Mechanical analysis of the taper shape and length of orthodontic mini-implant for initial stability |
Kim, Jong-Wan
(Department of Orthodontics, Seoul National University Dental Hospital)
Cho, Il-Sik (Department of Orthodontics, Seoul National University Dental Hospital) Lee, Shin-Jae (Department of Orthodontics, Seoul of Dentistry and Dental Research Institute, Seoul National University) Kim, Tae-Woo (Department of Orthodontics, Seoul of Dentistry and Dental Research Institute, Seoul National University) Chang, Young-Il (Department of Orthodontics, Seoul of Dentistry and Dental Research Institute, Seoul National University) |
1 | Linkow LI. The endosseous blade implant and its use in orthodontics. Int J Orthod 1969:24:149-54 |
2 | Park HS. A new protocol of the sliding mechanics with Micro -implant Anchorage (MIA). Korean J Orthod 2000:30:677-85 과학기술학회마을 |
3 | Costa A, Raffainl M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon Orthognath Surg 1998:13:201-9 |
4 | Himmlova L, Dostalova T, Kacovsky A, Konvickova S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthot Dent 2004:91:20-5 DOI ScienceOn |
5 | Hermann I, Lekholm D, Holm S, Kultie C. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. Int J Oral Maxillofac Implants 2005;20:220-30 |
6 | Zdeblick TA, Kunz DN, Cooke ME, McCabe R. Pedicle screw Pullout strength. Correlation with insertional torque. Spine 1993;18:1673-6 DOI ScienceOn |
7 | Carano A, Lonardo P, Velo S, Incorvati C. Mechanical properties of three different commercially available miniscrews for skeletal anchorage. Prog Orthod 2005;6:82-97 |
8 | Kim JW, Ahn SJ, Chang YI. Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2005;128:190-4 DOI ScienceOn |
9 | Burstone CJ, Manhartsberger C. Precision lingual arches. Passive applications. J Clin Orthod 1988:22:444-51 |
10 | Palmer RM, Palmer PJ, Smith BJ, A 5-year prospective study of Astra single tooth implants. Clin Oral Implants Res 2000;11:179-82 DOI |
11 | O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 2004;15:474-80 DOI ScienceOn |
12 | Kim SJ, Lee YJ, Chung KR. An effect of immediate orthodontic force on palatal endosseous appliance (C-Palatal ) in beagle dog. Korean J Orthod 2003;33:91-102 |
13 | Lim JW, Kim WS, Kim IK, Son CY, Byun HI. Three dimensional finite element method for stress distribution on the length and diameter of orthodontic miniscrew and cortical bone thickness. Korean J Orthod 2003;33:11-20 |
14 | Hansson S, Werke M. The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. J Biomech 2003;36:1247-58 DOI ScienceOn |
15 | Wehrbein H, Feifel H, Diedrich P. Palatal implant anchorage reinforcement of posterior teeth: A prospective study. Am J Orthod Dentofacial Orthop 1999:116:678-86 DOI ScienceOn |
16 | Kyung SH, Lim JK, Park YC. The use of miniscrew as an anchorage for the orthodontic tooth movement. Korean J Orthod 2001:31:415-24 과학기술학회마을 |
17 | Martinez H, Davarpanah M, Missika P, Celletti R, Lazzara R. Optimal implant stabilization in low density bone. Clinical Oral Implant Research 2001;12:423-32 DOI ScienceOn |
18 | Ozawa T, Takahashi K, Yamagata M, Ohtori S, Aoki Y, Saito T, et al. Insertional torque of the lumbar pedicle screw during surgery. J Orthop Sci 2005;10:133-6 DOI |
19 | Sennerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface-modified zirconia implants: A histomorphometric and removal torque study in the rabbit. Clin Implant Dent Relat Res 2005;7 Suppl 1:S13-20 DOI |
20 | Umemori M, Sugawara J, Mitani H, Nagasaka H, Kawamura H. Skeletal anchorage system for open-bite correction. Am J Orthod Dentofacial Orthop 1999:115:166-74 DOI ScienceOn |
21 | Ueda M, Matsuki M, Jacobsson M, Tjellstrom A. Relationship between insertion torque and removal torque analyzed in fresh in temporal bone. Int J Oral Maxillofac Implants 1991;6:442-7 |
22 | Block MS, Hoffman DR. A new device for absolute anchorage for orthodontics. Am J Orthod Dentofacial Orthop 1995;107:251-8 DOI ScienceOn |
23 | Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 1997:31:763-7 |
24 | Albrektsson T. Direct bone anchorage of dental implants. J Prosthet Dent 1983;50:255-61 DOI ScienceOn |
25 | Kim CN, Sung JH, Kyung HM. Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage. Korean J Orthod 2003;33:339-50 |
26 | Steinemann S. The properties of titanium. In: Schoeder A, Sutter F, Buser D, Krekeler G editors. 2nd Edition, Oral Implantology. New York: Thieme Medical Publishers, Inc.; 1996. p. 38 |
27 | Huiskes R, Nunamaker D. Local stresses and bone adaptation around orthopedic implants. Calcif Tissue Int 1984;36 Suppl 1:S110-7 DOI |
28 | Kuhlberg AJ, Burstone CJ, T-loop position and anchorage control. Am J Orthod Dentofacial Orthop 1997:112:12-8 DOI ScienceOn |