• Title/Summary/Keyword: 전차선로

Search Result 249, Processing Time 0.025 seconds

Selection Criteria for the Traction Power Supply Line of the Light Rail Transit System (경량전철 전차선 용량 선정방법)

  • Chung S.G.;Jeong R.G.;Cho H.S.;Han S.Y.;Lee A.H.;Baek B.S.
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.409-414
    • /
    • 2003
  • In this study we examined the method to select the size of the conductor rail for light rail system. Study results shows that using the conductor rail with lower resistivity requires fewer power substation, which results in lower construction cost. It also produces less copper loss. Therefore first choose the conductor rail with lowest resistivity and select the substation location, Next conduct computer simulation study to confirm it meets voltage requirement. if the minimum voltage is well above the required minimum voltage, substation number can probably be further reduced.

  • PDF

Analysis of Temperature on Overhead Contact Line Using De-icing System (전차선 해빙시스템의 온도 상승효과)

  • Park Young;Kwon Samyoung;Jung Hosung;Cho Younghyun;Park Hyunjune;Lee Kiwon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.724-729
    • /
    • 2005
  • Winter weather condition can cause icing and ice coats on 25 kV overhead contact wire. This generates shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire and extra electrical resistance, which may affect quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing operations should he performed just before train operation to avoid the formation of another ice layer. Thus, the work in this paper is investigation and analysis of de-icing system which could be applied to the electric car line of railways.

  • PDF

Characteristics of Current Collection Signals during Test Run of High-speed Train (주행 중 발생하는 고속전철 집전계 신호의 특성)

  • 이시우;김정수;조용현;최강윤
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.3
    • /
    • pp.232-238
    • /
    • 2004
  • The dynamic characteristics of the current collection process of the high-speed railway are investigated through signals acquired during a test run. The signals are obtained from accelerometers, load cells, and strain gauges attached to various positions of the pantograph, and they are processed in time-and frequency-domains to obtain the dynamic characteristics. The main natural frequency of the pantograph is found to be 8.5Hz. There also are components at low frequencies varying linearly with the train speed. The contact frequency components above 20Hz is attenuated as they pass through the secondary suspension. The main frequency component of the load cell signal is found to be related with the rolling motion of the panhead generated by the stagger in the catenary.

Implementation of Image Monitoring system using High Speed Camera for Overhead Contact Wire (고속 카메라를 이용한 전차선 형상 검측 시스템 구현)

  • Cho, Hyeon-Young;Kwon, Sam-Young;Lee, Ki-Won;Park, Hyun-June;Na, Hae-Kyoung;Ko, Byeong-Hun;Park, Young
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1483-1487
    • /
    • 2006
  • In electric railway, image monitoring using high speed camera provides reliable, timely information of wear and geometry status, important in taking decisions for overhead contact wire maintenance. The contribution of this research is the development of a simple real-time monitoring system for use in measurement subsystem of contact wire and geometry of overhead contact wire in electric railway. The system has been consists of a high speed CMOS camera with resolution $1024{\times}1280$ pixels, line type laser source and PC-based image acquisition system with PCI Express slot. Vision acquisition software have been used in application programming interface for image acquisition, display, and storage with a frequency of sampling of 500 acquisitions per second.

  • PDF

Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System (교류전기철도 급전시스템의 전차선 전압해석)

  • 이승혁;정현수;김진오
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.490-496
    • /
    • 2002
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode far locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Finally, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

  • PDF

Reliability Analysis of Arcing Measurement System Between Pantograph and Contact Wire (팬터그래프-전차선간 아크 검측 장치의 신뢰성 분석)

  • Park, Young;Kwon, Sam-Young;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1216-1220
    • /
    • 2012
  • The current collection between pantograph and contact wire is a more critical component for need to train speed up in electric railway. The basic purpose of this paper is to establish a measure of determining arc by developing an arc detector assessment system. The system was designed under conditions of EN 50317 and simulations were conducted using the developed device. According to the results, it was possible to conduct certification tests following regulations of international standards. To check the validity of our approach for the intended application, we analysis contact loss of catenary system using developed arcing measurement system in Korea. The proposed arcing measurement system is expected to enhance precision of current collection quality performance assessment methods at high-speed lines and conventional lines.

A Study on an arc according to loss of contact between pantograph and catenary (판토그래프와 전차선 사이에서 발생되는 아크 특성에 관한 연구)

  • Lee, Bong-Yi;Kim, Jae-Chul;Han, Sung-Ho;Lee, Su-Gil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • Electric train is currently used widely, and much development is expected. But, in case of electric train, as comparison with diesel rolling stock, many electrical problem such as harmonic, voltage sag, EMI, EMC usually occur. Accordingly, in order to popularize an electric train, first, a study on electrical problem at an electric train must be accomplished. In this paper, one of electrical problems, arc characteristics according to loss of contact between pantograph and catenary was analyzed.

  • PDF

A Study on the Temperature Feature of Electric Car Line by the Climatic Change for the De-icing System (해빙시스템을 위한 기후변화에 따른 전차선 온도특성에 관한 연구)

  • Jung, Myung-Sub;Kim, Yong;Lee, Byung-Song;Kwon, Sam-Young;Jung, Ho-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.305-307
    • /
    • 2005
  • In the cold and temperate regions of Korea the icing and ice coats on 25[kV] electric car line during winter is a very serious problem. This generates shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire and extra electrical resistance, which may affect quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing operations should be performed just before train operation to avoid the formation of another ice layer. This paper presents temperature analysis of the de-icing system which could be applied to the electric car line of railways.

  • PDF

Dynamic Simulation for High-speed Pantograph and Overhead-line using a Vibration Mode Superposition Method (모드중첩법을 이용한 고속용 팬터그래프와 전차선의 동적 상호작용 시뮬레이션)

  • Cho, Yong-Hyeon;Lee, Ki-Won;Park, Hyun-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.494-497
    • /
    • 2004
  • A dynamic simulation for a high-speed pantograph-overheadline has been performed using mode superposition method to predict contact forces between pantograph and overheadline. We can deal with non-linear dampers of the pantograph and pre-sag of overhead-line for the simulation. But, we can not consider slackness of dropper in the overhead-line. According to the simulation results, the contact forces and displacements are reasonably predicted, compared with other foreign simulation results.

  • PDF

A Study on the Elasticity Disuniformity for Catenary using by Beam Model (빔 모델을 이용한 전차선 불균일율에 관한 연구)

  • 권삼영;이기원;조용현;정흥채
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.209-217
    • /
    • 1999
  • A catenary system should be designed to be an uniform elasticity over a span in order to maintain the lowest possible loss of contact between a pantograph and a contact wire. A elasticity disuniformity of a catenary can be regarded as a important design factor used for predicting the current collection performance for a catenary. There are a couple of formulas to calculate elasticity disuniformity of a catenary according to the literature survey, The effectiveness of these formulas is reviewed by performing catenary elasticity and loss of contact analysis for 5 different configurations of catenary systems using a beam element based FEM program, KRRI developed program, and the loss of contact by GASENDO, RTRI developed program, respective]y. The results reveals that these formulas are not suitable to predict the current collection performance for a catenary. Therefore, a new formula based on the standard deviation of the elasticity over a span is proposed in this study. The analysis results show that the new formula for an elasticity disuniformity of a catenary is very effective in predicting the current collection performance for a catenary.

  • PDF