• Title/Summary/Keyword: 콘크리트 건물

Search Result 533, Processing Time 0.03 seconds

Design of RC dual system building using special seismic detail (내진특수상세를 적용한 RC 이중골조 건물의 설계)

  • Lee, Han-Seon;Ko, Dong-Woo;Sun, Sung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.190-193
    • /
    • 2006
  • The definition of the Dual system is that the total seismic force resistance is to be provided by the combination of the moment frame and the shear walls or braced frames in proportion to their stiffness and the moment frame shall be capable of resisting at least 25% of the design force in Korean Building Code 2005 (KBC 2005). But, the definition of moment frame is ambiguous whether the moment frame include the imaginary columns in the shear wall (Case I) or include only the columns outside the shear wall (Case II). 60-story RC building was designed as dual system for Case I and Case II, and the required strength and reinforcement are compared. Moment and axial capacity of the shear wall of Case II decreased about 5% due to the absence of the column in the shear wall. The requirement of upper and bottom reinforcement of slab in Case II increased 13% and 40%, respectively, when compared to those of Case I. The required longitudinal reinforcement in columns for Case II is about 1.5 times larger than that of Case I.

  • PDF

A Study about Damage of Steel Beam to SRC Column Connection in a New Extension Building (증축된 건축물의 SRC 기둥과 철골보 접합부 손상에 관한 연구)

  • Shim, Hak-Bo;Park, Soon-Jeon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.503-504
    • /
    • 2009
  • It is increased the necessity of the examination for safety of Steel Beam to SRC Column connection part in a new extension building. This study is presented the examination and cause analysis about damage of Steel Beam to SRC Column connection. so it is prevented collapse and extended use duration in building.

  • PDF

Properties of High Strength Concrete before and after Pumping in Response to Strength Level and Pumping Height (초고층 건축물에서 고강도 콘크리트의 강도 및 압송높이 변화에 따른 펌프 압송 전·후의 물성평가)

  • Jung, Sang-Woon;Lee, Hong-Kyu;Jo, Man-Ki;Kim, Gyu-Dong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.274-275
    • /
    • 2014
  • As the increase amount of high rise building, equipments for high rise building have been extensively studied. However quality problems caused as the pumping of concrete including loss of flowalility, air content and increasing of the temperature. In this study, fundamental performances of the 80 MPa concrete before·after pumping has been tested. Results showed slump flow increased after pumping temperature of concrete also increased after pumping. Results also shown air content all satisfied the target range and compressive strength of concrete increased about 20 % after pumping, All the performances satisfied the standard for 80 MPa.

  • PDF

Design Eccentricity of RC Building Structures with Torsional Irregularity (비틀림 비정형성을 가진 RC 건물의 설계편심)

  • 이한선;고동우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.140-143
    • /
    • 2003
  • Recently, many high-rise reinforced concrete (RC) bearing wall structures of multiple occupancy have been constructed, which have the irregularities of weak (or soft) story and torsion at the lower stories simultaneously. The study compared the eccentricity of such a building predicted by design codes, EC 8, IBC 2000 and UBC 97, and by the test results through a series of shaking table tests of 1:12 model. Based on the comparison of the predicted eccentricity and the test result, the conclusions are drawn as follow: Accidental torsion due to the uncertainty on the properties of structure can be reasonably predicted by using the dynamic analysis with the center of mass being shifted by 5 percent of the dimension of the building perpendicular to the direction of the excitations than by using equivalent lateral force procedure

  • PDF

A Study on Thermal Stress in T/G Wall of Containment Building (격납건물 텐던갤러리 벽체의 온도응력에 대한 연구)

  • 김진근;양은익;박영진;송영철;방기성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.193-198
    • /
    • 1998
  • In this study, the change of concrete temperature, strain and thermal stress were measured by using the embedded type concrete gauges in tendon gallery wall of containment building. A finite element analysis was performed to clarify the thermal behavior of concrete. The analytic and test results were investigated to improve the validity of analytic method. According to the test results, concrete temperature, strain and thermal stress were strongly affected by measuring point and environment condition of member. And the thermal stress was developed in the member which was not demoulded at early ages. This is caused by the change of internal temperature and restrained condition. A finite element effectively interpreted the test results by estimating the concrete properties and the site condition.

  • PDF

A Study on the Improved Seismic Analysis of Multistory Shear Wall Buildings (전단벽식 고층건물의 내진해석에 관한 연구)

  • 이준교;이근홍;이수곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.267-272
    • /
    • 1993
  • Currently about 60 contries in the world require earthquake resistant structural design in case of multistory building constructions. In these cases the equivalent lateral force procedure is commonly adopted because of its simplicity and convenience. This procedure, however, is developed based mainly on the first vibration mode response of building structure. The dynamic analysis of tall building shows that the effect of higher modes of vibration on the response of the building can not be neglected. In this paper, the effect of higher modes of vibration on seismic response is evaluated through modal analysis of tall building structures. On the basis of evaluation results, an improved procedure is to be proposed for the extended application of the equivalent lateral force procedure.

  • PDF

Equivalent Beam Model for Flat-Plate Building (무량판 건물의 등가 보 모델)

  • 박수경;김두영;박성무
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.312-316
    • /
    • 1995
  • Flat-plate buildings are commonly modeled as two-dimensional frames to calculate lateral drift, unbalanced moments, and shear at slab-column connections. For gravity loads. the slab-column frames are analyzed using equivalent column approach, while equivalent beam approach is typical for lateral loads. The equivalent beam approach is convenient for computer analysis, but no rational procedure exists for determining the effective width of foor slabs. At present, the determination of the equivalent slab width and its stiffness is a matter of engineering judgement. To account for cracking, overly conservative assumptions are made regarding the stiffness of the slab. A rational approach is therefore needed to realistically estimate the equivalent slab width and its stiffness for unbalanced moment and lateral drift calculations. Based on the test results of 8 interior slab-column connections, an equivalent beam model is proposed in which columns are modeled conventionally as a function of column and slab aspect ratios and the magnitude of the gravity load. the proposed approach is verified with selected experimental results and is founded to be practical and convenient for analyzing flat-plate buildings subjected to gravity and lateral loading.

  • PDF

Seismic Performance of Gravity-Load Designed Post-Tensioned Flat Plate Frames (중력하중으로 설계된 포스트텐션 플랫플레이트 골조의 내진성능)

  • Park, Young-Mi;Rew, Youn-Ho;Han, Sang-Whan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.127-128
    • /
    • 2010
  • The purpose of this study is to evaluate the seismic performance of gravity-designed post tensioned (PT) flat plate frames with and without slab bottom reinforcement passing through the column. For the PT flat plate frames, the slab bottom reinforcement is often omitted since the requirement for the slab bottom reinforcement for PT flat plates is not clearly specified in ACI 318-08. This study evaluates the seismic performance of the model frames was evaluated by conducting nonlinear time history analysis. The seismic performance of PT flat plate frames is significantly improved by placing slab bottom reinforcement passing through the column.

  • PDF

Time Dependent Reliability Analysis of the Degrading RC Containment Structures Subjected to Earthquake Load (지진하중을 받는 RC 격납건물의 열화에 따른 신뢰성 해석)

  • 오병환;최성철;현창헌
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.559-564
    • /
    • 2000
  • Nuclear power plant structures amy be exposed to aggressive environmental effects that may cause their strength and stiffness to decrease over their service lives. Although the physics of these damage mechanisms are reasonably well understood and quantitative evaluation of their effects on time-dependent structural behavior is possible in some instances, such evaluations are generally very difficult and remain novel. The final goal of this study is to develop the reliability analysis of RC containment structures. The cause of the degrading is first clarified and the reliability assessment has been conducted. By introducing stochastic analysis based on random vibration theory, the reliability analysis which can determine the failure probabilities has been established.

  • PDF

Evaluation of Ultimate Pressure Capacity of Prestressed Concrete Containment Building Considering Aging of Materials (재료의 경년상태를 고려한 PSC격납건물의 극한내압능력 평가)

  • 이상근;송영철;권용길;한상훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.805-810
    • /
    • 2000
  • The purpose of this study is to predict long-term structural safety on the Yonggwang Unit 3 prestressed concrete containment building. The aging-related degradations of its main structural materials are investigated and the effects of the property variation of time-dependent materials on the structural behavior of containment building are also assessed through the analysis on the ultimate pressure capacity. The nonlinear finite element analyses for both the design criteria condition a the present aging condition are conducted to assess the present structural capacity of the containment building As a result, it is verified that the structural capacity of the Yonggwang Unit 3 containment building under the present aging condition is judged to be still rugged. n addition, the sensitivity of the ultimate pressrue capacity of containment building according to th degradation levels of the structural materials are assessed. Finally, it is showed that the sensitivity levels are in the order of the tendon, rebar and concrete in case of individual material degradations, and the tendon-rebar, tendon-concrete and rebar-concrete in case of coupled material degradations.

  • PDF