• Title/Summary/Keyword: 조도측정

Search Result 490, Processing Time 0.024 seconds

Effects of Intercrops on Growth and Yield of Paeonia Lactiflora PALLAS. (간작물(間作物)이 작약(芍藥)의 생육(生育) 및 수양(收量)에 미치는 영향(影響))

  • Hwang, Hyung-Baek;Kim, Jae-Chul;Park, So-Deug;Chol, Boo-Sull;Lim, Joo-Rag
    • Korean Journal of Medicinal Crop Science
    • /
    • v.4 no.3
    • /
    • pp.212-217
    • /
    • 1996
  • This study was carried out to select proper intercrops in peony cultivation because peo­ny is damaged easily by disease and cannot make proper income with it's single crop system, so it needs rational intercropping system to raise it's productivity and income. The results of this study are as follows. The kinds of soil nematodes were Meloidogyne sp, Pratyienchus sp, Aphelenchoides sp, Ditylenchus sp, Xiphinema sp, and damaging dominant nematode was Meloidogyne sp. The density of Meloidogyne sp wa suppressed remarkably in the combination of peony+sesame, and peony + job's tears. This study shows that sesame and job's tear were most resistant crops to the IvIeloi­dogyne sp. The quanity of herbaceous peony was the best in the combination of peony+red pepper. The results of income analysis per lOa for three years shows next conclusion. Peony+red pepper combination and peony+ sesame combination were most effective when it's compared with single cropping of peony (1,490 thousand won). But red pepper was damaged easily by soil nematode, therefore, sesame was the most stable and high yield crop as a intercrop in the cultivation of herbaceous peony.

  • PDF

Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF

CASE REPORTS OF TREATMENT OF ERUPTION-DISTURBED MX. FIRST MOLAR BY SURGICAL EXPOSURE (맹출 장애를 가진 상악 제1대구치의 외과적 노출을 이용한 치험례)

  • Seok, Choong-Ki;Nam, Dong-Woo;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • The eruption of permanent teeth represents the movement in the alveolar bone before appearance in oral cavity, to the occlusal plane after appearance in oral cavity, and additive movement after reaching th the occlusal plane. Tooth eruption is mostly controlled by genetic signals. The eruption stage is divided to preeruptive alveolar stage, alveolar bone stage, mucosal stage according to the process of growth and development. If the disturbance is occured in any stage of eruption, tooth does not erupt. The cause of eruption disturbance are ectopic position of the tooth germ, obstruction of the eruption path and defects in the follicle or PDL. In the treatment of eruption disturbance, surgical procedures are commonly used. There are three kind of surgical procedure ; surgical exposure, surgical repositioning, surgical exposure and traction Surgical exposure is basic procedure. This involves removal of mucosa, bone, lesion that are surrounding the teeth, dental sac when necessary to maintain a patent channel between the crown and the normal eruptive path into the oral cavity. To ensure this patency, many techniques including cementation of a celluloid crown, packing with gutta-percha or zinc oxide-eugenol, or a surgical pack, are used. When surgical exposure is conducted, operators should not expose any part of cervical root cement and not injure periodontium or root of adjunct tooth. After surgical exposure, tooth should be surrounded by keratinized gingiva. There is direct relationship between the extent of development of pathophysiologic aberrations and the intensity of the manipulative injury inflicted on the tooth by surgical treatment, so operator should consider this thing. In these cases, surgical exposure is conducted on Maxillary 1st milars that have a eruption disturbance and improve the eruption disturbance effectively.

  • PDF

Application of the Homogenization Analysis to Calculation of a Permeability Coefficient (투수계수 산정을 위한 균질화 해석법의 적응)

  • 채병곤
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 2004
  • Hydraulic conductivity along rock fracture is mainly dependent on fracture geometries such as orientation, aperture, roughness and connectivity. Therefore, it needs to consider fracture geometries sufficiently on a fracture model for a numerical analysis to calculate permeability coefficient in a fracture. This study performed new type of numerical analysis using a homogenization analysis method to calculate permeability coefficient accurately along single fractures with several fracture models that were considered fracture geometries as much as possible. First of all, fracture roughness and aperture variation due to normal stress applied on a fracture were directly measured under a confocal laser scaning microscope (CLSM). The acquired geometric data were used as input data to construct fracture models for the homogenization analysis (HA). Using the constructed fracture models, the homogenization analysis method can compute permeability coefficient with consideration of material properties both in microscale and in macroscale. The HA is a new type of perturbation theory developed to characterize the behavior of a micro inhomogeneous material with a periodic microstructure. It calculates micro scale permeability coefficient at homogeneous microscale, and then, computes a homogenized permeability coefficient (C-permeability coefficient) at macro scale. Therefore, it is possible to analyze accurate characteristics of permeability reflected with local effect of facture geometry. Several computations of the HA were conducted to prove validity of the HA results compared with the empirical equations of permeability in the previous studies using the constructed 2-D fracture models. The model can be classified into a parallel plate model that has fracture roughness and identical aperture along a fracture. According to the computation results, the conventional C-permeability coefficients have values in the range of the same order or difference of one order from the permeability coefficients calculated by an empirical equation. It means that the HA result is valid to calculate permeability coefficient along a fracture. However, it should be noted that C-permeability coefficient is more accurate result than the preexisting equations of permeability calculation, because the HA considers permeability characteristics of locally inhomogeneous fracture geometries and material properties both in microscale and macroscale.

모재/중간층/박막의 H/E ratio 구배에 따른 Cr계 경질 박막의 기계적 특성에 관한 연구

  • Kim, Hoe-Geun;Song, Myeon-Gyu;Lee, Sang-Yul
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.135-135
    • /
    • 2018
  • 천이금속 질화물 코팅은 우수한 기계적 특성들로 인해 공구 코팅으로 많이 사용 되어왔다. 그 중에서도 특히 Cr계 경질 코팅은 높은 경도와 낮은 표면조도, 우수한 마찰특성 등 뛰어난 기계적 특성을 나타내므로 공구 코팅으로의 적용 가능성이 크다. 그러나 최근 공구산업의 발전으로 인해 공구가 더욱 가혹한 환경에서 사용됨에 따라, 공구의 수명을 향상시키고 보호하기 위해 코팅의 높은 밀착력이 요구되고 있으며, 모재와 코팅 사이에 중간층을 합성함으로써 공구의 밀착력을 향상시키는 연구가 활발히 진행되고 있다. 이전 연구에서 모재/중간층/코팅간의 경도와 탄성계수 비율(H/E ratio)의 구배가 코팅의 밀착력에 큰 영향을 미치는 것으로 확인되었다. 그러므로, WC 모재와 Cr계 코팅의 중간값의 H/E ratio를 갖는 중간층의 합성을 통해 코팅의 밀착력을 향상시킬 수 있을 것으로 판단된다. 본 연구에서는, 코팅의 밀착력을 향상시키기 위해 다양한 중간층을 증착한 CrZrN, CrAlN 코팅을 비대칭 마그네트론 스퍼터링 장비를 이용하여 합성하였다. 모재로는 디스크 형상의 WC-6wt.%Co 시편을 사용하였고 Cr, Zr, Si, Al single 타겟을 이용하여 Cr, CrN, CrZrN, CrZrSiN 등의 중간층이 증착된 코팅을 합성했다. 코팅의 합금상, 경도 및 탄성계수, 미세조직 및 조성, 표면 조도을 확인하기 위해 X-ray diffractometer (XRD), Fischer scope, field-emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), atomic force microscopy를 사용하였고, 코팅의 밀착 특성을 분석하기 위해 scratch tester와 optical microscopy (OM)를 이용하였다. 코팅의 내열성을 확인하기 위해 코팅을 furnace에 넣어 공기중에서 500, 600, 700, 800, 900, $1,000^{\circ}C$로 30분 동안 annealing 한 후에 nano-indentation을 사용하여 경도를 측정하였다. CrZrN 및 CrAlN 코팅을 나노 인덴테이션으로 분석한 결과, 모든 코팅의 경도(33.4-35.8 GPa)와 탄성계수(384.1-391.4 GPa)는 중간층의 종류에 상관없이 비슷한 값을 보인 것으로 확인됐다. 그러나, 코팅의 마찰계수는 중간층의 종류에 따라 다른 값을 보였다. CrZrN 코팅의 경우 CrN 합금상 중간층을 갖을 때 가장 낮은 값을 보였으며, CrAlN 코팅의 경우 CrN/CrZrSiN 중간층을 증착하였을때 마찰계수는 0.34로 CrZrN 중간층을 증착하였을 때(0.41)에 비해 낮은 값을 보였다. 또한, 코팅의 마모율 및 마모폭도 비슷한 경향을 보인 것으로 보아, CrN/CrZrSiN 중간층을 합성한 CrAlN 코팅의 내마모성이 상대적으로 우수한 것으로 판단된다. 코팅의 밀착력의 경우도 마찰계수와 비슷한 경향을 보였다. 이것은 중간층의 H/E ratio가 코팅의 내마모성에 미치는 영향에 의한 결과로 사료된다. H/E ratio는 파단시의 최대 탄성 변형율로써, 모재/중간층/코팅의 H/E ratio 구배에 따라 코팅 내의 응력의 완화 정도가 변하게 된다. WC 모재 (H/E=0.040)와 CrAlN 코팅(H/E=0.089) 사이에서 CrN, CrZrSiN 중간층의 H/E ratio는 각각 0.076, 0.083으로 모재/중간층/코팅의 H/E ratio 구배가 점차 증가함을 확인 할 수 있었고, 일정 응력이 지속적으로 가해지면서 진행되는 마모시험중에 CrN과 CrZrSiN 중간층이 WC와 CrAlN 코팅 사이에서 코팅 내부의 응력구배를 완화시키는 역할을 함으로써 CrAlN 코팅의 내마모성이 향상된 것으로 판단된다. 모든 코팅을 열처리 후 경도 분석 결과, CrN/CrZrSiN 중간층을 증착한 CrAlN 코팅은 $1,000^{\circ}C$까지 약 28GPa의 높은 경도를 유지한 것으로 확인 되었고, 이는 CrZrSiN 중간층 내에 존재하는 SiNx 비정질상의 우수한 내산화성에 의한 결과로 판단된다.

  • PDF

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).

Surface roughness analysis of ceramic bracket slots using atomic force microscope (원자현미경을 이용한 세라믹 브라켓 슬롯의 표면조도에 대한 연구)

  • Park, Ki-Ho;Yoon, Hyun-Joo;Kim, Su-Jung;Lee, Gi-Ja;Park, Hun-Kuk;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.294-303
    • /
    • 2010
  • Objective: This study was designed to measure the surface roughness at the slot floor of various ceramic brackets. Methods: One kind of stainless steel bracket ($Succes^{(R)}$), two kinds of monocrystalline brackets (Inspire $Ice^{(R)}$, $Perfect^{(R)}$) and two kinds of polycrystalline brackets (Crystalline $V^{(R)}$, $Invu^{(R)}$) were examined. Atomic force microscopy (AFM) was used to measure the surface roughness of each bracket. Data acquisition and processing were performed using $SPIP^{TM}$. Results: The differences in values of Sa, Sq, and Sz in $Invu^{(R)}$ and Inspire $Ice^{(R)}$ were not statistically different from the control group $Succes^{(R)}$. The values of Sa, Sq, and Sz of $Perfect^{(R)}$ and Crystalline $V^{(R)}$ were greater than those of $Succes^{(R)}$. Differences of all the Sa, Sq, and Sz values between $Perfect^{(R)}$ and Crystalline $V^{(R)}$ were not statistically significant. Conclusions: It is concluded that the slot surfaces of $Succes^{(R)}$, Inspire $Ice^{(R)}$, and $Invu^{(R)}$ were smooth compared to those of Crystalline $V^{(R)}$ and $Perfect^{(R)}$.

Effects of Wind Net Shading and Sprinkling on Growing Conditions and Fruit Quality in 'Hongro' and 'Fuji' Apple Fruits (방풍망 차광시설 및 미세살수 처리가 '홍로' 및 '후지' 사과나무의 생육환경 및 과실 품질에 미치는 영향)

  • Kang, Kyeong-Jin;Seo, Jeong-Hak;Yoon, Hong-Ki;Seo, Jeong-Seok;Choi, Taek-Yong;Chun, Jong-Pil
    • Journal of Bio-Environment Control
    • /
    • v.28 no.2
    • /
    • pp.126-133
    • /
    • 2019
  • In recent years, the deterioration of fruit quality caused by poor coloration and sunburn disorder has become serious problems in apple market, which is a result of the increase of surface temperature due to the abnormal temperature increase during summer season. This study was conducted to investigate the effect of wind net shading and fine water spray using sprinkler on fruit coloration, sunburn damage and overall fruit quality of 'Fuji' and 'Hongro' apples. Fifteen sprinklers (7L/hr) were installed at the orchard of the Chungcheongnam-do Agricultural Research and Extension Services, located in Sinam-myeon Chungcheongnam-do Korea, at a height of 3m above the apple tree of $1.5m{\times}3.5m$ north-south direction. Fine water spraying treatment was divided into day time spray (10:00 am to 6:00 pm) and all day spray (10:00 am to 10:00 pm) from early July to 10 days before harvest in 2017 and 2018 season, respectively. Temperature of the surface of apple fruit, characteristic of fruit, and degree of sunburn damage were investigated. In 'Fuji', the fruit surface temperature checked at 2 pm on August 10 was decreased considerably in the day time spray ($35.6^{\circ}C$) and wind net ($39.0^{\circ}C$) when compared with the untreated control ($44.4^{\circ}C$). Similarly, the fruit surface temperature also decreased considerably in the all day spray ($35.1^{\circ}C$) and wind net ($36.9^{\circ}C$) treatments when compared with the untreated control ($46.5^{\circ}C$) in 'Hongro' apples. The incidence of sunburn disorder was significantly decreased with day time spray (5.0%), all day spray (5.8%) and wind net (7.0%) when compared with untreated control (23.4%) in 'Fuji' apples. As a results, the treatment of fine water spray and wind net consequently showed 26% and 34% increase of redness ($a^*$) value in the skin color difference, respectively, in 'Fuji' apples.

Effect of fabrication method and surface polishing on the surface roughness and microbial adhesion of provisional restoration (임시 수복물의 제작 방식과 표면 연마가 표면 거칠기와 세균 부착에 미치는 영향)

  • Yeon-Ho Jung;Hyun-Jun Kong;Yu-Lee Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.149-158
    • /
    • 2024
  • Purpose: This study aims to investigate the effects of provisional restoration fabrication methods and surface polishing on surface roughness and microbial adhesion through in vitro experiments. Materials and Methods: 120 cylindrical provisional restoration resin blocks (10 × 10 × 2.5 mm) were manufactured according to four fabrication methods, and 30 specimens were assigned to each group. Afterwards, they were divided into non-polishing group, #400 grit SiC polishing group, and #800 grit SiC polishing group and polished to a 10 × 10 × 2 mm specimen size (n = 10). The surface roughness Ra and Ry of the specimen was measured using a Surface Roughness Tester. Three specimens were extracted from each group and were coated with artificial saliva, and then Streptococcus mutans were cultured on the specimens at 37℃ for 4 hours. The cultured specimens were fixed to fixatives and photographed using a scanning electron microscope. For statistical analysis, the two way of ANOVA was performed for surface roughness Ra and Ry, respectively, and the surface roughness was tested post-mortem with a Scheffe test. Results: The fabrication method and the degree of surface polishing of the provisional restorations had a significant effect on both surface roughness Ra and Ry, and had an interaction effect. There was no significant difference in Ra and Ry values in all polishing groups in DLP and LCD groups. Conclusion: The fabrication method and surface polishing of the provisional restoration had a significant effect on surface roughness and showed different adhesion patterns for S. mutans adhesion.

Changes of the surface roughness depending on immersion time and powder/liquid ratio of various tissue conditioners (수종의 조직 양화재의 침수시간과 분액비에 따른 표면 거칠기의 변화)

  • Kim, Kyung-Soo;Moon, Hong-Suk;Shim, June-Sung;Jung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.108-118
    • /
    • 2009
  • Statement of problem: Volume stability, microstructure reproducibility and fluidity along with compatibility with dental stone must be in consideration in order to use tissue conditioner as a material for functional impression. There are few studies concerning the influence of time factor in oral condition on surface roughness of the stone and optimal retention period in the oral cavity considering such changes in surface roughness. Purpose: The purpose of this study was to find out the influence of various kinds of tissue conditioner, its powder/liquid ratio and immersion time on surface roughness of the stone. Material and methods: Materials used in this study were the three kinds of tissue conditioners(Coe-Comfort, Visco-Gel, Soft-Liner) and were grouped into three: group R-mixed with standard powder/liquid ratio that was recommended by the manufacturers, group M-mixed with 20% more powder, group L-mixed with 20% less powder. Specimens were made with the size of 20 mm diameter and 2 mm width. Each tissue conditioner specimens were subdivided into 5 groups according to the immersion time(0 hour, 1 day, 3 days, 5 days, 7 days), completely immersed into artificial saliva and were stored under $37^{\circ}C$. Specimens of which the given immersion time elapsed were taken out and were poured with improved stone, making the stone specimens. Surface roughness of the stone specimens was measured by a profilometer. Results: Within the limitation of this study, the following results were drawn. 1. Major influencing factor on surface roughness of the stone model made from tissue conditioner was the retention period(contribution ratio($\rho$)=62.86%, P<.05) of the tissue conditioner in oral cavity to make functional impression. 2. In case of Coe-Comfort, higher mean surface roughness value of the stone model with statistical significance was observed compared to that of Soft-Liner and Visco-Gel as immersion time changes(P<.05). 3. In case of group L(less), higher mean surface roughness value of the stone model with statistical significance was observed compared to that of R(recommended) and M(more) group as immersion time changes(P<.05). Conclusion: We may conclude that as the retention period of time in oral cavity influences surface roughness of the stone model the most and as the kind of tissue conditioner and its P/L ratio may influence also, clinician should well understand the optimal retention period in oral cavity and choose the right tissue conditioner for the functional impression, thus making the functional impression with tissue conditioner usefully.