• Title/Summary/Keyword: 최대수평주응력

Search Result 43, Processing Time 0.025 seconds

Development of Hydro-Mechanical Coupling Method for CO2 Sequestration and Its Application to Sleipner Project (이산화탄소 지중저장을 위한 수리-역학 연동 해석 기술 개발 및 적용 - 슬라이프너 프로젝트)

  • Kwon, Sangki;Lee, Hyeji
    • Tunnel and Underground Space
    • /
    • v.27 no.3
    • /
    • pp.146-160
    • /
    • 2017
  • $CO_2$ sequestration for alleviating global warming is a hot issue in the world. In this study, TOUGH2 and FLAC3D were combined for analyzing the hyro-mechanical coupling behaviors expected in $CO_2$ sequestration and applied it to Sleipner project carried out in Norway. In the analysis, the influence of pore pressure on in situ stress was considered and the influence of caprock permeability on hydro-mechanical behaviors was analyzed. In the condition of constant injection rate, pressure and saturation at the injection well, liquid and gas saturation in rock, major and minor stress variations with time and distance from the injection well, and horizontal and vertical displacements after injection could be investigated. The major principal stress was quickly increased in the early stage and then slowly decreased to a stable value, which was higher than the initial value. In contrast, the minor principal stress returned to initial value after some increase in the early stage. Surface upheaval was steadily increased and it was up to 15mm in 2 years after injection. When the caprock's permeability was changed from $3e-15m^2{\sim}3e-18m^2$, it was found that the injection well pressure and surface upheaval were inversely propotional to the permeability.

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

Paleostress Measurements from Calcite Twin in the Jeongseon Limestone of the Joseon Supergroup (조선 누층군 정선 석회암내의 방해석 쌍정에 나타난 고응력장 연구)

  • 장보안;강성승
    • The Journal of Engineering Geology
    • /
    • v.8 no.1
    • /
    • pp.75-86
    • /
    • 1998
  • Eighteen oriented samples from the Jeongsun limestone of the Joseon Supergroup are collected. The orientations of C-axis of calcite and e twin plane, the average thickness, numbers of twins and the widths of calcite grains in 10 samples are measured. Then, the twin strain, mean width, intensity of twin and relative magnitude and orientations of principal stresses are calculated using Calcite Strain Gauge program. Twin strain, mean width and intensitv rainge between 0.801%~10.927%, $0.43{\mu\textrm{m}}~2.03{\mu\textrm{m}}$, and 33.5~113.4twim/mm, respectively. Metamorphic temperatures calculated from twin show below $70^{\circ}C$, indicating that twins were developed within 2.3km depth. In five samples, two events with different orientations of principal stress produced calcite twins, while only one event produced calcite twins in five samples. The direction of the maximum stress is almost horizontal and the minimum is almost vertical, indicating that the stress regirne is identical with thrust fault. E-W and NW-SE are the most dominant directions of comressive stress and N-S and NE-SW directions are also shown. Comparision between paleostress orientations measured in the study and others indicates that the maximum horizontal stress oriented to E-W may represent the paleostress of period either from the Silurian to the Triassic or from the Silulian to the Permian. Paleostress oriented to NW-SE may be the major direction of stress during the Daeho orogeny.

  • PDF

Microcrack Orientations in Bulgugsa Granites from Southwestern Gyeongsang Basin (경상분지 남서부 일대의 불국사 화강암류에서 발달하는 미세균열의 방향성)

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.206-221
    • /
    • 2008
  • We have studied general orientational characteristics of microcracks distributed in Bulgugsa Granites of southwestern Gyeongsang Basin. Microcracks of 131 sets, which were developed on horizontal surfaces of II rock samples collected from Sacheon-Gosung, Geoje-si and Namhae-gun areas, were distinguished by image processing. Then, 45 sets with a distinct linear array on image were sorted out. These microcracks can be comparable with vertical grain planes. Orientations of these microcracks were compared with those of vertical rift and grain planes developed in Cretaceous and Jurassic granites of Korea. In the distribution chart, the agreement of the distribution pattern between microcracks of 45 sets and above vertical planes suggests that microcrack systems developed all over the study area also occur regionally in Cretaceous and Jurassic granites of Korea. Whole domain of the directional angle-frequency chart can be divided into 20 domains in terms of the phases of the distribution of microcracks. Meanwhile, 18 domains from 45 sets of microcracks were compared with the maximum principal stress orientations suggested from previous studies. The majority of maximum principal stress orientations pertain to domain $1{\sim}2$, $5{\sim}6$, $11{\sim}15$, $17{\sim}18$ and $19{\sim}20$, and these domains are coincident with the orientation of the 1st and 2nd-frequency orders represented in a rose diagram for 45 sets of microcracks. Representative orientations of open microcrack reflect the maximum principal stress orientations suggested in previous studies.

Research of Stresses Distribution and Loading Weight on Concrete Electric Pole Considering Field Condition (설치조건을 고려한 배전용 콘크리트전주의 응력분포 및 하중에 관한 연구)

  • Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.183-188
    • /
    • 2004
  • A method of double-pole construction is developing to strengthen the mechanical intensity of the electric poles. Therefore the mechanical properties of the double-pole were researched in this paper. First, considering field special quality electric poles were established. In the next tensile force was applied and stress distribution and fatigue load were examined. When a base of the pole is concrete, mechanical intensity of the double-pole increased about 1.7 times compared a single pole. In the case of general soil base, the concrete base should be needed to expect the reinforcement effect of the double-pole.

Stability Analysis of Multiple Thermal Energy Storage Caverns Using a Coupled Thermal-Mechanical Model (열-역학적 연계해석 모델을 이용한 다중 열저장공동 안정성 분석)

  • Kim, Hyunwoo;Park, Dohyun;Park, Eui-Seob;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.24 no.4
    • /
    • pp.297-307
    • /
    • 2014
  • Cavern Thermal Energy Storage system stores thermal energy in caverns to recover industrial waste heat or avoid the sporadic characteristics of renewable-energy resources, and its advantages include high injection-and-extraction powers and the flexibility in selecting a storage medium. In the present study, the structural stability of rock mass pillar between these silo-type storage caverns was assessed using a coupled thermal-mechanical model in $FLAC^{3D}$. The results of numerical simulations showed that thermal stresses due to long-term storage depended on pillar width and had significant effect on the pillar stability. A sensitivity analysis of main factors indicated that the influence on the pillar stability increased in the order cavern depth < pillar width < in situ condition. It was suggested that two identical caverns should be separated by at least one diameter of the cavern and small-diameter shaft neighboring the cavern should be separated by more than half of the cavern diameter. Meanwhile, when the line of centers of two caverns was parallel to the direction of maximum horizontal principal stress, the shielding effect of the caverns could minimize an adverse effect caused by a large horizontal stress.

Effects of occlusal load on the cervical stress distribution: A three-dimensional finite element study (교합하중이 치경부 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Lee, Hyeong-Mo;Hur, Bock;Kim, Hyeon-Cheol;Woo, Sung-Gwan;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.427-436
    • /
    • 2006
  • The objective of this study was to investigate the effects of various occlusal loads on the stress distribution of the buccal cervical region of a normal maxillary second premolar, using a three dimensional fnite element analysis (3D FEA). After 3D FE modeling of maxillary second premolar, a static load of 500N of three load cases was applied. Stress analysis was performed using ANSYS (Swanson Analysis Systems, Inc., Houston, USA). The maximum principal stresses and minimum principal stresses were sampled at thirteen nodal points in the buccal cervical enamel for each four horizontal planes, 1.0 mm above CEJ, 0.5 mm above CEJ, CEJ, 0.5 mm under CEJ. The results were as follows 1. The peak stress was seen at the cervical enamel surface of the mesiobuccal line angle area, asymmetrically. 2. The values of compressive stresses were within the range of the failure stress of enamel. But the values of tensile stresses exceeded the range of the failure stress of enamel. 3. The tensile stresses from the perpendicular load at the buccal incline of palatal cusp may be shown to be the primary etiological factors of the NCCLs.

Finite Element Analysis of Bone Stress Caused by Horizontal Misfit of Implant Supported Three-Unit Fixed Prosthodontics (3차원 유한요소법에 의한 임플란트 지지 3본 고정성 가공 의치의 부적합도가 인접골 응력에 미치는 영향 분석)

  • Lee, Seung-Hwan;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.147-161
    • /
    • 2012
  • This study is to assess the effect of horizontal misfit of an implant supported 3-unit fixed prosthodontics on the stress development at the marginal cortical bone surrounding implant neck. Two finite element models consisting of a three unit fixed prosthodontics and an implant/bone complex were constructed on a three dimensional basis. The three unit fixed prosthodontics were designed either shorter (d=17.8mm model) or longer (d=18.0mm model) by 0.1mm than the span of two implants placed at the mandibular second premolar and second molar areas 17.9mm apart. Fitting of the fixed prosthodontics onto the implant abutments was simulated by a total of 6 steps, that is to say, 0.1mm displacement per each step, using DEFORM 3D (ver 6.1, SFTC, Columbus, OH, USA) program. Stresses in the fixed prosthodontics and implants were evaluated using von-Mises stress, maximum compressive stress, and radial stress as necessary. The d=17.8mm model assembled successfully on to the implant abutments while d=18.0mm model did not. Regardless if the fixed prosthodontics fitted onto the abutments or not, excessively higher stresses developed during the course of assembly trial and thereafter. On the marginal cortical bone around implants during the assembly, the peak tensile and compressive stresses were as high as 186.9MPa and 114.1MPa, respectively, even after the final sitting of the fixed prosthodontics (for d=17.8mm model). For this case, the area of marginal bone subject to compressive stresses above 55MPa, equivalent of the $4,000{\mu}{\varepsilon}$, i.e. the reported threshold strain to inhibit physiological remodeling of human cortical bone, extended up to 2mm away from implant during the assembly. Horizontal misfit of 0.1mm can produce excessively high stresses on the marginal cortical bone not only during the fixed prosthodontics assembly but also thereafter.

A Study on the Development of Force Limiting Devices of Folded Plate Type (절판형 응력제한 기구의 개발에 관한 연구)

  • Kim, Cheol Hwan;Chae, Won Tak
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.571-579
    • /
    • 2014
  • The steel braces are used to control the lateral drift of high rise buildings. The braces are designed as tensile members since the braces consisted of slender member can not resist compressive loads by elastic buckling. To resolve this problem, a lot of research were performed to develop the non-buckling member. The force limiting device (FLD.) is one of them. The purpose of this study is the development of FLD. to prevent a elastic buckling for a slender member. The folded plate type is proposed to induce the yielding before occurring elastic buckling. In this study, member test and FEM analysis for proposed type were performed. Further, It is verified that the structure with FLD member is stable by high energy absorption. The proposed folded plate type FLD could be effective to preserve the compressive member from the elastic buckling.

Various Measurement Methods for Fold-axis from Fold-related Structural Elements: An Example from Danyang, Chungcheongbuk-do (습곡관련 구조요소들을 이용한 다양한 습곡축 측정방법의 실제적 적용성과 문제점: 충북 단양지역에서의 예)

  • Choi, Ho-Seok;Kim, Young-Seog
    • Journal of the Korean earth science society
    • /
    • v.42 no.2
    • /
    • pp.175-184
    • /
    • 2021
  • Fold axis of fold, a representative ductile deformation structure, is important for collecting information on the 3D fold structure and the orientation of maximum horizontal principal stress at the time of deformation. For this reason, several fold axis measurement methods based on the fold-related structural elements have been suggested and used even in areas where it is impossible to measure it directly. Thus, these various measurement methods are briefly introduced here, and the measured data with different methods are compared to estimate these methods' reliability. For this purpose, we acquired fold axes at six sites across the Manhang formation of the Pyeongan supergroup and limestones of the Joseon supergroup in Danyang, Chungcheongbuk-do, where fold structures are well developed. The data from the different methods are generally consistent, indicating practical applicability. Most of the fold axes from the measured sites show NNNE or NE trends indicating WNW-ESE or NW-SE trending maximum horizontal principal stress, except for the one site with a WNW trend. The WNW-ESE trending fold axis might be related to a different orogeny or secondary folding. The minor difference in the trends between N-NNE and NE was interpreted as being due to different scale; however, further research is needed to confirm this.