 부근을 제외하고는 오직 전호 효과로만 계산된 결과와 거의 유사하였다. 또한 고상 및 액상 표면을 통한 열방출량 중 Ar 가스에 의한 열방출량은 3% 미만이었으며 대부분의 열량은 복사를 통해 방출되었다.

  • PDF

집광 열유속 측정과 모델링의 비교를 통한 집광 오차 평가 (Concentration Error Assessment by Comparison of Solar Flux Measurement and Modeling)

  • 채관교;윤환기;이현진;이성욱;김시석
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.82-90
    • /
    • 2013
  • Concentration errors critically affect the performance of solar concentrator, so their evaluation is important to the concentrated solar power technology. However, the evaluation is very challenging because error sources are various and not easy to measure individually. Therefore, the integrated effect of concentration errors is often more interesting and useful for large-scale applications. In the present work, we analytically investigate and classify various concentration error sources and then explain that the effect of various concentration errors can be represented in terms of a root mean square value of reflector surface slope error. We present an indirect approach to assessing the reflector surface slope error by comparing solar flux measurement data with modeling calculations. We apply the approach for solar furnaces with different thermal capacity and investigate its advantages and disadvantages.

마이크로다공성 발열체 표면에서의 액체분무 냉각성능 특성 (Characteristics on Spray Cooling Performance on the Micro-Porous Coated Surfaces)

  • 김윤호;최치환;이규정
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.304-311
    • /
    • 2006
  • Experiments on evaporative spray cooling on the square plate heaters with plain or micro-porous coated surfaces were performed in this study. Micro-porous coated surfaces were made by using DOM [Diamond particle, Omegabond 101, Methyl-Ethyl-Keton] method. In case of purely air-jet cooling, the micro-porous coating doesn't affect the cooling capacity. In spray cooling three different flow patterns (complete wetting, evaporative wetting, dryout) are observed on both plain and micro-porous coated surfaces. The effects of various operating conditions, such as water flow rate, particle size, and coating thickness were investigated on the micro-porous coated surfaces. It is found that the level of surface wetting is an important factor to determine the performance of spray cooling. It depends on the balance between absorbed liquid amount by capillary force over porosity and the evaporative amount. The micro-porous coated surface has largest cooling capacity, especially in the evaporative wetting zone. It is found that the effects of liquid flow rate and coating thickness are significant in evaporative wetting zone, but are not in complete wetting and dryout zones.

모의 생체조직의 표면온도 조건에 따른 근육이완 특성에 관한 연구 (A Study on the Characteristics of Muscle Relaxation according to the Temperature Condition at the Surface of Imitational Biological Tissue)

  • 고동국;이찬우;김민수
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.770-775
    • /
    • 2018
  • In this study, the characteristics of muscle relaxation were analyzed by the experimental and numerical method. A skin tissue was produced by imitational biological tissue using the agar powder, saline solution and sugar. The tissue was exposed to three types of wavelength-blue visible radiation(410 nm), red visible radiation(635 nm), and infrared ray(830 nm). The temperature results along the depth of tissue were measured according to the variation of light wavelength and irradiation time. The temperature change of the tissue shown up similar pattern regardless of the light wavelength kinds. The wavelength of infrared ray penetrated strongly into tissue between 3.2 mm and 11.4 mm. Also, the temperature change with the irradiation time was small, and the temperature value of the infrared ray was the largest. As a result, the muscle relaxation will occur mainly at the infrared wavelength.

열회수장치의 열교환 파이프형식별 열교환 성능 비교 (Comparison of Heat Exchanging Performances Depending on Different Heat Exchanging Pipe Arrangement)

  • 서원명;윤용철;강종국;김정섭
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 2001년도 봄 학술발표논문집
    • /
    • pp.100-102
    • /
    • 2001
  • 본 연구에서는 온실의 난방에 사용되는 열풍식 난방기 등의 배기 연통에 부착하여 배출되는 가스로부터 열을 회수할 수 있는 장치를 개발함에 있어서 연통과 열회수 장치간의 열 교환 성능을 3가지 상이하게 설계된 열 교환 장치(Fig. 1 참조)에 대하여 실험적으로 비교 분석하였다. Fig. 1-(a)는 열 교회수기 개발을 위해 기존에 사용한 장치로서 회수용 공기의 흐름방향이 배기 연통과 직각을 이룬 형식이며, Fig. 1-(b) 및 (c)는 열 회수 성능 개선을 위해 새로 설계된 형식으로서 각각 열 교환 파이프의 배치형식이 상이하나 회수용 공기의 흐름방향이 180도로 굴곡되는 U-자형 흐름이 이루어지도록 하였다. 실험에 사용된 공기 순환 펜의 용량은 AB-형의 경우에는 최대 25㎥/min이고, C-형 및 D-형의 경우는 공히 최대 42㎥/min으로서 송풍전압 조절장치를 이용하여 풍량을 연속적으로 조절할 수 있도록 하였다. U-자형 흐름형식인 C-형 및 D-형의 경우 흐름 방향의 굴곡으로 인한 마찰저항이 있을 것으로 예상은 했으나 당초 예상했던 것에 비해 마찰 저항이 지나치게 큰 것으로 밝혀졌다. 비록 설계된 열교환 튜브의 배열형식별 열 교환기의 외부 모양이 달라 회수기의 표면을 통한 대류 열 교환이 다소 차이를 보일 것으로 예상되지만 본 연구에서는 열 회수장치에 내장된 열 교환 튜브부분만을 통한 열 회수율을 중심으로 형식간의 성능을 비교하였다. 실험을 통하여 측정된 자료중 대표적인 예는 Fig-2와 같으며, 측정자료를 기준으로 분석된 열회수 성능에 대한 설계형식별 비교 결과는 Table-1과 같으며, 분석된 결과를 요약하면 다음과 같다: 1. AB-형 열회수시스템의 경우, 초기 투자비용과 현재의 농용 전력요금 하에서 에너지 절감규모를 비교하면, 대체로 1년을 전후하여 투자에 대한 보상이 충분히 가능할 것으로 판단된다. 2. C-형 및 D-형 열회수시스템의 경우, 열 회수용 공기의 흐름방향이 동일 공간내에서 180도 굴절됨으로서 저항이 크게 발생되어 송풍 펜의 전압 증가에 따른 유속증가가 미미하였으며, 굴절형의 열교환장치는 비록 열교환면적은 직선형과 유사하더라도 송풍 펜의 공기저항이 커져서 결국 열 회수성능이 기대했던 것만큼 크게 개선되지는 못했다. 3. 송풍펜의 용량은 AB-형에 사용된 용량인 25㎥/min 전후가 적절할 것으로 판단되며, 적정 송풍 펜용량 하에서 열 회수성능은 굴절형이 직선형보다 효과적인 것으로 나타났다. 다만, 곡선형은 물론 직선형에서도 열교환 튜브의 배치밀도, 튜브 길이 및 두께 등의 변화에 따른 최적화 연구가 수반되어야 할 것으로 판단된다.

  • PDF

핵연료 크러드가 원전 재관수 열전달에 미치는 영향 (Effects of Crud on reflood heat transfer in Nuclear Power Plant)

  • 유진;김병재
    • 한국산학기술학회논문지
    • /
    • 제22권5호
    • /
    • pp.554-560
    • /
    • 2021
  • 크러드는 원자력 발전소 운전 시 핵연료 표면에 침적되는 철-니켈-크롬 등의 금속 산화물로 이루어진 다공성 물질이다. 그 두께는 수십 ㎛ 수준이다. 발전소의 냉각재상실사고 시 크러드 층은 핵연료-냉각수 열전달에 영향을 미치게 되어 원전 안전성 측면에서 그 영향을 살펴보는 것이 중요하다. 일반적으로 크러드는 열저항으로 인하여 핵연료 온도를 높이는 부정적 효과가 있는 것으로 알려져 있었다. 그 이유는 크러드에 의하여 핵비등, 최소막비등온도, 단상증기 열전달, 임계열유속, 막비등 열전달 등 2상유동 열전달 특성을 고려하지 않았기 때문이다. 본 연구에서는 다공성 크러드 물질의 물성치를 모델링하고 이를 국내 원전안전해석 코드인 SPACE에 탑재하였다. 크러드는 다공성 고체 물질이고 표면이 거칠기 때문에 최소막비등온도와 단상증기 열전달이 증가할 것으로 예상된다. 이에 최소막비등온도와 단상증기 열전달이 최대 피복재 온도 및 급냉에 미치는 영향을 평가하였다. 시험 계산은 기존 FLECHT-SEASET 재관수 실험 장치에 기반으로 수행되었다. 계산결과 최소막비등온도가 상승하여 급냉시간이 줄어들었다. 단상증기 열전달의 경우 약 20% 증가할 때까지는 최대 피복재 온도가 하강하였다. 크러드 층이 원전 안정성 측면에서 긍정적인 효과가 있음을 확인하였다.

마이크로 핀 표면 핵비등에서의 기포거동에 대한 수치적 연구 (Numerical Study of Bubble Motion During Nucleate Boiling on a Micro-Finned Surface)

  • 이우림;손기헌
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1089-1095
    • /
    • 2011
  • 열전달 향상을 위한 방법으로 많이 사용되고 있는 마이크로 핀을 포함한 표면 위에서의 핵비등을 액상과 기상에서 질량 및 운동량, 에너지에 대한 지배 방정식을 풀어 수치해석을 수행하였다. 핵비등에서의 기포거동을 계산하기 위해 sharp-interface 레벨셋(level-set) 방법을 상변화 효과와 핀과 캐비티와 같은 잠긴 고체에서의 점착 조건 및 접촉각, 마이크로 액체층에서의 증발 열유속을 포함하도록 수정하였다. 핀과 캐비티를 포함한 표면에서의 기포 생성, 성장, 이탈에 대한 해석을 통하여 핀-캐비티 배열, 핀-핀 간격이 핵비등에서의 기포거동에 중요한 역할을 하는 것을 확인하였다.

냉동저장 공동 주변의 온도분포 예측을 위한 해석해 및 수치모델 적용에 관한 연구 (Analytical and Numerical Model Study to Predict the Temperature Distribution Around an Underground Food Cold Storage Pilot Cavern)

  • 이대혁;김호영
    • 터널과지하공간
    • /
    • 제12권3호
    • /
    • pp.142-151
    • /
    • 2002
  • 대전 식품냉동저장창고 파일럿 공동주위의 거리에 따른 비정상상태의 온도 분포를 산정하기 위해 Claesson(2001)의 해석해 및 Dirichlet과 Neuman 내부 경계조건을 갖는 수치모델들을 검토하였다. 온도 강하 단계동안 일정 표면 온도 경계조건에 기초하고 있는 Claesson의 해석해를 활용한 결과, 실제 암반에서의 온도 계측결과를 오차 평균 0.89$^{\circ}C$ 수준으로서 비교적 정확히 예측할 수 있었는데, $0^{\circ}C$근처의 실험실 암석 열물성을 입력하였고 현지 암반 조건을 표현하기 위한 특별한 물성 보정을 하지 않았다. 내부 공동 암반 벽면을 통한 열유속을 갖는 수치해석의 경우, 대류 열전달계수와 공동 내부 온도가 냉각시간에 따라 변화하기 때문에 경계조건을 가하기 어려운 단점을 극복하기 위해 새로운 경계조건 설정 기법을 제안하였다. 그 결과 오차 평균 1.58$^{\circ}C$의 수준으로서 온도 계측치와 부합하였다. 또한 공동 벽면에서 고정 온도 조건을 갖는 수치해와 비교하였다. 마지막으로 Claesson의 해석해 및 다양한 내부 경계조건을 갖는 수치모델을 활용하여, 공동 주변의 온도 분포를 정확히 예측할 수 있는 일련의 해석 단계 프로그램을 제안하였다.