The Study of Radiation Reducing Method during Injection Radiopharmaceuticals

방사성의약품 투여 시 피폭선량 저감에 대한 연구

  • Cho, Seok-Won (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Jung, Seok (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Park, June-Young (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Oh, Shin-Hyun (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • NamKoong, Hyuk (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Oh, Ki-Beak (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Jae-Sam (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Lee, Chang-Ho (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System)
  • 조석원 (연세의료원 세브란스병원 핵의학과) ;
  • 정석 (연세의료원 세브란스병원 핵의학과) ;
  • 박준영 (연세의료원 세브란스병원 핵의학과) ;
  • 오신현 (연세의료원 세브란스병원 핵의학과) ;
  • 남궁혁 (연세의료원 세브란스병원 핵의학과) ;
  • 오기백 (연세의료원 세브란스병원 핵의학과) ;
  • 김재삼 (연세의료원 세브란스병원 핵의학과) ;
  • 이창호 (연세의료원 세브란스병원 핵의학과)
  • Received : 2012.02.28
  • Accepted : 2012.04.06
  • Published : 2012.04.28

Abstract

Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

전신 골 스캔은 골친화성 방사성의약품으로 뼈의 생리적 변화를 영상화하는 검사방법으로, 140 keV의 감마선을 방출하는 방사성핵종이 표지된 방사성의약품을 주사 후 촬영하는 영상기법이다. 외부피폭으로부터 방사선방호의 3원칙은 시간, 거리, 차폐이다. 방사성의약품은 투여 시 개봉선원이 되기 때문에 방사선방호 원칙에 따라 피폭을 줄이기 위하여 빠른 시간 내에 주사하는 것이 좋다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없는 제한점이 있다. 본 연구는 방사성의약품으로부터 거리에 따른 피폭선량 변화를 확인하고, 차폐체를 사용 후 피폭량의 변화를 관찰하여 방사선 종사자의 피폭 관리에 도움이 되고자 한다. 방사성의약품 투여 시 소요되는 주사시간의 평균을 구하기 위하여 훈련된 주사 담당자가 환자에게 주사하는 시간을 총 50회 측정하였고, 그 평균값(약 2분)을 구하였다. 1 mL주사기에 옥시드로산테크네슘 925 MBq를 0.2 mL 로 맞춘 다음 50 cm, 100 cm, 150 cm, 200 cm에서 방사선 측정기(FH-40, Thermo Scientific, USA)로 선량을 측정하였다. 그리고 방사선차폐체(납 6 mm)를 선원으로부터 25 cm에 설치 한 후 50 cm 거리에서 선량을 측정하였다. 모든 선량측정은 각각 20회에 걸쳐 재현성을 검증하였다. 차폐 전과 차폐 후의 선량의 상관관계는 SPSS (ver. 18)을 사용하여 paired t-test로 검증하였다. 차폐체를 설치하지 않은 선원으로부터 거리에 따른 2분간 받는 피폭량은 50 cm에서 $1.986{\pm}0.052{\mu}Sv$, 100 cm에서 $0.515{\pm}0.022{\mu}Sv$, 150 cm에서 $0.251{\pm}0.012{\mu}Sv$, 200 cm에서 $0.148{\pm}0.006{\mu}Sv$로 나타났다. 차폐를 설치 후 측정 시 피폭량은 $0.035{\pm}0.003{\mu}Sv$로 차폐체 사용 전과 후의 피폭선량은 통계적으로 유의한 차이가 있는 것으로 나타났다($p$<0.001).전신 골스캔은 핵의학 검사에서 많은 비중을 차지하고 있기 때문에 방사성의약품 투여 시 피폭을 줄이기 위해서 외부피폭의 방어원칙을 적절히 병행하여 피폭 저감을 위해 노력해야 한다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없고, 환자의 혈관 확보가 어려운 경우 주사시간이 길어질 수 있다. 본 연구를 통해 거리가 멀어짐에 따라 피폭선량이 감소하는 것을 확인하였고, 선원으로부터25 cm 거리에 차폐체 설치 시 피폭선량이 감소하는 것을 확인할 수 있었다. 본 연구를 통해 방사성의약품 투여 시 차폐체를 사용함으로써 방사선 피폭 저감에 도움이 될 것으로 사료된다.