• Title/Summary/Keyword: 콘크리트구조설계기준

Search Result 560, Processing Time 0.028 seconds

Experimental Study on the Applicability of Reactivity SiO2 Nano-Materials as Cement Composites (실리케이트계 반응성 나노소재의 시멘트 혼화재로써 적용 가능성에 대한 실험적 연구)

  • Kim, Won-Woo;Moon, Jae-Heum;Baek, Chul-Woo;Yang, Keun-Hyeok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.529-536
    • /
    • 2021
  • In this study, nano-silica and nano-titanium were selected to determine the possibility of applying the binder to reactive nano materials. The basic characteristics of the nano material candidate group were reviewed. and the reactivity of nano materials was reviewed through K-value. The reactivity of the nano silicate materials was measured to be high. Therefore, as a final candidate group, nano silicate materials were selected. The finally selected reactive nano material was reviewed for its usability as a construction binder. The mechanical properties and unit weight of cement paste were reviewed using silica fume and blast furnace slag and nano materials. When cement composites with nano silicate materials, it was confirmed that it was effective in improving the mechanical performance and decrease the unit weight of cement composites.

Fracture Toughness of Concrete Brazilian Disk according to Maximum Size of Coarse Aggregate (굵은골재의 최대치수에 따른 콘크리트 브라질리언 디스크의 파괴인성)

  • Lee, Seung-Hoon;Kim, Hee-Sung;Jang, Hee-Suk;Jin, Chi-Sub
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.185-196
    • /
    • 2006
  • Fracture toughness is a material property for crack initiation and propagation in fracture mechanics. For mode I fracture toughness measurement in concrete, RILEM committees 89-FMT proposed three-point bend tests based on the two-parameter fracture model. But, there is no proposed test method as a standard for mixed mode test for now. And RILEM three-point bend test procedure is complicate. Therefore, in this study, brazilian disks of various size were designed as the concrete with a similar specified concrete strength and maximum size of coarse aggregate($G_{max}$) were respectively 20mm and 40mm. And mode I fracture toughness of brazilian disks was compared with that of RILEM three-point bend test. As a result, it was suggested appropriate size(thickness, diameter) and notch length ratio of brazilan disk on the $G_{max}$. And it was verified that stress intensity factors for mixed mode can be easily calculated with the disk specimen. Stress intensity factors of a concrete brazilian disk were evaluated with finite element analysis and five terms approximation for comparison.

Flexural Performance of Multistage Prestressed and Self-weight Preflex Girder (다단계 자중 프리플렉스 및 프리스트레싱 합성거더의 시공단계에 따른 휨성능 평가)

  • Choi, Byung Ho;Kim, Tae Bong;Park, Sung Kyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.4
    • /
    • pp.311-321
    • /
    • 2017
  • This paper deals with the flexural performance of a composite girder system designed to readily form a composite section without a formwork and to easily realize multistage preflexing and prestressing. After a 3-Dimensional finite element modeling for construction stage analysis, the parametric numerical analysis was performed to analyse the stress distribution on the composite girder sections and the prestressing effects along with concrete pouring method and strand tensioning method. Based on the stress distribution analysis, a favorable construction stage model has been rationally chosen and then the ultimate flexural strengths were evaluated to conduct a comparative study, which exceed the nominal flexural strength suggested by the current design specification(ASD). It can be concluded that the proposed composite girder and fabrication procedure should have a sufficient structural performance.

Characteristics of Dynamic Shear Behavior of Pile-Soil Interface Considering pH Conditions of Groundwater (지하수 pH조건을 고려한 말뚝-지반 접촉면의 동적 전단거동 특성)

  • Kwak, Chang-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.5
    • /
    • pp.5-17
    • /
    • 2022
  • A pile is a type of medium for constructing superstructures in weak geotechnical conditions. A pretensioned spun high-strength concrete (PHC) pile is composed of high-strength concrete with a specified strength greater than 80 MPa. Therefore, it has advantages in resistance to axial and bending moments and quality control and management since it is manufactured in a factory. However, the skin friction of a pile, which accounts for a large portion of the pile bearing capacity, is only approximated using empirical equations or standard penetration test (SPT) N-values. Particularly, there are some poor research results on the pile-soil interface under the seismic loads in Korea. Additionally, some studies do not consider geoenvironmental elements, such as groundwater pH values. This study performs sets of cyclic simple shear tests using submerged concrete specimens for 1 month to consider pH values of groundwater and clay specimens composed of kaolinite to generate a pile-soil interface. 0.2 and 0.4 MPa of normal stress conditions are considered in the case of pH values. The disturbed state concept is employed to express the dynamic behavior of the interface, and the disturbed function parameters are newly suggested. Consequently, the largest disturbance increase under basic conditions is observed, and an early approach to the failure under low normal stress conditions is presented. The disturbance function parameters are also suggested to express this disposition quantitatively.

Evaluation of Proper Level of the Longitudinal Prestress for the Precast Deck of Railway Bridges Considering the Temperature Change (철도교용 프리케스트 바닥판의 온도변화를 고려한 적정한 종방향 프리스트레스 수준의 산정)

  • Jeon, Se Jin;Kim, Young Jin;Kim, Seong Woon;Kim, Cheol Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3D
    • /
    • pp.499-509
    • /
    • 2006
  • Precast concrete deck has many advantages comparing with the in-situ concrete deck, and has been successfully applied to replacement of the deteriorated decks and to the newly constructed highway bridges in domestic region. In order to apply the precast decks into the railway bridges, however, differences of the load characteristics between the highway and the railway should be properly taken into account including the train load, longitudinal force of the continuous welded rail, acceleration or braking force, temperature change and shrinkage. Proper level of the longitudinal prestress of the tendons that can ensure integrity of the transverse joints in the deck system is of a primary importance. To this aim, the longitudinal tensile stresses induced by the design loads are derived using three-dimensional finite element analyses for the frequently adopted PSC composite girder railway bridge. The effect of the temperature change is also investigated considering the design codes and theoretical equations in an in-depth manner. The estimated proper prestress level to counteract those tensile stresses is above 2.4 MPa, which is similar to the case of the highway bridges.

Seismic Safety Evaluation of Korean R/C School Buildings Built in the 1980s (1980년대 국내 철근콘크리트 학교건물의 내진 안전성 평가에 관한 연구)

  • Lee, Kang-Seok;Wi, Jeong-Du;Kim, Yong-In;Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.149-159
    • /
    • 2009
  • The main purpose of this study is to evaluate the seismic safety of Korean R/C school buildings built in the 1980s, based on "the Japanese Standard for Evaluation of Seismic Capacity of Existing R/C Buildings", the nonlinear static and the nonlinear dynamic analyses. The evaluation result of the Japanese Standard showed that R/C school buildings built in the 1980s have 0.2 through 0.4 of seismic indices($I_S$). This result indicates that more than medium damage could be potentially occurred under a medium intensity level of ground motion(150g). The results of the nonlinear analyses and the post-earthquake damage evaluation method showed that Korean R/C school buildings can be suffered moderate and severe damages under a 150gal and a 200gal intensity levels of ground motions, respectively. These results reveal that R/C school buildings should be urgently required a actual earthquake preparedness measures including seismic strengthening for future earthquake.

Investigation of Behaviours of Wall and Adjacent Ground Considering Shape of Geosynthetic Retaining Wall (보강토 옹벽의 형상을 고려한 벽체 및 인접지반 거동 연구)

  • Lee, Jong-Hyun;Oh, Dong-Wook;Kong, Suk-Min;Jung, Hyuk-Sang;Lee, Yong-Joo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.1
    • /
    • pp.95-109
    • /
    • 2018
  • Recently, GRS (Geosynthetic Retaining Segmental) wall has been widely used as a method to replace concrete retaining wall because of its excellent structural stability and economic efficiency. It has been variously applied for foundation, slope, road as well as retaining wall. The GRS wall system, however, has a weak point that is serious crack of wall due to stress concentration at curved part of it. In this study, therefore, behaviour of GRS wall according to shape of it, shich has convex and concave, are analysed and compared using Finite Element analysis as the fundamental study for design optimization. Results including lateral deflection, settlements of ground surface and wall obtained from 2D FE analysis are compared between straight and curved parts from 3D FE analysis.

Seismic performance evaluation of circular composite columns by shaking table test (진동대 실험을 통한 원형 합성 기둥의 내진 성능 평가)

  • Shim, Chang-Su;Chung, Young-Soo;Park, Ji-Ho;Park, Chang-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.71-81
    • /
    • 2007
  • For the design of composite bridge piers, detail requirements for the reinforcements is not clear to satisfy the required seismic performance. Composite bridge piers were suggested to reduce the sectional dimensions and to enhance the ductility of the columns under earthquake loadings. In this paper, five specimens of concrete encased composite columns of 400mm diameter with single core steel were fabricated to investigate the seismic performance of the composite columns. Shaking table tests and a Pseudo-Dynamic test were carried out and structural behavior of small-scaled models considering near-fault motions was evaluated. Test parameters were the pace of the transverse reinforcement, lap splice of longitudinal reinforcement and encased steel member sections. The displacement ductility from shaking table tests was lower than that from the pseudo-dynamic test. Limited ductile design and 50% lap splice of longitudinal reinforcement reduced the displacement ductility. Steel ratio showed significant effect on the ultimate strength. Lap splice and low transverse reinforcements reduced the displacement capacity. The energy dissipation capacity of composite columns did not show significant difference according to details.

Experimental Study on Effect of Confinement Details for Lap Splice of Headed Deformed Reinforcing Bars in Grade SD400 and SD500 (구속상세가 SD400 및 SD500 확대머리 이형철근의 겹침이음에 미치는 영향에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.62-71
    • /
    • 2015
  • KCI 2012 and ACI318-11 contains development length provisions for the use of headed deformed bars in tension and does not allow their tension lap splices. In ACI318-11, the confinement factor, such as transverse reinforcement factor, is not used to calculate the development length of headed bars. The purpose of this experimental study is to evaluate the effect of confinement details to the lap splice performance of headed deformed reinforcing bars in grade SD400 and SD500. The confinement details are stirrups and tie-down bars in lap zone. Test results showed that specimens with only stirrups had the brittle failure and could not increase lap strengths, and that specimens with composite confinements by stirrups and tie-down bars had the flexural strengths over than nominal flexural strengths. Stirrups with tie-down bars can have an effect on improvement in lap splice of headed bars in grade SD400 and SD500.

A Study of Connection Stability for Reinforced Retaining Wall Constructed with Soilbag with Varying Connection Strength (연결강도 변화에 의한 Soilbag 보강토 옹벽 연결부의 안정성 평가)

  • Lee, Sang-Moon;Choi, Changho;Shin, Eun-Chul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.1
    • /
    • pp.101-107
    • /
    • 2013
  • Environmental-friendly and economical construction are the recent issues for civil structures and soilbag as facing wall is widely used for cut-slope remediation projects. However, the stability of structures is an important issue for the use of environmental-friendly and economical materials. In order to understand the stability of soilbag reinforced retaining wall, tensile resistance, rupture, tensile strength, and internal/external safety factor of the wall were analyzed with MSEW program and the results were compared to the safety factor of block-type reinforced walls. The stability of retaining wall was analyzed with reduction coefficients of connection strength to check the connection stability. Because it is possible to move between soilbag and geogrid connector for soilbag retaining wall, the safety factor of the wall was analyzed with different inclination angles of soilbag. The analysis result shows that the connection strength and internal/external stability of soilbag reinforced wall satisfy the stability criteria.