• Title/Summary/Keyword: 초고층 구조

Search Result 418, Processing Time 0.026 seconds

Experimental study of structural behavior of 80MPa concrete outrigger member using post tension method (PT공법을 적용한 80MPa급 콘크리트 아웃리거부재의 실험적 연구)

  • Choi, Jong-Moon;Kim, Woo-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.31-34
    • /
    • 2009
  • Large outrigger elements tie the concrete core to perimeter columns, significantly increasing the building's lateral stiffness as well as its resistance to overturning due to wind. The outriggers are deep elements, and large tie forces are resisted by top and bottom heavy longitudinal reinforcing and vertical ties. To reduce construction costs, all primary reinforcing bars in outrigger levels are SD500. Further, concrete strengths of 80MPa have been specified for outrigger elements. However, the reductions in the amount of concrete and reinforcement steel are more increased in tall building. With these backgrounds, 80MPa high strength concrete outrigger system using post tension method is developed. Significant economic savings can be made by reducing the element sizes and material content. The developed outrigger system is designed using strut-and-tie models. In addition, four 1/4-scale test specimens were selected from the same prototype structure. The results from the tests are confirmed that the structural behaviors of the developed outrigger member have better capacities than those of a conventional method.

  • PDF

A Development and Characterization of Refractory Panel (내화패널의 개발과 특성에 관한 연구)

  • Kim, Dong-Joon;Kwon, Young-Jin;Kim, Yong-Ro;Han, Byung-Chan;Kim, Jae-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.61-66
    • /
    • 2009
  • 최근 초고층 건축물 등에 적용되는 고강도콘크리트의 내화성능에 대한 문제점이 제기됨에 따라 국토해양부에서는 고강도콘크리트 내화성능 관리 기준을 고시한 바 있으며, 건설업계에서도 이에 대응하기 위해 다양한 기술 검토가 이루어지고 있다. 본 연구에서는 고강도콘크리트의 취약점으로 제기되고 있는 화재시의 폭렬문제에 대한 대응방안으로서 기존 연구를 통해 내화성능이 우수한 것으로 보고되고 있는 ECC 를 영구거푸집으로 활용한 고강도콘크리트의 내화성능을 검토하였다. ECC 영구거푸집을 활용한 고강도콘크리트 기둥부재의 내화성능 검토 결과, 영구거푸집과 고강도콘크리트 계면으로의 열 침투를 제어할 수 있도록 부재 생산 및 구축 방안을 검토하고, ECC의 적정 배합 및 두께를 확보한다면 고강도콘크리트의 내화성능 확보기술로서의 활용이 가능할 것으로 판단된다. 또한, 내화성 영구거푸집으로서의 단순 활용 방안 이외에 ECC의 우수한 물리적 성능을 활용하여 구조성능을 분담할 수 있는 방안으로의 지속적 검토가 필요할 것으로 판단된다.

  • PDF

A Study on the Development of a Dry P0SCO E&C Fire Board Method with High Fire Resistance (건식화 P0SCO E&C Fire Board 공법 개발에 관한 연구)

  • Kim, Woo-Jae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.721-724
    • /
    • 2008
  • The present study was to develop a dry PFB method similar to the existing gypsum board construction method in order to apply the existing wet PFB method that uses fire.resistant adhesive. It was found that the existing wet method can produce concrete compressive strength of 80MPa and fire resistance of 3 hours with 30mm PF boards. The goal of development in this study was fire resistance of 3 hours through dry construction of 15mm fire resistant boards. The results of fire resistance test showed an increase in thermal durability and thermal strain. It is believed that inorganic fiber reduces thermal strain, and lowers heat insulation performance by 15% or less. This suggests that heat insulation performance was improved by the change in the inner composition of PF board resulting from the adjustment of Al:Si mol ratio, high temperature molding, and dry curing. According to the results of fire resistance test, when the dry PF method was applied, the temperature of the main reinforcing bar was 116$^\circ$C in 15mm, 103.8$^\circ$C in 20mm, and 94$^\circ$C in 25mm, and these results satisfied the current standards for fire resistance control presented by the Ministry of Land, Transport and Maritime Affairs. When a 3 hour fire resistance test was performed and the external properties of the specimen were examined, the outermost gypsum board hardly remained and internal PF board maintained its form without thermal strain.

  • PDF

Fire-fighting Pump Approval Standard for Fire-fighting Trucks with an Additional Positive Displacement Pump (용적형 펌프를 추가한 소방자동차용 소방펌프의 성능 인정기준에 관한 연구)

  • Han, Yong-Taek;Sung, Ki-Chan;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.104-110
    • /
    • 2016
  • Positive displacement pumps with high pressure and water capacity are used large fires in various high-rise buildings. This study provides information for a performance approval standard of fire pumps for fire trucks based on centrifugal pump standards enacted in 2012. An experiment was conducted with a positive displacement pump for three levels of performance from the approval standard (V-1, 2, and 3). The efficiency of the pump was included in the reference, which requires the approval of 65% performance, the same as a centrifugal pump. The water pressure is between 1.5 and 2.5 MPa, and the required flow rate was established as at least $0.31m^3/min$ and up to $3.0m^3/min$. A relief valve was added to adjust the shut-off pressure due to the structural characteristics of the positive displacement pump. A strainer was also installed to prevent damage to the inside of the pump due to foreign matter. However, the strainer includes a difference from the positive displacement pump to operate without a vacuum pump and the centrifugal pump. This is due to the additional approval standard portion of the positive displacement pump, which is expected to be selected for more variety of fire-fighting equipment and proactive responses to fire suppression in a high-rise buildings and large fires. In conclusion, this approval standard was enacted in January 2016.

Development of MEMS Inclinometer Sensor System (MEMS형 경사계 센서의 유효성 평가)

  • Ha, Dae Woong;Kim, Jong Moon;Park, Hyo Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.271-274
    • /
    • 2013
  • Inclinometer sensors are widely applied in many fields. Especially in the field of construction of high-rise buildings also measure the horizontal and vertical help has been applied to monitor. Recent micro electro-mechanical system(MEMS) technology with the development of the many sensors have been developed. In this paper, a MEMS inclinometer is based on a MEMS accelerometer. The sensor can measure the angle of inclination using the relationship between static acceleration and gravity acceleration from an accelerometer. From this principle, inclinometer has been developed that has more accurate. The accuracy is proved by the experiment with laser displacement. Results in the experiment express high-accuracy, stability and economics of MEMS inclinometer. In conclusion, wireless MEMS inclinometer sensor is expected to be applicable in the areas of construction and many other industries with accurate and convenient monitoring system.

An Experimental Evaluation on Flexural Performance of Light-Weight Void Composite Floor using GFRP (GFRP를 이용한 경량합성바닥의 휨성능에 대한 실험적 평가)

  • Ryu, Jae-Ho;Park, Se-Ho;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.125-135
    • /
    • 2011
  • To obtain a lower story height with a long span and better fire resistance, a new composite floor system using GFRP (glass-fiber-reinforced plastics) was proposed. This floor system consists of asymmetric steel with a web opening, a hollow core ball, concrete, and GFRP. To evaluate the flexural performance of the new composite floor system, an experiment was conducted. The test parameters were the presence of GFRP, the void ratio in relation to the hollow core balls, and the web opening. The test results showed that the resistance and stiffness of the specimen with GFRP were 10% higher than those of the reference specimen, and that fully composite action was accomplished up to the yielding point. After the attainment of the yield strength, the ductility of the specimen was reduced due to the stress concentration around the web openings. The slip between the concrete and steel beam, however, was small. Thus, in the design of the proposed new floor systems, it is desirable that the calculated resistance be reduced by 15%, for safety.

Analysis of Sunshine Amount for Education Environment according to Installation of Apartment Structures (아파트 구조물 설치에 따른 교육환경 일조량 분석)

  • Jang, Ho-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • Due to recent urban maintenance project for the aged towns, the reconstruction of apartments into super-high-rise and high-rise apartment structures has been approved for concentrated use of land, and accordingly the infringement on sunshine for nearby residential area is rising as a social issue. Especially the educational environment conditions according to infringement on sunshine in educational facilities are posing many problems. Accordingly in this study, for such sunshine analysis of educational environment, Auto $CAD^{(R)}$ software has been used to construct the 3D model for the educational facility structures. And with the simulation technique, the windows and the schoolyard of the education facility were set to be the lighting standard surface to take measurements for the sunshine environment of the educational facilities by the minute from 8:00AM until 4:00PM for the sunshine amount by true solar time according to the movement of the sun. Also, the sunshine environment of the education facility according to the damage before/after new construction of apartments was charted, and through comparison with the video produced by sun shadow projection method, the sunshine amount of the educational environment could be verified. In future, it is expected to be efficiently used in the sunshine analysis of education environment utilizing such simulation techniques.

A Case Study on the Cause and Reinforcement of Railroad Facilities Settlement According to the Ground Excavation (지반굴착에 따른 철도시설물의 침하 원인 및 보강 사례연구)

  • Oh, Beyung-Sam
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.10
    • /
    • pp.85-94
    • /
    • 2012
  • Recent development trend of construction projects in the urban area is the efficient use of insufficient land, however caused to difficult construction conditions because of many adjacent structures. This paper presents the case study that analyzed the ground settlement of railroad structure for the double track railway project of Gyeongui line, adjacent to the high rise building under ground excavating for substructure work, considering interaction of soft ground characteristics. Field survey and measurement works were carried out during construction of station and excavation of high rise building, and field data were analyzed to find the source of settlement of platform and railway. In addition, the soil reinforcement and foundation restoration were performed using in-situ injection method, i.e., D-ROG(Digitalized Restoring On Grout) method which filled the pore of bottom and around of foundation with micro-cement.

Comparison of Super Structure-Sub Structure Separation Analysis and Unification Analysis about Building Structures (건축구조물의 상부구조-하부구조 분리해석과 일체해석의 비교분석)

  • Kim, Jae-Yo;Kim, Jin-Yong;Kang, Su-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.19-28
    • /
    • 2016
  • In the case of structural analysis for building structures, the super-structure and the sub-structure are analyzed by using separate structural models in the field because of time saving, facile result interpretation and easy analysis of dynamic behavior. However this separate structural model violated the compatibility condition of structural analysis and it can not consider the interaction of superand sub- structures. In the present study, the analysis results of this separate model were compared to those of the unified model of super- and sub- structures which can consider the interaction of super- and sub- structures and reflect the realistic boundary conditions. According to the comparison results, the the analysis model using separate models can underestimate the member force and deflection of structural members in the super-structures and overestimate the deflection and member force of sub-structures. Therefore, in the case of high-rise buildings, irregular shaped buildings, buildings which are expected to be affected by large differential settlement and remodeling buildings, the unified structural model for super- and sub- structures was recommended for structural analysis instead of the separate structural model.

Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings (초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.19-33
    • /
    • 2008
  • Dynamic response measurements from natural excitation were carried out for 25- and 42-story buildings to evaluate their inherent properties, such as natural frequencies, mode shapes and damping ratios. Both are reinforced concrete buildings adopting a core wall, or with shear walls as the major lateral force resisting system, but frames are added in the plan or elevation. In particular, shear walls in a 25-story building are converted to frames from the 4th floor level downwards while maintaining a core wall throughout, resulting in a fairly complex structure. Due to this, along with similar stiffness characteristics in the principal directions, significantly coupled and closely spaced modes of motion are expected in this building, making identification rather difficult. By using various state-of-the-art system identification methods, the modal parameters are extracted, and the results are then compared. Three frequency-domain and four time-domain based operational modal identification methods are considered. Overall, all natural frequencies and damping ratios estimated from the different identification methods showed a greater consistency for both buildings, while mode shapes exhibited some degree of discrepancy, varying from method to method. On the other hand, in comparison with analysis results obtained using the initial finite element(FE) models, test results exhibited a significant difference of about doubled frequencies, at least for the three lower modes in both buildings. To improve the correlation between test and analysis, a few manual schemes of FE model updating based on plausible reasons have been applied, and acceptable results are obtained. The advantages and disadvantages of each identification method used are addressed, and some difficulties that might arise from the updating of FE models, including automatic procedures, for such large structures are carefully discussed.