• Title/Summary/Keyword: 조도평가

Search Result 319, Processing Time 0.031 seconds

An Analysis of Domestic Research Trends on Museum Lighting (박물관 조명에 관한 국내 연구 동향 분석)

  • Kim, Jiwon;Kang, Daiill
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.3
    • /
    • pp.188-199
    • /
    • 2019
  • In this study, research trends were investigated by examining important academic research on museum lighting that has been carried out in Korea over the past 30 years. The aim was to highlight important studies conducted in Korea on material deterioration caused by museum lighting and to examine the current status of research on LED light sources to provide direction for future research. The ultimate goal of studies on museum lighting is to improve the long-term conservation effects, and this study examined the latest light sources of each era. Prior to the 1990s, the effects of light sources on relics were assessed by investigating incandescent light bulbs and fluorescent lamps, the first museum exhibition lighting. Then in the 1990s, the introduction of halogen lamps and HID lamps led to the analysis of the characteristics of a light source itself and the introduction of illumination standards. In the 2000s, the lighting environment of museums was investigated based on the characteristics of the light sources that had been studied, and in terms of preservation, research was conducted not only to improve the conservation of relics but also to improve the sentiments of visitors. After 2010, LED lamps were introduced; therefore, material deterioration studies on LED lamps were expanded. During this period, enhancements to LED light sources were made, such as reducing the blue spike area and increasing color rendering. With the development of lighting used in museums and art galleries, the direction of the display preservation criteria has led to the need to prepare advanced standards, covering all aspects from the center of illumination to the consideration of the color of an object and the speed of radiation from the light source. Regular studies of museum lighting in a long-term perspective should be planned to standardize the more advanced conditions of material discoloration.

Toxicological Assessment to Environmental Stressors Using Exoskeleton Surface Roughness in Macrophthalmus japonicus: New Approach for an Integrated End-point Development (칠게 외골격 표면 거칠기를 이용한 노출 독성 평가: 새로운 융합적 연구)

  • Park, Kiyun;Kwak, Ihn-Sil
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.4
    • /
    • pp.265-271
    • /
    • 2021
  • Intertidal mud crab (Macrophthalmus japonicus) is an organism with a hard chitinous exoskeleton and has function for an osmotic control in response to the salinity gradient of seawater. Crustacean exoskeletons change in their natural state in response to environmental factors, such as changes in the pH and water temperature, and the presence of pollutant substances and pathogen infection. In this study, the ecotoxicological effects of irgarol exposure and heavy metal distribution were presented by analyzing the surface roughness of the crab exoskeleton. The exoskeleton surface roughness and variation reduced in M. japonicus exposed to irgarol. In addition, it was confirmed that the surface roughness and variation were changed in the field M. japonicus crab according to the distribution of toxic heavy metals(Cd, Pb, Hg) in marine sediments. This change in the surface roughness of the exoskeleton represents a new end-point of the biological response of the crab according to external environmental stressors. This suggests that it may affect the functional aspects of exoskeleton protection, support, and transport. This approach can be utilized as a useful method for monitoring the aquatic environment as an integrated technology of mechanical engineering and biology.

Parameter Sensitivity Analysis of VfloTM Model In Jungnang basin (중랑천 유역에서의 VfloTM 모형의 매개변수 민감도 분석)

  • Kim, Byung Sik;Kim, Bo Kyung;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6B
    • /
    • pp.503-512
    • /
    • 2009
  • Watershed models, which are a tool for water cycle mechanism, are classified as the distributed model and the lumped model. Currently, the distributed models have been more widely used than lumped model for many researches and applications. The lumped model estimates the parameters in the conceptual and empirical sense, on the other hand, in the case of distributed model the first-guess value is estimated from the grid-based watershed characteristics and rainfall data. Therefore, the distributed model needs more detailed parameter adjustment in its calibration and also one should precisely understand the model parameters' characteristics and sensitivity. This study uses Jungnang basin as a study area and $Vflo^{TM}$ model, which is a physics-based distributed hydrologic model, is used to analyze its parameters' sensitivity. To begin with, 100 years frequency-design rainfall is derived from Huff's method for rainfall duration of 6 hours, then the discharge is simulated using the calibrated parameters of $Vflo^{TM}$ model. As a result, hydraulic conductivity and overland's roughness have an effect on runoff depth and peak discharge, respectively, while channel's roughness have influence on travel time and peak discharge.

5 YEARS EVALUATION OF COMPOSITE RESIN RESTORATION ON PERMANENT FIRST MOLAR IN CHILDREN (어린이 제 1 대구치 복합 레진 수복물의 5년 후 임상평가)

  • Kim, In-Young;Kim, Jae-Moon;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.110-117
    • /
    • 2008
  • Clinical performance of resin-based composite material depends on case selection and on the proficiency of the operator. Especially, composite resin restoration on permanent first molar in children have more limitations clinically than adult patients according to stage of tooth eruption and patient's compliance. This study was designed to evaluate the clinical performance of posterior composite resin restoration in children after 5 years. 35 teeth of 16 patients who were received composite resin restoration on permanent first molar in Department of Pediatric dentistry, Pusan National University Hospital between January 2001 and December 2001 were evaluated based on Modified USPHS criteria. From the finding in this study, following conclusions can be made. 1. 6 teeth(17%) of 35 teeth was replaced, so 5-years survival rate of posterior composite resin restoration is 82.9%. 2. As results of each evaluation criteria, on color match, anatomic form, surface roughness, sensitivity/ discomfort, ideal A grade score was 86.2%, 93.1%, 86.2%, 86.2%, clinically accepted B grade score was 13.8%, 0%, 13.8%, 10.3%. On marginal adaptation and marginal discoloration, A grade score was 13.8%, 44.8% and B grade score was 79.3%, 34.5% and secondary caries rate was 20.7%. 3. 69.1% of teeth (20 teeth) was clinically accepted on all evaluation criteria.

  • PDF

Evaluation of MTF Image by Target/Filter Combined of X-ray Tube Using Mammography (유방촬영용 X선관 target/filter 조합에 따른 MTF영상평가에 관한 고찰)

  • Yang, Han-Jun;Joo, Mi-Hwa;Ko, Sin-Kwan
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.113-119
    • /
    • 2007
  • It is important to consider the contrast of object in Mammography because an absorption gap between tissues of body and breast in breast is low. This study is to evaluate MTF image with resolution chart according to change of combination of target and filter. The results were as follows : 1. There were significant differences in X-ray energy according to combination of filter(Mo/Mo, Mo/Rh. Mo/Al, Rh/Rh, Rh/Al) and acrylic thickness(2 cm, 3 cm, 4 cm). 2. The value of lp/mm on MTF to 0.5 showed that the sharpness in MTF curve was 2.4 compared to Mo/Mo and 2cm acryl, 2.63 in Mo/Rh and 4 cm acryl, and 2.9 in Rh/Rh and 6cm acryl. 3. The value of lp/mm on MTF showed that the resolution in MTF curve was 6.0 compared to Mo/Mo and 2 cm acryl, 4.60 in Rh/Al and 4cm acryl, and 6.03 in Rh/Al and 6 cm acryl. 4. The value of MTF on 2.5 lp/mm distinguishable visually was 0.48 compared to Mo/Mo and 2 cm acryl, 0.53 in Mo/Rh and 4cm acryl, and 0.59 in Rh/Rh and 6cm acryl. 5. For the evaluation of an image of the mammo-phantom, the score of Mo/Mo was 12 points, Mo/Rh 11, Rh/Rh 10.5, Mo/Al 10, Rh/Al 9.0, respectively.

  • PDF

Evaluation of Six Species Ciliates as a Live Food and Culture Environment for Euplotes sp. (먹이생물로써의 섬모충 6종의 평가와 Euplotes sp.의 배양 환경)

  • Yoo Jin Hyung;Hur Sung Bum
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.4
    • /
    • pp.342-347
    • /
    • 2002
  • Ciliates have the possibility of a new live food in marine finfish culture because of their wide range of body size, thin tell wall, show motility, and fast reproduction rate. In this research, six species of ciliates were isolated from south coast and salt pond in Korea. The fitness of these species as a live food was evaluated in terms of size, motility, suspensibility and cell density. As the result, Euplotes sp. (K-1) was found suitable to be a new live food which might substitute rotifers, Brachionus plintilis and B. rotundiformis in fish larvae culture. The modified $F{\emptyset}yn's$ Erdschreiberd media, MErds-2 with the addition of glycine, glucose and yeast extract increased six times higher growth rate of Euplotes sp. (K-1) than the basic F$\emptyset$yn's Erdschreiberd media. The optimum water temperature, pH and light intensity for this ciliates were $22.5^{\circ}C$, 8 and 2,000 lux, respectively, and its culture environmental range was relatively wide, On the other hand, this ciliate fed baker's yeast, Saccharomyces cererisiae grew up to 1,240 inds./mL with the inocula of 100 inds./mL within 7 days. The results of the study showed that Euplotes sp. (K-1) has a potential to be utilized as a new live food in fish larvae culture.

Development and Evaluation of an Indirect Illumination for Tongue Image Acquisition (설 영상 획득을 위한 간접 조명 구현 및 평가)

  • Jung, Chang Jin;Kim, Keun Ho;Jang, Jun-Su;Jeon, Young Ju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.221-228
    • /
    • 2014
  • The color and shape of the tongue reflect the physiological and clinico-pathological condition of the body. Recently, various tongue image acquisition devices have been developed for accurate diagnosis based on quantitative and objective tongue features. Since a color information is essential for tongue diagnosis, the performance of an illuminator is very important for the tongue image acquisition device. In this study, we developed an indirect illumination, which is possible to improve a homogeneity of light intensities on the tongue surface, and evaluated its performances. In order to realize the indirect illumination (II), a semi-ellipsoidal solid structure (SESS) for the light reflex was located in the system, and two high-brightness white LEDs were placed for illuminating the areas under frontal camera in the SESS. The tongue surface was illuminated by reflected light from the SESS. The light homogeneity induced by three different illuminations including the II was evaluated by calculating coefficient of variation (CV) of illuminance of five regions. The II showed less than 0.01 of CV and the direct illumination (DI) and the direct illumination with a light diffusion plate (DILDP) showed 0.16 and 0.13, respectively. The reflexed pixel ratios of tongue phantom images show 5.76%, 4.22%, 1.79% for the DI, the DILDP and the II, respectively. The homogeneity of a tongue phantom was evaluated by calculating CV of mean pixel values of six different tongue regions, and showed less than 0.06 in the II. If the II technique apply to tongue diagnosis system, it is expected to improve diagnostic accuracy in clinic.

The evaluation of surface roughness and polishing time between polishing systems (연마시스템에 따른 복합레진의 표면거칠기와 연마시간에 대한 평가)

  • Kim, Ye-Mi;Shin, Su-Jung;Song, Min-Ju;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.119-124
    • /
    • 2011
  • Objectives: The purpose of this experiment was to evaluate four different polishing systems of their polishability and polishing time. Materials and Methods: 4 mm diameter and 2 mm thickness Teflon mold was made. Z-250 (3M ESPE) hybrid composite resin was slightly overfilled and pressed with slide glass and cured with Optilux 501 for 40 sec each side. Then the surface roughness (glass pressed: control group) was measured with profilometer. One surface of the specimen was roughened by #320 grit sand paper and polished with one of the following polishing systems; Sof-Lex (3M ESPE), Jiffy (Ultradent), Enhance (Dentsply/Caulk), or Pogo (Dentsply/Caulk). The surface roughness and the total polishing time were measured. The results were analyzed with one-way ANOVA and Duncan's multiple range test. Results: The surface roughness was lowest in Pogo, and highest in Sof-Lex. Polishing times were shortest with Pogo, and followed by the Sof-Lex, Enhance and Jiffy. Conclusions: One-step polishing system (Pogo) is very effective to get the smooth surface in a short time, therefore it can be recommended for final polishing system of the restoration.

Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF

Study on the improvement of prediction model for the railway environmental noise using ISO 9613-2 (ISO 9613-2를 이용한 철도 환경소음 예측 모델 개선에 관한 연구)

  • Jang, Seungho;Koh, Hyo-In;Hong, Jiyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.1
    • /
    • pp.11-26
    • /
    • 2017
  • Approximate empirical equations obtained by measuring overall noise levels at different distances have been used to evaluate environmental influence of the railway noise though the accurate prediction of noise levels is important. In this paper, a noise prediction model considering the frequency characteristics of noise sources and propagation was suggested to improve the accuracy of noise prediction. The railway noise source was assorted into track, wheel, traction and aerodynamic components and they were characterized with the source strength and speed coefficient at each octave-band frequency. Correction terms for the acoustic roughness and the track/bridge condition were introduced. The sound attenuation from a source to a receiver was calculated taking account of the geometrical divergence, atmospheric absorption, ground effect, diffraction at obstacles and directivity of source by applying ISO 9613-2. For obtaining the source strength and speed coefficients, the results of rolling noise model, numerical analysis and measurements of pass-by noise were analyzed. We compared the predicted and measured noise levels in various vehicles and tracks, and verified the accuracy of the present model. It is found that the present model gives less error than the conventional one, so that it can be applied to make the accurate prediction of railway noise effect and establish its countermeasures efficiently.