• Title/Summary/Keyword: 충전액

Search Result 114, Processing Time 0.023 seconds

Removal of Lead from Lead-loaded Activated Carbon Using Water Electrolysis (물의 전기분해를 이용한 납-흡착 활성탄으로부터 납의 제거)

  • Kim, Bu Ung;Sung, Kyoung Sik;Choi, Yeon Seok
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.929-933
    • /
    • 1999
  • Under the condition of water electrolysis in aqueous hydrochloric acid as the electrolyte, the lead removal from the lead-loaded activated carbon packed on the anode was investigated. The adequate flow condition is a total flow rate of 10 mL/min in the same flow rate ratio to both electrodes. The increase of current decreases pH values at the anode and the decrease of pH leads to the lead removal. This work shows that the water electrolysis is an efficient method for the lead removal from the lead-loaded activated carbon with a reduction in quantity of the chemical used in comparison with the acid rinse.

  • PDF

Foam Separation of Yeast Cells (효모의 포말분리)

  • 서근학;남기두
    • KSBB Journal
    • /
    • v.8 no.3
    • /
    • pp.282-286
    • /
    • 1993
  • A bath foam separator has been used to separate yeast cells from their culture broth without the use of any surface-active agents. The cell separation ratio was improved in proportion to a separator level and nitrogen flow rates. Percentage of yeast removal after 3 minutes of operation was more than 90. The cell separation ratio was also improved by the addition of 0.2g/l $CaCl_2$.

  • PDF

Effects of Lithium Bis(Oxalate) Borate as an Electrolyte Additive on High-Temperature Performance of Li(Ni1/3Co1/3Mn1/3)O2/Graphite Cells (LiBOB 전해액 첨가제 도입에 따른 Li(Ni1/3Co1/3Mn1/3)O2/graphite 전지의 고온특성)

  • Jeong, Jiseon;Lee, Hyewon;Lee, Hoogil;Ryou, Myung-Hyun;Lee, Yong Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.2
    • /
    • pp.58-67
    • /
    • 2015
  • The effects of electrolyte additives, lithium bis(oxalate)borate (LiBOB), fluoroethylene carbonate (FEC), vinylene carbonate (VC), 2-(triphenylphosphoranylidene) succinic anhydride (TPSA), on high-temperature storage properties of $Li(Ni_{1/3}Co_{1/3}Mn_{1/3})O_2$/graphite are investigated with coin-type full cells. The 1 wt.% LiBOB-containing electrolyte showed the highest capacity retention after high temperature ($60^{\circ}C$) storage for 20 days, 86.7%, which is about 5% higher than the reference electrolyte, 1.15M lithium hexafluorophosphate ($LiPF_6$) in ethylene carbonate/ethyl methyl carbonate (EC/EMC, 3/7 by volume). This enhancement is closely related to the formation of semi-carbonate compounds originated from $BOB^-$ anions, thereby resulting in lower SEI thickness and interfacial resistance after storage. In addition, the 1 wt.% LiBOB-containing electrolyte also exhibited better cycle performance at 25 and $60^{\circ}C$ than the reference electrolyte, which indicates that LiBOB is an effective additive for high-temperature performance of $Li(Ni_{1/3}Co_{1/3}Mn_{1/3})O_2$/graphite chemistry.

The Effects of Packed Red Blood Cell Washing and Circuit Precirculation-Ultrafiltration on the Production of Cytokines by Open Heart Surgery (충전용 농축적혈구의 세척 및 체외순환로의 전순환-초여과법이 개심수술에 의한 사이토카인 형성에 미치는 영향)

  • 전태국;노준량
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.199-208
    • /
    • 2002
  • Background: The washing of packed red blood cells could remove pro-inflammatory mediators, cell debris, and micro-particles contained in packed red blood cells, and the preci-rculation-ultrafiltration (recirculation and ultrafiltration of circuit itself before cardiopulmonary bypass) could attenuate the initial inflammatory reaction and remove the initial proinflam-matory mediators. This study was performed to evaluate whether the washing of packed red blood cells and precirculation-ultrafiltration can reduce the production of cytokines that have an important role in myocardial reperfusion injury. This study investigated the effects of washing the packed red blood cells and precirculation-ultrafiltration on the production of cytokines during and after cardiopulmonary bypass and open heart surgery. Material and Method: Forty eight infants with VSD undergoing open heart surgery under cardiopulmonary bypass were randomized into control group (group C, n=12), washing group (group W, n= 12), precirculation-ultrafiltration group (group F, n: 12), and combined group(washing and precirculation-ultrafiltration, group WF, n=12). Blood samples were obtained before, during, and after the bypass to assess plasma level of tumor necrosis factor-$\alpha$(TNF-$\alpha$), interleukin-6(IL-6), and interleukin-8 (IL-8). Results: Expressions of TNF-$\alpha$ were significantly reduced in combined group (group WF) compared with group C, group W, and group F (p<0.05). Expression of IL-6 were significantly reduced in group W, group F, and group WF compared with group C (p<0.05), but similar among group W, group F, and group WF (p=0.053). Expression of IL-8 were reduced in group W and group WF compared with group C (p<0.05), but similar among group W, group F, and group WF (p=0.067). Conclusion: In conclusion, the washing of packed red blood cells and precirculation-ultrafiltration blunted the increase of TNF-$\alpha$ , IL-6, and IL-8 during and after open heart surgery with cardiopulmonary bypass. However, the clinical benefits of these treatments remains unproven.

The effect of MTAD on the apical leakage of obturated root canals: an electrochemical study (MTAD의 치근단 누출에 미치는 영향에 대한 전기화학적 연구)

  • Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.119-124
    • /
    • 2006
  • The purpose of this study was to evaluate the effect of newly developed endodontic root canal cleanser (MTAD) on the apical leakage of obturated root canal using an electrochemical method. Canals of 60 extracted single-rooted human teeth were prepared by using a crown-down technique with rotary nickel-titanium files. In Group 1 (positive control group) and 2 (negative centre) group), 5.25% NaOCl was used as a canal irrigant and no canal wall treatment was done. In group 3 only 5.25% NaOCl were used as canal irrigant, canal wall treatment and final rinse. In group 4, specimens were irrigated with 5.25% NaOCl, treated with 5 ml of 17% EDTA for 5 minutes and final rinsed with 5.25% NaOCl Specimens of group 5 were irrigated with 1 3% NaOCl and treated with 5 ml of MTAD for 5 minutes. All root canals are dried with paper points and obtuated with gutta-percha and AH plus as a sealer using a continuous wave of condensation technique except in the group 1. The electrical resistance between the standard and experimental electrodes in canals was measured over a period of 10 days. Rising of apical leakage with time was observed for all the groups. Group 4 and 5 showed lower apical leakage than group 3 but differences between the group 3, 4 and 5 were no statistical significance at any measurement time.

Studies on Goucoalkaloids in Plants I. High Performance Liquid Chromatographic Analysis of Glucoalkaloids in Periderm and Cortex of Potato (Solanum tuberosum var. May Queen) (식물체(植物體)의 Glucoalkaloids 에 관(關)한 연구(硏究) 제1보(第1報) 고속액체(高速液體)크로마토그래피에 의한 감자(Solanum tuberosum var. May Queen)의 피층부(皮層部) 및 수질부(髓質部)의 Glucoalkaloids 측정(測定))

  • Hwang, Chun-Sun;Lee, Sung-Woo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.11 no.3
    • /
    • pp.1-4
    • /
    • 1982
  • By high performance liquid chromatography, separation and quantification of glucoalkaloids $({\alpha}-chaconine$and${\alpha}-solanine)$ from potato (Solanum tuberosum, var. May Queen) was established using periderm and cortex. $Nucleosil-NH_2\;(10{\mu}m)$ was packed in two stainless steel columns ($4.0\;ID{\times}15\;cm$ and $4.0\;ID{\times}25\;cm$) which were connected in sequence and eluted with the mixture of tetrahydrofuran, phosphoric acid buffer and acetonitrile (50 : 25 : 25, v/v/v) at the flow rate of 1ml/min. and the absorbance were read at 208 nm. Retention time was 6.92 min. for ${\alpha}-chaconine$ and 10.96 min. for ${\alpha}-solanine$ with complete separation. This method took 12 min. per sample and seemed best. ${\alpha}-Chaconine$ and ${\alpha}-solanine$ were found much in periderm than in cortex.

  • PDF

Effect of the particle size on the electrical contact in selective electro-deposition of copper (구리의 선택적 전착에서 결정 입자의 크기가 전기적 접촉성에 미치는 영향)

  • Hwang, Kyu-Ho;Lee, Kyung-Il;Joo, Seung-Ki;Kang, Tak
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.1 no.2
    • /
    • pp.79-93
    • /
    • 1991
  • With the advent of ULSI, many problems in previous metallization techniques and interconnection materials have become more serious. In this work, selective deposition of copper to fill the submicron contact has been tried. After forming electro-deposited copper films on p-type (100) silicon wafer using 0.75M $CuSO_4{\cdot}$5H_2O$ as an electrolyte, the effect of deposition time, current density and concentration of an additive on film properties were investigated. Film thickness, particle size and resistivity were analyzed by Alpha Step, SEM and 4 - point probe measurement respectively. The deposition rate was about $0.5-0.6\mu\textrm{m}$/min at $2A/dm^2$ and the particle size increased with increasing current density. The resistivities of electro-deposited copper films were about $3-6{\mu}{\Omega}{\cdot}$cm for the particle size above $4000{\AA}$. By the addition of 0.2 g/l gelatin, the particle size was reduced to less than $0.1{\mu}m $ and selective plugging of copper on submicron contacts could be successfully achieved.

  • PDF

Effects of Cavity Configuration on Bond Strength and Microleakage of Composite Restoration (와동의 형태에 따른 복합레진의 결합강도 및 변연누출에 관한 연구)

  • Choi, Seung-Mo;Choi, Gi-Woon;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.479-487
    • /
    • 2002
  • 복합레진의 중합시 발생하는 수축과 응력은 와동의 형태에 의하여 영향을 받으며 이는 수복재는 물론 접착계면의 물성을 결정하는 요인이 된다. 본 연구는 다양한 C-factor를 갖는 와동에 상아질 접착제 Clearfil SE Bond(Kuraray)를 도포하고 혼합형 복합레진인 Clearfil AP-X(Kuraray)와 미세혼합형의 Esthet-X(Dentsply)를 충전하여 미세인장강도 및 변연누출을 측정 평가함으로써 중합수축이 수복물과 치아계면에 미치는 영향을 평가하고자 시행하였다. 98개의 Bovine 하악전치를 이용하여 표면의 상아질을 #600 SiC paper로 연마한 대조군 및 와동의 넓이를 조절하여 C-factor 2.3, 3.0, 3.7이 되도록 제작한 실험군 와동에 복합레진을 충전한 후 37의 증류수에 24시간 보관하였다. 저속 diamond saw(Buehler)를 이용하여 1mm 두께로 수직절단 후 고속 diamond point(#104 Shofu)를 이용하여 단면적 1mm$^2$가 되도록 hour-glass모양으로 형성하여 시편을 제작하였고, Universal testing machine(EZ-Test; Shimadzu, Japan)에 시편을 부착하고 cross head speed 1mm/min으로 인장력을 가하여 미세인장 결합강도를 측정하였다. 각 C-factor에 따른 변연누출실험을 위하여 복합레진이 수복된 치아를 37$^{\circ}C$의 증류수에 24시간 보관한 후 와동을 제외한 부위에 nail varnish를 도포하고 3mol/L silver nitrate용액에 24시간 암보관한 다음 수세하여 현상액에 24시간 경과시킨 후 치아의 장축에 따라 절단하여 침투된 색소의 정도를 광학현미경상에서 40배로 관찰하였다. 각각의 실험결과는 ANOVA/Tukey's test 및 Kruskal-Wallis non-parametric independent analysis와 Mann-Whitney U test에 의하여 통계 분석하여 다음과 같은 결론을 얻었다. 1. 대조군에 있어서 혼합형 복합레진의 미세인장 결합강도는 미세혼합형에 비하여 높았으며, 실험군 사이에는 유의차를 보이지 않았다. 2.모든 복합레진의 미세인장 결합강도는 와동의 C-factor증가에 따라 감소하는 경향을 나타내었고, 혼합형 복합레진의 실험군은 대조군에 비하여 낮게 나타났으며, 미세혼합형 복합레진에서는 유의차를 보이지 않았다. 3. 절단측 및 치은측 변연부의 미세누출정도는 혼합형 복합레진이 미세혼합형에 비하여 대체로 높게 나타났다. 4. 모든 실험군에서 미세누출은 C-factor증가에 따라 증가하였고 절단측에 비하여 치은측 변연이 높게 나타났으나 통계학적 유의차는 보이지 않았다. C-factor의 변화에 대하여 필러함량과 탄성계수가 높은 혼합형 복합레진이 미세혼합형에 비하여 더 민감한 결과를 보인다. 이는 복합레진 수복시 재료의 선택과 중합수축의 적절한 조절이 중요한 요소임을 시사한다.

The effect of MTAD as a final root canal irrigants on the coronal bacterial leakage of obturated root canals (최종 근관세척제로서의 MTAD 근관세척제가 치관부 세균미세누출에 미치는 영향)

  • Kim, Tae-Woo;Chang, Seok-Woo;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.397-404
    • /
    • 2008
  • The purpose of this study was to evaluate the effects of MTAD, EDTA and sodium hypochlorite(NaOCl) as final irrigants on coronal leakage resistance to Enterococcus faecalis. Forty extracted human maxillary molars were used in this experiment. The teeth were randomly divided into positive control group (Group 1; n = 5), negative control group (Group 2; n = 5) and three experimental groups (n = 30). In Group 3 (n = 10), the root canals were irrigated with sodium hypochlorite. In Group 4 (n = 10) and 5 (n = 10), the root canals were irrigated with sodium hypochlorite and rinsed with EDTA and MTAD, respectively. The teeth in each group were cleaned and shaped to #40 profile with .04 taper, and obturated with gutta-percha and AH-26 root canal sealer. The coronal portion of each tooth was placed in contact with inoculum of Enterococcus faecalis in Brain Heart Infusion (BHI) culture media. Each root tip was placed in a vial containing sterile culture media. The vials were placed in anaerobic chamber and observed everyday for turbidity for 180 days. Statistical analysis was performed using Fisher's Exact Test. After 180 days, Group 3, 4, and 5 showed 7, 4 and 5 leaking samples respectively. The differences in leakage resistance were not statistically significant among Group 3, 4 and 5.

Studies on the Distillation Operation of Baikha-ju (백하주의 증류조작에 관한 연구)

  • Min, Young-Kyoo;Yun, Hyang-Sik;Jeong, Heon-Sang
    • Applied Biological Chemistry
    • /
    • v.37 no.1
    • /
    • pp.9-13
    • /
    • 1994
  • Baikhaju, the traditional Korean rice wine was brewed and distilled at various conditions-at different pressure (760, 460, 260 mmHg), different reflux ratio (3.1 : 1, 1 : 1) and different column conditions (packed and unpacked), and distillation operation was investigated. The sample wine, Baikhaju showed alcohol content of 14.2%, acidity 8.3 (g/100 ml), ethyl acetate 49 ppm, fusel oil 657 ppm. As the distillation was proceeded, alcohol concentration of distillate was decreased and that was higher in atmospheric pressure rather than reduced pressure. When the pressure was increased, the slope showed the relation of alcohol concentration between still liquid and vapour was increased, and also as the reflux ratio was increased, alcohol concentration of distillate was increased, and that was 0.56 mole at the reflux ratio 3.1 : 1 at atmospheric pressure, where 0.54 mole at 1 : 1 reflux ratio. As the distillation was proceeded, the rate of distillation was decreased, and that was higher values in the reduced pressure than atmospheric pressure. The maximum value (0.14 ml/s) of rate of distillation was observed in the packed column at 260 mmHg. As the reflux ratio was increased, the rate of distillation was decreased, and that was 0.05 ml/sec at reflux ratio 3.1 : 1 at atmospheric pressure, where 0.06 ml/sec at 1 : 1 reflux ratio.

  • PDF