Analysis of airborne sound insulation performance by the experiment using small size specimen (축소시편 실험을 통한 공기전달음 차단성능 분석)

  • Kim, Hang;Park, Hyeon Ku;Goo, Hee Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • The residents' demand for the comfortable life is promoting development of wall and window which has high sound insulation performance. To develop wall system, various aspects should be considered on the environment, material, construction and structure. Especially focusing on the acoustical view, the economical solution is one of the most critical point. Recently the interest on the partition wall is being increased, because it is useful for the Rahmen type apartment which is considered as an alternative to reduce floor impact sound. This study examines simplified measurement method of airborne sound insulation applied small size specimen, in order to save money to be used for the standard specimen then to promote the development process. The results showed that the simplified method could be effective for the wall system the sound insulation performance upto Rw 50 dB, and for the judgement of rank order of sound insulation performance of the similar wall type while developing.

The Experimental Study on the Impact Sound Insulation Floors due to Waste Tire Chip (폐타이어 칩의 바닥충격음 차단성능에 관한 실험적 연구)

  • 양관섭;이세현;김홍열;김승민
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.477-484
    • /
    • 1999
  • This study aims to present proper thickness of resilient mount and pattern of chips for the improvement of impact sound isolation. To achieve this aim, field tests were performed to evaluate the performance of impact sound isolation of pilot samples using waste tire chips against light and heavy-weight impacter, which samples were installed over concrete slabs of an apartment housing. In this study, the experiments were performed by the impact sound level of floors in KS F 2810 "Method for field measurement of floor impact level". As results, a flooring structure using waste tire chips as a resilient mount, with no relation to chip's types, has enhanced performance by 1~2 degree in light impact sound isolation, while it has improvement in heavy impact sound isolation. And fiber-type chips have better performance than granule-type ones when they overlaid concrete slab with 15~20 mm of thickness. For the improvement of impact sound isolation, it is recommended that insulating materials should be applied at joints between floating floors and walls, or floating floors and a doorframes, and also waterproof papers should be used for the effective thickness of resilient mount.ent mount.

  • PDF

Malicious Traffic Protection through MSPI Designing (MSPI설계를 통한 유해 트래픽 차단)

  • Noh, Si-Choon
    • Convergence Security Journal
    • /
    • v.6 no.2
    • /
    • pp.31-42
    • /
    • 2006
  • In this paper, we proposed an integrated infrastructure for optimal information security to resolve these kinds of problems and to implement more powerful protection. The proposed infrastructure presents a security framework, provides a functional mechanism, and implements a scheme for information security based on the design concept of integrated structures. In order to ensure effective malicious traffic blocking, this paper emphasizes that a comprehensive approach through infrastructure improvement and combination of scanning tool is the only measure for preparing against today's environment of virus infiltration. The proposed model is a measure developed at a time when a permanent technological solution to virus is yet to be developed. A performance analysis model is developed and the performance is evaluated through the case studies for the proposed methodology. The effectiveness of the infrastructure for optimal information security needs the continuous diagnostic evaluation and tuning through the users or the organizations.

  • PDF

Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source (표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가)

  • Yong-Bong Lee;Hyok-Je Kwon;Chang-Whan Kim;Man-Hee Cho;Hang Kim;SungSoo Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • In this paper, a method for evaluating the measurement uncertainty is proposed when measuring of floor impact sound insulation of buildings using standard heavy impact source. In addition to the effect of repeated measurements, several other factors such as measurement location, impact location, equipment used for sound pressure measurement, and heavy impact source, were considered. A mathematical model for the average maximum impact sound level and the uncertainty evaluation method for each factor were proposed. The present proposed method was applied to measurement results to evaluate the average maximum impact sound pressure level and the measurement uncertainty.

SRR and CSRR Loaded UWB Antenna with Tri-Band Notch Capability (SRR과 CSRR을 이용한 삼중 대역 차단 초광대역 안테나)

  • Yoo, Min-Yeong;Lim, Sung-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.320-327
    • /
    • 2012
  • In this paper, a novel ultra wide band(UWB) antenna with tri-band notch capability is proposed. The proposed antenna can reject WiMAX(3.3~3.7 GHz), WLAN IEEE 802.11a/n(5.15~5.825 GHz), and ITU(8.025~8.4 GHz) bands. Band rejection capability is achieved only split ring resonators(SRRs) and complementary SRRs(CSRRs). The SRR under the radiating patch, the CSRR loaded on the radiating patch, and the CSRRs on the ground of the CPW feeding reject the WiMAX, WLAN, and ITU bands, respectively. The simulation and measurement results demonstrate the performances of the proposed antenna.

Performance Analysis of Reliability Based On Call Blocking Probability And Link Failure Model in Grid Topology Circuit Switched Networks (격자 구조 회선 교환망에서의 호 차단 확률 및 Link Failure Model에 근거한 신뢰도 성능 분석)

  • 이상준;박찬열
    • Journal of the Korea Society of Computer and Information
    • /
    • v.1 no.1
    • /
    • pp.25-36
    • /
    • 1996
  • We have analyzed the reliability of failure models In grid topology circuit switched networks. These models are grid topology circuit_ switched networks. and each node transmits packets to object node using flooding search routing method. We hypothesized that the failure of each link Is Independent. We have analyzed for the performance estimation of failure models It using joint probability method to the reliability of a small grid topology circuit switched network. and compared analytic output with simulated output. Also. We have evaluated the reliability of networks using call blocking Probability occurred in circuit switched networks.

  • PDF

Study on the Performance Verification Method and Failure Mechanism of Grading Capacitor of a Two-break Circuit-breaker (2점절 차단기 균압용 콘덴서 절연파괴 고장 메커니즘 및 성능검증 방법에 관한 연구)

  • Oh, SeungRyle;Han, Kisun;Kim, TaeKyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2019
  • Recently, the circuit-breaker rated voltage is getting higher as the transmission voltage increases. To increase the circuit-breaker rated voltage, a multi-break circuit-breaker which has two or more breakers in series is adopted. For multi-break circuit-breaker, a grading capacitor is used to mitigate the Transient Recovery Voltage(TRV) and control the voltage distribution across the individual interrupter units. However, all over the world, there are many failures such as mechanical damage, explosion due to insulation breakdown. Therefore, it is necessary to study the causes of failure and the new performance verification method. In this paper, we investigate the causes of dielectric breakdown of the grading capacitors in the KEPCO power system and propose the performance verification method.

Convergence Performance Evaluation Model for Intrusion Protection System based on CC and ISO Standard (CC와 ISO 표준에 따른 침입방지시스템의 융합 성능평가 모델)

  • Lee, Ha-Yong;Yang, Hyo-Sik
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.251-257
    • /
    • 2015
  • Intrusion protection system is a security system that stop abnormal traffics through automatic activity by finding out attack signatures in network. Unlike firewall or intrusion detection system that defends passively, it is a solution that stop the intrusion before intrusion warning. The security performance of intrusion protection system is influenced by security auditability, user data protection, security athentication, etc., and performance is influenced by detection time, throughput, attack prevention performance, etc. In this paper, we constructed a convergence performance evaluation model about software product evaluation to construct the model for security performance evaluation of intrusion protection system based on CC(Common Criteria : ISO/IEC 15408) and ISO international standard about software product evaluation.

Improving the performance of Multipath TCP using Delay Alerted Path-blocking Scheduler in Heterogeneous Networks (이종 망에서의 지연경보 경로차단 스케줄러를 이용한 MPTCP성능 개선방안)

  • Kim, Min Sub;Lee, Jae Yong;Kim, Byung Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.2
    • /
    • pp.28-37
    • /
    • 2017
  • Multipath TCP (MPTCP), which is a layer 4 protocol that can get the reliability and the efficiency of the transmission by using multipath transfer, was standardized by the IETF. MPTCP provides superior performance when compared to a single TCP when used in a homogeneous network with similar network characteristics. However, MPTCP degrades performance when used in heterogeneous networks with different network characteristics. In this paper, we propose 'Delay-alerted path-blocking scheduler'. It measures the delay of each path and blocks the path with a long delay to reduce the order of packets in the receive buffer. If the duplicated packet is sent to the blocked path to measure the delay and the congestion on the blocking path is reduced, the blocked path is unblocked. For performance analysis, the proposed scheduler was implemented in the Linux kernel and improved performance was obtained in the test bed. We also confirmed that the proposed scheduler reduces the degradation of MPTCP performance in real wireless networks with heterogeneous path characteristics.

Development of PTC elements for limiting short circuit current in low voltage power systems (저압계통의 단락전류 제한을 위한 PTC 소자 개발)

  • Kang, J.S.;Lee, B.W.;Oh, I.S.;Kwon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.18-20
    • /
    • 2005
  • 일반적으로 저압계통의 고장전류를 차단하기 위해 설치된 차단기의 차단원리는 주로 역전압발생법올 이용하고 있다. 역전압발생법은 효과적으로 저압계통의 고장전류를 차단할 수 있으나, 제한된 한류성능과 긴 아킹 시간은 차단기는 물론 주변 전력기기에 전기적/열적/기계적 스트레스를 주게 된다. 국내외 업체는 고장전류를 보다 빠르고 효과적으로 제한 및 차단을 할 수 있는 한류형 차단기를 제안하고 있는 실정이다. 저압계통의 경우, 정온도계수 (Positive Temperature Coefficient, PTC) 특성을 가지는 한류소자를 기존 차단기에 직렬 혹은 병렬로 연결하여 저압계통의 고장전류를 매우 빠르고 효과적으로 제한 및 차단하는 추세에 있으며, 또한 PTC 한류소자를 이용함으로써 저압계통의 차단보호협조를 효과적으로 구현하고자 하고 있다. PTC 한류소자는 소자는 열팽창이 큰 비전도성 성분과 열팽창이 작은 전도성 성분이 혼합되어 구성되며, 소자의 온도가 증가함에 따라 비전도성 성분이 상대적으로 큰 부피 팽창을 하여 저항이 증가하게 된다. 이러한 PTC 소자를 전력계통에 적용함으로써 고장전류에 따른 줄열에 의한 저항증가로 고장전류를 제한하게 된다. 본 연구에서는 일반적으로 배터리 보호용으로 사용되는 폴리에틸렌 수지 및 카본블랙으로 구성된 폴리머 PTC 한류소자를 이용하여, 기존의 저전력 배터리 보호 폴리머 PTC 소자로부터, 저압계통의 단락사고시 발생하는 단락전류를 효과적으로 제한할 수 있는 대전력 폴리머 PTC 소자를 개발하였다.

  • PDF