• Title/Summary/Keyword: 주기분포

Search Result 1,010, Processing Time 0.033 seconds

The Cross-sectional Mass Flux Observation at Yeomha Channel, Gyeonggi Bay at Spring Tide During Dry and Flood Season (단면 관측을 통한 경기만 염하수로의 대조기 평수시와 홍수시 유출입량 변화특성 조사)

  • Lee, Dong-Hwan;Yoon, Byung-Il;Kim, Jong-Wook;Gu, Bon-Ho;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.16-25
    • /
    • 2012
  • To calculate the total mass flux that change in dry and flood season in the Yeomha Channel of Gyeonggi Bay, the 13 hour bottom tracking observation was performed from the southern extremity. The value of the total mass flux(Lagrange flux) was calculated as the sum of the Eulerian flux value and stroke drift value and the tidal residual flow was harmonically analyzed through the least-squares method. Moreover, the average during the tidal cycle is essential to calculate the mass flux and the tidal residual flow and there is the need to equate the grid of repeatedly observed data. Nevertheless, due to the great differences in the studied region, the number of vertical grid tends to change according to time and since the horizontal grid differs according to the transport speed of the ship as a characteristic of the bottom tracking observation, differences occur in the horizontal and vertical grid for each hour. Hence, the present study has vertically and horizontally normalized(sigma coordinate) to equate the grid per each hour. When compared to the z-level coordinate system, the Sigma coordinate system was evaluated to have no irrationalities in data analysis with 5% of error. As a result of the analysis, the tidal residual flow displayed the flow pattern of sagging in the both ends in the main waterway direction of dry season. During flood season, it was confirmed that the tidal residual flow was vertical 2-layer flow. As a result of the total mass flux, the ebb properties of 359 cm/s and 261 cm/s were observed during dry and flood season, respectively. The total mass flux was moving the intertidal region between Youngjong-do and Ganghwa-do.

A Study on Recent Research Trend in New Product Development Using Keyword Network Analysis (키워드 네트워크 분석을 이용한 NPD 연구의 진화 및 연구동향)

  • Pyun, JeBum;Jeong, EuiBeom
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.5
    • /
    • pp.119-134
    • /
    • 2018
  • Today, many firms face the environment of high uncertainty and severe competition due to the rapid technology development and the diverse needs of customers. In the business environment, one of the most important ways to gain sustainable competitive advantage and future growth engine is related to NPD (New Product Development), which is a very important issue for practice and academia. Thus, this study intends to provide new values to practitioners and researchers related to NPD by analyzing current research trends and future trends in NPD field. For this, we bibliometrically analyzed keyword networks which consist of keywords that were already published in the eminent journals from Scopus database to generate insights that have not been captured in the previous reviews on the topic. As a result, we could understand the extant research streams in NPD field, and suggest the changes of specific research topics based on the connected relationships among keywords over the time. In addition, we also foresaw the general future research trends in NPD field based on the keywords according to preferential attachment processes. Through this study, it was confirmed that NPD keyword network is a small world network that follows the distribution of power law and the growth of network is formed by link formation by keyword preferential attachment. In addition, through component analysis and centrality analysis, keywords such as Innovation, New product innovation, Risk management, Concurrent engineering, Research and development, and Product life cycle management are highly centralized in NPD keyword network. On the other hand, as a result of examining the change of preferential attachment of keywords over the time, we suggested the required new research direction including i) NPD collaboration with suppliers, ii) NPD considering market uncertainty, iii) NPD considering convergence with the other academic areas like technology management and knowledge management, iv) NPD from SME(Small and medium enterprises) perspective. The results of this study can be used to determine the research trends of NPD and the new research themes for interdisciplinary studies with other disciplines.

A Study on Sea Water and Ocean Current in the Sea Adjacent to Korea Peninsula -The Vertical Structure of Temperatures in the East Sea of Korea- (한반도 근해의 해류 및 해수특성 -한국 동해의 수온의 수직구조-)

  • NA Jung-Yul;LEE Seong-Wook;CHO Kyu-Dae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.24 no.4
    • /
    • pp.215-228
    • /
    • 1991
  • In the East Sea of Korea the vertical structure functions of the temperature field were evaluated and the characteristic thermal zone was classified by the use of the empirical orthogonal function(EOF) method. The East Sea of Korea within the hydrographic lines of 10-107 of the Fisheries Research and Development Agency of Korea(FRDA) can be divided into three thermal regions by the characteristics of the vertical temperature variability. They are the North Korean Cold Current(NKCC) region near the coast which extends parallel to the north-south direction, the Warm-Core(WC) region which dominates almost all the hydrographic stations of the Line 104 of the FRDA and occupies a few stations of the Line-103 and -105 with its axis at the Line 104, and the East Korea Warm Current(EKWC) region which is bisected into the northern and the southern part by the WC region, respectively. Considering the two most important modes, $85.20-98.20\%$ of the total variance of temperature variation are explained in the NKCC region, $85.20-92.90\%$ in the EKWC region, and$85.50-91.70\%$ in the WC region. The first mode has its peak value at the surface with the annual cycle of variation. The spatial pattern of the first mode portrays a coherent vertical variation in the EKWC region and a clear anti-correlation both in the NKCC region and in the WC region where the zero-crossing depths are loom and 200m, respectively. The second mode of the NKCC region is particularly noticeable, haying its peak at loom with coherent vertical variation. To study the time dependency of the vertical structure functions, the extended EOF(EEOF) method was used. The persistence of the first mode is less than 4 months in the study area. The annual variation of the first mode in the NKCC region is different from those in the WC region and in the EKWC region.

  • PDF

Effect of Noise in Human Body (소음이 인체에 미치는 영향)

  • 이영노
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.7-8
    • /
    • 1972
  • The effects of noise exposure are of two types: Nonauditory effects and auditory effects. Nonauditory effects of noise exposure are interference with communication by speech, sleeping and emotional behavior. The noise will cause the high blood pressure and rapid pulse, also that decrease the salivation and gastric juice. in experimentaly showed that the Corticoid hormon: Gonatotropic hormone were decrease and Thyrotropic hormoone is increase. Auditory effect of noise exposure. when the normal ear is exposed to noise at noise at hamful intensities (above 90㏈) for sufficiently long periods of time, a temoral depression of hearing results, disappearing after minutes or hours of rest. When the exposure longer or intesity greater is reached the Permanent threshold shift called noise-induced hearing loss. Hearing loss resulting from noise exposure presents legal as well as medical problems. The otologist who examines and evaluates the industrial hearing loss cases must be properly informed, not only concerning the otologic but also about the physical and legal aspects of the problems. The measurement of hearing ability is the most important part of a hearing conservation, both preplacement and periodic follow-up tests of hearing. The ideal hearing conservation program would be able to reduce or eliminate the hazardous noise at its source or by acoustic isolation of noisy working area and two ear protections (plugs and muff type) were developed for personal protection.

  • PDF

A Clinical Therapeutic Results on Small Cell Lung Cancer (소세포 폐암의 치료성적에 대한 고찰)

  • Kim, Eun-Hwa;Lee, Soon-Hyoung;Huh, Won-Young;Kim, Han-Sik;Jo, Jin-Ung;Kim, Mee-Ae;Kim, Sang-Kyun;Kim, Kwi-Wan;Chung, Weon-Kuu;Kim, Soo-Kon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.3
    • /
    • pp.262-269
    • /
    • 1994
  • Background : A clinical study was carried out on 153 new cases with small cell lung cancer registered at Presbyterian Medical Center, Chonju during the 7 years from 1986 to 1992. They were analyzed by sex and age distribution, symptoms and signs, classification of stage and site and its treatments. Especially, an effort was made to compare the overall survival time between limited stage and extensive stage. Methods : Among 806 lung cancer patients diagnosed by biopsy or cytologic evaluation for the 7 years, 153 patients was shown small cell lung cancer. These 153 cases was analyzed retrospectivery through patient's records, letters or telephones. Results : The results of evaluation of small cell lung cancer are as follows. Over 85 percent of the small cell lung cancer patients were over 50 years of age and prominent clinical features were cough(86.3%), sputum(75.8%) and dyspnea(54.9%). One hundred and five patients(68.7%) was staged to have limited stage. Mean survival time of the chemotherapy and chemoradiotherapy in limited stage has significant difference and its survivals are 5.3 months and 15.0 months. Patients whose disease was staged as limited, regardless of whether or not chemotherapy was administered, had a median survival time of 10.9 months, compared with 4.8 months for those with extensive stage. Conclusion : Lung cancer is one of the malignant diseases tend to increase gradually in Korea and proven to be the most common cancer next to the gastric cancer among various cancers in males found at the Presbyterian Medical Center in the past seven years. This report is a retrospective view of the clinical therapeutic results of the small cell lung cancer patients. Especially at the limited stage, the combined therapy revealed higher survival rate than the chemotherapy alone. For a more accurate evaluation. a prospective view, without any bias, of patients selected at random is needed.

  • PDF

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times (호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Woong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • The gated RapidArc may produce a dosimetric error due to the stop-and-go motion of heavy gantry which can misalign the gantry restart position and reduce the accuracy of important factors in RapidArc delivery such as MLC movement and gantry speed. In this study, the effect of stop-and-go motion in gated RapidArc was analyzed with varying gating window time, which determines the total number of stop-and-go motions. Total 10 RapidArc plans for treatment of liver cancer were prepared. The RPM gating system and the moving phantom were used to set up the accurate gating window time. Two different delivery quality assurance (DQA) plans were created for each RapidArc plan. One is the portal dosimetry plan and the other is MapCHECK2 plan. The respiratory cycle was set to 4 sec and DQA plans were delivered with three different gating conditions: no gating, 1-sec gating window, and 2-sec gating window. The error between calculated dose and measured dose was evaluated based on the pass rate calculated using the gamma evaluation method with 3%/3 mm criteria. The average pass rates in the portal dosimetry plans were $98.72{\pm}0.82%$, $94.91{\pm}1.64%$, and $98.23{\pm}0.97%$ for no gating, 1-sec gating, and 2-sec gating, respectively. The average pass rates in MapCHECK2 plans were $97.80{\pm}0.91%$, $95.38{\pm}1.31%$, and $97.50{\pm}0.96%$ for no gating, 1-sec gating, and 2-sec gating, respectively. We verified that the dosimetric accuracy of gated RapidArc increases as gating window time increases and efforts should be made to increase gating window time during the RapidArc treatment process.

Report on the External Audits Conducted by Korean Society of Medical Physics (한국의학물리학회 선형가속기 외부 품질관리 실시 현황보고)

  • Huh, Hyun Do;Cho, Kwang Hwan;Cho, Sam Ju;Choi, Sang Hyoun;Kim, Dong Wook;Hwang, Ui-Jung;Kim, Ki Hwan;Min, Chul Kee;Choi, Tae Jin;Oh, Young Kee;Lee, Seoung Jun;Park, Dahl;Park, Sung-Kwang;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.315-322
    • /
    • 2013
  • The aim of this work is to verify the self-quality assurances in medical institutions in Korea through the external audits by the group of experts and have a mutual discussion of the systematic problems. In order to validate the external audits 30 of 80 medical institutions across the nation were picked out considering the regional distribution and the final 25 institutions applied voluntarily to take part in this work. The basic rules were setup that any information of the participants be kept secrete and the measurements be performed with the dosimetry system already verified through intercomparision. The outputs for 2 or more photon beams, the accuracy of gantry rotation and collimator rotation and the poistional accuracy of MLC movement were measured. The findings for the output measurement showed the differences of -0.8%~4.5%, -0.79%~3.01%, and -0.7%~0.07% with respect to that of the verified dosimetry system for the 6MV, 10MV, and 15MV, respectively. For the reference absorbed dose 8 (16%) of 50 photon beams in 25 medical institutions differed 2.0% or greater from the reference value. The coincidences of Field size with x-ray beam and radiation isocenters of Gantry roration and collimator rotation gave the results of within ${\pm}2$ mm for every institute except 2 institutions. The positional accuracy of MLC movement agreed to within ${\pm}1$ mm for every institute. For the beam qualities of 6 MV photon beams kQ values showed the distribution within 0.4% between maximum and minimum. For the protocols 21 institutions (84%) used absorbed dose to water based protocol while 4 insitutions (16%) used air kerma based one. 22 institutions employed the SSD technique while 3 institutions did the SAD one. External audit plays an important role in discovering the systematic problems of self-performing Quality Assurances and having in depth discussion for mutual complementation. Training experts of international level as well as national support system are required so that both the group of experts of medical physicists and government laboratory could perform together periodical and constant external audits.

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

The Studies on In Vivo Embryo Production using Sex-Sorted Sperm in Korean Brindle Cattle (성 감별 정자를 이용한 칡소 체내수정란 생산에 관한 연구)

  • Jeon, Hyang-A;Moon, Seung-Ju;Lee, Ji-Woong;Kang, Man-Jong;Sohn, Sea-Hwan;Kim, Nam-Tae;Ko, Yeoung-Gyu;Kim, Sung-Woo;Kim, Dong-Kyo;Seong, Hwan-Hoo;Cho, Young Moo;Choe, Changyong
    • Journal of Embryo Transfer
    • /
    • v.31 no.1
    • /
    • pp.47-52
    • /
    • 2016
  • The objective of this study was to investigate the result of in vivo embryo collection and pregnancy rate after embryo transfer using sex-sorted sperm of Korean brindle cattle. Donor Korean brindle cattle superovulation treated by decreasing dose of FSH injection. Embryos were recovered on 7 days after the third artificial insemination. Control group semen straw used artificial insemination contained 20 million sperm. Sex-sorted semen straws contained 4 million sperm or 10 million sperm. As for the result of the recovery of the in vivo embryos derived from sex-sorted sperm, the number of transferable embryos was significantly highly recovered to be $6.20{\pm}2.28/donor$ from the control group and was significantly lowly recovered to be $1.57{\pm}1.72/donor$ from the group treated at a sperm concentration of $10{\times}10^6$ (p<0.05). The number of unfertilized embryo was $0.8{\pm}1.30/donor$ in control group which was significantly lower than the group treated at a sperm concentration of $4{\times}10^6$ (p<0.05). However, there was no significant difference in the number of undeveloped ova between control and treatment groups. Pregnancy rate after embryo transfer was shown to be 35.00% in control group and 12.50% in treatment group. The karyotype analysis of the calf derived from sex-sorted sperm resulted in a similar chromosomal distribution pattern (2n=60, XX) compared to those of common Korean native cattle.

Least-Square Fitting of Intrinsic and Scattering Q Parameters (최소자승법(最小自乘法)에 의(衣)한 고유(固有) Q와 산란(散亂) Q의 측정(測定))

  • Kang, Ik Bum;McMechan, George A.;Min, Kyung Duck
    • Economic and Environmental Geology
    • /
    • v.27 no.6
    • /
    • pp.557-561
    • /
    • 1994
  • Q estimates are made by direct measurements of energy loss per cycle from primary P and S waves, as a function of frequency. Assuming that intrinsic Q is frequency independent and scattering Q is frequency dependent over the frequencies of interest, the relative contributions of each, to a total observed Q, may be estimated. Test examples are produced by computing viscoelastic synthetic seismograms using a pseudo spectral solution with inclusion of relaxation mechanisms (for intrinsic Q) and a fractal distribution of scatterers (for scattering Q). The composite theory implies that when the total Q for S-waves is smaller than that for P-waves (the usual situation), intrinsic Q is dominating; when it is larger, scattering Q is dominating. In the inverse problem, performed by a global least squares search, intrinsic $Q_p$ and $Q_s$ estimates are reliable and unique when their absolute values are sufficiently low that their effects are measurable in the data. Large $Q_p$ and $Q_s$ have no measurable effect and hence are not resolvable. Standard deviation of velocity $({\sigma})$ and scatterer size (A) are less unique as they exhibit a tradeoff as predicted by Blair's equation. For the P-waves, intrinsic and scattering contributions are of approximately the same importance, for S-waves, the intrinsic contributions dominate.

  • PDF