• Title/Summary/Keyword: 접합불량

Search Result 59, Processing Time 0.027 seconds

A Stereo Matching Method for Photogrammetric Orientation (사진측량의 표정을 위한 스테레오 매칭 방법)

  • 최재화;박희주;서용운
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.14 no.1
    • /
    • pp.9-16
    • /
    • 1996
  • A new stereo matching method for the relative orientation and the photogrammetric triangulation has been pro-posed. It matches the pairs of conjugate points to be used as pass points and tie points in digital aerial photographs instead of selecting these points with manual point transfer and measurements. Three unique steps included in the proposed matching method are as followings. The first step is searching interest points, and designating them as candidate points to be matched. The second is matching the points from the pair of images by the Cross Correlation Method in both direction(left to right direction and right to left). The third is selecting consistent pairs in the both matching directions. Computer programs based on the proposed matching method have been developed, and with digital aerial photographs which have full ground coordinate information tests were performed to know reliabiliy and positional accuracy of proposed method. Results of the tests reveal that the proposed matching method can eliminate the in-correctly matched pairs more efficiently than other matching methods, thus this can be more reliably applied to the relative orientation and the photogrammetric triangulation.

  • PDF

Thermal Fatigue Failure of Solder Joints in Electronic Systems (미세솔더접속부의 열피로파단)

  • 박화순
    • Journal of Welding and Joining
    • /
    • v.13 no.4
    • /
    • pp.7-13
    • /
    • 1995
  • 마이크로솔더링에 의한 전자기기는, 사회기능의 중추가 되는 컴퓨터, 통신 기기, 항공기 인공위성 등의 제어계를 구성하므로, 그 접속부에 대한 높은 신뢰성의 요구는 그 무엇보다 중요하다. 전자기기에 있어서의 솔더 접속부는 집과 기판의 전기 적.기계적 접속의 역할을 하고 있으며, 따라서 개개의 접속부의 파단은 전체의 불량 으로 연결된다. 실제 전자콤포넌트와 그 시스템의 단선 등의 사고에 있어서 자주 발생 하는 사고중의 하나가 솔더접속부의 단선에 의한 것이며, 그 단선중에서도 가장 보편 적이며 또한 대단히 심각한 문제로서 주목을 받고 있는 것이 솔더접속부의 열피로파단 이다. 전자기기를 사용할 때, 스위치의 on-off에 의한 power cycle과 환경의 온도변화 에 기인하는 반복열 사이클은 솔더접속부의 피로를 일으키게 되고, 결국에는 사용중에 파단을 초래하게 된다. 이러한 온도변화의 범위는 약 -55.deg. - 150.deg.C로 예상할 수 있으며, 여기서 최고온도인 150.deg.C는 Pb-Sn 공정합금의 경우 0.9Tm.p.이상의 고온에 해당한다. 이 피로는 등온적으로 또는 열사이클중에 발생하기도 한다. 솔더접 속부의 열피로수명은 대부분의 공업재료에서 나타나는 저사이클피로거동과 유사하게 발생하며, 솔더 접속부에 인가되는 열변형/응력(thermal strain/stress)의 크기에 크게 의존하는 것으로 알려져 있다. 솔더는 서로 다른 열팽창계수를 갖는 칩과 회로 기관의 두종류의 재료를 접속하기 때문에, 상기한 바와 같은 반복열사이클에 의하여 발생하는 열변형/응력이 접속부의 피로.파단을 야기시킨다. 이러한 솔더접속부에 대한 주기적인 응력/변형의 인가는 접속부에 내.외적으로 현저한 변화를 야기시키게 되고, 열피로로 연결되며 결국에는 시스템의 전기적 단선을 초래하게 된다. 또한 열피로파단 현상는 변형/응력의 크기 뿐 만아니라 솔더합금자체의 야금학적인 물성에도 크게 의존 하며, 내적.외적인 열변화에 의한 야금학적인 특성변화도 크게 영향을 미친다. 솔더 접속부의 신뢰성에 대한 연구는, 그 중요성에 비추어 볼 때, 지금까지 수많은 연구가 행하여져 왔다. 그러나 신뢰성과 관련된 열피로파단현상에 대한 야금학적인 면에서의 연구는 비교적 적은 편이다. 따라서 본 해설에서는 전자기기의 마이크로 솔더접속부 에서 발생하는 열피로파단현상에 대한 야금학적인 면에 중점을 두어 서술하고자 한다.

  • PDF

Development of 3-D Flow Model for Porous Media with Scenario-based Ground Excavation (지반굴착 시나리오 기반의 다공성 매질에 대한 3차원 유동해석모델 구축)

  • Cha, Jang-Hwan;Lee, Jae-Young;Kim, Woo-Seok
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.19-27
    • /
    • 2017
  • In recent years, ground subsidence has been frequently occurred by underground cavities due to the excessive groundwater inflow, caused by poor construction and management, during tunnel excavation and underground structure construction. In this study, a numerical model (SEEFLOW3D) was developed to estimate groundwater fluctuations for saturated-unsaturated poros media, evaluates the impact on ground excavation with open cut and non-open cut scenarios. In addition, the visual MODFLOW was applied to demonstrate the verification of the model compared with both results. Our results indicated that the RMSE and NRMSE was obtained to range over -3.95~5.7% and 0.56~4.62%, respectively. The developed model was expected to estimate groundwater discharges and apply analysis tool for optimum design of waterproof wall in future.

Evaluation on the Appearance and Gluing Characteristics of Pine Laminated Boards according to Overlaying Materials (소나무 집성판의 표면화장 재료별 외관품질 및 접착성 평가)

  • So, Won-Tek
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.27-35
    • /
    • 2007
  • This experiment was carried out to investigate the appearance and surface gluing characteristics of laminated boards overlaied with teak sliced veneer, printing paper, wall paper, cotton cloth, and wool cloth, The overlaying sheets were glued on the laminated boards with polyvinyl acetate emulsion adhesives and the species for laminated boards was red pine. The obtained results are summarized as follows; in case of the teak sliced veneer overlaied boards, the appearance quality was very good and showed the first grade of KS standard. but the delamination rate was 44.0% and 895% for cold water or warm water dipping treatments, respectively, so the wet gluing properties were very bed. In the case of the paper or cloth overlaied boards, the appearance quality was same good and showed the first grade of KS standard, but their delamination rate was 10~20% and 39.3~49.0 for cold water or warm water dipping treatments, respectively, so the wet gluing properties were bed, relatively better than sliced veneer overlaied boards. The present work showed that appearance of laminated boards overlaid with several sheets appeared quite positive in terms of secondary gluing qualities of laminated boards, suggesting that sliced veneer, paper, and cloth would be appropriate for the overlaying materials of laminated boards.

Development of an Automatic Grafting Robot for Fruit Vegetables using Image Recognition (영상인식 기술 이용 과채류 접목로봇 개발)

  • Kang, Dong Hyeon;Lee, Si Young;Kim, Jong Koo;Park, Min Jung;Son, Jin Kwan;Yun, Sung-Wook
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.322-327
    • /
    • 2019
  • This study was conducted to improve the performance of automatic grafting robot using image recognition technique. The stem diameters of tomatoes and cucumber at the time of grafting were $2.5{\pm}0.3mm$ and $2.2{\pm}0.2mm$ for scions and $3.1{\pm}0.7mm$ and $3.6{\pm}0.3mm$ for rootstocks, respectively. The grafting failure was occurred when the different height between scions and rootstocks were over 4 mm and below 2 mm due to the small contact area of both cutting surface. Therefore, it was found that the height difference at the cutting surface of 3 mm is appropriate. This study also found that grafting failure was occurred when the stem diameters of both scions and rootstocks were thin. Therefore, it was suggested to use at least one stem with thicker than the average stem diameter. Field survey on the cutting angle of stems by hand were ranged from 13 to 55 degree for scions and 15 to 67 degree for rootstocks, respectively, which indicates that this could cause the grafting failure problem. However, the automatic grafting robot developed in this study rotates the seedlings 90 degree and then the stems are cut using a cutting blade. The control part of robot use all images taken from grafting process to determine the distance between a center of both ends of stem and a gripper center and then control the rotation angle of a gripper. Overall, this study found that The performance of automatic grafting robot using image recognition technique was superior with the grafting success rates of cucumber and tomato as $96{\pm}3.2%$ and $95{\pm}4%$, respectively.

Effect of Aspect Ratio and Diagonal Reinforcement on Shear Performance of Concrete Coupling Beams Reinforced with High-Strength Steel Bars (세장비 및 대각철근 유무에 따른 고강도 철근보강 콘크리트 연결보의 전단성능)

  • Kim, Sun-Woo;Jang, Seok-Joon;Yun, Hyun-Do;Seo, Soo-Yeon;Chun, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.43-51
    • /
    • 2017
  • As per current seismic design codes, diagonally reinforced coupling beams are restricted to coupling beams having aspect ratio below 4. However, a grouped diagonally reinforcement detail makes distribution of steel bars in the beam much harder, furthermore it may result in poor construction quality. This paper describes the experimental results of concrete coupling beam reinforced with high-strength steel bars (SD500 & SD600 grades). In order to improve workability for fabricating coupling beams, a headed large diameter steel bar was used in this study. Two full-scale coupling beams were fabricated and tested with variables of reinforcement details and aspect ratio. To reflect real behavior characteristic of the beam coupling shear walls, a rigid steel frame system with linked joints was set on the reaction floor. As a test result, it was noted that cracking and yielding of reinforcement were initially progressed at the coupling beam-to-shear wall joint, and were progressed to the mid-span of the coupling beam, based on the steel strain and failure modes. It was found that the coupling beams have sufficient deformation capacity for drift ratio of shear wall corresponding to the design displacement in FEMA 450-1. In this study, the headed horizontal steel bar was also efficient for coupling beams to exhibit shear performance required by seismic design codes. For detailed design for coupling beam reinforced with high-strength steel, however, research about the effect of variable aspect ratios on the structural behavior of coupling beam is suggested.

Application of SP Survey and Numerical Modeling to the Leakage Problem of Irrigation facilities (수리시설물 누수탐지에 대한 자연전위법 적용 및 수치 해석)

  • Song Sung-Ho;Kwon Byung-Doo;Yang Jun-Mo;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.257-261
    • /
    • 2002
  • We have carried out integrated research including field survey and numerical modeling to appraise the applicability of SP method to the leakage problems of irrigation facilities. The leakage pattern of the dike studied here can be classified into the three categories: leakage through the abutment, leakage by piping through dike, and leakage due to the composite effects of landslide and distortion of the dike structure. for the numerical modeling to interpret quantitatively SP survey results acquired at dike, we have modified the computer code proposed by Sill (1983) to apply to the leakage problems. The numerical studies match the characteristic patterns of SP anomalies according to the leakage types and appear to be very useful to interpret the leakage zone and path. The SP monitoring results were also well coincided with tidal variations observed at every embankment so we found the SP method is quite effective not only to detect the leakage zone but also to determine the leakage trend. The numerical modeling results also reproduced the SP anomalies due to seawater leakage in the embankment.

Safety Factor of Rigid Sewer Pipe by Different Types of Foundation and Backfill (기초형식 및 뒤채움재 종류별 강성관용 하수관거의 안전율)

  • Lee, Kwan-Ho;Kim, Seong-Kyum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.606-612
    • /
    • 2019
  • The main causes of subsidence and sinkholes in the lower part of urban roads are sewage line foundation and inadequate compaction of backfill material. This leads to many problems, such as the breakage of joints in sewer pipes, poor connection, pipe breakage, and cracks. To solve this problem, the support factor related to the sewer foundation and the safety factor according to the excavation depth were evaluated. For the foundation of rigidity tolerance, crushed stone foundation, and abandoned concrete foundation, a recently newly developed site assembly-type lightweight plastic foundation were used. Backfill materials were applied on site (sandy soil and clayey soil) and fluid backfill was recycled onsite. To evaluate the depth of excavation and the safety factor of each sewer pipe foundation, the design load considering the load factor and the support factor was evaluated. The support coefficients were 0.377 for a crushed stone foundation, 0.243 and 0.220 for an abandoned concrete foundation ($180^{\circ}$ and $120^{\circ}$), and 0.231 for a lightweight plastic foundation and fluid backfill. Overall, the safety factor was low when using the crushed stone foundation, and the safety rate was the highest when the foreclosed concrete foundation ($180^{\circ}$) was used. In addition, when the combination of lightweight plastic and fluid backfill materials was used, the safety factor was higher than that of abandoned concrete foundation ($120^{\circ}$), which means that the newly developed lightweight plastic foundation can be used as another alternative base of a steel pipe.

An Experimental Study on the Evaluation of EMP Shielding Performance of Concrete Applied with ATMSM Using Zn-Al Alloy Wire (Zn-Al 합금 선재를 이용한 금속용사 공법 적용 콘크리트의 전자파 차폐 성능 평가에 관한 실험적 연구)

  • Choi, Hyun-Jun;Park, Jin-Ho;Min, Tae-Beom;Jang, Hyun-O;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.3
    • /
    • pp.209-217
    • /
    • 2019
  • EMP (Electromagnetic Pulse) usually means High Power Electromagnetic Wave (HPEM). In the case of the shielding plate against the EMP, there is a possibility of deterioration of the electromagnetic wave shielding performance due to the skill of the constructor, bad construction, deformation of the shielding plate at the connection portion (joint portion). The inefficient use of space due to the separation distance is also pointed out as a problem. Therefore, this study aims to derive the optimum electromagnetic shielding condition by applying ATMSM to concrete as a part of securing electromagnetic wave shielding performance with reflection loss against concrete wall. Experimental parameters included concrete wall thickness and application of Zn-Al ATMSM. For the concrete wall, the wall thickness was 100 to 300mm, which is generally applied, and experimental parameters were set for the application of Zn-Al metal spraying method to evaluate electromagnetic shielding performance. Experimental results showed that as the thickness increases, the electromagnetic shielding performance increases due to the increase of absorption loss. In addition, after the application of Zn-Al ATMSM, the average shielding performance increased by 56.68 dB on average, which is considered to be increased by the reflection loss of the ATMSM. In addition, it is considered that the shielding performance will be better than that when the conductive mixed material and the ATMSM are simultaneously applied.