• Title/Summary/Keyword: 정량주유

Search Result 9, Processing Time 0.022 seconds

Quantitative analysis for mixing of fuel and air in burner systems (Burner 내 연료와 공기 혼합에 대한 정량적 해석)

  • 유영돈;정석우;신현동
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.56-61
    • /
    • 1995
  • 균일한 속도를 갖는 주유동장에 연료를 분사하였을때 분사된 연료가 주유동장의 공기와 혼합되는 정도를 정량적으로 설명하기 위하여 실험과 수치 계산을 실시하였다. 본 연구에서는 혼합 진전 정도를 나타내기 위하여 혼합진전변수(mixing progress variable)를 도입하여 유동조건에 따라 혼합 정도를 정량적으로 비교하였다. 주유동 속도가 일정할때 분사 속도를 증가시키면 연료가 주유동장의 공기와 혼합이 촉진됨을 알 수 있었다.

  • PDF

A implementation of system which checks the vehicle oil identification and quantitative gas (자동차 석유 및 정량주유 체크 시스템의 구현)

  • Jeong, Da-Woon;Baek, Sung-Hyun;Jang, Jong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.6
    • /
    • pp.1277-1282
    • /
    • 2011
  • Recently, many car drivers were damaged by gas station which support similar oil product and not quantitative gas. It were expected to increase above-mentioned damages. By using similar oil products, caused damage are working of lubrication in the fuel line, elf-cleaning function, the part of the early deterioration, impure accumulation in the fuel line, toxicity material in exhaust emissions and unidentified chemical reaction. To prevent these damages, proposed system use in-vehicle state data with OBD-II protocol, measure quantitative gas and similar oil. In this paper, there have implemented similar oil identification and quantitative gas system through OBD-II scanner to provide WiFi communcation by using WinCe development Board.

A design and implement vehicle similar oil identification and quantitative gas (자동차 유사석유제품 및 정량주유 판별 시스템의 설계 및 구현)

  • Jeong, Da-Woon;Baek, Sung-Hyun;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.281-284
    • /
    • 2011
  • Recently, many drivers was the damage caused by similar oil product sales and gas station by not using quantitative gas. so, these damages is expected to rise damages by increasing these problem. By using similar oil products, caused damage in the fuel lines' working of lubrication and self-cleaning function for the occurred trouble in the part of the early obsolescence and the accumulation of impurities in the fuel lines, combustion rate due to the difference between retail gasoline engine, the burden of weight, Toxic substances in exhaust emissions, engine oil and unresolved issue is the chemical reaction can occur. to prevent these damages, using the system use in-vehicle state data with OBD-II protocol and measure quantitative gas and similar oil. In this paper, there implement similar oil identification and quantitative gas system through OBD-II scanner to provide WiFi communcation by using WinCe development Board.

  • PDF

A Study on Facility Criteria of Small Petrol Stations based on Quantitative Risk Assessment (정량적 위험성 평가에 기반한 간이 주유취급소 시설기준에 대한 연구)

  • Park, Wooin;Ku, Jae-Hyun;Song, Yong-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.44-52
    • /
    • 2014
  • Small petrol stations have great potential for a wide distribution in metropolitan area in which the land value possesses primary installation cost of the facility. The objective of the present study is to propose appropriate facility regulations of small petrol stations in Korea that can be popularly installed in the future in terms of securing safety in addition to serviceability. The hazard analysis and damage prediction from the possible fire and explosion accidents were performed using a software, PHAST v.6.5. As essential components of the facility regulations proposed in this study, the regulations about the refueling lot, maximum capacity of underground tank, location of fixed refueling facilities, height of firewall for small petrol stations were subsequently compared with those for regular-sized petrol stations.

Development of monitoring system and quantitative confirmation device technology to prevent counterfeiting and falsification of meters (주유기 유량 변조방지를 위한 주유기 엔코더 신호 펄스 파형 모니터링 및 정량확인 시스템 개발)

  • Park, Kyu-Bag;Lee, Jeong-Woo;Lim, Dong-Wook;Kim, Ji-hun;Park, Jung-Rae;Ha, Seok-Jae
    • Design & Manufacturing
    • /
    • v.16 no.1
    • /
    • pp.55-61
    • /
    • 2022
  • As meters become digital and smart, energy data such as electricity, gas, heat, and water can be accurately and efficiently measured with a smart meter, providing consumers with data on energy used, so that real-time demand response and energy management services can be utilized. Although it is developing from a simple metering system to a smart metering industry to create a high value-added industry fused with ICT, illegal counterfeiting of electronic meters is causing problems in intelligent crimes such as manipulation and hacking of SW. The meter not only allows forgery of the meter data through arbitrary manipulation of the SW, but also leaves a fatal error in the metering performance, so that the OIML requires the validation of the SW from the authorized institution. In order to solve this problem, a quantitative confirmation device was developed in order to eradicate the act of cheating the fuel oil quantity through encoder pulse operation and program modulation, etc. In order to prevent the act of deceiving the lubricator, a device capable of checking pulse forgery was developed, manufactured, and verified. In addition, the performance of the device was verified by conducting an experiment on the meter being used in the actual field. It is judged that the developed quantitative confirmation device can be applied to other flow meters other than lubricators, and in this case, accurate measurement can be induced.

A Study on Damage Assessment for Fuel Cell Facilities in Gas Stations (주유소 내 연료전지설비에 대한 사고피해예측 연구)

  • Sung Yoon Lim;Jang Choon Lee;Jae Hoon Lee;Seung Ho Choi
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.1
    • /
    • pp.71-80
    • /
    • 2023
  • Fuel cells are low-carbon power sources that can expand distributed energy system and electric vehicle charging infrastructure when installing fuel cells in gas stations. In order to ensure safety for fuel cells in gas stations, quantitative risk assessments were conducted after deriving accident scenarios based on accident data of domestic and foreign gas stations and fuel cells. It calculates the expected extent of damage from fire and explosion that can occur in reality, not the worst accident scenario, and analyzes the damage impact. The separation distance of more than 9.0 m from a dispenser, 15.5 m from a car under refueling, 4.1 m from the ventilation pipe, 1.1 m from the gas adjustment device prevent the severe damage caused by the expected accident. This study result can be used to deploy fuel cells in gas stations and establish safety measures.

The Optimization and Verification of an Analytical Method for Sodium Iron Chlorophyllin in Foods Using HPLC and LC/MS (식품 중 철클로로필린나트륨의 HPLC 및 LC/MS 최적 분석법과 타당성 검증)

  • Chong, Hee Sun;Park, Yeong Ju;Kim, Eun Gyeom;Park, Yea Lim;Kim, Jin Mi;Yamaguchi, Tokutaro;Lee, Chan;Suh, Hee-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.148-157
    • /
    • 2019
  • An optimized analytical method for sodium iron chloriphyllin in foods was established and verified by using high performance liquid chromatography with attached diode array detection. An Inertsil ODS-2 column and methanol-water (80:20 containing 1% acetate) as a mobile phase were employed. The limit of detection and quantitation of sodium iron chloriphyllin were 0.1 and 0.3 mg/kg, respectively, and the linearity of calibration curve was excellent ($R^2=0.9999$). The accuracy and precision were 93.9~104.95% and 2.0~7.7% in both inter-day and intra-day tests. Recoveries for candy and salad dressing were ranged between 93 and 104% (relative standard deviation, (RSD) 0.3~4.3%), and between 83 and 115% (RSD 1.2~2.0%), respectively. Liquid chromatography mass spectrometry was used to verify the main components of sodium iron chlorophyllin which were Fe-isochlorin e4 and Fe-chlorin e4.

Comparative anatomy of petiole in Forsythieae, Fontanesieae and Myxopyrum (Oleaceae) and its systematic implication (개나리족, 향선나무족, Myxopyrum속(물푸레나무과) 엽병의 해부학적 형질 및 분류학적 유용성)

  • Song, Jun-Ho;Hong, Suk-Pyo
    • Korean Journal of Plant Taxonomy
    • /
    • v.42 no.1
    • /
    • pp.50-63
    • /
    • 2012
  • A comparative study of the petiole anatomy in the tribes Forsythieae (Abeliophyllum, Forsythia) and Fontanesieae (Fontanesia), including one related genus Myxopyrum belonging to Myxopyreae, was carried out using light microscopy. The anatomical characteristics of the distal, medial and proximal parts of the petiole were studied to document any differences. We are described in detail based on their quantitative and qualitative characteristics. Three crystal types (acicular, druse, and prismatic crystals) were found in both Fontanesia and Myxopyrum within all of the studied taxa. Uni-cellular non-glandular trichomes were found in Abeliophyllum and three Forsythia taxa (F. europaea, F. giraldiana, and F. japonica). All features were compared and the vascular patterns of the petiole were distinguished in two types: Type 1A: Trace continuous arc - without crystals (Abeliophyllum, Forsythia), 1B: with crystals (Myxopyrum), Type 2: Trace invaginating at ends with crystals (Fontanesia). A detailed anatomical description of the studied taxa is provided, and its systematic importance is also briefly discussed. In conclusion, some petiole anatomical characteristics (e.g., the main vascular patterns, the presence/absence of crystals) can be useful for diagnostic features as well as partly for supporting the recently proposed molecular phylogeny.

A Study on the Selection of Hydrogen Refueling Station Locations within Military Bases Considering Minimum Safe Distances between Adjacent Buildings (인접 건물 간 최소 안전거리를 고려한 군부대 내 수소충전소 위치선정 연구)

  • Dong-Yeon Kim;Hyuk-Jin Kwon
    • Journal of Internet Computing and Services
    • /
    • v.24 no.6
    • /
    • pp.171-180
    • /
    • 2023
  • Hydrogen energy technology is gaining importance in the era of the Fourth Industrial Revolution, offering military advantages when applied to military vehicles due to its characteristics such as reduced greenhouse gas emissions, noise, and low vibration. Korea's military has initiated the Army Tiger 4.0 plan, focusing on hydrogen application, downsizing, and AI-based smart features. The Ministry of National Defense plans to collaborate with the Ministry of Environment to expand hydrogen charging stations nationwide, anticipating increased deployment of military hydrogen vehicles. However, considering the Jet Fire and VCE(Vapor Cloud Explosion) nature of hydrogen, ensuring safety during installation is crucial. Current military guidelines specify a minimum safety distance of 2m from adjacent buildings for charging stations. Scientific methods have been employed to quantitatively assess the accident damage range of hydrogen, proposing a minimum safety distance beyond the affected area.