• Title/Summary/Keyword: 체적오차

Search Result 183, Processing Time 0.038 seconds

A Study on Application of Transverse Flux Linear Motor to Indexer System (인덱서 시스템에 대한 횡축형 선형 전동기의 적용에 관한 연구)

  • Kim J.W.;Ahn J.B.;Kang D.H.;Jang J.H.;Kim J.M.;Bang D.J.;Jeon J.Y.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.553-559
    • /
    • 2004
  • The servo motor is used for the driving power source of the conventional linear conveyor system. The mechanical power transfer system is needed for converting the circular to the linear operation. But this system causes some problems of position error, the necessity of the periodical maintenance. In this paper the study on application of transverse flux linear motor(TFLM) is carried out for the indexer system of LCD processing because TFLM has much thrust per a volume than the conventional motor. TFLM is suitable system for the indexer system because of capacity of acceleration, maximum speed and precision of the position, etc.

A Numerical Validation for Incompressible Two-phase Flow using CLSVOF and Artificial Compressibility Methods (CLSVOF과 가상압축성 기법을 이용한 비압축성 2상 유동 수치해석 검증 연구)

  • Yoo, Young-Lin;Choi, Jeong-Yeol;Sung, Hong-Gye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.5
    • /
    • pp.71-79
    • /
    • 2017
  • A numerical analysis of the liquid-gas two-phase flows has been conducted. The incompressible equations of the two-phase flows were solved by the artificial compressibility method with the CLSVOF interface capturing method. To analyze the grid dependency of CLSVOF, a numerical analysis of Zalesak's disk and three-dimensional liquid deformation problem were carried out, and the reconstruction of deformation was investigated. The Rayleigh-Taylor instability was numerically analyzed by applying the equations of incompressible two-phase flow, and the surface instability was observed.

Robust Control of the Nonlinear Hydraulic Servo System Using a PID Control Technique (PID 제어 기술을 이용한 비선형 유압 시스템의 강인 제어)

  • Yu, Sam-Hyeon;Lee, Jong-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.5
    • /
    • pp.850-856
    • /
    • 2001
  • Even though the hydraulic servo system has been widely used in industrial and military equipments since it has a lot of advantages, it is not easy to design controller due to the high nonlinearities and the parametric uncertainties. The dynamic behavior of the real process in the hydraulic servo system differs from that described by its model because the model is linearized. Another reason of the difference is caused by the variety of parameters, since the system parameters of the dynamic equation are affected by the operating conditions such as temperature and pressure. In this study, the designing process of the MRNC with a PID compensator is introduced and applied to the load sensing hydraulic servo system. The results show that the designed controller guarantees the robust control performance despite of both the nonlinearities and the parametric uncertainties.

Development of Program for Predicting GBD to Improve Canning Process Capability for Catalytic Converter (촉매변환기의 캐닝 공정능력 향상을 위한 GBD 예측 프로그램의 개발)

  • Lee, Young Dae;Chu, Seok Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.419-427
    • /
    • 2013
  • The catalytic converters for automobile exhaust systems are manufactured by inserting a mat-wrapped substrate into a stainless steel can. A residual pressure that is too high will initiate a fracture in the substrate. In contrast, a residual pressure that is too low will fail to hold the substrate in the acceleration or deceleration phase. Both the process capability and mat pressure on the substrate are predicted while considering the effect of the statistical variation in the dimensions of the parts. The validity of the solutions is then confirmed. A program using EXCEL combines a finite element analysis and process capability analysis in one program.

Sensitivity of Parameters for Elasto-plastic Constitutive Model (탄.소성 구성 모델의 초질매개변수 예민성)

  • Jeong, Jin-Seop;Kim, Chan-Gi;Lee, Mun-Su
    • Geotechnical Engineering
    • /
    • v.8 no.2
    • /
    • pp.81-96
    • /
    • 1992
  • This paper dealt with the influence of experimental error generated inevitably during performing experiments on the granular soil behaviour analysis selecting Lade's Single Work-Hardening constitutive model. Several isotropic compression-expansion tests and a series of drained conventional triaxial tests with various confining pressures for Baekma river sands were performed and the values of parameters for the above model were determined using computer program developed for this study based on regression analysis. By finding the range of the upper and lower bound for deviator stress and volumetric strain versus axial strain dependant on the increase and decrease of the standard deviation from mean value of parameters, sensitivities of all the parameters were examined. Practical use of program to determine the parameters and capability to predict the behaviour of granular soil by Lade's Single Work -Hardening model verified.

  • PDF

Study of Aluminum Agglomeration Model During Solid Propellant Combustion (고체추진제 연소 중 알루미늄 응집 모델 연구)

  • Yoon, Jisang;Lee, Kookjin;Kim, Daeyu;Park, Namho;Ko, Seungwon;Yoon, Woongsup
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.78-86
    • /
    • 2019
  • Aluminum, which is a metal fuel contained in the composite solid propellant, is not ignited and burned on the combustion surface by the oxide film, and it partially melts and coalesces with surrounding aluminum particles. For the evaluation and design of the propellant performance, modeling was performed to predict the size and distribution of agglomerated particles, and the size and distribution of agglomerates were compared and verified through experiment. The predicted values showed the tendency to decrease with pressure as in the experiment, but the error increased as the pressure increased. The agglomerated particle distribution graph showed a difference in the volume fraction although the diameter at the peak was the same.

Development of 2DH hydrodynamic and scalar transport model based on hybrid finite volume/finite difference method (하이브리드 FVM/FDM 기반의 2차원 흐름 및 스칼라 이송 모형 개발)

  • Hwang, Sooncheol;Son, Sangyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.105-105
    • /
    • 2021
  • 본 연구에서는 2차원 비선형 천수모형과 수심평균된 스칼라 이송모형을 해석하는 수치모형에 대해 기술하였다. 수치모형의 정확성을 보장함과 동시에 안정성을 높이기 위해 유한체적법, 플럭스 재구성 및 minmod 제한자를 사용하였다. 비선형 천수방정식의 이송항과 바닥 경사항은 계산된 수심의 양수 보존과 흐름의 정상 상태를 보장하기 위한 second order well-balanced positivity preserving central-upwind method를 이용하여 수치적으로 이산화되었다. 마찬가지로, 이송-확산 방정식 내 이송항은 동일한 2차 풍상차분법을 통해 수치적으로 풀이하였다. 격자점 경계면에서의 불연속으로 인한 수치진동을 방지하기 위해 이송항의 계산에 포함된 보존항의 차이로 인해 발생하는 스칼라의 수치확산을 최소화하기 위해 무차원의 비소산함수를 도입하였다. 또한, 확산항은 유한차분법을 이용하여 이산화하였다. 제안된 수치모형은 시간미분항의 계산을 위해 오일러 기법을 적용하여 계산된 수심 및 스칼라의 양수 보존여부와 함께 정지된 흐름의 정상 상태의 보존여부를 확인하였다. 제안된 수치모형의 해석 정확성을 평가하기 위해 1, 2차원 공간 내 다양한 흐름 조건에서의 해석해를 이용한 3개의 벤치마크 테스트를 수행하였다. 평균 제곱근 오차(Root Mean Squared Error, RMSE)를 산정하여 수치모형의 성능을 정량적으로 평가하였으며, 비소산함수를 적용함에 따라 스칼라의 수치확산이 감소하게 되었음을 확인하였다. 또한, 세 차례의 벤치마크 테스트 결과는 공통적으로 수치모형에 의해 계산된 결과값이 비소산함수를 고려함에 따라 해석해와 잘 일치함을 확인하였다.

  • PDF

Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

A STUDY FOR OCCLUSAL FEATURES OF FIRST PERMANENT MOLAR AND SECOND PRIMARY MOLAR (제 1대구치와 제 2유구치의 교합면 양상에 관한 연구)

  • Jeon, So-Hee;Kim, Jae-Gon;Yang, Yeon-Mi;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.89-100
    • /
    • 2005
  • The purpose of this study was to analyze the morphometrics of primary second molar and permanent first molar. Samples were consisted of normal occlusion in the primary dentition(50 males and 50 females) and permanent dentition(43 males and 43 females). Their upper and lower plaster casts were used and their measuring points were decided, through 3-dimensional laser scanning(3D Scanner, DS4060, LDI, U.S.A.), fitting standard horizontal plane were made for measuring the intercuspal distance, volume of intercuspal area and section curve. The results were as follows; 1. Average distance from the fit plane to the cusp tips of mandibular primary second molar was smaller than any other tooth. (0.05-0.09 mm in male and 0.04-0.09 mm in female). 2. Intercuspal distances of mandibular primary second molar and permanent first molar were larger in male than in female. Especially, there was statistical significance in primary second molar(p<0.05). 3. Intercuspal distance between distobuccal and distolingual cusp was larger in maxillary primary second molar, except cross intercuspal distances. And distances between distal and distolingual cusp, in mandibular primary second molar, between mesiolingual and mesiobuccal cusp, in maxillary first molar, and between distolingual and mesiolingual cusp, in mandibular first molar were larger than any other intercuspal distance. 4. Volume of intercuspal area of primary second molar and permanent first molar was larger in mandible than in maxilla and that of permanent first molar was 1.40-1.75 times of primary second molar (p<0.05). Also it was larger in male than in female, but there was no statistical significance. 5. In most cases, section curves were wider and deeper in permanent dentition than in primary dentition. Except cross intercuspal distances, in maxilla, section curve between mesiobuccal and mesiolingual cusp was the deepest in both dentition. In mandible, section curve between distobuccal and distal cusp was the deepest in permanent dentition and between distolingual and distal cusp was the deepest in primary dentition.

  • PDF

Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories (동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석)

  • Kang, Min-Young;Lee, Bo-Ram;Kim, You-Hyun;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • The aim of the study is to analyze the dose delivery error depending on the depth variation according to target positions and arc trajectories by comparing the simulated treatment planning with the actual dose delivery in conformal arc therapy. We simulated the conformal arc treatment planning with the three target positions (center, 2.5 cm, and 5 cm in the phantom). For the experiments, IMRT body phantom (I’mRT Phantom, Wellhofer Dosimetry, Germany) was used for treatment planning with CT (Computed Tomography, Light speed 16, GE, USA). The simulated treatment plans were established by three different target positions using treatment planning system (Eclipse, ver. 6.5, VMS, Palo Alto, USA). The radiochromic film (Gafchromic EBT2, ISP, Wayne, USA) and dose analysis software (OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany) were used for the measurement of the planned arc delivery using 6 MV photon beam from linear accelerator (CL21EX, VMS, Palo Alto, USA). Gamma index (DD: 3%, DTA: 2 mm) histogram and dose profile were evaluated for a quantitative analysis. The dose distributions surrounded by targets were also compared with each plans and measurements by conformity index (CI), and homogeneity index (HI). The area covered by 100% isodose line was compared to the whole target area. The results for the 5 cm-shifted target plan show that 23.8%, 35.6%, and 37% for multiple conformal arc therapy (MCAT), single conformal arc therapy (SCAT), and multiple static beam therapy, respectively. In the 2.5 cm-shifted target plan, it was shown that 61%, 21.5%, and 14.2%, while in case of center-located target, 70.5%, 14.1%, and 36.3% for MCAT, SCAT, and multiple static beam therapy, respectively. The values were resulted by most superior in the MCAT, except the case of the 5 cm-shifted target. In the analysis of gamma index histogram, it was resulted of 37.1, 27.3, 29.2 in the SCAT, while 9.2, 8.4, 10.3 in the MCAT, for the target positions of center, shifted 2.5 cm and 5 cm, respectively. The fail proportions of the SCAT were 2.8 to 4 times as compared to those of the MCAT. In conclusion, dose delivery error could be occurred depending on the target positions and arc trajectories. Hence, if the target were located in the biased position, the accurate dose delivery could be performed through the optimization of depth according to arc trajectory.