PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT

  • 조석원 (연세의료원 세브란스병원 핵의학과) ;
  • 박훈희 (연세의료원 세브란스병원 핵의학과) ;
  • 김정열 (연세의료원 세브란스병원 핵의학과) ;
  • 반영각 (연세의료원 세브란스병원 핵의학과) ;
  • 임한상 (연세의료원 세브란스병원 핵의학과) ;
  • 오기백 (연세의료원 세브란스병원 핵의학과) ;
  • 김재삼 (연세의료원 세브란스병원 핵의학과) ;
  • 이창호 (연세의료원 세브란스병원 핵의학과)
  • Cho, Seok-Won (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Park, Hoon-Hee (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Jung-Yul (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Ban, Yung-Kak (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Lim, Han-Sang (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Oh, Ki-Beak (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Jae-Sam (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Lee, Chang-Ho (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System)
  • 투고 : 2010.08.13
  • 심사 : 2010.08.27
  • 발행 : 2010.10.30

초록

방사선 분야는 건강검진의 증가와 방사선 장치의 발달로 진단에서 치료까지 그 업무의 범위가 확대 및 급격히 증가하고 있으며 방사선 종사자의 방사선 피폭 관리가 중요하게 대두되고 있다. PET 검사에 이용되는 양전자 방출핵종은 511 keV의 감마선을 방출하기 때문에 종사자의 방사선 피폭의 증가로 피폭선량 저감을 위한 노력이 요구된다. 본 연구는 환자에게로부터 일정거리 외부선량률을 측정하고 거리에 따른 선량률 변화를 확인하고 차폐를 이용하여 외부선량률의 변화를 알아보았다. 2009년 12월부터 2010년 1월까지 PET/CT 검사를 위해 내원한 10명의 환자를 대상으로 하였다. Digital surveymeter를 이용하여 선량률을 측정하였다. 산란선에 대한 영향을 평가하기 위해서 이동식 방사선 차폐체를 설치하고 왼쪽, 중앙, 오른쪽 부분의 100 cm, 150 cm, 200 cm에서 총 12회 선량률을 측정하였다. 환자 선량률 측정은 $^{18}F$-FDG 5.18 MBq/kg을 주사하고 1시간이 지난 후에 선량이 안정되었을 때 즉시 1회를 측정하였다. 이동식 방사선 차폐체를 설치하기 전에 머리, 가슴, 복부, 무릎, 발끝 쪽의 위치에서 10 cm, 50 cm, 100 cm, 150 cm, 200 cm 위치로 총 80포인트에서 측정하였고 이동형 방사선 차폐체를 설치한 후 머리와 가슴, 복부 부분에서 100 cm, 150 cm, 200 cm 거리의 선량률을 측정하여 외부선량률을 확인하였다. 산란선 측정에 대해서는 위치별로 거리에 따라 분산분석을 시행하였다. 납 차폐를 하지 않았을 때와 차폐를 했을 때의 등선량곡선을 그렸으며 100 cm, 150 cm, 200 cm에 대하여 두 집단간에 상관분석을 시행하였다(SPSS ver. 12). 점 선원을 이용한 산란선 측정에서 100 cm, 150 cm, 200 cm에서는 p>0.05로 유의한 차이가 없었다. 거리가 멀어질수록 선량률이 낮아졌으며 머리 부분이 가장 높은 선량률이 나타났고 발 부분으로 갈수록 선량률이 떨어졌다. 또한 차폐를 하였을 경우 차폐를 하지 않았을 때보다 선량률이 낮아졌으며 100 cm에서 유의한 차이가 있었고(p<0.05) 150 cm, 200 cm에서는 유의한 차이가 없었다(p>0.05). 피폭을 줄이기 위해서는 방사선원에서 거리를 멀리하거나 적당한 차폐체를 이용하는 것이 피폭저감에 도움을 준다. 근무자의 동선을 파악하여 적당한 차폐체를 이용한다면 방사선 종사자의 방사선 피폭을 줄일 수 있을 것이다.

Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

키워드