• Title/Summary/Keyword: 정적 실험

Search Result 1,339, Processing Time 0.026 seconds

Static and Dynamic Tests on Laminated Rubber Bearings (적층(積層)고무받침의 정적(靜的) 및 동적(動的) 특성실험(特性實驗))

  • Kim, Nam Sik;Lee, Dong Guen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.85-93
    • /
    • 1993
  • Base isolation systems are economic and efficient for the control of structural vibration. In this study, the base isolators of LRB(laminated rubber bearing) type which have been generally used are fabricated and tested. From the static and dynamic tests, the characteristics of the base isolators, considering strain-hardening, hysteretic damping and horizontal stiffnesses, etc., are verified and particularly the feasibility as base isolation devices is discussed. Consequently, the test results are compared with the analytical ones that are derived from idealization as a bilinear model.

  • PDF

Static Experiment for the Seismic Performance of a 2 Story RC Shear Wall System (2층 RC 전단벽식 구조물의 내진성능에 대한 정적 실험)

  • Lee, Sang-Ho;Oh, Sang-Hoon;Hwang, Won-Tae;Lee, Kyung-Bo;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.55-65
    • /
    • 2010
  • The purpose of this experimental study is to evaluate the seismic performance of a 2 story RC shear wall system by the static reversal loading test. The lower 2 stories of the prototype structure were selected, and the specimens of this study were comprised of a T-type wall with an opening. The specimens were reduced to about 60% of the full scale size and were constructed to measure the result of the experimental variable regarding the existence of a lintel beam. To perform this study, the static repeated loading test was performed. According to the existence or absence of a lintel beam, the structural capacities and behavioral differences of the shear wall system were compared. The test results of this study showed that the specimen with a lintel beam underwent the seismic performance with an ultimate strength and ductility capacity better than the specimen without a lintel beam.

Comparison of Lateral Pile Behavior under Static and Dynamic Loading by Centrifuge Tests (원심모형 실험을 이용한 지반-말뚝 상호작용의 정적 및 동적 거동 평가)

  • Yoo, Min-Taek;Kwon, Sun-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.7
    • /
    • pp.51-58
    • /
    • 2018
  • In this study a series of centrifuge tests were carried out in dry sand to analyze the comparison of lateral pile behavior for static loading and dynamic loading condition. In case of static loading condition, the lateral displacement was applied up to 50% of pile diameter by deflection control method. And the input sine wave of 0.1 g~0.4 g amplitude and 1 Hz frequency was applied at the base of the soil box using shaking table for dynamic loading condition. From comparison of experimental static p-y curve obtained from static loading tests with API p-y curves, API p-y curves can predict well within 20% error the ultimate subgrade reaction force of static loading condition. The ultimate subgrade reaction force of experimental dynamic p-y curve is 5 times larger than that of API p-y curves and experimental static p-y curves. Therefore, pseudo-static analysis applied to existing p-y curve for seismic design could greatly underestimate the soil resistance at non-linear domain and cause overly conservative design.

Compressive Characteristics of Composites According to the Micro-structure and Stacking angle (직조구조차이와 적층각의 변화에 따른 섬유강화복합재료의 압축특성)

  • Yoo, Seong-Hwan;Park, Seok-Won;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.22 no.1
    • /
    • pp.15-21
    • /
    • 2009
  • In this paper, static compressive test and compression-compression fatigue test of carbon/epoxy composites which have different micro-structures were carried out with respect to the bias angle. In order to find out the effect of the micro-structure of the fabric composite on compressive characteristics the specimens made of UD carbon/epoxy composite comprising the same fiber and matrix system as the fabric composite were also prepared. The compressive strength and modulus were measured and these values were used to develop a semi-empirical formula for predicting compressive strength of the fabric composite with bias angles. The fatigue behavior of the fabric composite with respect to the bias angle variation was also investigated.

On Quasi-Static Crushing of a Stiffened Square Tube (보강된 정사각형 단면 강관의 정적 압괴거동에 관한 연구)

  • Paik, Jeom Kee;Chung, Jang Young;Chun, Min Sung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.109-123
    • /
    • 1996
  • A series of quasi-static crushing tests were carried out on thin-walled square tube specimens with axial and/or circumferential stiffeners including unstiffened specimens. The effective crushing length and mean crushing strength of the test specimens were investigated. Using the equivalent plate thickness approach, a simplified analytical model for predicting the mean crushing strength of stiffened square tubes has been developed.

  • PDF

A Study on Seismic Retrofit Design of the Stabilized Piles by 1g Shaking Table Tests and Pseudo-static Analysis (1g 진동대 실험 및 등가정적해석을 이용한 억지말뚝의 사면안정 내진보강 효과 연구)

  • Han, Jin-Tae;Cho, Jong-Suck;Yoo, Min-Taek;Lee, Seung-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.93-101
    • /
    • 2011
  • Korea has about 70% of its land classified as the mountain area, which has led to cut-slope being the result of substantial road and railway construction. However, there is currently a lack of research about the seismic retrofit design of a slope, even though many earthquakes have recently occurred at home and abroad. In this study, in order to investigate the stabilizing effect of piles against sliding during an earthquake, a series of 1 g shaking table tests and pseudo-static analyses were carried out. As a result, the stabilizing effect of piles against sliding during an earthquake was verified by the 1 g shaking table tests and the most effective result from the pseudo-static analyses was that the installation of the piles on the central part of the slope, where the failure surface included piles unlike the lower part and upper part of the slope. Furthermore, when the pile was installed on the central part of the slope, the change of the safety factor depending on the distance between the center of two piles was evaluated.

A Fracture Study on the Bonded DCB Specimen of the Mode III Type with Aluminum Foam (알루미늄 폼으로 된 Mode III 형의 접합된 DCB 시험편에 대한 파괴 연구)

  • Lee, Jung-Ho;Cho, Jae-Ung;Cheon, Seong-Sik
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.191-196
    • /
    • 2015
  • In this study, the static analysis and experiment were carried out on DCB specimens manufactured with aluminum foam in order to investigate the fracture toughness at the adhesive joint of the structure bonded with adhesive. In case of static analysis, all specimen models were shown to have the maximum reaction force when the forced displacement proceeded as much as 5 mm. The maximum reaction forces became 0.25 kN, 0.28 kN and 0.5 kN respectively in cases of specimen thicknesses of 35 mm, 45 mm and 55 mm. Two specimens in case of static experiment were selected to verify these analysis results. The maximum reaction forces were shown when the forced displacement proceeded as much as 5 to 6 mm. The maximum reaction forces became 0.22 kN and 0.3 kN respectively in cases of specimen thicknesses of 35 mm and 45 mm. By comparing the derived results, it could be shown that there was not much difference between the data of analyses and experiments. Therefore, It is inferred that the study data can be secured with only analysis by no extra experimental procedure. It is thought that the mechanical properties at the structure bonded of DCB with the type of mode III can be analyzed systematically.

2-Dimensional Section Model Experimental Study of 1200m Span Cable-Stayed Bridge (주경간 1200m급 사장교 2차원 단면모형실험)

  • Lee, Ho-Yeop;Chun, Nak-Hyun;Oh, Seung-Taek;Lee, Hak-Eun
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.76-76
    • /
    • 2011
  • 현재까지 시공된 사장교 중, 주경간이 가장 긴 교량은 중국의 수통대교(1088m)이다. 이에 버금가는 사장교로 홍콩의 스톤커터교(1018m) 역시 주경간장이 1000m가 넘는다. 바야흐로 사장교 역시 주경간 1000m의 시대가 열린 것이다. 우리나라 역시 세계적 흐름에 맞추어 주경간 800m의 인천대교(세계 5위)를 시공한바 있다. 이와 같이 교량의 초장대화는, 교량 건설 분야에서 기술경쟁력의 지표가 될 뿐만 아니라 세계 건설 시장의 큰 흐름이라고 할 수 있다. 이에 본 연구는 세계적 추세에 발맞추어, 국내 각계의 건설 전문가들이 모여 만든 초장대 교량 사업단의 기술 혁신 사업의 일환으로 이루어졌다. 교량이 장대화 되면서 바람의 의한 영향이 중요해진다는 것은 주지의 사실이다. 특히 사장교와 현수교 같은 특수 교량의 경우, 정적 및 동적 내풍 성능이 반드시 고려되어야만 한다. 본 연구에서는 주경간 1200m의 사장교를 가정하고, 이 사장교의 내풍 단면을 개발, 그 단면에 대한 정적 및 동적 내풍 성능을 평가하고자 하였다. 정적 내풍 성능으로는 단면의 형상에 따른 풍하중을 파악하고자 했으며, 동적 내풍 성능으로는 풍속에 따른 교량의 연직방향 변위 및 플러터 속도를 파악하고자 하였다. 이 실험은 추후에 3차원 전교모형실험의 기본 데이터로 활용하였다. 본 실험을 통해 개발된 단면의 등류 및 난류 상태에서의 영각별 정적 공기력계수를 계산해내었고, 설계풍속이 54.7m/s일때 한계풍속 65.64m/s(거마대교 기준)하에서의 중앙 경간의 풍속별 평균 변위를 측정하였으며, 이를 토대로 이 교량의 영각별 플러터 속도를 계산해 내었다.

  • PDF

Experimental Study on Static Behavior of Laterally Strengthened Spliced Prestressed Concrete Girder using Bending Moment Connector (휨연결재에 의해 횡방향으로 보강된 분절 프리스트레스트 거더의 정적거동에 관한 실험적 연구)

  • Kim, Jae Heung;Kim, Jang-Ho Jay;Kim, Sung Bae;Yi, Na Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.287-295
    • /
    • 2010
  • The main purpose of this study is to investigate the static behavior of spliced prestressed concrete girder with bending moment connector and lateral prestressing. Four (4) spliced girders and one (1) monolithic girder had been fabricated and tested to compare their static behaviors. Same geometry and materials are used to fabricate these spliced and monolithic girders. A monolithic girder and one (1) spliced girder without lateral bending connector are used as control specimens to estimate the performance of three (3) spliced girders with lateral bending connector. Deflections at the middle of girders have been measured for evaluation. Also, strains of the concrete at the middle of span and connection points have been measured. It was found from the result that laterally strengthened spliced girders showed improved ultimate strength but less stiffness compared to the monolithic girder at the ultimate state. Laterally strengthened spliced girder also showed improved strength as well as improved stiffness compared to the spliced girder without lateral strengthening.

A Study on the Hydrophone using the multimode Fiber-optic Microbending (다중모드 광섬유 마이크로벤딩을 이용한 하이드로폰에 관한 연구)

  • 김경복
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1985.10a
    • /
    • pp.31-36
    • /
    • 1985
  • 본 논문에서는 그레이더드인덱스 다중모드 광섬유에 압력을 가함으로써 발생되는 마이크로벤딩을 모드 결합 이론으로 분석하고, 그 이론에 의해 모드결합이 최적으로 일어나는 정적벤딩을 통한 주기성을 얻어 시제품 광섬유 음향 트렌스튜서를 설계 및 그것을 이용한 광섬유음향센서를 제작하였다. 제작된 트랜스튜서의 탐지가능한 최소검출압력을 정적벤딩 실험을 통하여 계산하였으며 아울러 제작된 광섬유음향트랜스듀서의 특성을 실험하였다.

  • PDF