The Design and Implementation of Remote Monitoring Technology for URC Robot (URC 로봇 원격 모니터링기술 설계 및 구현)

  • Lee, Tae-Hee;Lim, Dong-Sun;Kim, Joo-Man
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.05a
    • /
    • pp.136-139
    • /
    • 2006
  • In this paper, We are proposed the real-time monitor and control mechanism for intelligent robot called URC(Ubiquitous Robotic Companion). URC are intelligent robots designed as to interact with external digital device that can communicate through wire or wireless by integration the network and information technology into traditional robot. In this paper, we implemented the result of this study into the target robot called ISSAC4 and proved its practical worth. We designed it as be able to control on remote by such web browser as anywhere and anytime that show a status information for several controllers, devices, actuators and sensors of robot and guarantee a continuity of real-time image transferring by Client-Pull method and moving control of robot.

  • PDF

Research about performance improvement intelligence of over current protection relay (과전류보호계전기의 지능화 성능개선에 관한 연구)

  • Park, Chan-Won;Jeon, Chan-Min;Chun, Sam-Sug;Kim, Dong-Ju;Kim, Jeong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2319-2321
    • /
    • 2003
  • 본 연구에서는 전력계통에서 배전반 자동화 장치중 하나인 ACB(air circuit breaker) controller로 사용되는 OCR(Over Current Protection Relay)의 지능화와 성능개선을 모색하고자 한다. 개발된 이 장치는 전력계통에서 전류의 흐름을 지능화 알고리즘으로 감시하여 최적으로 사고를 방지할 수 있으며, 대화형의 다양한 기능과 통신기능을 내장하고 있어 원격제어 및 관리가 가능하는 특징을 포함한다.

  • PDF

Condition Monitoring and Fault Diagnosis System of Rotating Machinery (회전기기의 상태감시 및 결함탐지 시스템)

  • Jeong, Sung-Hak;Lee, Young-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.819-820
    • /
    • 2016
  • Electrical power distribution is consists of high voltage, low voltage and motor control center(MCC). Motor control centers involves turning the motor on and off, it is configured electronic over current relay to detect a motor overcurrent flows. Existing electronic over current relay detects electrical fault such as overcurrent, undercurrent, phase sequence, negative sequence current, current unbalance and earth fault. However, it is difficult to detect mechanical fault such as locked rotor, motor stator and rotor and bearing fault. In this paper, we propose a condition monitoring and fault diagnosis system for electrical and mechanical fault detection of rotating machinery. The proposed system is designed with signal input and control part, system interface part and data acquisition board for condition monitoring and fault diagnosis, it was possible to detect electrical fault and mechanical fault through measurement and control of insulation resistance, locked rotor, MC counter and bearing temperature.

  • PDF

The Study on Centralization & Electronic for Maintenance Efficiency of Ground Signaling System (지상신호설비의 유지보수 효율화를 위한 집중화 및 전자화 연구)

  • Baek, Jong-Hyen;Kim, Yong-Kyu;Lee, Kang-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2983-2988
    • /
    • 2010
  • The train control system used in Gyeongbu-line is classified in ATC, IXL and CTC. Domestic railway signaling systems are being developed by electrification. In these systems the electrification of interlocking reaches 57% and the safety equipments of railway crossings in trackside devices have completed their development into an integrated system. Block systems of all the existing sections have not yet electrified and integrated so that they need a number of complement in terms of construction and maintenance. For ABS currently used in existing domestic lines, and LEU being installed in Gyeongbu and Honam lines, although a train is controlled by the signaling information of the same train in the same location, the system is separately installed so that the same information is separately divided and transmitted at the each distinct system. Therefore, in the conventional ABS and LEU, there are a lot of duplicate installed compartments such as lamp detection and a power supply unit. Hence, we have a lot of problems: for maintenance, a lot of manpower and costs need to be invested and the overall manufacturing costs get higher, as well as the construction costs by duplicate. Therefore, this paper suggest design to develop an integrated electronic Block Control Unit by the integration of the currently used ABS, and communication and electronic technology. We are to monitor and manage the block systems in the corresponding station by integrating. And we are to transmit information together with LEU, which is an ATS wayside transmitter.

Leakage and Scattered Radiation from X-ray Unit in Radiography (영상의학과 엑스선 발생장치의 누설 및 산란선량 측정)

  • Im, In-Chul;Lee, Jae-Seung;Kweon, Dae-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.155-159
    • /
    • 2011
  • The purposed of this study were measured the radiation exposure of patients and workers by generators, and the protection state for radiation facilities. The subject of the study by X-ray generators in university hospitals of capital area, we measured the maximum irradiation condition of 80 kVp, 200 mA, 0.1 second in the control entrance, control room window, entrance of radiography, adjacent site. The leakage dose per week was which the control entrance was 0.11 mR/week, control room window was 0.15 mR/week, entrance of radiography was 0.12 mR/week and adjacent site was 0.06 mR/week with X-ray unit the mean And the leakage mean dose was 0.11 mR/week. Diagnostic X-ray tubes must ensure that the leakage radiation in the maximum leakage dose in week emitted by the tube outside the useful beam does not exceed certain levels provided by standards.

A study on the implementation of digital anti-fire monitoring system with multipoint communication protocol (다중포인트 통신 프로토콜을 지원하는 디지털 화재 방지 모니터링 시스템 구현에 관한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1423-1428
    • /
    • 2012
  • In this paper, we investigated an implementation of anti-fire monitoring system based on the RS-485 communication to support local area coverage within a range of 1 Km range. We developed a Multi Point Communication Protocol supporting input/output information processing and control up to 8128 terminal check points, which provides an interface between the anti-fire monitoring system receiver and multiplex transponders. Additionally, a multiplex transponders controller has been designed for the implemented system to comply with the government regulation on fire protection, especially to monitor, report and control 1016 terminal check points within the time limit.

Design of direction control system for camera, Using sound source recognition and delay time. (음원인식 및 지연시간을 이용한 카메라의 방향제어 시스템 설계)

  • Lee, Hui-Tae;Kim, Young-Sub
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.1076-1078
    • /
    • 2017
  • 본 연구는 이상음원(비명, 유리창 파손음, 경적소리 등) 발생 시, 2개의 마이크로폰에 입력되는 사운드에 대하여 음원 방향추적 장치와 연결된 카메라에 음원의 방향 정보를 전송함으로써, 카메라의 View Point를 음원 발생방향으로 이동시켜 사고현장을 더욱 신속하게 대처할 수 있는 시스템에 대한 연구이다. 일반적인 음성을 이용한 감시카메라는 단순히 소리 발생 여부만 감지하지만, 본 시스템은 이상음원 발생 지점으로 카메라의 방향 제어를 가능하게 한다. 이상음원의 검출은 기존에 수집한 DB를 기반으로 비교, 분석 과정을 통하여 이상음원을 분류한다. 음원 발생 방향은 음원 발생 시, 마이크로폰에 도달하는 음원의 시간차에 따른 음파의 위상차를 계산하여 음원 발생 방향을 판단하게 된다.

Study on Development of Embedded HMI System for PLC Monitoring (PLC 모니터링을 위한 임베디드 HMI 시스템의 개발에 관한 연구)

  • Sun, Bok-Keun;Han, Kwang-Rok;Rim, Kee-Wook
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.42 no.4 s.304
    • /
    • pp.1-10
    • /
    • 2005
  • Recently, most of PLC has been using widely in automation equipment that is needed for field of industry automation. HMI is essential system for effective Control of many numbers of PLC. Even though early HMI system was consists of simple analog devices, however, HMI system could control or supervise PLC through display screen since it embeds various digital parts by development of technology in these days. HMI system consists of three parts as HMI hardware, an operating program for HMI equipment and a HMI screen editor. Among these elements, a Program for editing screen of HMI should provide various screen elements that helps users to edit each screens displayed on HMI. In this study, we design and implement screen edit program by object-oriented method for small HMI equipment and propose Prototype of embedded HMI system.

The Development of Remote Monitoring Technology for URC Robot (URC 로봇 원격 모니터링기술 개발)

  • Kim Joo-Man
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.8
    • /
    • pp.8-19
    • /
    • 2006
  • In the ubiquitous environment, the real-time remote control and monitoring technology for intelligent robot creates service as a sharable and independent of time-location for various contents to get from a sensor or camera of the robot. In this paper, We propose the real-time monitor and control mechanism for intelligent robot called URC(Ubiquitous Robotic Companion). URC are intelligent robots designed as to interact with external digital device that can communicate through wire or wireless by integration the network and information technology into traditional robot. It has been carried out by implementing this technology into the target robot called ISSAC4 and proving its practical worth. We designed feasibly to control on remote site by web-browser. It guarantees a continuity of real-time image transferring by Client-Pull method.

  • PDF

A Study on the Automation of MVDC System-Linked Digital Substation (MVDC 시스템연계 디지털변전소 자동화 연구)

  • Jang, Soon Ho;Koo, Ja Ik;Mun, Cho Rong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.7
    • /
    • pp.199-204
    • /
    • 2021
  • Digital substation refers to a substation that digitizes functions and communication methods of power facilities such as monitoring, measuring, control, protection, and operation based on IEC 61850, an international standard for the purpose of intelligent power grids. Based on the intelligent operating system, efficient monitoring and control of power facilities is possible, and automatic recovery function and remote control are possible in the event of an accident, enabling rapid power failure recovery. With the development of digital technology and the expansion of the introduction of eco-friendly renewable energy and electric vehicles, the spread of direct current distribution systems is expected to expand. MVDC is a system that utilizes direct current lines with voltage levels and transmission capacities between HVDCs applied to conventional transmission systems and LVDCs from consumers. Converting existing lines in substations, where most power equipment is alternating current centric, to direct current lines will reduce transmission losses and ensure greater current capacity. The process bus of a digital substation is a communication network consisting of communication equipment such as Ethernet switches that connect installed devices between bay level and process level. For MVDC linkage to existing digital substations, the process level was divided into two buses: AC and DC, and a system that can be comprehensively managed in conjunction with diagnostic IEDs as well as surveillance and control was proposed.