Browse > Article

Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report  

Ko, Kyoung-Ho (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University)
Lim, Kwang-Gil (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University)
Kim, Dae-Gon (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University)
Park, Chan-Jin (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University)
Cho, Lee-Ra (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University)
Publication Information
Journal of Dental Rehabilitation and Applied Science / v.27, no.2, 2011 , pp. 233-245 More about this Journal
Abstract
With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.
Keywords
CAD/CAM; flapless surgery; immediate loading; accuracy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Adell R, Lekholm U, Rockler B and Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10:387-416.   DOI
2 Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000;11:12-25.   DOI   ScienceOn
3 Gapski R, Wang HL, Mascarenhas P and Lang NP. Critical review of immediate implant loading. Clin Oral Implants Res 2003;14:515-427.   DOI   ScienceOn
4 Ostman PO. Immediate/early loading of dental implants. Clinical documentation and presentation of a treatment concept. Periodontol 2000 2008:47; 90-112.   DOI   ScienceOn
5 Degidi M, Piattelli A, Felice P, and Carinci F. Immediate functional loading of edentulous maxilla; a 5-year restrospective study of 388 titanium implants. J Periodontol 2005;76:1016-24.   DOI   ScienceOn
6 Horiuchi K, Uchida H, Yamamoto K, Sugimura M. Immediate loading of Branemark system implants following placement in edentulous patients: a clinical report. Int J Oral Maxillofac Implants 2000;15: 824-30.
7 Bergkvist G, Sahlholm S, Karlsson U, Nilner K, Lindh C. Immediately loaded implants supporting fixed prostheses in the edentulous maxilla: a preliminary clinical and radiologic report. Int J Oral Maxillofac Implants 2005;20:399-405.
8 Aalam AA, Nowzari H, Krivitsky A. Functional restoration of implants on the day of surgical placement in the fully edentulous mandible: a case series. Clin Implant Dent Relat Res 2005;7:10-6.   DOI   ScienceOn
9 Wolfinger GJ, Balshi TJ, Rangert B. Immediate functional loading of Brånemark system implants in edentulous mandibles: clinical report of the results of developmental and simplified protocols. Int J Oral Maxillofac Implants 2003;18:250-7.
10 Ioannidou E, Doufexi A. Does loading time affect implant survival? A meta-analysis of 1,266 implants. J Periodontol 2005;76:1252-8.   DOI   ScienceOn
11 Fuster-Torres MA, Albalat-Estela S, Alcañiz-Raya M, Penarrocha-Diago M. CAD / CAM dental systems in implant dentistry: update. Med Oral Patol Oral Cir Bucal 2009;14:141-5.
12 Strub JR, Rekow ED, Witkowski S. Computer-aided design and fabrication of dental restorations: current systems and future possibilities. J Am Dent Assoc 2006;137:1289-96.   DOI
13 Verstreken K, Van Cleynenbreugel J, Marchal G, Naert I, Suetens P, van Steenberghe D. Computer- assisted planning of oral implant surgery: a three- dimensional approach. Int J Oral Maxillofac Implants 1996;11:806-10.
14 van Steenberghe D, Glauser R, Blombäck U, Andersson M, Schutyser F, Pettersson A, Wendelhag I. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clin Implant Dent Relat Res 2005;7 Suppl 1:S111-20   DOI
15 Tee-Khin N, Cheng AC, Lee H, Wee AG, Leong EW. The management of a completely edentulous patient using simultaneous maxillary and mandibular CAD/CAM-guided immediately loaded definitive implant-supported prostheses: a clinical report. J Prosthet Dent 2008;99:416-20.   DOI   ScienceOn
16 Balshi SF, Wolfinger GJ, Balshi TJ. Surgical planning and prosthesis construction using computed tomography, CAD/CAM technology, and the Internet for immediate loading of dental implants. J Esthet Restor Dent 2006;18:312-23.   DOI   ScienceOn
17 Kupeyan HK, Shaffner M, Armstrong J. Definitive CAD/CAM-guided prosthesis for immediate loading of bone-grafted maxilla: a case report. Clin Implant Dent Relat Res 2006;8:161-7.   DOI   ScienceOn
18 Marchack CB. An immediately loaded CAD/CAM- guided definitive prosthesis: a clinical report. J Prosthet Dent 2005;93:8-12.   DOI   ScienceOn
19 Dreiseidler T, Neugebauer J, Ritter L, Lingohr T, Rothamel D, Mischkowski RA, Zöller JE. Accuracy of a newly developed integrated system for dental implant planning. Clin Oral Implants Res 2009;20:1191-9.   DOI   ScienceOn
20 Eggers G, Patellis E, Mühling J. Accuracy of template-based dental implant placement. Int J Oral Maxillofac Implants. 2009;24:447-54.
21 Park HS, Hwang JW. Implant overdenture & fixed complete prosthesis. 1st ed. Seoul: Well Pub. Co.; 2005.
22 Sadowsky. The implant-supported prosthesis for the edentulous arch: Design considerations. J Prosthet Dent 1997;78:28-33   DOI   ScienceOn
23 van Steenberghe D, Naert I, Andersson M, Brajnovic I, Van Cleynenbreugel J, Suetens P. A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. Int J Oral Maxillofac Implants 2002;17:663-70.
24 Valente F, Schiroli G, Sbrenna A. Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. Int J Oral Maxillofac Implants. 2009:24:234-42.
25 Yong LT, Moy PK. Complications of computer-aided- design / computer-aided-machining-guided (Nobel Guide) surgical implant placement: an evaluation of early clinical results. Clin Implant Dent Relat Res 2008;10:123-7.   DOI   ScienceOn
26 Komiyama A, Klinge B, Hultin M. Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery. Clin Oral Implants Res 2008;19:677-85.   DOI   ScienceOn
27 Gupta S, Lechner SK, Duckmanton NA. Maxillary changes under complete dentures opposing mandibular implant-supported fixed prostheses. Int J Prosthodont 1999;12:492-7.