• Title/Summary/Keyword: 전장검사

Search Result 22, Processing Time 0.019 seconds

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.

Shear bond strength of veneer ceramic and colored zirconia by using aqueous metal chloride solutions (염화수화물용액 침지법으로 제작한 유색 지르코니아와 전장도재의 전단결합강도)

  • Yun, Kwi-Dug;Ryu, Su-Kyoung;Vang, Mong-Sook;Yang, Hong-So;Kim, Hyun-Seung;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.151-157
    • /
    • 2010
  • Purpose: The purposes of this study was to evaluates shear bond strength between zirconia core and veneer-ceramic in order to examine the clinical practice of colored zirconia block fabricated by infiltration method into the metal chloride solution. Material and methods: CNU block and $Everest{(R)}$ ZS blank were used. VITA In-$Ceram{(R)}$2000 YZ Coloring liquid (LL1) and 3 aqueous metal chloride solutions containing chromium and molybdenum ingredients were used. 40 zirconia specimens were prepared into cuboid shape ($5{\times}5{\times}10 mm$). All specimens were divided into 5 groups by infiltrating into the coloring liquids. After that, porcelain was build up into the shape of $5{\times}5{\times}4mm^3$, followed by sintering. The maximum loading and shear bond strength was measured. Failure patterns and failure sites were examined. Results: 1. There were no statistical differences in shear bond strength between zirconia blocks (P > .05). 2. There were no statistically significant differences in shear bond strength between non-colored and colored zirconia blocks, while shear bond strength of non-colored zirconia blocks is higher than that of colored specimen (P > .05). 3. In the comparison with shear bond strength among colored zirconia blocks, there were no statistical differences according to kinds of coloring liquid (P > .05). 4. Mixed failure patterns were mainly observed in the failure between zirconia and veneering ceramic. The veneering ceramic failure of all specimens was observed in either interface of zirconia or veneering ceramic. Conclusion: Shear bond strength between colored zirconia and veneering ceramic shows lower tendency than non-colored zirconia, but there was clinically allowable value.

Mediastinal Cavernous Hemangioma Involving Whole SVC -A case report- (상대정맥 전장을 포함한 종격동 해면상 혈관종 - 1 례 보고 -)

  • Hur, Jin
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.626-629
    • /
    • 2002
  • Cavernous hemangioma in mediastinum is a rare tumor. A 13 year old girl was referred becaused of abnormal mediastinal shadow in simple chest X-ray. Chest CT scan revealed a somewhat inhomogenous cystic legion arround the whole length of SVC. Surgical excision was done through the right posterolateral thorachotomy. The pathology was confirmed as cavernous hemangioma.

Structural Design of Polyethylene Boat Hull by using Longitudinal Bending Strength Test Method (종굽힘강도시험방법을 이용한 폴리에틸렌 보트 선체의 구조 설계)

  • Cho, Seok-Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8447-8454
    • /
    • 2015
  • ISO 12215-5 standard describes allowable stress design specifications of monohull small boat with a length of hull between 2.5 m and 24 m constructed from fiber reinforced plastics, aluminium or steel alloys, glued wood or other suitable boat building material. If small boat hull is under 2.5m in overall length or nonstandard material is used as boat building material, structural reliability of small boat hull is assured by drop test specification, but not by structural design specification in accordance with ISO 12215-5. Drop test specification of boat hull can be applied to manufactured product. But it is difficult and complicated to apply drop test specification to structural design of boat hull. In this study, we present structural design method of polyethylene boat hull on the basis of longitudinal bending strength test specification.

Arthroscopic Assisted Reduction and Internal Fixation of Lateral Femoral Epiphyseal Injury in Old Adolescent Soccer Player - Report of 1 Case - (청소년기 축구선수에서 원위 대퇴외과 성장판 손상의 관절경하 정복 및 내고정 - 1례 보고-)

  • Lee, Yong-Seuk;Jung, Jae-Kyoung;Kong, Chae-Kwan;Shin, Yoon-Chang
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.66-69
    • /
    • 2007
  • Sports-related knee injuries frequently occur in adolescent period and fractures are more common than ligamentous Injuries in this age group because of physiologic characteristics. We operated an adolescent soccer player with lateral femoral epiphyseal injury using arthroscopic assisted reduction and infernal fixation. In $2^{nd}$ look arthroscopy and metal removal at postoperative 2 years, articular cartilage was healed with good congruity and lower extremity entire long film showed normal axial alignment without residual deformity.

  • PDF

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.

Evaluation of Structural Safety of Polyethylene Boats by Drop Test Method (낙하시험에 의한 폴리에틸렌 보트의 구조 안전성 평가)

  • Lee, Sung-Riong;Kang, Gyung-Ju;Cho, Seok-Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.531-542
    • /
    • 2017
  • The structural safety of small craft, such as steel ships and FRP ships, can be estimated using the measurement test of the hull plate thickness or the longitudinal bending strength test. A polyethylene boat is made using inexpensive HDPE and can be mass produced. The structural safety of a polyethylene boat cannot be guaranteed because a polyethylene boat hull is notspecified in the KR technical rules. The inspection procedure of sailing yachts and pleasure boats and drop test method of ISO standard 12215-5 propose the structural strength required for small crafts as the drop test height. Therefore, in this study, the drop test of a polyethylene boat hull was carried out based on the inspection procedure of a sailing yacht and pleasure boat and the drop test method of ISO standard 12215-5. The drop load was acquired by the drop acceleration ofa boat hull. Structural analysis and safety of a polyethylene boat were performed by the drop load and allowable stress criteria. The calculation results of the hull plate thickness by structural design specification of ISO standard 12215-5 showed that polyethylene boat hull was more than two times thicker than a steel ship hull and the boat hull determined by the inspection procedure of sailing yacht and pleasure boat and drop test method of ISO standard 12215-5 was more than 1.2 times thicker than the boat hull determined by structural design specification of ISO standard 12215-5. Therefore, inspection procedure of sailing yachts and pleasure boats and drop test method of ISO standard 12215-5 was much more conservative than the structural design specification of ISO standard 12215-5 and could be used as the structural design method of a polyethylene boat.

A Clinical Observation on Children with Corrosive Esophagitis (소아 부식성 식도염의 임상적 고찰)

  • Choi, Dong-Hyeon;Cho, Moon-Gi;Ju, Hyo-Geun;Kim, Byung-Ju;Ma, Jae-Sook
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 2000
  • Purpose: This study was undertaken to evaluate the clinical features and complication such as esophageal stricture in children with corrosive esophagitis. Methods: We retrospectively reviewed medical records of 31 children who accidentally ingested corrosive materials and visited to emergency room of Chonnam National University Hospital from Jan. 1992 to Dec. 1999. Twenty-one children were examined by upper gastrointestinal (UGI) endoscopy to evaluate location and severity of caustic injury. Results: 1) Among 31 patients, there were 20 males and 11 females and the ratio of male to female was 2:1. Average age at diagnosis was 2.3 years (12 months to 9.8 years). Twenty-seven (87.1%) patients were accidentally ingested vinegar. 2) Initial presenting symptoms were dysphagia (54.8%), vomiting (48.3%), chemical burn on lips and skin (45.2%), excessive salivation (45.2%), coughing and respiratory grunting (32.3%) and aspiration pneumonia (9.8%). 3) UGI endoscopic examination showed caustic injury in 17 children: grade I in 8, grade II in 7 and grade III in 2. The region of caustic injury was proximal esophagus in 5, distal esophagus in 3, entire esophagus in 9 and stomach in 6. 4) Corrosive esophageal strictures developed in 6 children (19.4%) and gastric outlet stricture in 1 (3.2%). All of them showed grade II or III caustic injury on endoscopic examination. Conclusion: The development of esophageal stricture was related to the severity of the caustic injury. Early UGI endoscopic examination in caustic ingestion seems to be useful for prediction of development of caustic stricture.

  • PDF

Effect of Application of ZirLiner® and Blasting Treatments on Shear Bond Strength of Zirconia-Veneered Porcelain Interface (지르코니아-전장도재 계면의 전단결합강도에 대한 ZirLiner® 적용과 분사처리의 영향에 관한 연구)

  • Shin, Young-Ho;Lee, Yu-Na;Lee, Hae-Hyoung;Dong, Jin-Keun;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.113-127
    • /
    • 2008
  • The purpose of this study was to evaluate effect of application of $ZirLiner^{(R)}$ and blasting treatments on shear bond strength of zirconia-veneered porcelain interface. 60 uncolored zirconia plates and 30 colored zirconia plates were fabricated and divided into nine groups of 10 according to blasting treatment such as as-ground, glass blasting and alumina blasting and zirliner application. Veneering porcelains were built up over the center of the treated zirconia ceramic surface using jig and fired according to the manufacturers' instructions. Each specimen was completely embedded in acrylic resin. The specimens were placed in a mounting jig and subjected to shear force by a universal testing machine. Load was applied at a crosshead speed of 0.5㎜/min until failure. Average shear strengths were analyzed with two-way analysis of variance and one-way analysis of variance and the Duncan's post-hoc test. The fracture surfaces of the failed specimens were examined by SEM. The obtained results were as follows: 1. Depending on surface treatment by blasting, the degree of roughness is revealed in the order of Glass-blasted, As-ground, and Alumnia-blasted. The roughness average of uncolored and colored zirconia ceramic were not significantly different from blasting treatments. 2. In uncolored zirconia ceramic, the shear bond strength were not significantly different from blasting treatments. However, the shear bond strength were significantly different from Zirliner application. 3. Used ZirLiner, mean shear bond strength of colored zirconia was lower than uncolored zirconia. Especially, mean shear bond strength of colored zirconia was quite low with alumina-blasting treatment. 4. SEM analysis showed that veneered porcelain failed in zirconia ceramic interface and there was no cohesive failure.

Effect of Mercuric Chloride on the Contents of Mineral Nutrients in the Liver and Kidney of Rats (흰쥐의 간장(肝臟) 및 신장(腎臟) 무기질(無機質)에 미치는 수은(水銀)의 영향(影響))

  • Cho, Soo-Yeul;Park, Sun-Woo;Lee, Sang-Il
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.13 no.1
    • /
    • pp.22-26
    • /
    • 1984
  • The effect of changes in body weight, some blood components and some inorganic ions in liver and kidney, were studied on male rats receiving ad libitum on 5, 40, and 200 ppm of mercuric chloride solution during so days. The results obtained were summarized as follows ; 1. The total body weights were decreased in proportion to increment of mercury concentration. The internal organs weights i. e. , liver, kidney, spleen, and heart, were generally increased. Especially, the weight increment of kidney was the highest by intaking of mercuric chloride solution. 2. There were no significant changes in hematocrit values, activities of GOT and GPT in blood of rats receiving mercuric chloride. On the other hand, the plasma levels of cholesterol were significantly increased. The receiving of 200 ppm mercuric chloride solution to rats was resulted in the remarkable reduction of total protein levels and A/G ratio in plasma. 3. The markable rise occured in the accumulation of Hg, in both liver and kidney in proportion to supplying in rats while there was a tendency decreasing of Cu, Zn contents in liver, whereas there was a tendency increasing of Cu, Zn in kidney of rats.

  • PDF