• 제목/요약/키워드: 조한구

검색결과 232건 처리시간 0.025초

필라멘트 와인딩 장력에 따른 Composite Bushing의 특성에 관한 연구 (Properties of Composite Bushing with Filament Winding Tension)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.34-34
    • /
    • 2010
  • This paper describes effect of the bending deformation of high voltage composite bushing with winding tension. The composite bushing can be formed, by adding silicone rubber sheds to a tube of composite materials. The FRP tube is internal insulating part of a composite bushing and is designed to ensure the mechanical characteristics. Generally the properties of FRP tube can be influenced by the winding angle, wall thickness and winding tension. As winding tension is increased glass contents was increased in the range of 70.4~76.6%. In the bending test, winding tension is increased residual deflection was decreased in the range of 14.0~12.2 mm.

  • PDF

초고압 컴포지트 부싱의 최적설계 및 성능에 관한 연구 (Design Optimization and Performance of High Voltage Composite Bushing)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.35-35
    • /
    • 2010
  • This paper illustrates the use of electric field computation to optimize the design of high voltage composite bushing. In the bushing, a high electric stress occurred between field shaper and central conductor by the closely space. Also coaxial cylindrical shield has a great height along the axis to control an electric field. Consequently, all the potentials are raised axially along the field shaper and electric stress is concentrated on a part of the surface of the FRP tube near the upper end of the field shaper. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymer bushing. The optimized design uses internal elements for electric stress grading at critical parts of the bushing.

  • PDF

초고압 폴리머 부싱의 내부쉴드 형상에 따른 전계분포 특성 (Electric Field Distribution of High Voltage Polymer Bushing with Inner Field Shaper Designs)

  • 조한구;유대훈;강형경
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.369-370
    • /
    • 2008
  • This paper describes the electric field distribution of high voltage polymer bushing with inner field shaper designs. The field control can be achieved by means of the designs of such internal field shaper. But high electric stress occurred between field shaper and central conductor by the closely space. In accordance, the floating and ring shield designs was importance for electric stress grading at critical parts of the bushing. The bushing has a central conductor, and internal ring shield or floating shield, gaps are formed between field shaper and ring shield. Accordance equipotential lines extend through gaps. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymer bushing.

  • PDF

Filament Winding에 의한 Composite Hollow Bushing용 GRP tube의 특성 (Characteristics of GRP tube using Composite Hollow Bushing by Filament Winding)

  • 조한구;강형경;유대훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.378-379
    • /
    • 2008
  • Recently, composite hollow bushings have been increasingly employed mainly from the various characteristics. Composite bushings are superior to porcelain bushings in several respects, including lighter weight, better anti-pollution and anti-explosion properties, and easer manufacturing. Filament wound GRP tubes which have various winding angle were manufactured by using a filament winding machine. This paper will show some design issues and winding condition for composite bushing. And, results show that the winding condition of composite GRP tubes can be used to improved their bending strength and pressure, For bending and pressure tested, tubes with the hybrid winding pattern show higher strength than those of unit winding pattern. Also, the influence of absorption was evaluated through such as measurement of the dye penetration test and water diffusion test, also aspects of surface state using scanning electron microscopy.

  • PDF

트랙킹 열화에 미치는 오손액과 표면거칠기의 영향 (The Effect of Contaminants and Surface Roughness on Tracking Aging)

  • 조한구;김인성;강동필;안명상;박용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1673-1675
    • /
    • 1996
  • We have studied the effect of surface tension and flow rate of contaminants, wettability, frequency of applied voltage dependence of tracking breakdown. As the flow rate of contaminant is increasd, the surface resistivity is decreased, and the leakage current is increased, the time to tracking breakdown is decreased. It is found that time to tracking breakdown depends on the frequency of contaminant, that is difference of wettability. And as the frequency of applied voltage is increased, time to tracking breakdown decreased.

  • PDF

옥외용 실리콘 고무 절연재료의 전기적 특성 (The Electrical Properties Dependent on the Filler in Silicone Composite Material for Power Distribution)

  • 김정호;박용관;김인성;조한구;김희곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1597-1599
    • /
    • 1996
  • In this study, we investigated the electrical characteristics such as tracking resistance, dielectric constant, insulating resistance, and arc resistance, of silicone rubber for outdoor use, and, focused on the tracking resistance. In the Inclined Plane Test, two kind of the contamination solutions were used, and their phenomena were observed. The average leakage current and the tracking breakdown time decreased, and erosion rate increased, using anionic surfactant added contaminant solution. The dielectric constant and dissipation factor were increased with increasing temperature.

  • PDF

에폭시-마이카 복합재료의 FEM에 의한 MODELING 열화 해석 (The Modeling Aging Analysis due to Finite Eliment Method on Epoxy-Mica Composites)

  • 김희곤;현중섭;김희동;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1710-1712
    • /
    • 1996
  • This paper was practiced insulation failure test forcing to accelerate on frequency of 420 HZ. There was manufactured generator stator windings for 500MVA thermal plants and selected accelerating deterioration voltage of 5.5kV/mm for electrical aging. Moreover, so as to verification of this experiments, we carried out modeling analysis due to finite element method using to ANSYS5.0 program for common package and imitated multi-stress aging for analyzing electrical and mechanical stress distribution.

  • PDF

송전선로에 사용되는 갭형 피뢰기 소자의 뇌임펄스 전류특성 (Characteristics of Lightning Impulse Current of Zno Block for Transmission Line Arrester with External Gap)

  • 조한구;유대훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.61-62
    • /
    • 2009
  • This paper describes the characteristics of lightning impulse current of ZnO block for transmission line arrester with external gap. The ageing parameters of lightning arresters ate impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by impulse current. Total energy applied to the ZnO arrester each time is $4/10{\mu}s$, 30kA and $2/20{\mu}s$, 10kA impulse current. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test, it is thought that the ZnO arrester shows good stability with impulse current test.

  • PDF

지하철 고분자 지지애자의 설계 및 특성 평가 (Study on a design and characteristics tests of polymeric insulators for subway)

  • 한세원;조한구;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.514-517
    • /
    • 2003
  • Polymeric suspended insulators for subway and electrical track line had been designed and manufactured. The main elements to design polymeric insulators were the insulation ability and the optimal structure. To get the insulation ability, electrical and mechanical tests according to standards had done on housing rubbers and FRP cores and selected the sample with best properties as a insulator. The insulator shape and fitting parts with minimum electrical stress was simulated by FEM electrical field analysis program. The manufactured insulator set had been tested and estimated the electrical and mechanical according to ES and KS, and showed good characteristics in these tests.

  • PDF

Silicon rubber 애자의 salt-fog 표면열화 특성 (Surface Aging Properties of Silicon Rubber Insulator by salt-fog)

  • 이종찬;이운용;조한구;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.255-257
    • /
    • 2001
  • In this paper, the silicon rubber insulator for transmission line was experimented for 1,000 hours aging test in salt-fog condition. To evaluate and examine the aging properties of silicon rubber insulator for test, the leakage current of surface was measured. Also hydrophobicity and scanning electron microscopy were compared with initial and aged sample respectively. Above results, we can confirm that the surface properties of silicon rubber insulator easily aged by salt-fog condition.

  • PDF