• Title/Summary/Keyword: 증폭기

Search Result 2,119, Processing Time 0.026 seconds

A Design of Correlator with the PBS Architecture in Binary CDMA System (Binary CDMA 시스템에서 PBS 구조를 가지는 코릴레이터 설계)

  • Lee, Seon-Keun;Jeong, Woo-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.3
    • /
    • pp.177-182
    • /
    • 2008
  • Because output of multi-code CDMA system adapted high speed data transmission becoming multi-level system use linear amplifier in output stage and complex output signal. Therefore, Multi-Code CDMA system has shortcoming of high price, high complexity etc. Binary CDMA technology that allow fetters in existing CDMA technology to supplement this shortcoming proposed. In binary CDMA system When correlator process high speed data, bottle-neck phenomenon is happened on synchronization acquisition process, it is very important parameter. Because existent correlator must there be advantage that power consumption is small but flow addition of several stages to receive correlation's value, the processing speed has disadvantage because the operation amount is much. Therefore in this paper, proposed correlator has characteristic such as data is able to high speed processing, chip area is independent and power consumption is constant in structure in binary CDMA system.

  • PDF

A FSK Radio-telemetry System for Monitoring Vital Signs in UHF Band (UHF 대역 FSK에 의한 생체신호 무선 전송장치의 개발)

  • Park D.C.;Lee H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.255-260
    • /
    • 2000
  • This paper presents a radio-telemetry patient monitor. which is used for intensive cal?e units. emergency and surgical operation rooms to monitor continuously patients' vital signs. The radio-telemetry patient monitor consists of a vital sign acquisition unit. wireless data transmission units and a vital sign-monitoring unit. The vital sign acquisition unit amplifies biological signals, performs analog signal to serial digital data conversion using the one chip micro-controller. The converted digital data is modulated FSK in UHF band using low output power and transmitted to a remote site in door. In comparison with analog modulation. FSK has major advantages to improve performance with respect to noise resistance with fower error and the potential ability to process and Improve quality of the received data. The vital sign-monitoring unit consists of the receiver to demodulate the modulated digital data, the LCD monitor to display vital signs continuously and the thermal head printer to record a signal.

  • PDF

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF

A Study on the Protocol Design and Implementation for an Underwater Acoustic Multi-channel Digital Communication (수중 초음파 디지탈 이동통신을 위한 프로토콜 설계 및 구현에 관한 연구)

  • 박연식;임재홍
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.179-189
    • /
    • 2000
  • Recently, due to the increasing interests in deep sea development, all possible efforts to the development of underwater unmanned working vehicles such as AUV(Autonomous Underwater Vehicle) or underwater robot are exerted. This paper proposes a new efficient acoustic-based underwater image data communication system, which ensures a certain level of maximum throughput regardless of the propagation delay of ultrasonic and allowsfast data transmission through the multiple ultrasonic communication channel. Proposed system consists of an acoustic transducer which operates at 136kHz center frequency and it's 10kHz bandwidth, pre-amplifier, $\pi/4 QPSK$(Quadrature Phase Shift Keying) modulation/demodu-lation method, image compressing method using JPEG technique and modified Stop & Wait protocol. The experimental result of the system make it possible to transfer the underwater image as a high throughput at the basin test. The results of test are also verified which allows to desirable transmission performance compared with the existing developed system and the possibility to put the practical use of survey and investigation in the water.

  • PDF

A $0.13-{\mu}m$ CMOS Active-RC Filter for LTE-Advanced Systems (LTE-Advanced 표준을 지원하는 $0.13-{\mu}m$ CMOS Active-RC 필터 설계)

  • Lee, Kyoung-Wook;Kim, Jong-Myeong;Park, Min-Kyung;Hyun, Seok-Bong;Jung, Jae-Ho;Kim, Chang-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.396-397
    • /
    • 2011
  • This paper has proposed a multi-channel low pass filter (LPF) for LTE-Advanced systems. The proposed LPF is an active-RC 5th chebyshev topology with three cut-off frequencies of 5 MHz, 10 MHz, and 40 MHz. A 3-bit tuning circuit has been adopted to prevent variations of each cut-off frequency from process, voltage, and temperature (PVT). To achieve a high cut-off frequency of 40 MHz, an operational amplifier used in the proposed filter has employed a PMOS cross-connection load with a negative impedance. A proposed filter has been implemented in a $0.13-{\mu}m$ CMOS technology and consumes 20.2 mW with a 1.2V supply voltage.

  • PDF

Design of a Small-Area, Low-Power, and High-Speed 128-KBit EEPROM IP for Touch-Screen Controllers (터치스크린 컨트롤러용 저면적, 저전력, 고속 128Kb EEPROMIP 설계)

  • Cho, Gyu-Sam;Kim, Doo-Hwi;Jang, Ji-Hye;Lee, Jung-Hwan;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2633-2640
    • /
    • 2009
  • We design a small-area, low-power, and high-speed EEPROM for touch screen controller IC. As a small-area EEPROM design, a SSTC (side-wall selective transistor) cell is proposed, and high-voltage switching circuits repeated in the EEPROM core circuit are optimized. A digital data-bus sensing amplifier circuit is proposed as a low-power technology. For high speed, the distributed data-bus scheme is applied, and the driving voltage for both the EEPROM cell and the high-voltage switching circuits uses VDDP (=3.3V) which is higher than the logic voltage, VDD (=1.8V), using a dual power supply. The layout size of the designed 128-KBit EEPROMIP is $662.31{\mu}m{\times}1314.89{\mu}m$.

Design of Low Dropout Regulator using self-cascode structure (셀프-캐스코드 구조를 적용한 LDO 레귤레이터 설계)

  • Choi, Seong-Yeol;Kim, Yeong-Seuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.993-1000
    • /
    • 2018
  • This paper proposes a low-dropout voltage regulator(LDO) using self-cascode structure. The self-cascode structure was optimized by adjusting the channel length of the source-side MOSFET and applying a forward voltage to the body of the drain-side MOSFET. The self-cascode of the input differential stage of the error amplifier is optimized to give higher transconductance, but the self-cascode of the output stage is optimized to give higher output resistance, The proposed LDO using self-cascode structure was designed by a $0.18{\mu}m$ CMOS technology and simulated using SPECTRE. The load regulation of the proposed LDO regulator was 0.03V/A, whereas that of the conventional LDO was 0.29V/A. The line regulation of the proposed LDO regulator was 2.23mV/V, which is approximately three times improvement compared to that of the conventional LDO. The transient response of the proposed LDO regulator was 625ns, which is 346ns faster than that of the conventional LDO.

Offset Phase Rotation Shift Keying and Phase Silence Rotation Shift Keying Modulation for Medical In-Body WBAN Systems (의료용 In-Body WBAN 시스템을 위한 Offset Phase Rotation Shift Keying 및 Phase Silence Sotation Shift Keying 변조 방식)

  • Choi, Il-Muk;Won, Kyung-Hoon;Kim, Ki-Yun;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5A
    • /
    • pp.290-297
    • /
    • 2012
  • In this paper, we proposed new modulation schemes, Offset Phase Rotation Shift Keying (OPRSK) and Phase Shift Rotation Shift Keying (PSRSK), for medical in-body wireless body area network (WBAN) systems. In IEEE, the WBAN system is assigned as 802.15. Task Group (TG) 6, and the related standardization is being progressed. Recently, in this Group, Phase Silence Shift Keying (PSSK), Phase Silence Position Keying (PSPK) and Phase Rotation Shift Keying (PRSK), which can obtain higher power efficiency, are proposed as new modulation schemes for low-power operation of WBAN system. However, they have a disadvantage for non-linear amplifier distortion. Therefore, in this paper, we proposed OPRSK and PSRSK, which are robust to non-linear amplification, by employing a phase offset in constellation and a power distribution in symbol duration, and verified that the proposed methods have good perfomance and stable operation through performance evaluation.

Optical Measurement of Blood Oxygen Saturation for Artificial Heart Using Wavelength of 665nm and 805nm (665nm와 805nm의 파장을 이용한 인공심장용 혈중 산소포화도의 광학적 측정)

  • Park, Se-Kwang;Kwon, Ki-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.75-80
    • /
    • 1993
  • This study describes a non-invasive optical sensor and system in order to obtain oxygen saturation of blood, in-vitro. The sensor contains LED 665nm and 805nm of wavelength for light source and PIN photodiode for light detector in flat pack. The sensor system for measurement of oxygen saturation has breadboarded, including signal amplifier, filter, displayer, A/D converter, microprocessor and memory. Experimental set-up for non-invasive measurement of oxygen saturation in-vitro was done. When the variation of oxygen saturation is compared with that of each wavelength, the variation of 665nm is more than that of 805nm by five times. As oxygen saturation varies from 100% to 60%, and the reflection ratio (R805/R665) is changed linearly. The oxygen saturation in $100%{\sim}60%$ range can be measured with about 5% resolution by the developed sensor, such that if this sensor connects with the main artery and vein, the artificial heart can be controlled rapidly and precisely from measurement of the sensor.

  • PDF

A Rotating Balance Design and Performance Estimation for a Rotor Test Jig (로터 실험 장치용 Rotating Balance의 설계 및 성능 검증에 관한 연구)

  • Ryi, Jae-Ha;Rhee, Wook;Choi, Jong-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.301-306
    • /
    • 2009
  • In this study a 3-component rotating balance, which is designed to measure the thrust (Fz) and two moment components (Mx, My) simultaneously for a rotor test jig, is designed and its performance is validated experimentally. The low voltage signal from the strain gages mounted on the balance is amplified with a rotating amplifier, which is then fed through a slip-ring unit into the data acquisition system. In order to validate the accuracy of the calibration matrix obtained from a static calibration test, an additional reaction type balance is used to measure the thrust from a model rotor simultaneously, and shows very good result. Finally, the expanded uncertainty value, which is obtained from ISO method is estimated to be $2.82\times10^{-1}$, and the balance turns out to be reliable.