• Title/Summary/Keyword: 통계적 일치

Search Result 206, Processing Time 0.031 seconds

Measurement of Horizontal and Vertical Prism Diopter According to Difference between the Optical Center and Pupil Center (안경 광학중심과 동공중심의 불일치에 의한 수평, 수직 유발프리즘의 측정)

  • Kim, Hyojin;Park, Jee-Hyun;Park, Seon-A;Baek, Ji-Seon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Measurement of the horizontal and vertical prism diopter was investigated which was occurred due to distance differences between the optical inter-centeral distance (OC) and the interpupillary distance (PD) of the prescribed glasses. Methods: We surveyed 96 subjects (192 eyes) at the average age of 21.56 years old. The PD was measured by using the PD measurement system (DONGYANG PD-85, Korea), and the OC of the glasses was measured by using the projective peak refractive power measurement system (TOPCON CL-200, Japan). The OH value was measured by using Penlight and the PD ruler. Results: The PD which had been measured by the PD system and the OC of the glasses revealed 78.1% of differences. 62.5% of the objects were base-in value prescribed glasses; 58.3% were out of permissible error. Only 8 subject showed concurrence between the prescribed glasses and the OH value, and 82.3% of the objects were induced vertical prism of over 1 (prism diopter). Conclusions: In order to improve the vision function of people who wear glasses, it is necessary to advance the accuracy of PD, OH measurement and making glasses as well.

Forest Vegetation Structure in Maruguem (the Ridge Line) Area of Gitdaebaegibong to Jukryeong, Baekdudaegan (백두대간(깃대배기봉-죽령 구간) 마루금 주변의 산림식생구조)

  • Song, Ju Hyeon;Yun, Chung Weon
    • Journal of Korean Society of Forest Science
    • /
    • v.108 no.2
    • /
    • pp.147-167
    • /
    • 2019
  • This study was conducted to analyze forest vegetation structure in the Marugeum (Ridge) area of Gitdaebaegibong to Jukryeong, Baekdudaegan. Data were collected in 298 quadrates through a Braun-Blanquet vegetation survey from April, 2018 to October, 2018. Forest vegetation was classified into 13 vegetation units. A Quercus mongolica community was divided into Morus bombycis, Filipendula glaberrima, Fraxinus sieboldiana, Prunus maackii unit and Q. mongolica typical unit. The M. bombycis unit was further classified into a Deutzia glabrata group and M. bombycis typical group. The F. glaberrima unit was subdivided into a Veratrum oxysepalum group, Arundinella hirta group, and F. glaberrima typical group. The F. sieboldiana unit was divided into a Pinus densiflora group, Larix kaempferi group, and F. sieboliana typical group. The relationship between vegetation units and environmental factors was studied through coincidence analysis and CCA. The F. glaberrima unit (VU 6~8) was distributed by elevation above 1,200 m and other vegetation units were distributed below 1,200 m. Results of the CCA analysis showed that the F. glaberrima unit distribution is positively correlated with elevation. As a result of species diversity, the F. glaberrima unit was higher than other vegetation units. A similarity index analysis revealed that the F. sieboldiana unit (VU 9~11) was relatively homogeneous, and the M. bombycis unit (VU 1~5) and A. girta group (VU 7) were relatively heterogeneous. A detrended correspondence analysis determined that the distance between the statistical axes of the M. bombycis and F. glaberrima units was the greatest, which is consistent with the analysis of the similarity index. As a result of interspecific correlation of major woody plants, hydrophilic species were positively correlated, and a negative correlation was found between Q. mongolica and intolerant species such as P. densiflora and L. kaempferi.

The Utility of Chest CT in Staging of Esophageal Cancer (식도암의 병기 결정에 있어 흉부 CT의 유용성)

  • 홍성범;장원채;김윤현;김병표;최용선;오봉석
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.992-998
    • /
    • 2004
  • Background: The decision of staging of esophageal cancer have great effect on the resectability of the lesion and estimation of the patient's prognosis. Today, CT is one of the most popular modality for staging of esophageal cancer. However, it has some limitations because of false-positive or false-negative findings on cancer staging. The purpose of this study was to analyze the efficacy of CT in preoperative staging of esophageal cancer. Material and Method: We retrospectively analysed the difference of staging of esophageal cancer between CT and histopathological findings for the 114 patients with histologically proven esophageal cancer who underwent operation at the department of thoracic and cardiovascular surgery, Chonnam national university hospital, between January 1999 and June 2003. We evaluated the efficacy of chest CT in the staging of esophageal cancer compared to postoperative histopathologic findings by calculating sensitivity, specificity, accuracy, and reproducibility of chest CT to detect abnormality. Result: The reproducibilities between chest CT and histopathologic findings were 0.32 (p<0.01) for primary tumor (T), 0.36 (p<0.01) for lymph node invasion (N), and 0.62 (p<0.01) for distant metastasis (M). The reproducibilities between chest CT and histopathologic findings for lymph node invasion (N) and distant metastasis (M) were superior to that of primary tumor (T). The accuracy of primary tumor (T) was 65.8% and 98.2% in group III and IV, which was significantly higher than that of group I and II (78.9% and 62.3%). In general, specificity of chest CT for TNM staging was superior to sensitivity. Conclusion: In conclusion, preoperative CT scanning can provide important information on lymph node invasion and metastasis of lesion than primary tumor invasion.

The Rate of Diagnostic Agreement and Concordance Ratings on Psychiatric Recommendation in Consulted Delirious Cases (자문의뢰된 섬망환자에 대한 진단 일치율과 정신과 의견의 반영도)

  • Oh, Eung-Seok;Nam, Jung-Hyun;Kim, Seok-Hyeon;Park, Yong-Chon;Kim, Sung-Mok
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.9 no.2
    • /
    • pp.174-181
    • /
    • 2001
  • Objectives : The author investigated the rate of diagnostic agreement between consultants and consultees and concordance ratings on the consultees' recommendation to examine the interactive collaborativeness and find the factors that influence the reflectiveness on treatment. Methods : The subjects were 54 patients with delirium selected from 583 cases referred from other departments who were admitted to Hanyang University Kuri Hospital from July 1, 1995 to Dec. 31, 1997. The information on demographic data, diagnostic impression, symptoms, management before consultation, psychiatric recommendation, management after consultation, diagnoses at the referring departments and the psychiatric department on delirium was obtained by medical records and consultation papers retrospectively. The reflectiveness of the psychiatric recommendation was divided into complete concordance, partial concordance, and nonconcordance and among them the complete and partial concordance were considered for concordance. The reflectiveness was compared among all the departments and between medical unit and surgery unit. Results: The rate of diagnostic agreement on the cause of delirium was highest(85.7%) in organic brain syndrome and lowest in general medical condition(0%). There was no statistically significant differences between medical unit and surgery unit. Neither differences were there among all the departments. In comparing symptoms affecting the reflectiveness, it was 73.5% in impulsive and aggressive behavioral changes, whereas 40.0% in behavioral changes. Reflectiveness of psychiatric recommendation showed higher scores in the case of behavioral changes. The cases of sleep problem showed higher scores of reflectiveness. When these two symptoms of behavioral change and sleep problem were compared as one factor, the results suggested that there were significant differences. The cases with both two symptoms showed 80% in reflectiveness, and the cases with only one symptom or no symptoms showed 44.8% in reflectiveness. There were no statistical significances between concordance ratings and symptoms such as disturbance of consciousness, disorientation, and hallucination that cannot be easily evaluated at the referring departments. Conclusions : The rate of diagnostic agreement on the cause of delirium was highest in the case of organic brain syndrome in which lesions can be easily recognized. The factors that influence the reflectiveness of psychiatric recommendation were behavior changes and sleep disorders in the symptoms of evaluated cases.

  • PDF

Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization (경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가)

  • Min Jae Gu;Jae Hyuck Yi;Young Hwan Kim;Hee Jung Lee;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.166-175
    • /
    • 2020
  • Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320.

Accuracy of bite registration according to the buccal bite scan range of intra-oral scanner (구강 스캐너의 협측 교합 스캔 부위에 따른 교합 인기의 정확도)

  • Tae-sung Kwon;Dae-hyun Kim;Min-su Kim;Dong-jun Song;Joo-Hun Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.125-134
    • /
    • 2024
  • Purpose: The aim of this study was to determine which scan range would provide the most accurate bite registration when performing a bite scan after scanning an upper and lower arch using an intraoral scanner. Materials and Methods: The occlusal contact points were recorded using articulating paper for 30 adults, and the results of various ranges of buccal bite scan were compared based on this. Buccal bite scan of 5 ranges (1st premolar to 2nd premolar, 1st premolar to 1st molar, 1st premolar to 2nd molar, 2nd premolar to 1st molar, and canines to another side canine of the maxillary teeth) was performed, and then the buccal bite scan file was used in a CAD program to confirm the occlusal area in the scan file through data editing and alignment, leaving the buccal area of the teeth. Afterwards, the degree of agreement between the occlusal contact points obtained from the articulating paper and the occlusal area obtained from the scan file was compared, and statistical analysis was performed using the homoscedastic T-test (α = 0.05). Results: The alignment success and alignment failure rates among each group were 77.23% and 40.85% in canine to another side canine, 68.23% and 28.89% in bilateral first premolar to second premolar, 63.76% and 29.97% in bilateral first premolar to first molar, 61.31% and 32.04% in bilateral first premolar to second molar, 67.55% and 27.46% in second premolar to first molar. The results of the anterior scan of both canines showed higher alignment success and failure rates compared to the scan results of all maxillary posterior teeth. In the alignment success rate, statistical significance was not found depending on the scan range of the posterior teeth, but in comparing the results of the posterior teeth and both canines, statistical significance was observed except for the scan results of the second premolar to the first molar. There was no statistical significance in the alignment failure rate depending on the scan range of the posterior teeth, and statistical significance was observed in the results of the posterior teeth and both canines. Conclusion: When taking a buccal bite scan, in the case of scanning the anterior teeth, more occlusal area appear than when scanning the posterior teeth, and in the case of scanning the posterior teeth, there is no significant difference in the bite registration depending on the scan range.

Statistical Characteristics of Hourly Tidal Levels around the Korean Peninsula (한반도 연안 1시간 조위자료의 통계적 특성)

  • Ko, Dong Hui;Jeong, Shin Taek;Cho, Hongyeon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.6
    • /
    • pp.365-373
    • /
    • 2013
  • Representative tidal gauging (TG) stations are selected to cover the tidal characteristics of the Korean peninsula coastal seas, and the statistical parameters of the data are analysed from the perspective of the probability distribution at that TG station. The shape of the distribution in the Incheon and Gunsan TG stations, which are tide-dominated areas, shows two clear modes at HWONT and LWONT in the distributions, and in the Mokpo station, shows an asymmetric double peak distribution. In contrast, the frequency distribution shape shows a smoothed flat peak in the Jeju, Yeosu and Busan TG stations, and a single peak in the Pohang and Sokcho TG stations. The emersion and submersion equations suggested as the 6-parameter Gaussian mixture models in this study are accurate, and well fitted to the observed tidal elevation data. The ${\mu}_1$, ${\mu}_2$ parameters are highly correlated to the LWONT and HWONT, and the ${\sigma}_1$ and ${\sigma}_2$ parameters are also closely correlated to the mean tidal range. The ${\mu}_1$ and ${\mu}_2$ parameters coincide with the modes of the suggested probability distribution of the hourly tidal level data.

A Nuclide Transport Model in the Fractured Rock Medium Using a Continuous Time Markov Process (연속시간 마코프 프로세스를 이용한 균열암반매질에서의 핵종이동 모델)

  • Lee, Y.M.;Kang, C.H.;Hahn, P.S.;Park, H.H.;Lee, K.J.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.529-538
    • /
    • 1993
  • A stochastic way using continuous time Markov process is presented to model the one-dimensional nuclide transport in fractured rock matrix as an extended study for previous work [1]. A nuclide migration model by the continuous time Markov process for single planar fractured rock matrix, which is considered as a transient system where a process by which the nuclide is diffused into the rock matrix from the fracture may be no more time homogeneous, is compared with a conventional deterministic analytical solution. The primary desired quantities from a stochastic model are the expected values and variance of the state variables as a function of time. The time-dependent probability distributions of nuclides are presented for each discretized compartment of the medium given intensities of transition. Since this model is discrete in medium space, parameters which affect nuclide transport could be easily incorporated for such heterogeneous media as the fractured rock matrix and the layered porous media. Even though the model developed in this study was shown to be sensitive to the number of discretized compartment showing numerical dispersion as the number of compartments are decreased, with small compensating of dispersion coefficient, the model agrees well to analytical solution.

  • PDF

Comparison of Regional Myocardial Perfusion, Left Ventricular Volume and Ejection Fraction between 8- and 16-Frame Gated SPECT (8-단위영상과 16-단위영상으로 얻은 게이트 심근관류 스펙트에서 국소 심근관류, 좌심실 용적과 구혈률의 비교)

  • Lee, Sang-Woo;Lee, Jae-Tae;Bae, Jin-Ho;Jeong, Shin-Young;Chun, Kyung-Ah;Ha, Jeoung-Hee;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.269-277
    • /
    • 2003
  • 목적: 게이트 심근관류 스펙트는 심근의 관류와 좌심실 기능을 동시에 평가할 수 있는 유용한 방법이다. 현재, 게이트 영상 획득시 8 단위영상이 널리 사용되지만, 아직 가장 적절한 단위영상의 수에 대해서는 논의의 여지가 있다. 본 연구는 동일한 환자에서 8 단위영상과 16 단위영상으로 게이트 심근관류 스펙트를 2회 연속적으로 시행하여 국소적 심근관류, 좌심실 용적과 구혈률등을 비교하였다. 대상 및 방법: 42명(평균 연령: 55세, 남: 녀=26: 16)의 관상동맥 질환이 의심되거나 알려진 환자를 대상으로 안정시 Tc-99m MIBI를 이용한 게이트 스펙트를 8 단위영상과 16 단위영상으로 2회 연속하여 시행하였다. 좌심실의 확장기말 용적, 수축기말 용적과 구혈률을 각각 얻었으며 확장기말의 단층영상을 18 분절로 나누고 각 분절마다 심근의 관류정도를 4등급으로 나누어 국소적 심근관류를 평가하였다. 결과: 8 단위영상과 16 단위영상 게이트 스펙트에서 국소적 심근관류의 일치도는 85.7% (tau-b=0.786, p<0.001)로 우수하였다. 두 방법간에 1등급의 차이는 100 분절(13.2%), 2등급 차이는 8 분절(1.1 %)이 있었고 3등급 차이는 없었다. 좌심실의 확장기말 용적, 수축기말 용적, 구혈률은 두 방법간에 높은 상관성을 보였으며(r=0.993, 0.989, 0.935), 좌심실 구혈률은 8 단위영상을 사용할 때 평균 1.8% 낮게 측정되어 통계적인 유의성은 있었으나(p<0.05), 그 차이는 크지 않았다. 결론: 8 단위영상과 16 단위영상을 사용한 게이트 심근관류 스펙트에서 국소적 심근관류의 일치도는 우수하였으며, 좌심실의 기능적 계수의 차이도 크지 않았다. 비록 높은 단위영상을 사용했을 때 더 정확하고 자세한 정보를 얻을 수 있다 하더라도, 구혈률과 용적 등을 얻는 일상적인 임상검사에는 8 단위영상 또한 그 역할을 충분히 할 수 있을 것으로 사료된다.

Modeling of Effective Path-Length in Satellite Link Based on Rain Cell Statistics (위성 링크에 대한 강우셀 기반 실효 경로 길이 모델링 연구)

  • Kang, Woo-Geun;Kim, Myunghoi;Kim, In-Kyum;Choi, Kyung-Soo;Lee, Byoung-Sun;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.348-356
    • /
    • 2014
  • The existing effective path-length model of ITU-R has some drawbacks: The prediction error is quite large compared to domestic measurement data and it is an empirical model in which the physical characteristics of rain cells are not considered. In this paper, a theoretical model for effective path-length using the rain-cell concept was proposed and its validity was verified using the measurement data. To analyze the statistical characteristics of rain cell parameters, the weather-radar data(CAPPI) measured by Korea Meterological Administration were analyzed and the correction factor was properly introduced to fit the Chollian beacon measurement data of ETRI(Electronics and Telecommunications Research Institute). To verify the proposed effective path-length model, it was compared with the Mugunghwa No. 5 beacon data measured in Chungnam National University with the support of ADD(Agency for Defense Development). It was confirmed that the prediction results of the proposed model are in good agreement with the measurement data.