A STUDY ON THE EVALUATION OF POLYMERIZATION SHRINKAGE OF COMPOSITE AND COMPOMER USING STRAIN GAUGE METHOD

스트레인 게이지법을 이용한 복합레진과 컴포머의 중합수축 평가에 관한 연구

  • Kim, Yeun-Chul (Department of Pediatric Dentistry, Graduate School of Dentistry, Dankook University) ;
  • Kim, Jong-Soo (Department of Pediatric Dentistry, Graduate School of Dentistry, Dankook University) ;
  • Kwon, Soon-Won (Department of Pediatric Dentistry, Graduate School of Dentistry, Dankook University) ;
  • Kim, Yong-Kee (Department of Pediatric Dentistry, Graduate School of Dentistry, Dankook University)
  • 김윤철 (단국대학교 치과대학 소아치과학교실) ;
  • 김종수 (단국대학교 치과대학 소아치과학교실) ;
  • 권순원 (단국대학교 치과대학 소아치과학교실) ;
  • 김용기 (단국대학교 치과대학 소아치과학교실)
  • Published : 2002.02.28

Abstract

The purpose of this study was to compare the polymerization shrinkage and the compressive strength of composite and compomer cured with two different light sources ; conventional halogen-light curing unit and recently-developed plasma arc curing unit. The 'strain gauge method' was used for determination of polymerization shrinkage and the compressive strength was measured by universal testing machine. The results of the present study can be summarized as follows: 1. Filling materials in polyethylene molds showed the initial expansion in the early phase of polymerization. This was followed by the rapid contraction in volume during the first 60 seconds and gradually diminished as curing process continued. 2. The polymerization shrinkage in tooth samples was generally lower than in the mold samples. 3. The generally lower amount of linear polymerization shrinkage was observed in compomer and plasma arc curing unit group when compared to composite and conventional curing unit. 4. The higher compressive strength values was found in composite groups regardless curing methods. The results of this study strongly support the application of plasma arc system and fluoride-containing compomer in the field of clinical pediatric dentistry claiming its effectiveness in curing the esthetic dental materials and the anticariogenic capacity.

본 연구의 목적은 다양한 중합과정에 따른 복합레진과 컴포머의 수축 양상을 스트레인 게이지법(strain gauge method)을 이용하여 평가해보고자 하는 것이었다. 광중합기는 기존의 할로겐 시스템인 XL 3000(3M, USA)과 최근 소개된 plasma arc curing 시스템인 Flipo(LOKKI, France)를 사용하였고, 충전 재료는 복합레진인 Z-100(3M, USA)과 컴포머인 Dyract AP(Dentsply, Germany)를 사용하였다. 주형과 치아 와동 내에 충전된 실험재료의 중합수축을 각각 측정하였으며, 만능시험기를 이용하여 압축강도를 측정하였다. 중합수축 측정 결과 모두 중합초기에는 일시적인 재료의 팽창을 나타냈고, 그 후 약 1분간은 수축량이 급격히 증가하다가 증가의 폭이 점차 감소하는 양상을 보였다. 전반적으로 컴포머를 사용한 군에 비해 복합레진을 사용한 군에서 중합수축이 크게 나타났으며 plasma arc curing 시스템을 사용한 군에 비해 기존의 광조사 시스템 군에서 더 큰 중합수축을 보였다. 압축 강도의 측정결과는 컴포머 군에 비해 복합레진 군에서 크게 나타났다. 이상의 결과를 종합해 볼 때, plasma arc curing unit와 컴포머의 사용은 시술시간의 단축과 항우식 효과를 감안한다면 소아치과 영역에서의 사용이 긍정적으로 고려될 수 있다고 생각된다.