• Title/Summary/Keyword: 콘크리트박리

Search Result 169, Processing Time 0.026 seconds

A Study on Technology of Waterproofing of the Concrete Structure Which Used Soft FRP Resin and Square Groove Cutting Technique (연질 FRP 수지와 정방형 홈 컷팅 기술을 이용한 콘크리트 구조물의 방수기술에 관한 연구)

  • Lee, Hyung-Jun;Choi, Sung-Min;Kim, Sung-Sik;Ahn, Sang-Ku;Cho, Ah-Hyung;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.597-600
    • /
    • 2008
  • In this study the reason which researches the feature of the exposure type waterproofing it uses the technique of the soft FRP it uses the soft unsaturated polyester and the square groove cutting technique with respects and solves the interface separate problem because of the rigid FRP it is used with the repairs and retrofit materials it is caused by in adhesion of concrete insufficiency. The feature of this technique was the dispersion and the reinforcement of the fatigue stress due to the integration behavior and the reinforcement due to the glass-fibre of the concrete due to the soft FRP resin and, it investigated the crack appearance confrontation of concrete and the cohesion stability of the concrete due to the square groove cutting technique with importance. The result of research when it applies the soft FRP with the exposure type waterproofing, is judged with the fact that it will be able to expect a bulge resistance confrontation and creak confrontation ability and cohesion stability improvement.

  • PDF

Spalling Resistance of High Strength Concrete Using Non-Stripping Form (비탈형 거푸집에 의한 고강도 콘크리트의 폭렬방지)

  • You, Ji-Young;Han, Chang-Pyung;Jee, Suk-Won;Han, Min-Cheol;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.865-868
    • /
    • 2008
  • As a part of a series of study, this study reviewed the fire proof characteristics of high performance concrete RC column members using non-stripping form that accompanied metal lath lateral confinement to prevent spalling of high performance concrete which is increasingly used recently, and the results are as follows. Flow and air amount both satisfied target range, and compressive strength, over 80MPa at age 28 days, showed high strength range. As for spalling characteristics, in the case of plain in which no fiber is mixed, severe spalling occurred, and in the case of 0.05% nylon("NY" hereinafter)+polypropylene("PP" hereinafter) fiber mixture, only surface area experienced partial spalling. Regarding non-stripping form changes, both non-stripping 25-20 and non-stripping 50-20 experienced spalling at finish material area, and non-stripping 50-20 showed better spalling proof performance than non-stripping 25-20. In the case of non-stripping 50-40, spalling was prevented, and while mass reduction rate was less than 10%, its temperature hysteresis showed the most excellent fire proof performance with base metal surface area maximum temperature $376.1^{\circ}C$.

  • PDF

Effect of the Various Curing Temperatures on the Finishability of Concrete using Aluminum Form (알루미늄 거푸집을 이용한 콘크리트의 양생온도변화에 따른 표면마감성에 관한 연구)

  • Lee, Dong-Gyu;Kim, Tae-Cheong;Baek, Dae-Hyun;Lee, Seong-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.969-972
    • /
    • 2008
  • This study investigated the effect of the fundamental condition such as release agent, form conditions and types to the surface of concrete with aluminum form on the various temperatures. On the observation with the naked eyes, coated plywood and aluminum form without a scratch showed similar result, and the surface quality of the concrete with aluminum form was gradually decreased corresponding to the increase of the temperature.For the surface roughness, there is no remarkable tendency according to the temperature. However, the difference in accordance with release agent occurred.As void on the surface corresponding to the various temperature, the micro voids ranged $0.1{\sim}1mm$ were increased corresponding to the increasing temperature, so it was confirmed that the chemical reaction wae accelerated. And the voids of the other range also increased. the fundamental condition such as release agent, form conditions and types

  • PDF

Compression Behavior of Steel Plate-Concrete Structures with the Width-to-Thickness Ratio (폭두께비에 따른 강판콘크리트구조의 압축거동)

  • Han, Hong-Soo;Choi, Byong-Jeong;Han, Kweon-Gyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.229-236
    • /
    • 2011
  • This study was conducted to understand the characteristics of the compression behavior of steel plate-concrete(SC) structures with a width-to-thickness ratio under axial loading. SC structures are structural systems where concrete is poured into steel plates to which headed stud bolts had been attached inside. The specimens were classified according to the two width-to-thickness (W/T) ratios of 1.60 and 3.56. Through these experiments, the following conclusions could be arrived at. The fracture pattern of the specimens showed that steel plate buckling occurred between the stud lines, and that a crack occurred at the concrete spalling from the sides of the concrete before the system reached the maximum compressive strength. The maximum compressive strength of the specimens was larger than that of the existing equations (AISC 2005, ACI 318-05, and KBC 2005). With the increased W/T ratio of the specimens, the strength of the concrete core was decreased to account for the confinement effects from the steel plates.

A Study on the Surface Roughness of Corroded Reinforcing Rebar (부식된 철근의 표면 거칠기에 관한 연구)

  • Roh, Young-Sook;Lee, Sun-Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.78-83
    • /
    • 2010
  • This paper discusses the surface roughness of corroded reinforcement rebar in reinforced concrete structures focusing on the quantitative measurement technique for rebar corrosion. Reinforcement rebar was corroded using accelerated corrosion induced method and corrosion rates were 0%, 1%, 2%, 3%, 5%, and 10% of mass losses. Using 3-dimensional scanner each surface profile of reinforcement rebar was established, and surface roughness was measured. Through tests and analyses of corroded reinforcement rebar, the following topics were particularly discussed: measurement of surface roughness, relationship between area and surface roughness, relationship between surface roughness and bond performance. As a result, surface roughness of corroded rebar was found to be very effective to bond strength until 2% of corrosion rate. It was also discussed how to relate surface roughness of corroded rebar to bond strength of reinforced concrete structures.

Cracking and Durability Characteristics of High-early-strength Pavement Concrete for Large Areas using Calcium Nitrate (질산칼슘 혼화재를 사용한 대단면 급속 포장 콘크리트의 균열 및 내구특성)

  • Won, Jong Pil;Lee, Si Won;Lee, Sang Woo;Park, Hae Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.101-108
    • /
    • 2009
  • The performance of high-early strength pavement concrete for large areas is influenced by the physical and chemical environment during service life. Generally, penetration, diffusion, and absorption of harmful materials that exist outside the concrete cause damage to its structure. Thus, we have to use a mixture for durability to keep the required quality for the planned service life. Moreover, in using high-early-strength cement and accelerators, a high heat of hydration to create the initial strength can cause cracks. Based on evaluations from optimal mix proportions of high-early-strength pavement concrete for large areas, we conducted water permeability, abrasion resistance, freeze-thaw, plastic, drying, and autogenous shrinkage tests. Test result showed that a mix of accelerator and PVA fibers showed excellent performance.

Development for Penetrative Performance Improving Agent to In Prevent Deterioration of Concrete Structures (콘크리트 구조물의 내구성능 저하를 방지하는 침투형 성능개선제 개발)

  • Ryu Gum-Sung;Koh Kyoung-Taek;Kim Sung-Wook;Kim Do-Gyeum
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.489-498
    • /
    • 2005
  • Recently, the deterioration of concrete structures have been increased by the damage from salt, carbonization, freezing & thawing and the others. Therefore, the measures for the deterioration of concretes have been taken. Among them, it has been often used that surface treatment which cut off the deterioration factors of durability by protecting the surface of concrete. The water proof and repair materials for concrete mainly use organic materials such as epoxy, these materials excel in intial bonding force and resistance to chemical agents. But they cause difference in the modulus of elasticity and the rate of shrinkage and expansion of concrete, and thus result in such problems as scaling and spatting in the progress of time. Therefore in this study it develop the performance Improving agent of concrete surface that can block a deterioration cause such as $CO_2$ gas, chloride ion and water from the outside and enhance waterproofing ability by reinforcing the concrete surface when applying it to concrete structures.

Mechanical Properties of Polypropylene Fiber mixed in Concrete and Granite Soil Concrete (폴리프로필렌섬유를 혼입한 콘크리트와 화강토콘크리트의 역학적 특성)

  • Jun, Hyung-Soon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.120-126
    • /
    • 2018
  • The study conducted an experiment in which residual aggregate and polypropylene fibers are mixed in concrete, and an experiment in which granite and polypropylene fibers are mixed. Two types of experiments, in particular, changed the amount of polypropylene fibers, and examined the mechanical properties of slump, compressive strength, tensile strength and the like. To establish a light and easy-to-use material for landscape construction and packaging material development by comparing two kinds of experimental results, comparing and analyzing residual aggregate as experimental materials and materials using granite soil to prevent partial destruction due to cracks in drying shrinkage. The more the amount of the PP fibers increases in concrete, the more the volume of the PP fibers increases, the less the slump is determined. As a result of the compressive strength, the cast-down earth concrete is measured to be about 59% to 71% of the concrete strength. As the amount of PP fibers mixed in increased, the compression strength showed a relative decrease. As a result of tensile strength, it is found that the granite concrete is about 68-67% of concrete tensile strength. It was found that the compression strength decreased as the amount of PP fibers mixed in concrete or fire-gant concrete was increased. Then, when polypropylene fibers are mixed in the concrete and the concrete, it is found that tensile strength is increased. By analyzing these results, a fixed amount of PP fiber is mixed in the concrete mixed with the granite soil and utilized for various structures in the field of landscape construction or materials related to packaging, the prevention and improvement effect of the structure is determined.

Flexural Strength Analysis of RC T-Beams Strengthened Using Fiber Sheets (섬유시트로 보강된 T형 철근콘크리트보의 휨 강도 해석)

  • Park, Tae-Hyo;Lee, Gyu-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.234-245
    • /
    • 2003
  • Most of the concrete bridge structures are exposed to damage due to the excessive traffic loading and the aging of the structure. The damage of concrete causes the further deterioration of the function in the concrete structure due to corrosion of the reinforced bars and decohesion between the concrete and the reinforced bar. The quick rehabilitation of the damaged concrete structures has become of great importance in the concrete structural system in order to avoid the further deterioration of the structures. Recently fiber sheets are used for strengthening the damaged concrete structures due to its many advantages such as its durability, non-corrosive nature, low weight, ease of application, cost saving, control of crack propagation, strength to thickness ratio, high tensile strength, serviceability and aesthetic. However, the lack of analytical procedures for assessing the nominal moment capacity by the fiber sheet reinforcement leads to difficulties in the effective process of decisions of the factors in the strengthening procedure. In this work, flexural strengthening effects by fiber sheets bonded on bottom face of the member are studied for the reinforced concrete T beam. In addition, auxiliary flexural strengthening effects by U-type fiber sheets bonded on bottom and side faces of the member to prevent delamination of the bottom fiber sheet are theoretically investigated. The analytical solutions are compared with experimental results of several references to verify the proposed approach. It is shown that the good agreements between the predicted results and experimental data are obtained.

A Study on the Resistance Against Environmental Loading of the Fine-Size Exposed Aggregate Portland Cement Concrete Pavements (소입경 골재노출콘크리트포장의 환경하중 저항성에 대한 연구)

  • Chon, Beom-Jun;Lee, Seung-Woo;Chae, Sung-Wook;Bae, Jae-Min
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.99-109
    • /
    • 2009
  • Fine-size exposed aggregate portland cement concrete pavements (FEACP) have surface texture of exposed aggregate by removing upper 2$\sim$3mm mortar of surface of which curing is delayed by using delay-setting agent. FEACPs have advantages of maintaining low-noise and adequate skid-resistance level during the performance period than general portland cement concrete pavements. It is necessary to ensure the durability environmental loading to prevent unexpected distress during the service life of FEACP. In the process of curing, volume change accompanied change in by moisture and temperature could be an important cause of crack in concrete to construct for successful FEACP, The use of chloride containing deicer may accelerate defects of concrete pavement, such as crack and scaling. This study aim to evaluate environmental loading resistance of FEACP, based on the estimation of shrinkage-crack-control-capability by moisture evaporation and scaling by deicer in freeze-thaw reaction.

  • PDF