• Title/Summary/Keyword: 중선

Search Result 334, Processing Time 0.026 seconds

A Study on Impact Control of Planar Redundant Manipulator using A Intelligent Control (지능제어를 이용한 평면 여자유도 매니퓰레이터의 충돌제어에 관한 연구)

  • Yoo, Bong-Soo;Koo, Seong-Wan;Joh, Joong-Seon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.6
    • /
    • pp.787-796
    • /
    • 2008
  • When the manipulator collides with surroundings, there occurs an impulse. To reduce the impulse, the self motion should maintain the manipulator's position by the minimally effective mass. At this time, we can use the local joint torque minimization algorithm to resolve the redundancy. In this study, to reduce the impulse and damages by the impact between the manipulator and surroundings, new control algorithm for the minimization of the joint torque using the kinetic redundancy and the impact minimization is proposed. It adapts fuzzy logic and genetic algorithm to the conventional local joint torque minimization algorithm. The proposed algorithm is applied to a 3-DOF redundant planar manipulator. Simulation results show that the proposed algorithm works well.

Manufacturing of the Linear Induction EM Pump for the Liquid Sodium (액체소듐 구동용 선형유동전자펌프 제작)

  • 김희령;남호윤;황중선
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.434-437
    • /
    • 1999
  • An EM pump is used for the purpose of transporting the electrically conducting liquid sodium of the high temperature that is used as a coolant in the liquid metal reactor. In the present study, the pilot pump has been designed and manufactured for the high temperature of $600^{\circ}C$ by the equivalent circuit materials and the consideration of the materials and functions. The length and diameter of the pump are given as 84 cm and 10 cm each due to the fixed geometry of the circulation system to be installed. The characteristic of the developing pressure and efficiency is found out by using Laithewaite\`s standard design formula. It is shown that the developing pressure and efficiency are maximized at the frequency of 15 Hz from the curve. The annular channel gap of 3.95 mm is selected in the range of the reasonable hydraulic frictional loss. The components of the pump consist of the material for the high temperature. And then, the pump is manufactured to have the nominal flowrate of 40 1/min and developing Pressure of 1.3 bar.

  • PDF

A Study on Mossbauer Spectrum of the $NiAl_0.8Fe_1.2O_4$ ($NiAl_0.8Fe_1.2O_4$의 Mossbauer' Spectrum연구)

  • Lee, Cheol-Sae
    • The Journal of Natural Sciences
    • /
    • v.7
    • /
    • pp.19-25
    • /
    • 1995
  • In this study, the Mossbauer effect of the $NiAl_0.8Fe_1.2O_4$ was investigated in the temperature range of 77K-1000K. The spectra were composed of two component, one is sixtet and the other doublet, at low temperature. From the temperature dependence of Mossbauer spectum, it is appeared that the magnetic properties of $NiAl_0.8Fe_1.2O_4$ varies from ferrimagnetism to paramagnetism as the increasing tempereture. And the magnetic relaxation patterns of the $NiAl_0.8Fe_1.2O_4$ were shown superparamagnetic effect.

  • PDF

Clinical Applications of Intracoronary OCT (Invited Paper) (심혈관 OCT의 임상적 응용)

  • Ha, Jinyong;Kim, Jung-Sun;Hong, Myeong-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • The most common cause of a heart attack is known as coronary artery disease, which narrows the arteries and reduces the blood flow to the heart. To treat coronary artery stenosis, percutaneous coronary intervention (PCI) (a nonsurgical procedure to install a stent, which holds the artery wall open) is performed. Intracoronary optical coherence tomography (OCT) is a catheter-based, invasive optical imaging system. To determine whether PCI is appropriate, and to perform stent evaluation in a catheterization laboratory, OCT examinations are carried out. This review details the fundamental principles and technological status of intracoronary OCT imaging, and discusses the ongoing clinical applications to determine the benefits of OCT-guided PCI.

Studies on Licorice in Drug Preparations(I) Determination of Glycyrrhizin and Glycyrrhetinic acid by HPLC. (생약중의 감초에 관한 연구(I) HPLC에 의한 Glycyrrhizin 및 Glycyrrhetinic acid의 정량)

  • 백남호;박만기;박정일;김중선;서정진
    • YAKHAK HOEJI
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 1981
  • Glycyrrhizin (GA) content in licorice was determined by a couple of methods using HPLC, respectively. In Method(I), GA content itself was determined from the licorice aqueous extract, while in Method (II) glycyrrhetinic acid (GHeA ; the aglicone of GA) content corresponding to the quantity of GA was measured from the chloroform extract of the hydrolyzed product of licorice aqueous extract. A reverse phase column Hibar Lichrosorb RP-18 (E. Merck) was used as the stationary phase. As the mobile phase MeOH: $H_{2}O$(0.05M-$NaH_{2}PO_{4}$)=58 : 42 solution in Method (I), and MeOH: $H_{2}O $: AcOH=78; 19: 3 solution in Method (II) were suitable, respectively. The value obtained by Method (II) appeared slightly higher than that by Method (I). The effect of some other herbal drugs on the assay of GA quantity in mixed sample was also observed in both above two methods. By Method (I) Cassiae Cortex, Rehmaniae Rhizoma, Paeoniae Radix, and Angelicae Radix gave the subtractive effect on the amount of GA compared with the value from licorice alone. In the case of Method (II) Cassiae Cortex and Rehmaniae Rhizoma appeared to have subtractive effect but Paeoniae Radix and Angelicae Radix scarcely showed any influence. Pachymae Fungus did not affect the GA content at all. It seems that glycyrrhizin in licorice interacts with certain components of other herbal drugs.

  • PDF

A Brain-Computer Interface Based Human-Robot Interaction Platform (Brain-Computer Interface 기반 인간-로봇상호작용 플랫폼)

  • Yoon, Joongsun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7508-7512
    • /
    • 2015
  • We propose a brain-machine interface(BMI) based human-robot interaction(HRI) platform which operates machines by interfacing intentions by capturing brain waves. Platform consists of capture, processing/mapping, and action parts. A noninvasive brain wave sensor, PC, and robot-avatar/LED/motor are selected as capture, processing/mapping, and action part(s), respectively. Various investigations to ensure the relations between intentions and brainwave sensing have been explored. Case studies-an interactive game, on-off controls of LED(s), and motor control(s) are presented to show the design and implementation process of new BMI based HRI platform.

The Comparison Between Blind and Normal Children in Standing Position (시각장애 아동과 정상 아동의 선자세 균형 비교)

  • Kim Chung-sun;Lee Jeong-soon
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.119-154
    • /
    • 2003
  • In this paper, the proprioceptive sensitivity was compared by Foot-Hand task method and the effect of the proprioceptive sensitivity and auditory to the standing position between blind and normal children was measured using BPM for 56 children in 7, 8, 9 and 10 years old. There are three measurement methods are used for BPM : Rest, Forward Looking, 'Sound' position. The following conclusions were obtained from the above measurements. 1. In comparison of proprioceptive sensitivity between blind and normal children, there is no significant difference(p > .05). There is no significant difference in comparison of each age group and also there is no difference in each gender group(p > .05). 2. In comparison of standing position measurement between blind and normal children, there is any difference (p > .05) in three measurement(Rest, Forward Looking, 'Sound' position) but there is no significant difference in each gender difference(p > .05). There is any difference between Rest and 'Sound' position of blind children, also there is any difference between Forward Looking and ' Sound ' position, rest and 'Sound' position of normal children(p > .05). 3. There is no significant difference of correlation between proprioceptive sensitivity test and standing position measurement in Pearson correlation coefficient(p > .05).

  • PDF

The Effects of Wrist Supporter and Kinesio Taping on Grip Strength (손목보호대와 카네시오 테이핑 적용이 파악력에 미치는 영향)

  • Yeo, Sang-Seok;Kang, Jong-Ho;Kwon, Yong-Hyun;Kim, Chung-Sun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.3 no.3
    • /
    • pp.161-167
    • /
    • 2008
  • Purpose : The purpose of this study was to evaluate the effect of kinesio taping and wrist supporter on grip strength. Methods : The subjects for this study were thirty three young healthy people. To find out the effectiveness of kinesio taping and wrist supporter, divide three treatment method. Subjects measure the normal grip strength and then put on the kinesio taping and wrist supporter on wrist. Results : The results were as follow : 1. There were statistical significance on the grip strength with taping group(p<0.05). 2. There were statistical significance on the grip strength with wrist supporter group(p<0.05). 3. Taping group was more statistical significance than wrist supporter group on the grip strength. Conclusion : Supporter and taping on wrist were effective in grip strength.

  • PDF

Studies on the Preservation of Raw Beef by Gamma Radiation (감마선 조사에 의한 우육의 저장에 관한 연구)

  • Kim, Yun-Jin;Park, Yong-Kun;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.95-99
    • /
    • 1972
  • Studies were made to investigate the influence of vacuum packing after irradiating mean doses of gamma ray at freezing temperature $(-20^{\circ}C)$ on the keeping quality and color of raw beef. Fresh round steaks were packaged anaerobically in aluminum foil, and irradiated with 0.25 and 0.5 Mrad followed by storage at $5^{\circ}C$. The shelf life of beef irradiated with 0.5 Mrad could be extended about 10 days longer than unirradiated, and the off-odors was not developed. The discoloration by irradiation was shown, but soon reverted to about 90 percentage myoglobin in 20 hours.

  • PDF

A Stabilization of MC-BCS-SPL Scheme for Distributed Compressed Video Sensing (분산 압축 비디오 센싱을 위한 MC-BCS-SPL 기법의 안정화 알고리즘)

  • Ryu, Joong-seon;Kim, Jin-soo
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.5
    • /
    • pp.731-739
    • /
    • 2017
  • Distributed compressed video sensing (DCVS) is a framework that integrates both compressed sensing and distributed video coding characteristics to achieve a low complexity video sampling. In DCVS schemes, motion estimation & motion compensation is employed at the decoder side, similarly to distributed video coding (DVC), for a low-complex encoder. However, since a simple BCS-SPL algorithm is applied to a residual arising from motion estimation and compensation in conventional MC-BCS-SPL (motion compensated block compressed sensing with smoothed projected Landweber) scheme, the reconstructed visual qualities are severly degraded in Wyner-Ziv (WZ) frames. Furthermore, the scheme takes lots of iteration to reconstruct WZ frames. In this paper, the conventional MC-BCS-SPL algorithm is improved to be operated in more effective way in WZ frames. That is, first, the proposed algorithm calculates a correlation coefficient between two reference key frames and, then, by selecting adaptively the reference frame, the residual reconstruction in pixel domain is performed to the conventional BCS-SPL scheme. Experimental results show that the proposed algorithm achieves significantly better visual qualities than conventional MC-BCS-SPL algorithm, while resulting in the significant reduction of the decoding time.