• Title/Summary/Keyword: 최소침습수술

Search Result 142, Processing Time 0.024 seconds

Routine Off-pump Total Arterial Coronary Revascularization (심폐바이때스 없이 시행된 동맥 도관만를 이용한 관상동맥 완전 재관혈화)

  • Lee, Jae-Won;Park, Nam-Hee;Kang, Seong-Sik;Choo, Suk-Jung;Park, Seung-Jung;Park, Seung-Wook;Hong, Myeong-Ki;Song, Hyun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.309-315
    • /
    • 2003
  • Background: To avoid the adverse effects of cardiopulmonary bypass and to overcome late vein graft failure we routinely peformed off-pump total arterial coronary revascularization. Material and Method: From July 2000 to August 2001, 104 consecutive patients underwent first elective off-pump total arterial coronary revascularization. Both internal mammary, radial and gastroepiploic arteries were used. Sequential and composite grafts were used to achieve complete revascularization. Perioperative adverse events and postoperative angiograms were analyzed. Result: A total of 252 arterial conduits were used with an average of 2.47 grafts per patient. A total of 326 distal anastomosis were performed with a mean of 3.13 distal anastomosis per patient. Cross over to on-pump occurred in seven patients (6.7%). Of these 4 were due to unstable hemodynamics during lateral or posterior wall stabilization as a result of cardiomegaly and 3 were due to uncontrolled bleeding during dissection of diffusely dimunitive deeply placed intramyocardial coronary arteries. There were no opeartive deaths. Two cases of perioperative myocardial infarction and transient neurologic complications occurred, respectively. Of the 312 distal anastomoses, 308 (98.7%) were compatible with Fitz-Gibboll A or B patency grading. Conclusion: Off-pump total arterial coronary revascularization was technically feasible in most elective cases with satisfactory early results. However, on-pump coronary bypass surgery should be considered in difficult circumstances, such as cardiomegaly or unfavorable anatomy of the target coronary artery.

Feasibility Study of Laparoscopic Gastrostomy Tube Placement in Beagle Dogs (비글견에서 복강경을 이용한 위관삽입술의 유용성 평가 연구)

  • Lee, Jae-Woong;Park, Ji Young;Lee, Hae-Beom;Jeong, Seong Mok
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • Aim of this study is demonstrate the feasibility of Laparoscopic gastrostomy (LG) tube placement in dogs by comparing with percutaneous endoscopic gastrostomy (PEG) tube placement, based on operative time, complications and gastro-peritoneal adhesion evaluation. Eight intact male beagle dogs were used in this study. Tri-Funnel Replacement Gastrostomy tube (Bard Inc., USA) of 20 Fr was used for LG technique and PEG kit (Ponsky "Pull" PEG Kit$^{(R)}$, Bard Inc., USA) with soft silicone retention dome consisting of a 20 Fr gastrostomy tube was used. Feeding via gastrostomy tube was performed in two weeks, maintenance energy requirement (MER) divided into 3 separate feeding. LG and PEG were evaluated at intraoperative, postoperative and postmortem period. Mean operative time for the PEG group was significantly shorter when compared with the LG group (p < 0.05). Successful maintenance of gastrostomy tube was confirmed in all dogs. Gastric and peritoneal wall adhesions were formed successfully in each group. The mean adhesion length (AL) and width (AW) were significantly larger in LG group compared with in PEG group (p < 0.05). The mean adhesion distance (AD) was not significantly different between two groups (p = 0.182). Consequently, LG is an effective minimally invasive, safe and easy to perform technique for providing enteral nutritional support in dogs.

The Open Surgical Treatment for Stiff Elbow (주관절 구축의 관혈적 치료)

  • Lee, Ji-Ho;Ra, In-Hoo;Jeon, In-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.293-298
    • /
    • 2010
  • Purpose: Since an injured elbow joint can disturb the activity of daily life by limiting motion, especially if the motion is restricted over 40 degree of flexion contracture and under 105 degree of further flexion, it is imperative to select the best method and the timing of treatment of the elbow stiffness. Therefore this review will discuss open surgical techniques for stiff elbows based on the literature. Materials and Methods: It is important to take sufficient clinical examination of the patient, including history taking. And, a surgeon should select appropriate procedure after accurately understanding about the status and cause of the stiff elbow with radiographic methods. Surgical methods include arthroscopic release open release, distraction arthroplasty, total elbow replacement and there are four approachs in the open release - anterior approach, medial "over the top" approach, limited lateral approach: column procedure, posterior extensile approach-. Results and Conclusion: Although at present the arthroscopic technique is emphasized for the treatment of elbow stiffness, a surgeon should know conventional open techniques.

Dorsal Mini-thoracotomy for PDA Closure in Premature Neonates (후방 소개흉술을 통한 미숙아 동맥관 개존증의 수술요법)

  • Lee, Hyang-Lim;Choi, Chang-Hyu;Son, Dong-Woo;Shim, So-Yeon;Park, Kook-Yang;Park, Chul-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.434-440
    • /
    • 2009
  • Background: Surgical closure of a patent ductus arteriosus (PDA) can be considered when conservative medical treatment is ineffective or contraindicated. Low weight and earlier gestational age neonates who are treated with conservative medical therapy generally showed a higher failure rate. The morbidity of surgical PDA closure in such extremely low birth weight (ELBW) neonates is also high. Here we present the early results of a new technique for approaching the PDA through a dorsal minithoracotomy. Material and Method: From March 2006 to November 2008, 24 premature neonates underwent surgical PDA closure. The procedures were performed in the newborn intensive care unit via a 2 cm long dorsal minithoracotomy with the baby in the prone position with the left hemithorax elevated 30$^{\circ}$. Bimanual cotton swab blunt dissection completed the extrapleural accesstothe PDA and then two clips were applied. Tube thoracostomy was avoided if there was no meaningful pleural laceration. Result: The infants mean gestational age was 26.5$\pm$2.1 weeks (range: 23 to 30 weeks) and the average age at operation was 11$\pm$11 days. The mean body weight at operation was 933$\pm$271 grams (range: 570 to 1,700 grams). Eight patients expired, but there was no procedure-related death. Postoperative echocardiography revealed two cases of residual shunt but none of these shunts were detected on the follow up echocardiogram that was performed on the post operative 5 and 59 days. Conclusion: We concluded that the technique described here is an effective procedure in view of the satisfactory operative exposure and the low rate of complications.

Clinical Usefulness of a Totally Laparoscopic Gastrectomy (전(全)복강경하 위절제술의 임상적 유용성)

  • Kim, Jin-Jo;Kim, Sung-Keun;Jun, Kyong-Hwa;Kang, Han-Chul;Song, Kyo-Young;Chin, Hyung-Min;Kim, Wook;Jeon, Hae-Myung;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Park, Woo-Bae;Kim, Seung-Nam
    • Journal of Gastric Cancer
    • /
    • v.7 no.3
    • /
    • pp.132-138
    • /
    • 2007
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been on the increase. Although minimally invasive surgery is more beneficial, no reported case of a total laparoscopic gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experience, to determine the safety and feasibility of a total laparoscopic gastrectomy with various types of intracorporeal anastomosis using laparoscopic linears stapler in treating early gastric carcinomas. Materials and Methods: We investigated the surgical results and clinicopatholgical characteristics of 81 patients that underwent a totally laparoscopic distal gastrectomy at our department between June 2004 and May 2007. The intracorporeal anastomoses were performed by using laparoscopic linear staplers. Results: The mean operative time was 287 minutes, the mean anastomotic time was 40 minutes, and the mean number of laparoscopic linear staplers used for an operation was 7.5. The mean time to the first flatus, the first food intake, and discharge from hospital was 2.9, 3.6, and 10.3 days respectively. There were 11 cases of postoperative complications, but no case of postoperative mortality or conversion to an open procedure. In 75 patients with an adenocarcinoma, the mean number of lymph nodes harvested was 38.1 and the stage distribution was as follows: stage I, 72 patients; stage II, 2 patients; stage IV, 1 patient. During the mean follow-up period of 14 months, 5 patients died of other causes and there were no cases of cancer recurrence. Conclusion: A total laparoscopic gastrectomy with intracorporeal anastomosis by using a laparoscopic linear stapler was found to be safe and feasible. We were able to obtain acceptable surgical outcomes in terms of minimal invasiveness.

  • PDF

Redo CABG Using Various Arterial Grafts (다양한 동맥도관을 이용한 재관상동맥 우회술)

  • Min, Ho-Ki;Lee, Young-Tak;Lee, Min-A;Kim, Wook-Sung;Park, Pyo-Won;Sung, Ki-Ick;Jun, Tae-Gook;Yang, Ji-Hyuk
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.456-463
    • /
    • 2009
  • Background: Although the reports on re-operative coronary revascularization (redo-CABG) have increased, there are only limited reports on redo-CABG using arterial grafts. The aim of this study was to analyze the safety and feasibility of using various arterial grafts for redo-CABG. Material and Method: A consecutive series of patients who underwent 33 redo-CABGs from March 2001 to July 2008 were retrospectively reviewed. We performed conventional CABG in 17 patients, on-pump beating CABG in 7, off-pump CABG in 7 and minimally invasive direct coronary artery bypass in 2. The grafted that were used included 34 internal thoracic arteries (ITA), 14 radial arteries, 14 right gastroepiploic arteries and others. Arterial composite grafts were constructed in 26 patients. Of these, a previously patent in-situ left ITA was re-used as the in-flow of a composite graft in 10 patients. Result: No hospital deaths or major wound problems occurred. The post-operative complications included 2 myocardial infarctions (6%), 1 intra-aortic balloon pump insertion (3%), 5 cases of atrial fibrillation (15.1 %) and 3 neurologic complications (9.1%). The meanfollow-up duration was 31.1$\pm$22.7 months and the 3 year survival rate was 86.4%. There were 4 late deaths (2 cardiac deaths) and no recurrent angina during the follow-up period. Conclusion: Redo-CABG with using various arterial grafts is currently a safe, feasible procedure, but further investigation and long term follow-up are needed.

The Evaluation of Non-Coplanar Volumetric Modulated Arc Therapy for Brain stereotactic radiosurgery (뇌 정위적 방사선수술 시 Non-Coplanar Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Doo Sang;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.9-16
    • /
    • 2018
  • Purpose : Brain Stereotactic Radiosurgery can treat non-invasive diseases with high rates of complications due to surgical operations. However, brain stereotactic radiosurgery may be accompanied by radiation induced side effects such as fractionation radiation therapy because it uses radiation. The effects of Coplanar Volumetric Modulated Arc Therapy(C-VMAT) and Non-Coplanar Volumetric Modulated Arc Therapy(NC-VMAT) on surrounding normal tissues were analyzed in order to reduce the side effects caused fractionation radiation therapy such as head and neck. But, brain stereotactic radiosurgery these contents were not analyzed. In this study, we evaluated the usefulness of NC-VMAT by comparing and analyzing C-VMAT and NC-VMAT in patients who underwent brain stereotactic radiosurgery. Methods and materials : With C-VMAT and NC-VMAT, 13 treatment plans for brain stereotactic radiosurgery were established. The Planning Target Volume ranged from a minimum of 0.78 cc to a maximum of 12.26 cc, Prescription doses were prescribed between 15 and 24 Gy. Treatment machine was TrueBeam STx (Varian Medical Systems, USA). The energy used in the treatment plan was 6 MV Flattening Filter Free (6FFF) X-ray. The C-VMAT treatment plan used a half 2 arc or full 2 arc treatment plan, and the NC-VMAT treatment plan used 3 to 7 Arc 40 to 190 degrees. The angle of the couch was planned to be 3-7 angles. Results : The mean value of the maximum dose was $105.1{\pm}1.37%$ in C-VMAT and $105.8{\pm}1.71%$ in NC-VMAT. Conformity index of C-VMAT was $1.08{\pm}0.08$ and homogeneity index was $1.03{\pm}0.01$. Conformity index of NC-VMAT was $1.17{\pm}0.1$ and homogeneity index was $1.04{\pm}0.01$. $V_2$, $V_8$, $V_{12}$, $V_{18}$, $V_{24}$ of the brain were $176{\pm}149.36cc$, $31.50{\pm}25.03cc$, $16.53{\pm}12.63cc$, $8.60{\pm}6.87cc$ and $4.03{\pm}3.43cc$ in the C-VMAT and $135.55{\pm}115.93cc$, $24.34{\pm}17.68cc$, $14.74{\pm}10.97cc$, $8.55{\pm}6.79cc$, $4.23{\pm}3.48cc$. Conclusions : The maximum dose, conformity index, and homogeneity index showed no significant difference between C-VMAT and NC-VMAT. $V_2$ to $V_{18}$ of the brain showed a difference of at least 0.5 % to 48 %. $V_{19}$ to $V_{24}$ of the brain showed a difference of at least 0.4 % to 4.8 %. When we compare the mean value of $V_{12}$ that Radione-crosis begins to generate, NC-VMAT has about 12.2 % less amount than C-VMAT. These results suggest that if NC-VMAT is used, the volume of $V_2$ to $V_{18}$ can be reduced, which can reduce Radionecrosis.

  • PDF

Clinical Results of 100 Cases of Coronary Artery Bypass Grafting without Cardiopulmonary Bypass (심폐바이패스 없이 시행한 관상동맥 우회술 100예의 임상적 고찰)

  • 방정희;우종수
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.322-327
    • /
    • 2004
  • Coronary artery bypass grafting on the beating heart is no longer a new methods for any cardiac surgeon. We evaluated the application of the off-pump coronary artery bypass procedure relative to safety and efficiency as measured by postoperative complication and operative mortality. Material and Method: We used our retrospective database to compare the patients having off-pump coronary surgery (n=100) with those having on-pump coronary surgery (n=100) between June, 1999 and August, 2002. Patients whom underwent associated valvular or aortic aneurysmal operation were excluded. Result: Neither groups showed any differences in the patient's risk factors and extent of coronary disease. Off-pump CABG group did not have significantly less mean operation time (295$\pm$73 min vs 323$\pm$83 min, p=ns) and mean hospital day (15.34$\pm$6.02 day vs 13.80$\pm$4.95 day, p=ns). However, off-pump CABG group had significantly shorter mean ventilation time (17.3$\pm$11.27 hour vs 24.98$\pm$16.1 hour, p<0.05). No patients were converted to on-pump CABG in off-pump CABG. Intraoperative hemodynamic instability in off-pump CABG were 6 cases, of whom 2 cases were in lateral wall approach and 4 cases in right coronary anastomosis. Postoperative mortality was 1 case in off-pump CABG and 2 cases in on-pump CABG. Intra-aortic ballon pump (IABP) was applied in 1 case with off-pump CABG and in 2 cases with on-pump CABG. No patients presented postoperative cerebral infarction & stroke in off-pump CABG but 2 patients in on-pump CABG. Postoperative arrhythmia presented in 4 cases with off-pump CABG and in 6 cases with on-pump CABG. Acute renal failure (ARF) was complicated in 3 cases with off-pump CABG and in 2 cases with on-pump CABG. Conclusion: This study documented the immediate safety and efficiency of the off-pump CABG procedure.

Clinical Results Following T3, 4 vs T3 Thoracoscopic Sympathicotomy in 30 Axillary Hyperhidrosis Patients (겨드랑이 다한증 환자에서 흉부교감신경의 차단부위(T3-4와 T4)에 따른 임상결과)

  • Choi, Soon-Ho;Lee, Sam-Youn;Lee, Mi-Kyung;Cha, Byoung-Ki
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.469-475
    • /
    • 2008
  • Background: Video-assisted thoracic sympathicotomy is a definitive minimally invasive treatment for axillary hyperhidrosis. Different techniques exist for controlling axillary hyperhidrosis, but they are temporary and expensive. We compared the results after using two different levels of sympathicotomy for treating axillary hyperhidrosis: T3-T4 and T4. Material and Method: Between June 2002 and May 2007, 30 patients with isolated axillary hyperhidrosis underwent either T3-T4 or T4 thoracoscopic sympathicotomy in the Department of Thoracic & Cardiovascular Surgery at Wonkwang University Hospital. The patients were divided into two groups. Group I (n=15) was composed of patients who underwent T3-T4 sympathicotomy (thermal ablation), and Group II (n=15) was composed of patients who underwent T4 sympathicotomy (thermal ablation). The procedures were bilateral and simultaneous, involving the use of two 2-mm trocars and a 0-degree 2-mm thoracoscope under general anesthesia with single endotracheal intubation. Outcome parameters included satisfaction rate of treatment, degree of compensatory sweating, and postoperative complications. Patients were interviewed by telephone regarding satisfaction and compensatory hyperhidrosis. Result: There were no differences in age between group I and group II. The mean follow-up for the T3-T4 group was $38.7{\pm}2.3$ months, and the mean follow-up for the T4 group was $18.7{\pm}3.6$ months. The immediate therapeutic success rate (within 2 weeks postoperative) was 100% in both groups, and there were no recurrences in either group during the long-term follow-up period. The satisfaction rate was higher (93.3%) in the T4 group than in the T3-T4 group (53.3%), and the incidence of compensatory hyperhidrosis was lower in the T4 group (6.7%) than in the T3-T4 group (46.7%). Postoperative complications included one mild pneumothorax and two instances of intercostal neuralgia. Digital infrared thermographic imaging (DITI) correlated well with postoperative satisfaction. Conclusion: Both techniques proved effective for controlling isolated axillary hyperhidrosis. The T4 group had a higher satisfaction rate and lower severity of compensatory hyperhidrosis. Hence, thermal ablation of the lower interganglionic fibers of the third thoracic sympathetic ganglion on the fourth rib is a more practical and minimally invasive treatment than is the T3-T4 surgical method, according to the degree of compensatory sweating in isolated axillary hyperhidrosis.

Comparative Study of Sterilization by Gamma-ray and Electron-Beam (감마선, 전자선에 의한 멸균 비교분석)

  • Jeong, Kyeonghwan;Park, Changhee
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.537-543
    • /
    • 2020
  • The elderly population in the modern society is growing rapidly due to advance medical technology and minimally invasive surgery. Therefore, as the tendency to use medical device is increasing, pathogenic infection is a concern. Therefore, the first aim of modern medicine is infection prevention in medical place. Recently, patient implants are increasing using 3D printing. Hydroxyapatite is used as a representative material. And, there haven't had currently absorbed dose standard for sterilization of hydroxyapatite discs. Escherichia coli and Streptococcus mutans contaminated on the surface of hydroxyapatite discs were irradiated at each absorbed dose of 0, 0.5, 1.0, 3.0, 5.0 kGy using Gamma-ray of cobalt and Electron-beam of linear accelerator. Then, the number of bacteria was measured in the sample by the decimal dilution method. After sterilization, a non-parametric testing method was performed to compare the survival of Escherichia coli and Streptococcus mutans. As a result, Escherichia coli was sterilized at 1 kGy or more and Streptococcus mutans at 3 kGy or more on absorbed dose. It is considered possible to perform sterilization at a lower value than the recommended absorbed dose of radiation sterilization.