Comparison of Regional Myocardial Perfusion, Left Ventricular Volume and Ejection Fraction between 8- and 16-Frame Gated SPECT
![]() |
Lee, Sang-Woo
(Department of Nuclear Medicine, Kyungpook National University School of Medicine)
Lee, Jae-Tae (Department of Nuclear Medicine, Kyungpook National University School of Medicine) Bae, Jin-Ho (Department of Nuclear Medicine, Kyungpook National University School of Medicine) Jeong, Shin-Young (Department of Nuclear Medicine, Kyungpook National University School of Medicine) Chun, Kyung-Ah (Department of Nuclear Medicine, Kyungpook National University School of Medicine) Ha, Jeoung-Hee (Department of Nuclear Medicine, Kyungpook National University School of Medicine) Ahn, Byeong-Cheol (Department of Nuclear Medicine, Kyungpook National University School of Medicine) Lee, Kyu-Bo (Department of Nuclear Medicine, Kyungpook National University School of Medicine) |
1 | Brown KA. Prognostic value of thallium-201 myocardial perfusion imaging: a diagnostic tool comes of age. Circulation 1991;83: 363-81 DOI PUBMED ScienceOn |
2 | Brown KA. Prognostic value of myocardial perfusion imaging: State of the art and new developments. J Nucl Cardiol 1996;3: 516-37 DOI ScienceOn |
3 | Berman DS, Germano G. Evaluation of ventricular ejection fraction, wall motion, wall thickening, and other parameters with gated myocardial perfusion single-photon emission computed tomography. J Nucl Cardiol 1997;4: S169-71 DOI ScienceOn |
4 | Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995;36: 2138-47 PUBMED |
5 |
Manrique A, Faraggi M, Vera P, Vilain D, Lebtahi R, Cribier A, et al. |
6 | Keng F, Chandwaney R, Mahmarian J, Verani M. Accuracy of gated-SPECT imaging in diagnosing individual coronary artery stenosis: A comparison between ungated and gated images. J Nucl Cardiol 1999;6(suppl): S16 |
7 | Taillefer R, DePuey EG, Udelson JE, Beller GA, Benjamin C, Gagnon A. Comparison between the end-diastolic images and the summed images of gated 99mTc-sestamibi SPECT perfusion study in detection of coronary artery disease in women. J Nucl Cardiol 1999;6: 169-76 DOI ScienceOn |
8 | Germano G, Berman DS. On the accuracy and reproducibility of quantitative gated myocardial perfusion SPECT. J Nucl Med 1999;40: 810-3 PUBMED |
9 | Cullom SJ, Case JA, Bateman TM. Electrocardiographically gated myocardial perfusion SPECT: Technical principles and quality control considerations. J Nucl Cardiol 1998;5: 418-25 DOI ScienceOn |
10 | Kikkawa M, Nakamura T, Sakamoto K, Sugihara H, Azuma A, Sawada T, et al. Assessment of left ventricular diastolic function from quantitative electrocardiographic-gated 99mTc-tetrofosmin myo cardial SPET. Eur J Nucl Med 2001;28: 593-601 DOI ScienceOn |
11 | Manrique A, Koning R, Cribier A, Vera P. Effect of temporal sampling on evaluation of left ventricular ejection fraction by means of thallium-201 gated SPET: comparison of 16-and 8-interval gating, with reference to equilibrium radionuclide angiography. Eur J Nucl Med 2000;27: 694-9 DOI ScienceOn |
12 | Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1: 307-10 PUBMED |
13 | The Multicenter Postinfarction Research Group. Risk stratification and survival after myocardial infarction. N Engl J Med 1983;309: 331-6 DOI ScienceOn |
14 | Simoons ML, Vos J, Tijssen JG, Vermeer F, Verheugt FW, Krauss XH, et al. Long-term benefit of early thrombolytic therapy in patients with acute myocardial infarction: 5 year follow-up of a trial conducted by the Interuniversity Cardiology Institute of The Netherlands. J Am Coll Cardiol 1989;14: 1609-15 DOI PUBMED |
15 | Kumita S, Cho K, Nakajo H, Toba M, Uwamori M, Mizumura S, et al. Assessment of left ventricular diastolic function with electrocardiography-gated myocardial perfusion SPECT: comparison with multigated equilibrium radionuclide angiography. J Nucl Cardiol 2001;8: 568-74 DOI ScienceOn |
16 | Imai K, Azuma Y, Nakajima T, Yamazaki S, Iwano K, Hayafune N, et al. Frames a cardiac cycle in quantitative gated SPECT (QGS) for clinical use: 8 versus 16 . J Nucl Cardiol 1999;6(suppl): S17 |
![]() |