• Title/Summary/Keyword: 창호(窓戶)

Search Result 4,172, Processing Time 0.046 seconds

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

A Clinical and Pathological Analysis of Children with Membranoproliferative Glomerulonephritis According to the Clinical Manifestations at Presentation (발견 양상에 따른 소아 막증식성 사구체신염의 임상적 및 병리조직학적분석)

  • Jeon Chang-Ho;Kang Mi-Seon;Chung Woo-Yeong
    • Childhood Kidney Diseases
    • /
    • v.8 no.2
    • /
    • pp.186-194
    • /
    • 2004
  • Purpose: Membranoproliferative glomeulonephritis(MPGN) has been diagnosed in an increasing number of asymptomatic cases. These cases have been detected by school urinary screening test even though the total cases of MPGN show a decreasing trend. We have analyzed the clinical and pathological characteristics of children with MPGN according to the clinical manifestations at the time of disease presentation. Methods: A total of 18 patients who had been diagnosed with idiopathic MPGN by percutaneous renal biopsy from January 1990 to February 2004 were involved in our study. The patients were divided into 2 groups as the school urinary screening(A) group and the symptomatic(S) group according to the clinical manifestations at the time of disease presentation. Results: Out of the total 18 patients, 8(44.4%) were in the S group and 10(55.6%) were in the A group. The mean serum total protein, albumin and $C_3$ levels in the S group were significantly lower than those levels of the A group, respectively($4.9{\pm}1.2\;g/dL,\;vs\;7.0{\pm}0.5\;g/dL\;P=0.002,\;2.8{\pm}0.9\;g/dL\;vs.\;4.1{\pm}0.3\;g/dL\;P=0.002,\;63.9{\pm}36.4\;mg/dL\;vs.\;100.8{\pm}39.5\;g/dL\;P=0.041$). The mean total protein amount of 24 hour collected urine in the S group were significantly higher than that of the A group($3684.0{\pm}2601.3\;mg/m^2\;vs.\;559.4{\pm}4.6.9\;mg/m^2$, respectively, P=0.001). Hypocomplementemia was observed in 11(61.1%) out of 18 patients at the time of disease onset, 7(87.5%) in the S group and 4(40%) in the A group. However the hypocomplementemia was decreased in 6(33.3%) out of 18 patients at the time of final follow-up, 3(37.5%) in the S group and 3(30%) in the A group. According to the pathologic type, hypocomplementemia was observed 8 patients(61.5%) with type I disease, 1 patients (100%) with type II disease, 2 patients(50%) in type III disease at the disease onset, but 4 patients(30.8%) in type I disease, 1 patient(100%) in type II disease, 1 patient(33.3%) with type III disease at the time of last follow-up. The incidence of cellular crescent formation and tubular atropy. as observed on light microscopy, were higher in the S group compared to the A group. Mean grade of capillary wall thickening and, mesangial proliferation were significantly higher in the S group. Conclusion: MPGN, as diagnosed in patients with only asymptomatic urinary abnormalities, has been increasing, it is more frequent in asymptomatic patients than in patients with presenting symptoms. Our result suggests that MPGN should be considered in the renal biopsy diagnosis regardless of serum $C_3$ level when urinary abnormalities are found by school urinary screening test.

  • PDF

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF

Effects of Benzo〔a〕pyrene on Growth and Photosynthesis of Phytoplankton (식물플랑크톤의 성장과 광합성에 대한 benzo〔a〕pyrene의 영향)

  • Kim, Sun-Ju;Shin, Kyung-Soon;Moon, Chang-Ho;Park, Dong-Won;Chang, Man
    • Korean Journal of Environmental Biology
    • /
    • v.22
    • /
    • pp.54-62
    • /
    • 2004
  • We examined the impacts of anthyopogenic pollutant (benzo〔a〕pyrene) on the growth and photosynthesis of five marine phytoplankton species (Skeletonema costatum, Heterosigma akashiwo, Prorocentrum dentatum, P. minimum, Aknshiwo sanguinea), which are dominant in Korean coastal water. After the 72 h exposure to benzo〔a〕pyrene, the dramatic decrease in cell numbers was observed in the range of 1 to 10 $\mu\textrm{g}$ L$^{-1}$ for S. costatum, P. minimum, P. dentatum, whereas for A. sanguinea and H. akashiwo at the low concentrations 0.1 to 1 $\mu\textrm{g}$ L$^{-1}$ . Among the 5 phytoplankton species, the highest growth inhibition concentration ($IC_{50}$/) was 6.20 $\mu\textrm{g}$ L$^{-1}$ for P. minimum, followed by 2.14 $\mu\textrm{g}$ L$^{-1}$ for P. dentatum, 1.68 $\mu\textrm{g}$ L$^{-1}$ for S. costatum, 0.74 $\mu\textrm{g}$ L$^{-1}$ for H. akashiwo, 0.10 $\mu\textrm{g}$ L$^{-1}$ for A. sanguinea. The five species exposed to the low concentration of 1 $\mu\textrm{g}$ L$^{-1}$ were recovered after transferring to new media, but the species exposed to the high concentrations of 10 and 100 $\mu\textrm{g}$ L$^{-1}$ were not recovered, with the exception of P. minimum. Those results indicate that the thecate dinoflagellate P. minimum is most tolerant to the chemical and the athecate dinoflagellate A. sanguinea is not. Geneyally, the cell-specific photosynthetic capacity of H. akashiwo exposed to the low concentrations of 0.1 and 1 $\mu\textrm{g}$ L$^{-1}$ was higher than that of the cells in the control, whereas the cells exposed to the high concentrations of 5 and 10 $\mu\textrm{g}$ L$^{-1}$ showed the negligible photosynthetic level by the first few days of the experiment. In the case of the cells exposed to the concentration of 5 $\mu\textrm{g}$ L$^{-1}$ , after 12 days of the experiment the photosynthetic capacity was increased toward the end of the experiment. This indicates that H. akashiwo may utilize the benzo〔a〕pyrene as a carton source for its growth when exposed to low concentrations. Results suggest that anthropogenic pollutants such as benzo〔a〕pyrene may have significant influence on the succession of phytoplankton species composition and the primary production in coastal marine environments.

Eating Traits and General Psychopathology of Korean Males Who Show High Score on the Korean Version of Eating Attitudes Test-26 (한국판(韓國版) 식사태도(食事態度) 검사(檢査)-26에서 고득점(高得點)을 보인 한국(韓國) 일반(一般) 남성군(男性群)의 식사특성(食事特性)과 일반정신병리(一般精神病理))

  • Han, Ki-Seok;Lee, Young-Ho;Rhee, Min-Kyu;Park, Se-Hyun;Sohn, Chang-Ho;Chung, Young-Cho;Hong, Sung-Kook;Lee, Byung-Kwan;Chang, Phi-Lip;Yoon, A-Rhee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.7 no.1
    • /
    • pp.87-102
    • /
    • 1999
  • Objectives : The purposes of this study were to estimate the prevalence rate of eating disorders in Korean males and to clarify their characteristics in sociodemograhic data, the eating traits, and general psychopathology through the comparison with those of female high scored group on the Korean version of Eating Attitudes Test-26(KEAT-26). Methods : Using a multi-stage questionnaire sampling method including area sampling, proportionated stratified sampling, and quota sampling, we surveyed a total of 4,400 Korean adults over 18 in a nationwide area(9 kus, 10 middle or small cities, and 17 kuns), obtaining usable responses on 3,896. Of the 3,062 subjects(1249 males and 1813 females) who were available for analysis, we ascertained 52 males and 208 females who had high score($\geq$ cutoff point 21) on the KEAT-26. Results : 1) The proportion of this high score group was 1.7% in male and 6.8% in female with a sex ratio(male versus female) of 1 : 4. 2) The mean age was higher in the male group than in the female group, although it was not statistically significant(p=0.0514). Mean Body Mass Index(BMI) of the male group was significantly higher than that of female group, and the number of male subjects with below 20 of BMI was also significantly lower than in the female group. 3) There were no significant difference in past history of physical illness between two groups. However, frequency of smoking and alcohol use, and mean amount of alcohol consumption per month were significantly higher in the male group than in the female group. There were no significant differences between the two groups on various socio-demographic correlates such as economic status, total duration of education, number of family, marital status, religious status, and area of residence, but the exception of being occupational status. 4) The 'Eating Habits Scale' score and score of 'preference for vegetables and fish, and dislike for sweet-tasting food' of the male group were significantly lower than those of the female group. Although there was no significant difference between the two groups in total scores of the KEAT-26, the mean score on 'pursuit of thinness' subscale was higher in the female group than in the male group, while scores of 'food preoccupation' and 'self-control' subscales were higher in the male group than in the female group. 5) Scores on 'psychoticism' was significantly higher in the male group than in the female group, although there were no significant differences between the two groups on 'locus of control for weight', 'depression' and 'hypochondriasis'. Conclusion : These results support a possibility of a high prevalence of eating disorders in Korean males. These results suggest that eating related characteristics of high scorer on the EAT are different by sex in spite of the same high score on the EAT, and also suggest that male patients with eating disorders have more serious personality pathology than female patients with eating disorders.

  • PDF

Historical Studies on the Characteristics of Buyongjeong in the Rear Garden of Changdeok Palace (창덕궁 후원 부용정(芙蓉亭)의 조영사적 특성)

  • Song, Suk-ho;Sim, Woo-kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.1
    • /
    • pp.40-52
    • /
    • 2016
  • Buyongjeong, a pavilion in the Rear Garden of Changdeok Palace, was appointed as Treasure No. 1763 on March 2, 2012, by the South Korea government since it shows significant symmetry and proportion on its unique planar shape, spatial configuration, building decoration, and so forth. However, the designation of Treasure selection was mainly evaluated by concrete science, in that the selection has not clearly articulated how and why Buoungjeong was constructed as a present unique form. Therefore, this study aims to clarify the identity of Buyongjeong at the time of construction by considering its historical, ideological, philosophical background and building intention. Summary are as follows: First, Construction backgrounds and characters of Buyongjeong: Right after the enthronement, King Jeongjo had founded Kyujanggak(奎章閣), and sponsored civil ministers who were elected by the national examination, as a part of political reform. In addition, he established his own political system by respecting "Kaksin(閣臣)", Kyujanggak's officials as much as "Kain(家人)", internal family members. King Jeongjo's aggressive political reform finally enabled King's lieges to visit King's Rear Garden. In the reign of King Jeongjo's 16th year(1792), Naekaksangjohoe(內閣賞釣會) based on "Kaksin" was officially launched and the Rear Garden visitation became a regular meeting. The Rear Garden visitation consisted of "Sanghwajoeoyeon(賞花釣魚宴)" - enjoying flowers and fishing, and activities of "Nanjeongsugye". Afterward, it eventually became a huge national event since high rank government officials participated the event. King Jeongjo shared the cultural activities with government officials together to Buyongjeong as a place to fulfill his royal politics. Second, The geographical location and spatial characteristics of Buyongjeong: On the enthronement of King Jeongjo(1776), he renovated Taeksujae. Above all, aligning and linking Gaeyuwa - Taeksujae - a cicular island - Eosumun - Kyujangkak along with the construction axis is an evidence for King Jeongjo to determine how the current Kyujangkak zone was prepared and designed to fulfill King Jeonjo's political ideals. In 17th year(1793) of the reign of King Jeongjo, Taeksujae, originally a square shaped pavilion, was modified and expanded with ranks to provide a place to get along with the King and officials. The northern part of Buyongjeong, placed on pond, was designed for the King's place and constructed one rank higher than others. Discernment on windows and doors were made with "Ajasal" - a special pattern for the King. The western and eastern parts were for government officials. The center part was prepared for a place where government officials were granted an audience with the King, who was located in the nortern part of Buyongjeong. Government officials from the western and eastern parts of Buyongjeong, could enter the central part of the Buyongjeong from the southern part by detouring the corner of Buyongjeong. After all, Buyongjeong is a specially designed garden building, which was constructed to be a royal palace utilizing its minimal space. Third, Cultural Values of Buyongjeong: The Buyongjeong area exhibits a trait that it had been continuously developed and it had reflected complex King's private garden cultures from King Sejo, Injo, Hyunjong, Sukjong, Jeongjo and so forth. In particular, King Jeongjo had succeded physical, social and imaginary environments established by former kings and invited their government officials for his royal politics. As a central place for his royal politics, King Jeongjo completed Buyongjeong. Therefore, the value of Buyongjeong, as a garden building reflecting permanency of the Joseon Dynasty, can be highly evaluated. In addition, as it reflects Confucianism in the pavilion - represented by distinguishing hierarchical ranks, it is a unique example to exhibit its distinctiveness in a royal garden.

Study on the Evaluation of Renal Function According to Set a Partial Region of Interest in 99mTc-DMSA scan of the Pediatric Patient with a Duplicated Ureter (중복요관을 가진 소아환자의 99mTc-DMSA 검사에서 부분적 관심영역 설정에 따른 신기능 평가에 관한 연구)

  • Nam-Koong, Hyuk;Oh, Shin Hyun;Kim, Jung Yul;Choi, Yoon Jung;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.43-47
    • /
    • 2013
  • Purpose: A duplicated ureter is congenital renal malformations with ureter in two. Patients with duplicated ureter are in force to $^{99m}Tc-DMSA$ scan at surgery before and after. In existing examination, at produce result after $^{99m}Tc-DMSA$ scan, didn't compare to upper pole and lower pole with malformed kidney and compared to only relative uptake ratio. Therefore, this study will examine about utility of set a partial region of interest and to functional recovery of renal cell through change of upper pole uptake ratio of malformed kidney by setting each partial region of interest in upper pole and lower pole of malformed kidney in $^{99m}Tc-DMSA$ examination in surgery before and after. Materials and Methods: Pediatric patients with malformed kidney of incomplete duplicated ureter, 15 patients were enrolled in this study. Scanning were scan 3 to 4 hours after injection of $^{99m}Tc-DMSA$ 1.5 ~ 1.9 MBq/kg. Region of interest were each set in normal kidney, upper pole and lower pole with malformed kidney. Region of interest were set with same condition and method to images of surgery before and after that radio technologist 1 person, resident of nuclear medicine 1 person and doctor of urology together. Therefore, this study were compared to uptake ratio (A: B: C) that normal kidney (A), lower pole of malformed kidney (B) and upper pole of malformed kidney (C) about uptake ratio changes of malformed kidney in follow-up examination of surgery before and after. Results: When compared to 15 patients, uptake ratios were increased 7 persons and decreased 8 persons. Among increased 7 persons, it were periods of follow-up examination that 2 persons were 14 months, 4 persons were 12 months and 1 person was 8 months after surgery. Among decreased 8 persons, it were periods of follow-up examination that 4 persons were 12 months 3 persons were 6 months and 1 persons were 4 months after surgery. Conclusion: Existing study could not see the exact uptake ratio changes of malformed kidney because using only the overall Left-Right kidney uptake ratios. But a setting partial region of interest was able to see exactly what changes in the uptake of each upper pole and lower pole of malformed kidney. Because recovery of renal parenchymal cells is difficult in an evaluation of short period of time, follow-up examination should be made in long period of time. How to set up partial region of interest be thought that it would be useful.

  • PDF

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF