• Title/Summary/Keyword: 컴퓨터 단층 영상

Search Result 378, Processing Time 0.025 seconds

Vessel Tracking Algorithm using Multiple Local Smooth Paths (지역적 다수의 경로를 이용한 혈관 추적 알고리즘)

  • Jeon, Byunghwan;Jang, Yeonggul;Han, Dongjin;Shim, Hackjoon;Park, Hyungbok;Chang, Hyuk-Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.137-145
    • /
    • 2016
  • A novel tracking method is proposed to find coronary artery using high-order curve model in coronary CTA(Computed Tomography Angiography). The proposed method quickly generates numerous artificial trajectories represented by high-order curves, and each trajectory has its own cost. The only high-ranked trajectories, located in the target structure, are selected depending on their costs, and then an optimal curve as the centerline will be found. After tracking, each optimal curve segment is connected, where optimal curve segments share the same point, to a single curve and it is a piecewise smooth curve. We demonstrated the high-order curve is a proper model for classification of coronary artery. The experimental results on public data set sho that the proposed method is comparable at both accuracy and running time to the state-of-the-art methods.

Reproducibilities of cephalometric measurements of three-dimensional CT images reconstructed in the personal computer (개인용 컴퓨터에서 재구성한 3차원 전산화단층영상의 두부계측 재현성)

  • Jeon Kug-Jin;Park Hyok;Lee Hee-Cheol;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.33 no.3
    • /
    • pp.171-178
    • /
    • 2003
  • Purpose: The purpose of this study was to report the reproducibility of intra-observer and inter-observer consistency of cephalometric measurements using three-dimensional (3D) computed tomography (CT), and the degree of difference of the cephalometric measurements. Materials and Methods: CT images of 16 adult patients with normal class I occlusion were sent to personal computer and reconstructed into 3D images using V-Works 3.5/sup TM/(Cybermed Inc., Seoul, Korea). With the internal program of V-Works 3.5/sup TM/, 12 landmarks on regular cephalograms were transformed into 21 analytic categories and measured by 2 observers and in addition, one of the observers repeated their measurements. Intra-observer difference was calculated using paired t-test, and inter-observer by two sample test. Results: There were significant differences in the intra-observer measurements (p < 0.05) in four of the categories which included ANS-Me, ANS-PNS, Cdl-Go (Lt), GoL-GoR, but with the exception of Cdl-Go (Lt), ZmL-ZmR, Zyo-Zyo, the average differences were within 2 mm of each other. The inter-observer observations also showed significant differences in the measurements of the ZmL-ZmR and Zyo-Zyo categories (p < 0.05). With the exception of the Cdl-Me (Rt), ZmL-ZmR, Zyo-Zyo categories, the average differences between the two observers were within 2 mm, but the ZmL-ZmR and Zyo-Zyo values differed greatly with values of 8.10 and 19.8 mm respectively. Conclusion: In general, 3D CT images showed greater accuracy and reproducibility, with the exception of suture areas such as Zm and Zyo, than regular cephalograms in orthodontic measurements, showing differences of less than 2 mm, therefore 3D CT images can be useful in cephalometric measurements and treatment planning.

  • PDF

Diagnostic Imaging of Liver Cirrhosis in a Shih-Tzu Dog (시츄견에서 발생한 간경화의 영상 진단)

  • Choi, Ho-Jung;Lee, Ki-Ja;Chang, Jin-Hwa;An, Ji-Young;O, I-Se;Ahn, Se-Joon;Jeong, Seong-Mok;Park, Seong-Jun;Cho, Sung-Whan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.367-370
    • /
    • 2009
  • A 5-year-old, intact female Shih-Tzu dog was presented with 1 year history of icterus, ascites and anorexia. The serum biochemistry revealed elevated liver enzyme levels. Microhepatica and decreased serosal detail were detected in abdominal radiography. Abdominal ultrasonographic findings included irregular liver margins, multifocal hypoechoic nodules in the liver parenchyma, and ascites. Computed tomography (CT) showed multifocal hypodense nodules with ring-like contrast enhancement. Cytologic and histopathologic examination by liver core biopsy revealed fibrosis. Cirrhosis was diagnosed based on above results. This report focuses on the imaging characteristics of ultrasonography and CT for liver cirrhosis in a dog.

An Efficient Correction Process of CT-Simulator Couch with Current Diagnostic CT Scanners (진단용 CT-모의치료기 테이블의 효율적인 교정 방법)

  • Goo, Eun-Hoe;Lee, Jae-Seung;Cho, Jung-Keun;Moon, Seong-Kwon
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.254-261
    • /
    • 2009
  • This study suggested that the table of CT-simulator and the laser alignment system using diagnostic CT scanner have an efficient method for improvement in alignment between the planned target center of traverse image with CT scanner. It was conducted on the daily QA when presented in the AAPM TG66 with correcting the laser alignment system using geometric trigonometric functions and investigated the effectiveness of correction methods as compared with those before and after correction. Before correction error was 3.82mm between the planned target center of image, the table longitudinal axis was twisted with 0.436o. The laser alignment system using geometric trigonometric functions in after correction was satisfied with tolerance limits of ${\pm}2mm$ when occurred about 0.7mm in errors between the planned target center. The table correction to satisfy the geometric accuracy is very inefficient over against the time and economic loss as well as technical limits in the case of application as only radiation therapy associated with CT-simulator with diagnostic CT scanner in use. But, the method which corrects the laser alignment system is economic and relatively simple with possibility of getting well geometric accuracy and we suppose that it is efficient method for applying in the clinic.

Diagnostic Imaging of Lipoma in the Retroperitoneum and Pelvic Cavity in a Dog (개의 후복강과 골반강에 발생한 지방종의 진단영상 증례)

  • Lee, Nam-Soon;Kim, Jun-Young;Na, Eung-Sic;Kim, Mi-Eun;Lee, Hye-Yeon;Choi, Mi-Hyun;Kim, Wan-Hee;Kim, Dae-Yong;Choi, Min-Cheol;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.88-92
    • /
    • 2010
  • An 11-year-old, spayed female, weighing 10 kg miniature Schnauzer was admitted for abdominal distension, anorexia, pollakiuria, and constipation. A large, homogeneous fat opacity mass was identified in the retroperitoneum and pelvic cavity on the abdominal survey radiography. The mass displaced the descending colon peripherally and ventrally, and the urinary bladder ventrally. On the abdominal ultrasonographic examination, the mass was uniformly hyperechoic with a coarse internal echo texture and had outer hyperechoic capsule, and it showed homogeneously same attenuation (-180 ~ -110 HU) as adjacent fat on the computed tomography. There was no evidence of invasion into the surrounding structures or organs. Cytological findings from fine needle aspirates were numerous sheets and clusters of adipocytes. The dog showed complete resolution of clinical signs after surgical resection of the mass. The mass was confirmed as simple lipoma through histopathological examination.

Visibility-based Automatic Path Generation Method for Virtual Colonoscopy (가상 대장내시경을 위한 가시성을 이용한 자동 경로 생성법)

  • Lee Jeongjin;Kang Moon Koo;Cho Myoung Su;Shin Yeong Gil
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.10
    • /
    • pp.530-540
    • /
    • 2005
  • Virtual colonoscopy is an easy and fast method to reconstruct the shape of colon and diagnose tumors inside the colon based on computed tomography images. This is a non-invasive method, which resolves weak points of previous invasive methods. The path for virtual colonoscopy should be generated rapidly and accurately for clinical examination. However, previous methods are computationally expensive because the data structure such as distance map should be constructed in the preprocessing and positions of all the points of the path needs to be calculated. In this paper, we propose the automatic path generation method based on visibility to decrease path generation time. The proposed method does not require preprocessing and generates small number of control points representing the Path instead of all points to generate the path rapidly. Also, our method generates the path based on visibility so that a virtual camera moves smoothly and a comfortable and accurate path is calculated for virtual navigation. Also, our method can be used for general virtual navigation of various kinds of pipes.

Development and Evaluation of Quality Assurance Worksheet for the Radiation Treatment Planning System (방사선치료계획 시스템의 정도관리 절차서 개발 및 유용성 평가)

  • Cho Kwang Hwan;Choi Jinho;Shin Dong Oh;Kwon Soo Il;Choi Doo Ho;Kim Yong Ho;Lee Sang Hoon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.186-191
    • /
    • 2004
  • The periodic Quality Assurance (QA) of each radiation treatment related equipments is important one, but quality assurance of the radiation treatment planning system (RTPS) is still not sufficient rather than other related equipments in clinics. Therefore, this study will present and test the periodic QA program to compare, evaluation the efficiency of the treatment planning systems. This QA program is divided to terms for the input, output devices and dosimetric data and categorized to the weekly, monthly, yearly and non-periodically with respect to the job time, frequency of error, priority of importance. CT images of the water equivalent solid phantom with a heterogeneity condition are input into the RTPS to proceed the test. The actual measurement data are obtained by using the ion chamber for the 6 MV, 10 MV photon beam, then compared a calculation data with a measurement data to evaluate the accuracy of the RTPS. Most of results for the accuracy of geometry and beam data are agreed within the error criteria which is recommended from the various advanced country and related societies. This result can be applied to the periodic QA program to improve the treatment outcome as a proper model in Korea and used to evaluate the accuracy of the RTPS.

  • PDF

GORHAM-STOUT DISEASE OF THE MANDIBLE: A CASE REPORT (하악골에 발생한 Gorham-Stout 증후군: 증례 보고)

  • Ji, Young-Min;Song, Gin-Ah;Shin, Jung-Hyun;Pang, Kang-Mi;Kim, Soung-Min;Myoung, Hoon;Seo, Byoung-Moo;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon;Kim, Myung-Jin;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.572-576
    • /
    • 2008
  • Gorham-Stout disease is a rare skeletal disease which is progressive and spontaneous and idiopathic resorption of whole body bone. In the initial stage, the osteolytic site is replaced by histologically benign vascular proliferation without new bone formation and finally by dense fibrous tissues. We encountered with a patient involving the mandible with attention by the clinical, radiographic, scintigraphic, angiographic, and computed tomography. We resected the mandibular lesion which was reconstructed with a fibular free flap. We report literature review with a mandibular lesion involved with Gorham-Stout disease.

Radiomics-based Machine Learning Approach for Quantitative Classification of Spinal Metastases in Computed Tomography (컴퓨터 단층 촬영 영상에서의 전이성 척추 종양의 정량적 분류를 위한 라디오믹스 기반의 머신러닝 기법)

  • Lee, Eun Woo;Lim, Sang Heon;Jeon, Ji Soo;Kang, Hye Won;Kim, Young Jae;Jeon, Ji Young;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.71-79
    • /
    • 2021
  • Currently, the naked eyes-based diagnosis of bone metastases on CT images relies on qualitative assessment. For this reason, there is a great need for a state-of-the-art approach that can assess and follow-up the bone metastases with quantitative biomarker. Radiomics can be used as a biomarker for objective lesion assessment by extracting quantitative numerical values from digital medical images. In this study, therefore, we evaluated the clinical applicability of non-invasive and objective bone metastases computer-aided diagnosis using radiomics-based biomarkers in CT. We employed a total of 21 approaches consist of three-classifiers and seven-feature selection methods to predict bone metastases and select biomarkers. We extracted three-dimensional features from the CT that three groups consisted of osteoblastic, osteolytic, and normal-healthy vertebral bodies. For evaluation, we compared the prediction results of the classifiers with the medical staff's diagnosis results. As a result of the three-class-classification performance evaluation, we demonstrated that the combination of the random forest classifier and the sequential backward selection feature selection approach reached AUC of 0.74 on average. Moreover, we confirmed that 90-percentile, kurtosis, and energy were the features that contributed high in the classification of bone metastases in this approach. We expect that selected quantitative features will be helpful as biomarkers in improving the patient's survival and quality of life.

Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report (무치악 환자에서 CAD/CAM을 이용한 임플란트 식립($NobelGuide^{TM}$) 및 즉시하중 증례)

  • Ko, Kyoung-Ho;Lim, Kwang-Gil;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.233-245
    • /
    • 2011
  • With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.