• Title/Summary/Keyword: 정기용

Search Result 576, Processing Time 0.028 seconds

Analytical method of the polychlorinated biphenyls in soil using GC/ECD and GC/MS (GC/ECD 및 GC/MS을 이용한 토양 중 PCBs 분석방법 고찰)

  • Kim, Tae-Seung;Shin, Sun-Kyoung;Yoon, Jeong-Ki;Kim, Jong-Ha;Kim, Hyoung Seop;Lee, Jeong Ah
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.91-108
    • /
    • 2007
  • This study was investigated both the Korean official soil test method and the international various methods for PCBs in soil sample. The analytical guideline of PCBs in contaminated soil were proposed based on the official soil test methods by discussing the extraction, column cleanup, instrumental conditions, quantification methods of peak matching and individual isomers. The total 28 soil samples were selected by consideration of PCBs-contamination, land use etc., and then analyzed using gas chromatography/electron capture detection (GC/ECD) and gas chromatography/mass spectrometry(GC/MS). In this study, the PCBs were not detected as peak matching method using GC/ECD, but PCBs detected $0.002{\sim}0.487{\mu}g/kg$ using GC/MS in background concentrations.

Structural Design of SAR Control Units for Small Satellites Based on Critical Strain Theory (임계변형률 이론에 기반한 초소형 위성용 SAR 제어부 전장품 구조설계)

  • Jeongki Kim;Bonggeon Chae;Seunghun Lee;Hyunung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.2
    • /
    • pp.12-20
    • /
    • 2024
  • The application of reinforcement design to ensure the structural safety of electronics in small satellites is limited by the spatial constraints of the satellite structure during launch vibrations. Additionally, a reliable evaluation approach is needed for mounting highly integrated devices that are susceptible to fatigue failure. Although the Steinberg fatigue failure theory has been used to assess the structural integrity of electronic devices, recent studies have highlighted its theoretical limitations. In this paper, we propose a structural methodology based on the critical strain theory to design the digital control unit (DCU) of the X-band SAR payload component for the small SAR technology experimental project (S-STEP), a small satellite constellation. To validate the design, we conducted modal and random analyses using simplified modeling techniques. Based on our methodology, we ultimately demonstrated the structural safety of the electronics through analysis results, safety margin derivation, and functional tests conducted both before and after the launch test.

Effects of Growth Performance and Carcass Characteristics by Fermented Barley Grain Feeding in Post-fattening Hanwoo Steers (거세한우 비육후기 보리곡실 발효사료 급여에 따른 성장과 도체특성에 미치는 효과)

  • Chang, Sun-Sik;Kwon, Eun-Ki;Lee, Eun-Mi;Hwang, So-Mi;Cho, Sang-Rae;Kim, Ui-Hyoung;Chung, Ki Yong
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.4
    • /
    • pp.235-242
    • /
    • 2019
  • The purpose of this study was to investigate the proper feeding level and duration of fermented barley grain feed before harvesting to improve the availability of barley for feed. Trial 1 was to investigate the proper feeding amount of fermented barley grain fermented feed, and we prepared 32 heads (603.4 ± 42.7kg) of 22-month-old Hanwoo steer (603.4 ± 42.7kg) for 8 heads in 4 treatment groups. 48 heads (625.8 ± 13.1kg) for Trial 2 were used for 12heads per 4 treatments, and were reared for about 9 months until 30 months of age. Trial 1 is treated a Control group that feed 10㎏ of concentrate, replaces 10% fermented barley grain feed(FBGF) of the control by (TRT 1) and 20% (TRT 2) and 30%(TRT 3). Concentrate and FBGF fed 9, 2.1 kg, 8, 4.2 kg, 7 and 7, 6.3 kg on each treatments respectively and 1.5 kg of rice straw for forage. In Trial 2, 10% of alternative diets were judged to be appropriate, and the control of 9kg of diets and barley grain fermented feeds were used to determine the appropriate feeding period. The treatments were 3 months before shipment (TRT 1), 6 months (TRT 2) and 9 months (TRT32). Each treatment group had 8 and 2.1 kg of concentrate and barley grain fermentation, respectively. As a feed, rice straw was fed to 1.5 kg. The daily gains per treatment were higher in TRT 1 and TRT 3 was similar to the Control. Body weight and daily gain during the test period were higher in TRT 1 fed 10% barley grain fermented feed. TRT 2 was the highest at 6.13, and TRT 3 was 6.0, which was higher than 5.63 of TRT 1 and 5.5 of Control.

고감도 형광판을 이용한 실시간 IMRT 선량 분석 가능성 연구

  • 고영은;이병용;안승도;이상욱;김종훈;신성수;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.36-36
    • /
    • 2003
  • 목적 : 고감도 형광판과 필름을 이용하여 실시간으로 선량을 측정하여 IMRT 선량분포를 검증하는데 사용하는 가능성을 알아보고자 하였다. 대상 및 방법 : 본 연구에서 개발한 물팬텀은 지름 25cm 아크릴 원통과 원통의 중앙부분에 삽입되는 고감도 형광판으로 구성되어 있다. 이를 사용하여 dose linearity correction factor를 구하기 위해 dmax 지점에서 6MV x-ray를 고감도형광판에 조사하여 blurring correction factor를 구하였다. CCD를 이용하여 고감도 형광판에서 나오는 영상을 수집하였다. 고감도 형광판에서 수집한 영상의 x축 profile은 RTP에서 얻은 profile과 비교하였고, 이온전리함으로 scanning한 데이터를 이용하여 고감도 형광판과 물에서 빛에 의한 산란선 때문에 발생하는 blurring effect를 교정하였다. 여기서 계산된 blurring effect factor를 고감도 형광판에서 수집된 영상에 적용하였다. 결과 : CCD 카메라는 형광판의 전 영역을 감지할 수 있고, 조사시간은 형광판의 중첩된 영상의 선량에 비례하였다. 물팬텀에서 형광판의 blurring effect 는 가우시안 분포로 표현할 수 있었다. 또한 Deconvolution kernel은 원통 팬텀에서 지름 $\pm$5cm 이내의 범위에 위치하였고, 따라서 형광판 영상으로부터의 실제 선량분 포를 뽑아낼 수 있었다. RTP 에서 계산된 선량분포와 blurring correction factor로 교정한 후 중첩시켜 얻은 고감도 형광판 영상의 선량분포는 일치하였다. 결론 : 정기적인 IMRT 선량 검증에 대한 실시간 선량측정 방법이 개발되었다. 고감도 형광판 영상과 CCD 카메라를 사용한 물팬텀으로, IMRT 치료계획에 대한 선량분포를 검증할 수 있는 가능성을 보였다.비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.tokines의 변화는 비록 통계학적인 차이는 없지만 비타민 C를 사용한 환자의 cytokines이 모두 사용하지 않은 환자에 비해 감소하였음을 보였다. 비타민 C는 부작용이 거의 없는 안전한 약으로서 말기 암 환자에서 비타민 C사용은 임상 증상을 호전시키는 데 도움

  • PDF

Sterilizing and Deodorizing Effect of UV-Ray Air Cleaner for Refrigerator (자외선(紫外線) 공기(空氣) 청정기(淸淨機)의 냉장고(冷藏庫) 살균(殺菌) 탈취(脫臭) 효과(效果))

  • Chun, Jae-Kun;Lee, Yung-Jin;Kim, Kyung-Man;Lee, Hong-Won;Jang, Eu-Yung
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.174-177
    • /
    • 1993
  • Ultara violet ray air cleaner to use as the sterilization and deodorization device in refrigerator was designed and made of UV lamp and carbon block as the main components. The intensity of the lamp was $2.38\;mW/cm^2$ and reflector was installed to increase the radation. After running the device for 12 hours, 80% of the population of airborn bacteria was sterilized both at 48 and 480 liter refrigerator chambers. Ozone production caused by UV-ray reached 0.082 ppm at holding section within a few second when the device was operated at $25^{\circ}C$ and it showed 0.06 pm at $3^{\circ}C$. Deodorization effect was 2.5 times greater than that of a device made of electrical are principle at $25^{\circ}C$. New device 2 times more effectivly decreased trimethylamine and methyl mercaptan content applied as odor indicator substance in chamber at $3^{\circ}C$ than electrical arc type.

  • PDF

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF

Evaluation of Preservative Efficiacy for Refractory Wood Species in Field Tests and Its Implication for Korean Wood Preservation Industry (야외시험을 통한 난주입수종의 방부성능 평가 및 국내 목재보존산업에서의 시사점)

  • Ra, Jong Bum;Ingram, Janet;Wang, Jieying;Morris, Paul I.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.544-558
    • /
    • 2017
  • The objective of this research is to investigate preservative efficacy for refractory species in field tests. The field tests were set up to evaluate the preservative performance of western hemlock and white spruce preservative-treated to the residential products group C and D of Canadian standard (CSA O80 Series-08) that have been developed for residential use in above-ground and ground-contact conditions, respectively. They were incised and pressure-treated with alkaline copper quaternary (ACQ) or copper azole (CA). Treated samples for the ground contact stake test and ground proximity test were installed in Jinju, Korea on November 2010 according to AWPA E7-09 and AWPA E18-06, respectively. Each sample has been annually assigned ratings for decay and termite attack, based on AWPA E7 grading system. After six years and five months of exposure, the untreated samples showed decay and particularly severe damage by termite attack but all the preservative-treated samples showed no decay. The results showed that the 5-mm penetration depths may be applicable for the treatment of refractory species. This paper discusses what to consider for the use of refractory species in Korean wood preservation industry from the penetration and retention points of view.

Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery (방사선수술용 4뱅크 마이크로 다엽콜리메이터의 인수 검사)

  • Jeong, Dong-Hyeok;Shin, Kyo-Chul;Kim, Jeung-Kee;Kim, Soo-Kon;Moon, Sun-Rock;Lee, Kang-Kyoo
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • The 4 bank mico-MLC (mMLC; Acculeaf, Direx, Isral) has been commissioned for clinical use of linac based stereotactic radiosurgery. The geometrical parameters to control the leaves were determined and comparisons between measured and calculated by the calculation model were performed in terms of absolute dose (cGy/100 MU). As a result of evaluating calculated dose for various field sizes and depths of 5 and 10 cm in water in the geometric condition of fixed SSD (source to surface distance) and fixed SCD (source to chamber distance), most of differences were within 1% for 6 MV and 15 MV x-rays. The penumbral widths at the isocenter were approximately evaluated to 0.29~0.43 cm depending on the field size for 6 MV and 0.36~0.51 cm for 15 MV x-rays. The average transmission and leakage for 6 MV and 15 MV x-rays were 6.6% and 7.4% respectively in single level of leaves fully closed. In case of dual level of leaves fully closed the measured transmission is approximately 0.5% for both 6 MV and 15 MV x-rays. Through the commissiong procedure we could verify the dose characteristics of mMLC and approximately evaluate the error ranges for treatment planning system.

  • PDF

Study for Multi Channel Radiation Detector Using of Microfilm and Carbon Electrode (탄소막 마이크로필름을 이용한 다채널 전리함 개발에 관한 연구)

  • Shin Kyo Chul;Yun Hyong Geun;Jeong Dong Hyeok;Oh Yong Kee;Kim Jhin Kee;Kim Ki Hwan;Kim Jeung Kee
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.111-115
    • /
    • 2005
  • We have designed the multi channel detector for the quality assurance of clinical photon beams. The detector was composed of solid phantom inserted by six plane-parallel ionization chambers at different depth. The chamber as a mini plane parallel chamber was made of carbon coated microfilms. In this study the electrical characteristics of the six chambers in the solid phantom were evaluated using 6 MV photon beam. The leakage currents were less than 0.5 pA, reproducibility was less than 0.5$\%$, linearity was less than 0.5$\%$, and dose rate effect was less than 0.7$\%$. In addition the effect of dose variation from other chambers was estimated to maximum 0.8$\%$ approximately. The developed detector can be used for quality determination in output dosimetry or measurement of percentage depth dose approximately for clinical photon beam.

  • PDF

Constructed Mobile System for Management affair of Water & sewage Facilities (상하수도 유지관리업무를 위한 모바일 시스템 구축)

  • Lee, Hyun-Jik;Park, Ki-Suk;Ru, Ji-Ho
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.3 s.30
    • /
    • pp.69-78
    • /
    • 2004
  • Since 1995, One of the NGIS(National Geographic Information System) projects, the underground utilities project, has been finished in 2003. The 19 cities in korea for this project will use underground utilities management system using underground utilities database focusing on water and sewage system. However, special expert, technical and experience problem in computer environment has not been had in working department for water and sewage management and maintenance for each local government. The management and maintenance by underground utilities database by manual method is getting lowered a data qualify of underground utilities database because of the data omitting, error in writing and securing of the lasted database. Therefore, in this study, Application test for field workers using a mobile tool and environment analysis of wireless communication in Korea and application test of GPS receiver for mobile tools had been processed and made a mobile working environment. The efficient management and maintenance method for underground utilities database has been developed an off-line method for modification and update of database about general work which has a high working frequency because of the limitation of wireless communication environment. Also, the emergency working has been applied for on-line method.

  • PDF