• Title/Summary/Keyword: 콘크리트 열화

Search Result 428, Processing Time 0.026 seconds

Surface Characteristics of Concrete According to Types of Formworks (거푸집 종류에 따른 콘크리트 표면 특성)

  • Park, Se-Eon;Choi, Jeong-Il;Lee, Bong-Kee;Lee, Bang Yeon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.499-505
    • /
    • 2021
  • The purpose of this study is to investigate experimentally the physical/chemical properties of concrete surface according to types of formworks. Plywood formwork and coated plywood formwork were prepared. In addition, plywood formwork with sand paper was prepared to simulate deterioration of concrete or rough surface of concrete. Normal concrete was used in this study. The properties of concrete surface were investigated by visual inspection, scanning electron microscopy and energy-dispersive X-ray spectroscopy techniques, elemental mapping, 2D and 3D surface profile measurement, and zeta potential measurement. Test results showed that concrete in a coated formwork had smooth surface and concrete in the formwork with sand paper had rough surface. It was observed that properties of concrete surface depended on types of formworks. Furthermore, differences in surface roughness were significantly higher than those in chemical compositions and zeta potential.

The Evaluation of Surface Scaling and Resistance of Concrete to Frost Deterioration with Freezing-Thawing Action by Salt Water (염화물이 함유된 동결수의 동결융해 작용에 따른 콘크리트의 내동해성과 표면열화 평가)

  • Kim, Gyu-Yong;Kim, Moo-Han;Cho, Bong-Suk;Lee, Seung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.143-151
    • /
    • 2007
  • This study presents the experimental results of frost durability including resistance to freezing-thawing and surface scaling of concrete. Mixing design was proportioned with the various water-binder ratio between 0.37 and 0.47 and three different binder compositions corresponding to Type I cement without any supplementary cementitious materials(OPC), Type II cement with 50% blast-furnace slag replacement(BFS50), and ternary cement with Type III cement, 15% fly ash, and 35% slag replacement (BFS35%+FA15%). Test results showed that the mixing design with BFS50% and BFS35%+FA15% exhibited higher durability factor than that made with OPC only. Finally, the use of blend cement containing slag can be used effectively in terms of frost durability of the concrete exposed to severe condition under coastal environment like as flying salt, sea water spray, etc.

Durability of glass fiber under the alkali environment (알카리 환경하에서 유리섬유의 내구성)

  • Kim, T.J.;Kim, K.S.;Choi, L.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.204-209
    • /
    • 1999
  • 각종섬유를 연속섬유 보강재로 사용하는 경우, 일반적으로 수지를 매트릭스로 하여 봉재 형상(FRP rod)으로 제조하고있다. 성형된 섬유는 수지가 섬유의 보호재 역할을 하기 때문에, 콘크리트내의 알칼리와 절연되어 열화가능성이 작다고 고려된다. 그러나, 일반적으로 섬유를 둘러싼 수지는 그 두께가 수 {$mu}m$이하로 특히 얇고, 운반이나 보관시에 수지가 물리적 변형 및 자외선에 의한 열화가 일어날 가능성이 높다. 또 알칼리에 의하여 에스테르의 가수분해반응에 따른 폴리머의 부식 등, 수지에 알칼리의 침입을 완전히 막는 것이 불가능하게 여겨진다.

  • PDF

A Study on the Analysis of 3 Dimensional Substrate Behaviour of Complex Environmental Deterioration and the Analysis of Results (복합열화분석용 3차원 거동대응성 시험을 통한 결과분석)

  • Song, Je-Young;Seo, Hyun-Jae;Kim, Bum-Soo;Choi, Eun-Kyu;Lee, Jung-Hun;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.219-220
    • /
    • 2017
  • Current domestic waterproofing market in Korea mainly uses single-ply waterproofing materials comprised of coatings or waterproof sheets and two or more-ply composite waterproofing methods. In order to evaluate these types of composite waterproofing systems, a new test equipment and method that incorporates various deterioration conditions (joint displacement, chemical exposure, water pressure etc) was developed. In a comparison testing, the results showed that flexible type materials have higher response performance towards joint displacement than the hardened material. Furthermore, the importance of securing the stability of the waterproofing method in the vulnerable over-lap joint areas of waterproofing sheets is emphasized.

  • PDF

The Proposal of Efficient Inspection for Concrete Bridge Decks has Asphalt Overlay (교면포장을 갖는 교량 바닥판의 효율적인 점검방법 제안)

  • Suh, Jin-Won;Rhee, Ji-Young;Ku, Bon-Sung;Park, Chang-Ho;Shin, Jae-In
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.157-160
    • /
    • 2008
  • Bridge decks are directly exposed to traffic loads and environmental conditions like rainfall water and de-icing chemicals. In this reason, there are often observed the deteriorations of asphalt overlay and concrete deck. In this study, 32 concrete decks were evaluated by the road inspection vehicle and the GPR mounted on the vehicle. The GPR could detect the deteriorations of concrete decks under asphalt overlay, even though the asphalt overlay looks like soundness. Therefore, for the efficient maintenance of concrete bridge decks, GPR examination should be performed with visual inspection.

  • PDF

Reduction of Drying Shrinkage of Mortar and Concrete by Expansion of Rapid Cooling Slag Fine Aggregate (급냉 슬래그 잔골재의 팽창성을 활용한 모르타르 및 콘크리트의 건조수축저감에 관한 연구)

  • Lee, Dong-Gyu;Min, Kyung-Hwan;Jeong, Yong-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3511-3517
    • /
    • 2015
  • It is necessary to maximize the durability of Concrete for the underground structure because its maintenance and reinforcement are difficult. For cracks due to drying shrinkage of the concrete on the characteristics of the material, there is a need for an alternative in the deterioration phenomenon that occurs. In this study, fundamental properties including drying shrinkage of mortar and concrete were investigated to replace fine aggregate from cooling slag for reducing drying shrinkage of mortar and concrete. In the case of rapid cooling slag fine aggregate, it was effective to reduce and restrain initial shrinkage of mortar and concrete, and compressive strength was increased through the all specimen in proportion to its replacement ratio.

The Evaluation of Mechanical Properties of Ultra High Performance Concrete with Using Steel Fiber of Wave Type (물결형 강섬유를 이용한 초고성능 콘크리트의 역학적 특성 평가)

  • Ryu, Gum-Sung;Koh, Kyung-Taek;Kang, Su-Tae;Park, Jung-Jun;Kim, Sung-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.353-356
    • /
    • 2008
  • UHPC which was a structural material exhibiting very remarkable mechanical performances with compressive strength, tensile strength and flexural strength rising up to 200MPa, 15MPa and 35MPa, respectively. In addition, this material presents exceptional durability regard to the very low diffusion and penetration speeds of noxious substances like chloride ions This study was carry out to evaluate the effect of flexural behavior according to steel fiber type in UHPC. The results is showing that the steel fiber type have remarkable influence flexural strength Addition to it is showing that steel fiber type made little difference in the first cracking strength but considerable gap in the ultimate flexural strength to use the steel fiber of wave type.

  • PDF

The Evaluation of Flexural Performance in UHPC(Ultra High Performance Concrete) according to Placement Methods (타설방법에 따른 초고성능 콘크리트의 휨성능 평가)

  • Ryu, Gum-Sung;Kang, Su-Tae;Park, Jung-Jun;Ahn, Ki-Hong;Koh, Kyung-Taek;Kim, Sung-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.357-360
    • /
    • 2008
  • UHPC which was a structural material exhibiting very remarkable mechanical performances with compressive strength, tensile strength and flexural strength rising up to 200MPa, 15MPa and 35MPa, respectively. In addition, this material presents exceptional durability regard to the very low diffusion and penetration speeds of noxious substances like chloride ions This study was carry out to evaluate the effect of flexural behavior according to placement method in UHPC. The results is showing that the placement methods have remarkable influence flexural strength Addition to it is showing that the placement methods made little difference in the first cracking strength but considerable gap up to 2 or 3 times in the ultimate flexural strength.

  • PDF

A Study on the Performance Development of Sewage Concrete by Application of Antibiotics (항균제 도포에 의한 하수시설 콘크리트의 성능향상에 관한 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Khil, Bae-Su;Cho, Bong-Suk;Lee, Eui-Bae
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.371-378
    • /
    • 2006
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, physical properties of concrete covered with antibiotics were investigated. As a results of the study, it was proved that the antimicrobial performance of antibiotics was available. Also compressive strength and bond strength of concrete didn't closely connected with antibiotics, and resistance to abrasion, water absorption, air permeability, carbonation, salt damage and chemical attack of concrete was improved remarkably by covering with it.

Evaluation of Diffusion on Cement Mortar and Durability of Concrete Specimen Using Inorganic Coating Material and Surface Treatment System (무기질 도료 및 표면처리 시스템을 적용한 시멘트 모르타르와 콘크리트의 내구성 평가)

  • Kim, In-Seob;Lee, Jong-Kyu;Chu, Yong-Sik;Kim, Tae-Hyun;Shim, Kwang-Bo
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.522-528
    • /
    • 2003
  • Concrete has been considered as a semi-permanent structural material, because its excellent durability. However, such high durable structure is often attacked by some environmental condition such as chloride diffusion, carbonation and so on. In order to prevent the deterioration behaviors of concrete structures. We estimated durability of concrete when used surface treatment system and coatings by new type inorganic coating materials. Base on the results of chloride ion's diffusion test, the coated cement mortar had smaller transmitted quantity.