• 제목/요약/키워드: 중합 광강도

Search Result 164, Processing Time 0.027 seconds

A STUDY ON THE BOND STRENGTHS BETWEEN GLASS IONOMER CEMENT BASES AND COMPOSITE RESINS (글래스 아이오노머 이장재와 복합레진간의 결합강도에 관한 연구)

  • Kim, Min-Hee;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.520-527
    • /
    • 1999
  • For the purpose of providing some suggestions in selection of filling materials used in 'sandwich technique', the bond strengths between glass ionomer cement bases and composite resins were investigated and compared. For lining materials, 'Vitrebond' and 'Ketac-fil' were used. Using these two as bases, 10 of each following resins were built up on the top ; Z-100 (light curing resin) Clear-fil (chemical curing resin), Bis-core (dual cure resin), Dyract (compomer), therfore 10 specimens of each group and total of 80 specimens were made. After storing specimens in $37^{\circ}C$ deionized water for 24 hours, the shear bond strengths were measured under universal testing machine with 50 kg of full load scale and 1mm/min of cross-head speed and obtained the results as follows : 1. Over Vitrebond base, Z-100 showed the lowest bond strength but the other three did not show any difference in bond strength. 2. Over Ketac-fil base, Clear-fil showed the highest bond strength followed by Dyract, Bis-core, and Z-100 showed the lowest bond strengths. 3. Whereas Clear-fil showed the similar bond strengths on the Vitrebond base as other resins, it showed the highest bond strength on Ketac-fil base, which showed some difference in bond strength by differing GIC bases. 4. The bond strengths between base materials and composite resin showed a stronger resin-dependence tendency in cases with Ketac-fil bases rather than with Vitrebond bases.

  • PDF

THE COMPARISON OF RELATIVE RELIABILITY ON BIAXIAL AND THREE POINT FLEXURAL STRENGTH TESTING METHODS OF LIGHT CURING COMPOSITE RESIN (광중합형 레진의 3점 굴곡 강도와 이축 굴곡 강도 측정 방법에 대한 상대적 신뢰도의 비교)

  • Seo, Deog-Gyu;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.58-65
    • /
    • 2006
  • The possibility of applying a hi-axial flexure strength test on composite resin was examined using three point and hi-axial flexure strength tests to measure the strength of the light-cured resin and to compare the relative reliability using the Weibull modulus. The materials used in this study were light-curing restorative materials, $MICRONEW^{TM},\;RENEW^{(R)}$ (Bisco, Schaumburg, USA). The hi-axial flexure strength measurements used the piston-on-3-ball test according to the regulations of the International Organization for Standardization (ISO) 6872 and were divided into 6 groups, where the radius of the specimens were 12mm (radius connecting the 3-balls: 3.75mm), 16 mm(radius connecting the 3-balls: 5mm), and the thickness were 0.5mm, 1mm, 2mn for each radius. The hi-axial flexure strength of the $MICRONEW^{TM}\;and\;RENEW^{(R)}$ were higher than the three point flexure strength and the Weibull modulus value were also higher in all of the bi-axial flexure strength groups, indicating that the hi-axial strength test is relatively less affected by experimental error. In addition, the 2 mm thick specimens had the highest Weibull modulus values in the hi-axial flexure strength test, and the $MICRONEW^{TM}$ group showed no significant statistical difference (p>0.05). Besides the 2mm $MICRONEW^{TM}$ group, each group showed significant statistical differences (p<0.05) according to the thickness of the specimen and the radius connecting the 3-balls. The results indicate that for the 2mm group, the hi-axial flexure strength test is a more reliable testing method than the three point flexure strength test.

THERMAL CHANGE AND MICROHARDNESS IN CURING COMPOSITE RESIN ACCORDING TO VARIOUS CURING LIGHT SYSTEM (광중합기에 따른 복합레진 중합시 온도 변화와 미세경도에 관한 연구)

  • Lee, Dong-Jin;Kim, Dae-Eop;Yang, Yong-Sook;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.391-399
    • /
    • 2004
  • The purpose of this study was to compare curing efficiency of newly developed curing units to traditional halogen curing unit by measuring thermal change and surface microhardness according to curing light system. Materials and mathods : The types of curing units were traditional low intensity halogen light(Optilux 360), plasma arc light(Flipo), low heat plasma arc light(Aurys), low intensity LED(Starlight), and high intensity LED(Freelight2). Temperature at the tip of light guide was measured by a digital thermometer using K-type thermocouple. And after resin was filled to 2, 3, 4mm teflon mold, bottom temperature measured during curing. After 24 hours, microhardness of top surface and bottom surface of each resin specimen were measured. Results : The result of this study can be summarized as follows, 1. As measuring temperature of curing unit tips, Flipo is the highest as $52.4^{\circ}C,\;Freelight2(37.86^{\circ}C),\;Optilux360(32.68^{\circ}C),\;Aurys(32.34^{\circ}C),\;and\;Starlight(26.14^{\circ}C)$ were followed. 2. Flipo and Freelight2 were the highest similarly and Optilux360 and Aurys were similarly next and Starlight was lowest in temperature of bottom surface of resin mold. 3. Microhardness of top surface were generally similar, and Aurys was relatively low. 4. Optilux 360 and Freelight2 were the highest, and Flipo, Starlight, and Aurys were followed in microhardness of bottom surface. Conclusions : The results suggest that careful use of Flipo and Freelight2 might be able to cure greater depth of resin composite and do not cause thermal problems than other curing units.

  • PDF

THE COMPARATIVE STUDY FOR THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES CURED WITH VARIOUS LIGHT SOURCES (다양한 광원으로 중합한 치과용 접착제의 전단강도에 관한 비교 연구)

  • Choi, Nam-Ki;Cho, Seong-Hoon;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • The objective of this study was to compare the shear bond strengths of five dentin adhesive systems cured with three different light curing sources. Seventy five noncarious permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), G-Bond (GB). And three light curing unit systems were used: Elipar Free light 2(LED), OptiLux 501 (Halogen), Flipo (PAC). For the shear bonding test, the labial and lingual surfaces of permanent teeth were used. To obtain a flat dentin surface, the labial and lingual surfaces of the teeth were sanded on SiO2 with number 600 grit and then divided into 15 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. When cured with Freelight 2, the shear bond strength of SM was significantly higher than that of PL, GB (p<0.05), whereas no significant difference was found among those of any other bonding agents. 2. When cured with Optilux 501, the shear bond strength of SM was significantly higher than those of any other bonding agents (p<0.05), whereas no singnificant difference was found among those of andy other bonding agents. 3. When cured with Flipo, the shear bond strength of SM was significantly higher than those of SB, SE, GB (p<0.05), whereas no significant differences was found among those of any other bonding agents. 4. For comparison according to three different light cure unit system, except SB and GB, each three dentin bonding agents showed no significant difference. For SB, only Freelight 2 was significantly higher than the others, with no significant difference between Optilux 501 and Flip. For GB, Statistically significant difference was found only between Freelight and Flipo.

Investigation of the Shear Bond Strength of Orthodontic Buttons by Light Curing Using an Extended Optic Fiber (광섬유를 이용한 광중합에 따른 교정용 버튼의 전단결합강도에 관한 연구)

  • Yoon, Garam;Lee, Nanyoung;Lee, Sangho;Jih, Myeongkwan;Choi, Wonseok;Sung, Minah
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.105-114
    • /
    • 2021
  • The objective of this study is to analyze the shear bond strength of orthodontic buttons according to light tip distance and optic fiber diameter when an extended optic fiber was applied to the tip of a curing light unit. In this study, 315 extracted premolar teeth were divided into 3 groups. Orthodontic buttons were attached using no optic fibers (Group I), 3.0 mm diameter optic fibers (Group II), or 5.0 mm diameter optic fibers (Group III). Each group was divided into subgroups A - C (5.0, 10.0, and 15.0 mm light tip distance), respectively. Shear bond strength was then measured while varying the light tip distance. In group I, shear bond strength significantly decreased as the light tip distance increased. When the shear bond strength was evaluated according to the optic fiber diameter, no statistical significance was observed in group of 5.0 mm light tip distance. Compared with group IB, group IIIB showed significantly greater shear bond strength. Compared with group IC, all groups using 3.0 or 5.0 mm diameter optic fibers showed significantly greater shear bond strength. Therefore, when a curing light unit has poor accessibility, optic fibers with a large diameter should be considered.

Microhardness and microleakage of composite resin according to the change of curing light intensity (다양한 중합광도에 따른 복합레진의 미세 경도와 변연 누출도)

  • Soo-man Park;Dong-Hoon Shin
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.363-371
    • /
    • 2001
  • 심미성 수복재 중합시 사용되는 광원은 다양한 요인들에 의해 선택되어지고 있지만 이러한 요인들은 앞으로도 논란의 여지를 많이 남겨두고 있다. 또한 현재 사용되고 있는 중합법들이 제각기 독특한 장점들을 갖고 있기 때문에 최적의 중합법 결정이 필요한 시점이다. 이에 본 연구에서는 중합광의 강도(50, 100, 200, 300, 400, 600mW/$\textrm{cm}^2$)와 중합시간(10, 20, 40초)을 다양하게 변화시켰을 때 복합레진의 미세경도와 미세누출도가 어떠한 양태를 보이는지를 관찰하고자 하였다. 본 실험에서는 A3 색상의 혼합형 복합레진인 국산 DenFil과 미세입자형 복합레진인 Esthet X를 사용하였다. 중합 1일 후 복합레진의 Vickers 경도는 다이아몬드형 압흔 길이를 측정하여 평가하였으며 미세누출도는 1% methylene blue용액을 이용한 방법과 주사전자 현미경을 이용한 수복물과 치질간의 최대 이개도 평가법의 두 가지 방법으로 측정하였다. 본 연구의 결과는 다음과 같다; 1. 미세경도는 시편 상면이 하면에 비해 단단한 양태를 보였으며 상, 하면에 관계없이 혼합형 복합레진인 국산 DenFil이 미세입자형 복합레진인 Esthetx에 비해 높은 경도치를 보였다. 2. 모든 미세 경도 실험에서 너무 낮은 광도(50mW/$\textrm{cm}^2$, 100mW/$\textrm{cm}^2$)로 중합한 군에서는 대조군에 비해 유의하게 낮은 미세 경도를 보였다(p<0.05). 3. 상면의 경우, DenFil은 중합시간과 관계없이 200mW/$\textrm{cm}^2$ 이상의 광도에서 대조군(600mW/$\textrm{cm}^2$ 광도로 40초간 중합)과 유의차 없는 미세경도치를 보였으나, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 4. 하면의 경우 DenFil은 300mW/$\textrm{cm}^2$ 이상의 광도로, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 각기 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 5. 법랑질 변연부에서는 색소 침투가 전혀 없었으나 상아질 변연부에서는 정도의 차이는 있었지만 모든 시편에서 색소 침투를 보였다. 6. 통계적 유의차는 없었지만 저광도에서 우수한 미세누출도를 보였으며 색소 침투법과 최대 이개도 평가법간에는 상관성이 매우 낮았다 (p=0.801).

  • PDF

EFFECT OF INCREASING APPLICATION TIME OF SINGLE BOTTLE ADHESIVES TO MICROTENSILE BOND STRENGTH OF DRIED DENTIN (수종의 단일병 접착제의 적용 시간 연장이 건조 상아질의 미세인장 결합강도에 미치는 영향)

  • Kim, Hak-Geun;Kim, Dong-Jun;Hwang, Yun-Chan;Oh, Won-mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.435-441
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of increasing application time of single bottle adhesives (SBA) to microtensile bond strength (MTBS) of dried dentin. To expose the superficial dentin surfaces, human molars were sectioned perpendicular to the long axis of tooth. $32\%$ phosphoric acid gels were applied for 15s and rinsed. The teeth were randomly assigned to 3 groups ; S group (Single Bond), O group (One-Step), P group (Prime & Bond NT). Each group was divided to 3 subgroups (W: dentin wipe with wet gauge and light cured immediately, D, dentin dried for 30s and light cured immediately, 30: dentin dried for 30s and light cured after applying SBA for 30s). Composite resin was built up on the dentin surface and sectioned to obtain 20 specimens with $1mm^2$ cross sectional area and the MTBS was measured. For Single Bond, the mean MTBS of S-W and S-30 group were higher than that of S-D group statistically (P<0.05). For One-Step, the mean MTBS of O-D group was statistically lower than that of O-W group (P<0.05). For Prime & Bond NT, the mean MTBS of P-30 group was statistically lower than that of P-D group (P<0.05).

A STUDY ON THE EVALUATION OF POLYMERIZATION SHRINKAGE OF COMPOSITE AND COMPOMER USING STRAIN GAUGE METHOD (스트레인 게이지법을 이용한 복합레진과 컴포머의 중합수축 평가에 관한 연구)

  • Kim, Yeun-Chul;Kim, Jong-Soo;Kwon, Soon-Won;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.19-29
    • /
    • 2002
  • The purpose of this study was to compare the polymerization shrinkage and the compressive strength of composite and compomer cured with two different light sources ; conventional halogen-light curing unit and recently-developed plasma arc curing unit. The 'strain gauge method' was used for determination of polymerization shrinkage and the compressive strength was measured by universal testing machine. The results of the present study can be summarized as follows: 1. Filling materials in polyethylene molds showed the initial expansion in the early phase of polymerization. This was followed by the rapid contraction in volume during the first 60 seconds and gradually diminished as curing process continued. 2. The polymerization shrinkage in tooth samples was generally lower than in the mold samples. 3. The generally lower amount of linear polymerization shrinkage was observed in compomer and plasma arc curing unit group when compared to composite and conventional curing unit. 4. The higher compressive strength values was found in composite groups regardless curing methods. The results of this study strongly support the application of plasma arc system and fluoride-containing compomer in the field of clinical pediatric dentistry claiming its effectiveness in curing the esthetic dental materials and the anticariogenic capacity.

  • PDF

APPLICATION OF ACIDIC PRIMER FOR ORTHODONTIC ADHESIVE SYSTEM (Acidic primer를 이용한 교정용 브라켓 접착의 전단결합강도)

  • Kim, Jin-Hee;Jin, Hun-Hee;Oh, Jang-Kyun
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.137-147
    • /
    • 2001
  • Acidic primer is the bonding agent which combines the conditioning and priming agent into the single solution and was originally developed for the dentin bonding system. It is less harmful to the tooth structure and more convenient to manipulate than the traditional etching procedure. The Purpose of this study is to evaluate the shear bond strength of various bonding materials when the enamel is treated with acidic primer for the bracket bonding procedure. Fifty recently extracted human premolars were randomly separated into five groups -Group I using Clearfil Liner Bond 2 adhesive system to the enamel treated with acidic primer, Group II using Transbond XT adhesive system to the enamel treated with acidic primer, Group III using panavia 21 adhesive system to the enamel treated with acidic primer, Group IV using Fuji-Ortho LC adhesive system to the enamel treated with acidic primer, Group V using Transbond XT adhesive system to the enamel treated with 37$\%$ phosphoric acid. The shear bond strength was measured with Instron universal testing machine after storing in $37^{\circ}C$ water bath for 48 hours. After debonding, the teeth and brackets were examined under scanning electron microscope (SEM) and assessed with the adhesive remnant index (ARI). The results were as follows : 1. There were no significant differences in shear bond strength between group III ($8.69{\pm}2.72MPa$), group IV (9.7 ± 3.16 MPa), and group V ($10.48{\pm}2.60MPa$) (p>0.05). 2. The shear bond strength of group III and group IV was significantly higher than that of group I ($1.09{\pm}0.53MPa$), and Group II ($2.70{\pm}1.46MPa$) (p<0.05). 3. The ARI of group IV ($2.1{\pm}1.1$) and group V ($2.9{\pm}0.3$) was significantly higher than that of group I ($0.2{\pm}0.4$), group II ($0.3{\pm}0.9$) and group III ($0.2{\pm}0.4$) (p<0.05). 4. There were no significant difference between the ARI of group IV and group V (p>0.05). This result suggests that the combination of acidic primer and some bonding adhesive can provide sufficient shear bond strength for clinical orthodontics.

  • PDF