• Title/Summary/Keyword: 최대 제거 토크

Search Result 13, Processing Time 0.021 seconds

Effect of dual pitch mini-implant design and diameter of an orthodontic mini-implant on the insertion and removal torque (교정용 미니임플랜트의 이중 피치와 직경의 차이가 삽입 및 제거 토크에 미치는 영향 평가)

  • Kim, Jong-Wan;Cho, Il-Sik;Lee, Shin-Jae;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.275-283
    • /
    • 2006
  • Objective: Small orthodontic mini-implants are useful as anchorage. However they have some weaknesses such as loosening. This study was carried out to analyze the mechanical effects of the dual pitch and diameter on the insertion and removal torque of mini-implants. Methods: The threads of mini-implants were mono and dual pitch. The diameters of mini-implants were 1.4 mm and 1.6 mm. Four groups were tested (mono 1.4 mm, mono 1.6 mm, dual 1.4 mm and dual 1.6 mm). All were inserted and removed on polyurethane foam with the torques being measured. Results: The maximum torque of the dual pitch groups was higher than the mono pitch groups during removal but lower during insertion. The maximum torque of the 1.6 mm diameter groups was higher than the 1.4 mm diameter groups during insertion and removal. The dual pitch 1.4 mm group showed the lowest insertion torque but had similar or superior levels of removal torque to that of the mono pitch 1.6 mm group. Conclusions: The dual pitch especially showed a continuous high removal torque after the peak. Despite the small diameter, the dual pitch might improve the initial mechanical stability.

Comparison of histologic observation and insertional and removal torque values between titanium grade 2 and 4 microimplants (Grade 2, 4 티타늄 마이크로 임플랜트의 식립 및 제거 토크와 식립 후 조직학적 반응의 비교)

  • Kang, Sung-Taek;Sung, Jae-Hyun;Kyung, Hee-Moon;Park, Hyo-Sang;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.171-177
    • /
    • 2006
  • The purpose of this study was to evaluate the light microscopic features and the maximum insertional and removal torque value of microimplants, made from titanium grade 2 or 4, in the tibia of 6 rabbits. First, the maximum torque values of microimplants at implantation were measured. After 2, 8, and 12 weeks of healing time, the microimplant-containing segments of tibia of 2 rabbits were removed and the maximum removal torque of each microimplant were measured. Comparisons of histologic examination and insertional and removal torque values were carried out for the two groups of microimplants. Removal torque values were significantly increased in both groups after 8 and 12 weeks as compared to 2 weeks after implantation. Other values measured did not show any statistically significant differences and there were no histological differences between grade 2 and 4 titanium. Based on these results, this study showed that there were no significant differences between grade 2 and 4 titanium. It seems better to use grade 4 titanium for making microimplants because grade 4 titanium is mechanically harder than grade 2 titanium and has similar retention.

Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants (교점용 미니 임플랜트의 cutting flute의 길이 및 형태에 따른 식립 및 제거 토크의 비교)

  • Yun, Soon-Dong;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.95-104
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the effect of length and shape of cutting flute on mechanical properties of orthodontic mini-implants. Methods: Three types of mini-implants with different flute patterns (Type A with 2.6 mm long flute, Type B with 3.9 mm long and straight flute, Type C with 3.9 mm long and helical flute) were inserted into the biomechanical test blocks (Sawbones Inc., USA) with 2 mm and 4 mm cortical bone thicknesses to test insertion and removal torque. Results: In 4 mm cortical bone thickness, Type C mini-implants showed highest maximum insertion torque, then Type A and Type B in order. Type C also showed shortest total insertion time and highest maximum removal torque, but Type A and B didn't showed statistically significant difference in insertion time and removal torque. In 2 mm cortical bone thickness, there were no significant difference in total insertion time and maximum removal torque in three types of mini-implants, but maximum insertion torque of Type A was higher than two other Types of mini-implants. Conclusions: Consideration about length and shape of cutting flute of mini-implant is also required when the placement site has thick cortical bone.

Torque Optimizing Control of Redundant Manipulators (여유자유도 로봇을 위한 최적토크제어)

  • Lee, Bo-Hyun;Lee, Kee-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.758-760
    • /
    • 2000
  • 본 논문에서는 기구적으로 여유자유도를 갖는 로봇 매니퓰레이터 시스템을 대상으로 하여, 로봇 랜드가 주어진 제적을 추종할 수 있는 관절 토크를 유도하기 위한 동적제어 식을 새로이 구성하고, 동적제어식을 만족하는 관절 토크 해들 중에 국소적으로 토크의 크기를 최적화하는 해를 사용하는 최적토크제어를 제안한다. 최적토크를 구하는 문제에 있어 관절 토크에 가중치 행렬을 적용하여 각 관절 토크의 최대 크기의 비를 반영할 수 있도록 한다. 또한, 로봇 핸드 자코비안-관성 역행렬의 영공간에서 나타나는 영공간 관절 속도를 정의하고 이러한 영공간 관절속도가 최적토크제어에서는 로봇 시스템을 불안정하게 할 수 있다는 것을 보인다. 최적토크 제어의 이러한 문제를 해결하기 위하여 영공간 관절 속도를 제거하기 위한 소산토크를 유도하고, 최적토크제어식에 소산토크를 추가하는 방법을 제안한다. 평면형 3-자유도 로봇을 대상으로 한 모의실험을 통해 제안된 제어 방법의 우수성을 검증하고 그 결과를 분석한다.

  • PDF

MINISCREW STABILITY REGARDING DESIGN OF MINISCREW AND THICKNESS OF CORTICAL BONE (교정용 미니스크류의 디자인과 피질골의 두께에 따른 역학적 안정성 평가)

  • Kweon, Young-Sun;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.250-259
    • /
    • 2011
  • The aim of this study was to suggest a design for an orthodontic miniscrew which may work most favorably in the thin cortical bone of the adolescent. In this study, orthodontic miniscrews with different diameters, lengths, and body types were manufactured and implanted in two artificial bone samples with different cortical bone thickness. Maximum insertion torque, maximum removal torque, and lateral alteration torque were measured. As a result, the bone quality, body type, diameter, and the length all had their effects on the maximum insertion torque, maximum removal torque, and lateral alteration torque. Cortical bone thickness was the most important factor. In initial stability, conical types showed better results than cylindrical types. Increase in the diameter had favorable effects in achieving mechanical stability. Increase in the length did not have as much influence as the other factors did on the initial stability, but there was a statistically significant difference between screws of 6 mm and 8 mm lengths(p<0.05). In conclusion, the conical type screw with a diameter of 1.8 mm is most favorable in the thin cortical bone of the adolescent. In terms of length, the 8 mm screw is expected to perform better than the 6 mm screw.

Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants (Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교)

  • Park, Hyo-Sang;Yen, Shue;Jeoung, Seong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.295-307
    • /
    • 2006
  • Objective: The purpose of this study was to compare the histological and biomechanical characteristics of self-tapping and self-drilling microscrew implants. Methods: 112 microscrew implants (56 self-drilling and 56 self-tapping) were placed into the tibia of 28 rabbits. The implants were loaded immediately with no force, light (100 gm), or heavy force (200 gm) with nickel-titanium coil springs. The animals were sacrificed at 3- and 5-weeks after placement and histologic and histomorphometric analysis were performed under a microscope. Results: All microscrew implants stayed firm throughout the experiment. There was no significant difference between self-drilling and self-tapping microscrew implants both in peak insertion and removal torques. Histologic examinations showed there were more defects in the self-tapping than the self-drilling microscrew implants, and newly formed immature bone was increased at the interface in the self-tapping 5-week group. There was proliferation of bone towards the outer surface of the implant and/or toward the marrow space in the self-drilling group. Histologically, self-drilling microscrew implants provided more bone contact initially but the two methods became similar at 5 weeks. Conclusion: These results indicate the two methods can be used for microscrew implant placement, but when using self-tapping microscrew implants, it seems better to use light force in the early stages.

Maximum Torque Operation of IPMSM Drives for the Next Generation High Speed Railway System (차세대 고속전철에 적용되는 IPMSM 구동 시스템의 최대 토크제어)

  • Jin, Kang-Hwan;Kim, Sung-Je;Yi, Du-Hee;Kwon, Soon-Hwan;Kim, Yoon-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.493-499
    • /
    • 2010
  • The next generation domestic high speed railway system is a power dispersed type and uses vector control method for motor speed control. Nowadays, inverter driven induction motor system is widely used. However, recently PMSM drives are deeply considered as a alternative candidate instead of an induction motor driven system due to their advantages in efficiency, noise reduction and maintenance. In this paper, the maximum torque control approach is presented for the IPMSM drives with reluctance torque. The applied control method uses maximum torque control per ampere technique. Simulation programs based on Matlab/Simulink are developed. Finally the designed system is verified by simulation and their characteristics are analyzed by the simulation results.

Mechanical analysis of the taper shape and length of orthodontic mini-implant for initial stability (교정용 미니임플랜트의 초기 안정성에 대한 원추형태와 길이에 관한 기계역학적 분석)

  • Kim, Jong-Wan;Cho, Il-Sik;Lee, Shin-Jae;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.55-62
    • /
    • 2006
  • Orthodontic mini-implants, despite its usefulness as anchorage, have some limits such as loosening. Therefore, various shapes and lengths have been studied. The aim of this study is to analyze the shape and length of mini-implants mechanically. The shapes of mini-implants (1.6 mm, Dual Top, Jeil Medical Co., Seoul, Korea) were cylindrical and taper. The lengths of mini-implants were 6 mm and 8 mm. The tested groups were 5 groups (cylindrical 6 mm, cylindrical 8 mm, taper 6 mm, taper 8 mm and taper 8 mm modified whose thread is reduced from the middle to upper part). All were inserted and removed on the polyurethane foam with the torque measured. During insertion and removal, the taper shape needed higher torque than the cylindrical shape, and the 8 mm length than the 6 mm length (p<0.001). The taper 6mm group showed superior insertion torque (p<0.001) and similar removal torque to the cylindrical 8 mm group. The taper 8 mm modified group with gradually reduced threads, showed continuous high removal torque after the peak. The initial mechanical stability can be provided by the tapered shape and also, affected by length and thread design.

Position estimation improvement of IPMSM Sensorless Control by Suppression of Harmonics (고조파 제거를 통한 IPMSM의 센서리스 제어에서의 위치추정 성능 개선)

  • An, Min-Hyuk;Yoo, Ji-Yoon;Lee, Kwang-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.100-102
    • /
    • 2009
  • 밴드패스필터를 사용하여 센서리스 벡터제어에 영향을 주는 6차고조파 성분을 제거하여 안정적인 제어를 제안하였다. 비정현적인 역기전력을 가진 IPMSM모터의 센서리스 벡터 제어에서 유기전압에 고조파가 포함되는 경우에 그 영향이 추정연산에 나타나게 된다. 삼상 모델에 나타나는 5차, 7차 고조파의 경우는 d, q축 모델로 변환 시 6차 고조파 성분으로 나타나게 된다. 이 6차 고조파 성분은 위치 추정과 속도추정에 영향을 주어서 토크 맥동을 발생시킨다. 본 논문에서는 이러한 6차 고조파의 영향으로 추정연산에 미치는 영향들을 알아보고. 이 영향을 고조파 제거를 위한 복잡한 계산을 하지 않으면서 간단한 밴드패스필터를 통해 고조파가 위치추정에 미치는 영향을 최대한 줄이는 방법을 제시하였다.

  • PDF

Development of An Onion Peeler (II) - Root Cutting Equipment - (양파박피기 개발 (II) - 양파뿌리 부 절단장치 -)

  • 민영봉;김성태;김정호;최선웅;유준현
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.573-578
    • /
    • 2002
  • 양파박피기 개발을 목적으로 수행된 본 연구에서는 공정상 필요한 뿌리절단장치에 관하여 시험 분석하였다. 뿌리를 절단, 제거하는 데 적합한 칼날의 종류, 회전속도와 이송속도, 및 소요동력 등 제 특성을 구명하여 적절한 회전칼날을 제작 사용함으로써 능률 높은 양파박피기를 개발하고자 수행한 결과를 요약하면 다음과 같다. 1. 양날형, 축날형, 원추형, 및 원통형 등 직경 30 mm의 칼날을 제작하여 실험하였던 바, 양파의 뿌리절단에는 구부린 칼날로 파내기를 하고 수직칼날로 금긋기를 동시에 할 수 있는 양날형이 가장 좋은 것으로 나타났다. 2. 양파의 뿌리부가 100% 절단이 되고 소요동력이 낮으면서 절단시간을 단축할 수 있는 최적의 작동조건은 칼날의 무부하 회전수 630 rpm, 이송속도 0.08 m/s인 것으로 나타났고, 그때의 최대토크는 5.25 kg·cm이었으며 최대소요동력은 33W로 나타났다.

  • PDF