• 제목/요약/키워드: 초음파 조영제

Search Result 43, Processing Time 0.033 seconds

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

Contrast-enhanced US of the liver mass : Quantitative Analysis (초음파 조영제를 이용한 간종양의 유형별 소견 고찰)

  • Kim Yun-Min;Han Jung-Hwan;Kim Dong-Hwan;Park Won-Sik
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.148-156
    • /
    • 2001
  • Ⅰ. Purpose : To determine echo value and duration of contrast enhancement of liver mass on contrast-enhanced US with Levovist by quantitative analysis. Ⅱ. Materials and Methods : Twenty three patients with liver mass were prospectively evaluated with cont

  • PDF

The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis (전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구)

  • Hwang, Sung Il;Lee, Hak Jong;Kim, Kil Joong;Chung, Jin-haeng;Jung, Hyun Sook;Jeon, Jong June
    • Ultrasonography
    • /
    • v.32 no.2
    • /
    • pp.132-142
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the correlations of various kinetic parameters derived from the time intensity curve in a xenograft mouse model injected with a prostate cancer model (PC-3 and LNCaP) using an ultrasound contrast agent with histopathologic parameters. Materials and Methods: Twenty nude mice were injected with human prostate cancer cells (15 PC-3 and five LNCaP) on their hind limbs. A bolus of $500{\mu}L$ ($1{\times}10^8$ microbubbles) of second-generation US contrast agent (SonoVue) was injected into the retroorbital vein. The region of interest was drawn over the entire tumor. The time intensity curve was acquired and then fitted to a gamma variate function. The maximal intensity (A), time to peak (Tp), maximal wash-in rate (washin), washout rate (washout), area under the curve up to 50 sec ($AUC_{50}$), area under the ascending slope ($AUC_{in}$), and area under the descending slope ($AUC_{out}$) were derived from the parameters of the gamma variate fit. Immunohistochemical staining for VEGF and CD31 was performed. Tumor volume, the area percentage of VEGF stained in a field, and the count of CD31 (microvessel density, MVD) positive vessels showed correlation with the parameters from the time intensity curve. Results: No significant differences were observed between the kinetic and histopathological parameters from each group. MVD showed positive correlation with A (r=0.625, p=0.003), washin (r=0.462, p=0.040), $AUC_{50}$ (r=0.604, p=0.005), and $AUC_{out}$ (r=0.587, p=0.007). Positive correlations were also observed between tumor volume and $AUC_{50}$ (r=0.481, p=0.032), washin (r=0.662, p=0.001), and $AUC_{out}$ (r=0.547, p=0.012). Washout showed negative correlations with MVD (r=-0.454, p=0.044) and tumor volume (r=-0.464, p=0.039). The area percentage of VEGF did not show any correlation with calculated data from the curve. Conclusion: MVD showed correlations with several of the kinetic parameters. CEUS has the potential for prediction of tumor vascularity in a prostate cancer animal model.

Usefulness of Superparamagnetic Iron Oxide (SPIO) as a Negative Oral Contrast Agent in MR Cholangiopancreatography (자기공명 담관췌장초영술에서 음성 경구 조영제로 사용한 초상자성 산화철 제재의 유용성)

  • 이정민;송원규;이종덕
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.49-56
    • /
    • 2001
  • Purpose : To evaluate value of superparamagnetic iron oxide (SPIO) as a negative oral contrast agent in MR cholangiopancreatography (MRCP). Materials and methods : Forty-eight patients with suspected biliary tract or pancreatic diseases and six healthy volunteers were enrolled in this study. All MR images were obtained using a 1.5 T MR unit. MR-CP using fat-suppressed half-Fourier acquisition single-shot turbo spin echo (HASTE) and turbo spin echo (TSE) techniques were performed and reconstructed with maximal intensity projection (MIP). To determine the most optimal concentration of SPIO to obliterate the high signal intensity of water, a phantom experiment was conducted with various concentrations of SPIO-water mixture. Two radiologists evaluated pre- and postcontrast MRCPS. The contrast enhancement was assessed on the basis of loss of signal intensity in the stomach and duodenum. Results : In the phantom experiment, a significant increase of percentage of signal intensity loss (PSIL) occurred in concentration of 22.4 ugFe/ml (Feridex1 ml diluted with water 500 ml). Postcontrast MRCP showed an improved image quality compared with precontrast images. The rate of improvement in the diagnosis of diseases of the common bile duct and pancreatic duct was 25% (12/48). Conclusion : In patients with suspected biliary tract and pancreatic diseases, the SPIO is useful as a negative oral contrast agent for MRCP and provides an improvement of image quality.

  • PDF

CT Findings of Desmoid Tumor arising at Abdominal Wall: Two Cases Report (복벽에 발생한 데스모이드 종양의 급속 조영 CT 소견 : 2례 보고)

  • Cho, Dae-Hyoun;Cho, Jae-Ho;Chang, Jae-Chun
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.386-392
    • /
    • 1995
  • Desmoid tumor is a type of fibromatosis usually arise in deep musculo-aponeurotic structures, primarily of the trunk and extremities. It is characterized by proliferation of fibroblastic tissue and does not metastasize but may be locally aggressive. Eventhough the surgical margin reveals clean, recurrence often occurs. To analyze the extent of the tumor and homodynamic characteristics exactly, we performed IV bolus CT. Desmoid tumors show peripheral rim enhancement on early phase scan and more strong, central enhancement on late phase IV bolus CT, which reflects abundant fibroblastic components of the tumor. We report two cases of pathologically confirmed desmoid tumor performed IV bolus CT.

  • PDF

Examination Techniques and Imaging Findings of Hepatic Hemangioma (간혈관종의 검사기법과 영상소견)

  • Chang-Hoe Koo;Jong-Wan Keum;Ji-Eun Seok;Dong-Chul Choi;Yun-Ho Choi;Man-Seok Han;Min-Cheol Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.375-384
    • /
    • 2023
  • Most Hepatic hemangiomas are asymptomatic and small in size, making them difficult to find by pathological examination. Therefore, radiological diagnosis is essential for the early finding and diagnosis of Hepatic hemangioma. Three-phase method using contrast medium in computed tomography, T1, T2-weighted imaging in magnetic resonance imaging, dynamic magnetic resonance imaging using contrast medium, echo planar imaging method, diffusion-weighted imaging method, blood pool scan using 99mTc-labeled red blood cells in nuclear medicine, we looked at the color doppler method In ultrasound, and it is important to accurately understand the imaging findings of hepatic hemangioma and perform the examination in order to make an accurate diagnosis. most hepatic hemangioma are benign tumors, care should be taken not to confuse them with malignant tumors such as hepatocellular carcinoma to prevent unnecessary procedures. Therefore, in order to make an accurate diagnosis, it is important to accurately understand the imaging findings of hemangioma and perform the examination.

An Experimental Comparative Study of Radiography, Ultrasonography and CT Imaging in the IV Catheter Fragment (정맥내 카테터 조각의 엑스선, 초음파 및 CT 영상의 실험적 비교 연구)

  • Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.185-191
    • /
    • 2016
  • The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon$^{(R)}$ IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose ($0.2139mSv{\cdot}Gy^{-1}{\cdot}cm^{-2}$) form DAP DAP ($0.93{\mu}Gy{\cdot}m^2 $), and dose length product (DLP) ($201mGy{\cdot}cm$) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.

Basic study on proliferation control of cancer cells using combined ultrasound and LED therapeutic module (초음파와 LED를 이용한 일체형암세포 증식억제 모듈의 기초연구)

  • Cho, Kyung-rae;Choe, Se-woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1107-1113
    • /
    • 2018
  • Ultrasonography and photodynamic therapy have been proposed as useful tools as a treatment for inducing necrosis of cells using reactive oxygen species. Apoptosis is an internal mechanism necessary for cells regardless of damage. Ultrasound has the effect of inducing the apoptosis of these cells, and the frequency of 1 MHz is the most applicable area for medical use. The laser which is generally used in photodynamic therapy has a heat reaction and the treatment is limited. However, as a small light emitting diode is developed, it shows possibility to minimize the equipment and reduce heat reaction. On the other hand, there are relatively few researches on direct effects of light compared with studies using photosensitizers, and the area is also limited. Therefore, in this paper, we have developed a cancer cell proliferation control module using ultrasonic and light emitting diodes, which have relatively few side effects, and quantitatively analyze the effect of the module to propose an optimal suppression technique.

Echo-PIV: in vivo Flow Measurement Technique (에코 PIV: in vivo 유동 측정기법)

  • kim Hyoung-Bum;Hertzberg Jean;Shandas Robin
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.26-35
    • /
    • 2005
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) method has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window of offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow and pulsatile flow showed good agreement with both optical PIV measurements and the known analytic solution. These studies indicate that echo PIV is a promising technique for the non-invasive measurement of velocity profiles and shear stress.

  • PDF

Ultrasound Contrast Agent (초음파 조영제)

  • Kim, Gi-Wook
    • Clinical Pain
    • /
    • v.20 no.2
    • /
    • pp.86-92
    • /
    • 2021
  • Ultrasound imaging in clinical practice is one of the widely used diagnostic methods because there is no radiation risk, more cost- effective compared to MRI or CT, and possible to perform an intervention through fast real-time imaging. In order to increase the diagnostic value, the studies of contrast-enhanced ultrasound (CEUS) using an ultrasound contrast agent have been actively conducted since about 50 years ago and are being used clinically in vascularity and microcirculation of internal organs. Although ultrasound is actively used for the diagnosis and treatment of various diseases in musculoskeletal disorders, there are some limitations in diagnosing mild or small lesions, inflammatory reactions, or abnormalities at the molecular level. In this review, the principles, types, and research, and clinical applications of ultrasound contrast agents have been summarized and introduced. If we understand the characteristics of the ultrasound contrast agents and anatomical knowledge, as well as molecular changes, the ultrasound contrast agents are widely applied in musculoskeletal disorders and have tremendous potential for diagnosis and treatment.