• Title/Summary/Keyword: 채널 노이즈

Search Result 82, Processing Time 0.028 seconds

Performance Improvement on Fuzzy C-Means Algorithm for Nonlinear Blind Channel Equalization (비선형 블라인드 채널등화를 위한 퍼지 클러스터 알고리즘의 성능개선)

  • Park, Seong-Dae;Han, Su-Hwan
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2007.05a
    • /
    • pp.382-388
    • /
    • 2007
  • In this paper, a modified Fuzzy C-Means (MFCM) algorithm is presented for nonlinear blind channel equalization. The proposed MFCM searches the optimal channel output states of a nonlinear channel from the received symbols, based on the Bayesian likelihood fitness function instead of a conventional Euclidean distance measure. Next, the desired channel states of a nonlinear channel are constructed with the elements of estimated channel output states, and placed at the center of a Radial Basis Function (RBF) equalizer to reconstruct transmitted symbols. In the simulations, binary signals are generated at random with Gaussian noise. The performance of the proposed method is compared with that of a hybrid genetic algorithm (GA merged with simulated annealing (SA): GASA), and the relatively high accuracy and fast searching speed are achieved.

  • PDF

RSF(Royal Sound Field) for the implementation of the various 3-dimensional spatial scene. (다양한 3 차원 공간 구현을 위한 RSF)

  • 라홍운
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.08a
    • /
    • pp.427-431
    • /
    • 1998
  • 스테레오, MIDI, MP3 등등의 신호를 입력으로 하여 음상의 공간감, 거리감, 방향감, 확산감, 위치감 등이 지각을 느끼게 하는 공간적 현장감 시스템을 제안한다. 본 제안은 2채널로 기록된 매체를 2채널 또는 다채널로 표현이 가능하며 영상과 더불어 두 개의 스피커만으로도 입체 음향을 즐길 수 있다. 음악의 경우는 장르에 따라 각각의 특징을 가지고 있다. 그러한 특징은 위치감과 방향감에 의해 음장의 형태를 구현하고 공간감 거리감을 부과하므로 입체 음장 구현을 도모한다. 그리고 확산감을 부과하므로써 실조화 공간 음장을 구현할 수있다. 본 논문은 특정한 음색을 변화하기 위하여 이퀄라이저를 이용할 필요가 없으며, 다양한 음장 형태를 DSP를 이용 알고리즘화 하여 구현하던 것을 본 RSF는 아날로그 방식으로 구현하므로써 노이즈 측면과 PCB 패턴 부분 고려등을 고려하지 않고도 구현할 수 있다.

  • PDF

The research evaluation of shadow influence in NOAA AVHRR data (NOAA AVHRR 자료에서 구름으로 인한 그림자 영향에 관한 조사)

  • Kim, Dong-Hee;Ryutaro, Tateishi;Choi, Seung-Pil;Choi, Chul-Soon
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.281-284
    • /
    • 2004
  • 광범위한 면적의 토지피복분류를 관찰하는데 유용하게 사용되고 있는 NOAA AVHRR 자료는 자료의 방대한 양과 구름에 의한 영향을 없애기 위하여 일반적으로 MVC(Maximum Value Composite) 처리를 하여 사용한다. 그러나 수신당시의 여러 가지 환경인자(구름, 저주파 노이즈, 산란, 구름의 그림자 등)에 의하여 각 채널의 패턴이 변화하여 오독을 할 위험성이 있다. 특히 그림자의 영향에 의해 측정치가 변화하는 NOAA 위성의 채널2영역에서는 이러한 특징이 두드러진다. 따라서 본 연구에서는 지상에서 실제로 측정한 자료를 기초로 하여 NOAA 영상자료에서 구름으로 인한 그림자의 영향에 관하여 조사하였고, 한 픽셀안에서 그림자의 영향이 60%이상이 될 경우에는 오독의 가능성이 높은 것으로 나타났다.

  • PDF

An analysis of the short-term variation of the power line as a communication channel (전력선 통신 채널의 단 구간 변화에 대한 분석)

  • Park, Chong-yeon;Choi, Won-Ho;Jung, Kwang-Hyun
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.21-27
    • /
    • 2007
  • The power line channel has time-variant characteristics caused by various kind of electrical devices. This characteristics are synchronized with the main voltage by their own characteristics. The main factors of disturbance are the variation of the channel impedance and noises. In other papers, the synchronous noise modeling has been achieved. But the modeling is not satisfied simultaneously with the time domain and the frequency domain and there are not any discussion about short-term variations of the channel impedance which cause to the signal fading. Therefore, this paper researched to solve problems about the signal fading by analyzing the short-term variation of the channel impedance, and proposed the synchronous noise modeling which is satisfied simultaneously in the time domain and the frequency domain.

  • PDF

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Image Quality Improvement in Computed Tomography by Using Anisotropic 2-Dimensional Diffusion Based Filter (비등방성 2차원 확산 기반 필터를 이용한 전산화단층영상 품질 개선)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • The purpose of this study was tried to remove the noise and improve the spatial resolution in the computed tomography (CT) by using anisotropic 2-dimensional (2D) diffusion based filter. We used 4-channel multi-detector CT and american association of physicists in medicine (AAPM) phantom was used for CT performance evaluation to evaluate the image quality. X-ray irradiation conditions for image acquisition was fixed at 120 kVp, 100 mAs and scanned 10 mm axis with ultra-high resolution. The improvement of anisotropic 2D diffusion filtering that we suggested firstly, increase the contrast of the image by using histogram stretching to the original image for 0.4%, and multiplying the individual pixels by 1.2 weight value, and applying the anisotropic diffusion filtering. As a result, we could distinguished five holes until 0.75 mm in the original image but, five holes until 0.40 mm in the image with improved anisotropic diffusion filter. The noise of the original image was 46.0, the noise of the image with improved anisotropic 2D diffusion filter was decreased to 33.5(27.2%). In conclusion improved anisotropic 2D diffusion filter that we proposed could remove the noise of the CT image and improve the spatial resolution.

Image Evaluation for A Kind of Patient Fixing Pad in 64 Multi-Channel Detector Computed Tomograph (64 다중채널 검출기 전산화단층촬영에서 환자고정자 재질에 대한 영상평가)

  • Kim, Kee-Bok;Goo, Eun-Hoe
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.1
    • /
    • pp.89-95
    • /
    • 2016
  • The purpose of this experiment intend to evaluate the quality of the image based on the orbit and basal ganglia with high radiosensitivity for the noise, SNR and dose using the five kinds patient fixing pad in brain phantom MDCT(BrillianceTM CT 64 slice, PHILIPS, Netherward). The noise had a higher values in AP than those of others, but the SNR was lower in AP than those of others. The SNR was higher in UP than those of RP, PP, SP and AP. The UP, RP and PP were no statistically significant(p>0.05), whereas it was significant difference between UP, RP, PP and SP, AP(p<0.05). This is causes of the noise difference is generated due to the differences in the radiation absorption dose in accordance with each the component of the absorbed dose level of the detector according to the reference line and each of SOML when the radiation exposured. The CTDIvol(mGy) and DLP of orbit and basal ganglia were 56.95, 911.50, respectively. There is no difference between both mean dose. In conclusion, it is possible to distinguish among a kind of 5 patient fixing pad by using brain phantom MDCT. Overall, patient fixing pad of UP, RP and PP based on a brain phantom MDCT can provide useful information.

Multichannel Transimpedance Amplifier Away in a $0.35\mu m$ CMOS Technology for Optical Communication Applications (광통신용 다채널 CMOS 차동 전치증폭기 어레이)

  • Heo Tae-Kwan;Cho Sang-Bock;Park Min Park
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.8 s.338
    • /
    • pp.53-60
    • /
    • 2005
  • Recently, sub-micron CMOS technologies have taken the place of III-V materials in a number of areas in integrated circuit designs, in particular even for the applications of gjgabit optical communication applications due to its low cost, high integration level, low power dissipation, and short turn-around time characteristics. In this paper, a four-channel transimpedance amplifier (TIA) array is realized in a standard 0.35mm CMOS technology Each channel includes an optical PIN photodiode and a TIA incorporating the fully differential regulated cascode (RGC) input configuration to achieve effectively enhanced transconductance(gm) and also exploiting the inductive peaking technique to extend the bandwidth. Post-layout simulations show that each TIA demonstrates the mid-band transimpedance gain of 59.3dBW, the -3dB bandwidth of 2.45GHz for 0.5pF photodiode capacitance, and the average noise current spectral density of 18.4pA/sqrt(Hz). The TIA array dissipates 92mw p in total from a single 3.3V supply The four-channel RGC TIA array is suitable for low-power, high-speed optical interconnect applications.

Effect of transmit power on the optimal number of feedback bits in dense cellular networks (셀룰러 네트워크에서 송신파워가 최적의 피드백 정보량에 미치는 영향에 관한 연구)

  • Min, Moonsik;Na, Cheol-Hun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.464-466
    • /
    • 2018
  • In this paper, a dense cellular network is considered in which each base station equipped with multiple antennas simultaneously communicates with multiple single-antenna users. Based on limited feedback, each user feeds back its quantized channel state information (CSI) to its associated transmitter, and the transmitter broadcasts multiple data streams prepared for the scheduled users using a space-division multiple access scheme. As the amount of CSI is limited at the transmitter, the downlink throughput increases with the number feedback bits. However, the increased number of feedback bits requires the correspondingly increased amount of uplink resources. Thus, an appropriate balance between the downlink throughput and the uplink resource usage should be considered in realistic systems. A net spectral efficiency defined in this context is used in this paper, and the optimal number of feedback bits that maximizes the net spectral efficiency is analyzed. This paper particularly focuses on the case when the received signal power is much smaller than the noise power.

  • PDF

Ultra-WideBand Channel Measurement with Compressive Sampling for Indoor Localization (실내 위치추정을 위한 Compressive Sampling적용 Ultra-WideBand 채널 측정기법)

  • Kim, Sujin;Myung, Jungho;Kang, Joonhyuk;Sung, Tae-Kyung;Lee, Kwang-Eog
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.285-297
    • /
    • 2015
  • In this paper, Ulta-WideBand (UWB) channel measurement and modeling based on compressive sampling (CS) are proposed. The sparsity of the channel impulse response (CIR) of the UWB signal in frequency domain enables the proposed channel measurement to have a low-complexity and to provide a comparable performance compared with the existing approaches especially used for the indoor geo-localization purpose. Furthermore, to improve the performance under noisy situation, the soft thresholding method is also investigated in solving the optimization problem for signal recovery of CS. Via numerical results, the proposed channel measurement and modeling are evaluated with the real measured data in terms of location estimation error, bandwidth, and compression ratio for indoor geo-localization using UWB system.