• Title/Summary/Keyword: 전위성

Search Result 1,252, Processing Time 0.024 seconds

Posterior Cruciate Ligament and Posterolateral Structure Reconstruction using Bilateral Hamstring Tendons (양측 슬괵건을 이용한 후방 십자 인대 및 후외측 지대 재건술)

  • In, Yong;Kim, Seok-Jung;Lee, Gyu-Yeong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.167-173
    • /
    • 2005
  • Purpose: The purpose of this study is to evaluate the clinical results of posterior cruciate ligament (PCL) and posterolateral structure (PLS) reconstruction using bilateral hamstring tendon autografts. Materials and Methods: From October 2002 to March 2004, ten patients were received PCL and PLS reconstruction simultaneously using bilateral hamstring autografts. PCL was reconstructed using ipsilateral hamstring tendon and fixed with cross pins and Intrafix (Mitek, Norwood, MA). PLS was reconstructed using contralateral hamstring tendon. The mean follow up was 17 months. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee (IKDC) evaluation form and posterior stress radiographs. External rotation of tibia was evaluated at $30^{\circ}\;and\;90^{\circ}$ knee flexion using Noyes and Barber-Westin's classification. Contralateral harvest site morbity was evaluated using IKDC evaluation form and flexion power of the knee. Results: Mean posterior displacement of tibia using stress radiographs was improved from 13.3 mm to 3.7 mm. In tibial external rotation evaluation, 7 patients were functional, 2 patients were partially functional and one failure. The average Lysholm knee score improved from 54 preoperatively to 86 postoperatively. At the final IKDC evaluation, 8 patients were graded as nearly normal, 2 were graded as abnormal. In contralateral harvest site morbidity evaluation, 2 patients complained of numbness around the wound but negligible. Conclusion: PCL and PLS reconstruction using bilateral hamstring autografts was considered as a good treatment method with minimal contralateral harvest site morbidity.

  • PDF

Comparison of Characteristics on Electrolyzed Water Manufactured by Various Electrolytic Factors (전해인자에 따른 전기분해수의 특성 비교)

  • Kim, Myung-Ho;Jeong, Jin-Woong;Cho, Young-Je
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.416-422
    • /
    • 2004
  • Efficacy of surface sterilization and physicochemical properties of electrolyzed water manufactured depending on electrolyte, materials, and type of electrolytic diaphragm used were investigated. Physical properties of electrolyzed water manufactured from diaphragm system showed the highest effectiveness under at distance between diaphragms of 1.0 mm and 20% NaCl supplying rate of 6 mL/min. ORP, HClO (should defined) content, and pH at above conditions were 1,170 mV, 100 ppm, and 2.5, respectively. Two-stage electrolyzed system was more effective than one-stage one. Electrolyzed water manufactured from non-diaphragm system at 4 mL/min supplying rate of 20% NaCl was similar to the most effective diaphragm system, whereas ORP, HClO content, and pH were 800 mV, 200 ppm, and 9, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORPs of 750 and 1,150 mV in non-diaphragm and diaphragm systems, respectively, and at HClO content of 100 ppm. Physicochemical properties of electrolyzed water manufactured from electrolytic diaphragm of $IrO_{2}$ and Pt+Ir were more effective than that of Pt. ORP and HClO contents of electrolyzed water manufactured from various electrolytes were high in order of NaCl>KCl>$CaCl_{2}$, whereas no differences were observed among electrolytes in sterilization efficacy. Twelve kinds of microorganisms tested (initial total count, $10^{5}-10^{6}CFU/mL$) were sterilized within 1-2 min by electrolyzed water.

The Study on Properties and Application of Enhanced Dynamic Wedge Factor (향상된 동적쐐기인자(Enhanced Dynamic Wedge Factor)의 특성 및 적용에 관한 고찰)

  • Kim, Dae-Sup;Ban, Tae-Joon;Yeom, Mi-Suk;Yoo, Soon-Mi;Lee, Woo-Seok;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • Purpose: We try to calculate EDW-factor easily with the formula applies essential data of EDW-factor and evaluate the validity through a measurement. Materials and Methods: We used the given value of GSTT (Golden Segmented Treatment Table) for the calculation of the EDW-factor. As to the experimental device, 0.6 cc farmer-type ion-chamber, an electrometer and water- phantom were used. A measurement was made at the maximum dose depth of the photon beam energy 6 MV and 15 MV under the condition that SSD (Source to Surface Distance) was 100 cm. The angle of the EDW (Enhanced Dynamic Wedge) which we use in an experiment was 60 degree, 30 degree, 20 degree in the Y1-OUT direction. We used Eclipse planning system (Varian, USA) as RTP system and the EDW-factor was calculated about all fields and EDW direction. In order to show the EDW-factor feature, a measurement was made at the selected field that verify the influence of the dependability about X, Y jaw and off-axis field. Results: When we change the Y1 field, it influence on the EDW-Factor and measured value. But the error between measured values and calculated values was less than 1%. The experimental result indicated the tendency that the error of the result of calculation and measured value becomes smaller as the EDW angle become smaller whether the calculation point (measurement point) and iso-center are same or not. The influence of the field size and energy did not show up. We simulated with the same condition using the RTP system. And we found that it makes no difference between the MU which is calculated manually by applying the EDW-Factor obtained from the commercial program and the value which is calculated by using RTP system. Conclusion: We excluded fitting value from well-known EDW-Factor formula and calculated EDW-factor with the formula applies essential data of EDW-factor only. As a result, there are no significant difference between the measured value and calculated value and it showed errors less than 1%. Also, we implemented the commercial program to calculate EDW-Factor conveniently without measure a factor on each field.

  • PDF

The Short Term Clinical Follow-up Study for Hemiarthroplasty in Proximal Humeral Fracture (상완골 근위부 분쇄 골절에서의 상완골 두 치환술의 단기 추시 결과)

  • Sung, Chang-Meen;Cho, Se-Hyun;Jung, Soon-Taek;Hwang, Sun-Chul;Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.92-98
    • /
    • 2007
  • Introduction: The treatment of proximal humeral fracture is traditionally determined by Neer's classification system. The severely displaced three-part or four-part fracture is an indication for primary hemiarthroplasty. The current authors report the clinical results of 10 patients who received hemiarthroplasty for proximal comminuted fractures. The minimum follow-up period was 12 months. Materials and Methods: The current authors studied 10 patients who, between July 1999 and March 2005, each received hemiarthroplasty for a proximal humeral fracture of one shoulder. According to Neer's classification system, 5 of the patients had three-part fractures, and 5 of the patients had 4-part fractures. The mean interval between trauma and hemiarthroplasty was 6.1 days. The mean age of the 6 female and 4 male patients was 67.4 years(range: 56 to 76). Shoulder function was evaluated using the Constant score, the Simple Shoulder Test, and the modified UCLA score. Results: The mean Constant score was 51.4(range: 34 to 60). The mean modified SST score was 7.8 out of 12 tasks. Excluding the one patient who had also sustained an axillary artery rupture and a brachial plexus injury after the initial trauma, the mean Constant score for the remaining 9 patients was 53.5(range: 44 to 60), and the mean SST score was 7.2 tasks. The modified UCLA score averages for pain, function, and active forward flexion and strength were, respectively, 8.2($6{\sim}10$), 6.6($2{\sim}8$), and 6.9($4{\sim}8$). The total UCLA score was an average of 21.7($12{\sim}26$). Patients' the modified UCLA ratings were as follows: Excellent: 3, Good: 6, and Poor: 1. The patient with the poor outcome was the one who had also sustained the neurovascular injury. Patient's subjective satisfaction rating were as follows: Excellent: 2, Good: 7, and Poor: 1. Conclusion: Based on short term follow-up results, this study indicates that hemiarthroplasty is the treatment of choice for proximal humeral fractures on which it would be difficult to perform open reduction and internal fixation. Hemiarthroplasty is a useful treatment modality to prevent shoulder stiffness and to allow daily living tasks in elderly patients. However, restoration of muscle power and range of joint motion were not recovered satisfactorily.

Analysis of Bacterials Community Structure in Leadchate-Contaminated Groundwater using Denaturing Gradient Gel Electrophoresis (Denaturing Gradient Gel Electrophoresis를 이용한 매립지 침출수로 오염된 지하수의 세균 군집 분석)

  • Kim Jai-Soo;Kim Ji-Young;Koo So-Yeon;Ko Kyung-Seok;Lee Sang-Don;Cho Kyung-Suk;Koh Dong-Chan
    • Microbiology and Biotechnology Letters
    • /
    • v.34 no.2
    • /
    • pp.166-173
    • /
    • 2006
  • This research has been performed to clarify the relationship between hydrogeochemistry and bacterial community structure in groundwater contaminated with landfill leachate. We collected and analyzed samples from 5 sites such as leachate (KSG1-12), treated leachate (KSG1-16), two contaminated groundwaters (KSG1-07 and KSG1-08) and non-contaminated groundwater (KSG1-13). pH was 8.83, 8.04, 6.87, 6.87 and 6.53 in order; redox potential (Eh) 108, 202, 47, 200 and 154 mV; electric conductivity (EC) 3710, 894, 1223, 559 and 169.9 $\mu$S/cm; suspended solids (SS) 86.45, 13.74, 4.18, 0.24 and 11.91 mg/L. In KSG01-12, the ion concentrations were higher especially in $Cl^-$ and $HCO_3^-$ than other sites. The concentrations of Fe, Mn and $SO_4^{2-}$ were higher In KSG1-07 than in KSG1-08, and vise versa in $NO_3^{2-}$. In the comparison of DGGE fingerprint patterns, the similarity was highest between KSG1-13 and KSG1-16 (57.2%), probably due to common properties like low or none contaminant concentrations. Otherwise KSG1-08 showed lowest similarities with KSG1-13 (25.8%) and KSG1-12 (27.6%), maybe because of the degree of contamination. The most dominant bacterial species in each site were involved in $\alpha$-Proteobacteria (55.6%) in KSG1-12, $\gamma$-Proteobacteria (50.0%) in KSG1-16, $\beta$-Proteobacteria (66.7%) in KSG1-07, $\gamma$-Proteobacteria (54.5%) in KSG1-08 and $\beta$-Proteobacteria (36.4%) in KSG1-13. These results indicate that the microbial community structure might be changed according to the flow of leachate in grounderwater, implying changes in concentrations of pollutants, available electron accepters and/or other environmental conditions.

Apoptotic Effect of Co-Treatment with Valproic Acid and HS-1200 on Human Osteosarcoma Cells (Valproic acid와 HS-1200의 병용처리가 사람골육종세포에 미치는 세포자멸사 효과에 대한 연구)

  • Kim, Duck-Han;Lee, Kee-Hyun;Kim, In-Ryoung;Kwak, Hyun-Ho;Park, Bong-Soo;Jeong, Sung-Hee;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.3
    • /
    • pp.165-175
    • /
    • 2010
  • Valproic acid (VPA) is a well-known anticonvulsive agent and has been used in the treatment of epilepsy for almost 30 years. VPA emerged in 1997 as an antineoplastic agent as well, when findings indicated the substance inhibited proliferation and induced differentiation of primitive neuroectocdermal tumor cells in vivo (Cinatl et al., 1997). Antitmor activity of VPA is associated with its targeting histone deacetylases. Bile acids and their synthetic derivatives induced apoptosis in various kinds of cancer cells and anticancer effects. It has been reported that the synthetic chenodeoxycholic acid (CDCA) derivatives showed apoptosis-inducing activity on various cancer cells in vitro. This study was undertaken to investigate the synergistic apoptotic effect of co-treatment with the histone deacetylases inhibitor, VPA and a CDCA derivative, HS-1200 on human osteosarcoma (HOS) cells. Cell viability was evaluated by trypan-blue exclusion. Induction and augmentation of apoptosis were confirmed by Hoechst staining, flow cytometry (DNA hypoploidy and MMP change), Westen blot analysis and immunofluorescent staining. In this study, HOS cells co-treated with VPA and HS-1200 showed several lines of apoptotic manifestation such as nuclear condensations, the reduction of MMP, the decrease of DNA content, the release of cytochrome c into cytosol, the translocation of AIF onto nuclei, and activation of caspase-7, caspase-3 and PARP whereas each single treated HOS cells did not. Although the single treatment of 1 mM VPA or $25\;{\mu}M$ HS-1200 for 48 h did not induce apoptosis, the co-treatment of them induced prominently apoptosis. Therefore our data provide the possibility that combination therapy of VPA and HS-1200 could be considered as a novel therapeutic strategy for human osteosarcoma.

Anterior Cruciate Ligament Reconstruction: Comparison of Bone-Patellar tendon-Bone Grafts with Hamstring Tendon Grafts (자가 슬개건과 자가 슬괵건을 이용한 전방십자인대 재건술의 비교)

  • Choi, Sung-Wook;Oh, In-Suk;Kim, Ryuh-Sup;Kim, Myung-Ku;Bae, Joo-Han;Park, Hae-Bong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • Purpose: The purpose of this study is to compare the results of the arthroscopic reconstruction of ACL using autologous hamstring tendon and autologous bone-patellar tendon-bone. Materials and Methods: From January, 2000 to December, 2004, 120 patients underwent arthroscopic ACL reconstruction using autologous hamstring tendon(60 cases) and autologous bone-patellar tendon-bone(BPTB)(60 cases). The mean followed up period of hamstring tendon group was 42 months(range $24{\sim}69$ months) and patellar tendon group was 52 months(range $24{\sim}84$ months). At the time of the final follow up, sixty patients in each group were evaluated the results of physical examination, activity level, patients' satisfaction, functional status, and objective anteriror stability using KT-2000 arthrometer. Results: At the time of the final follow up we compared the two groups who had ACL reconstruction using either autologous hamstring tendon or BPTB, and the final results of the Lachman test showed negative, or mildly positive in 85%(51 cases) of the hamstring tendon group and 90%(54 cases) of the BPTB group. Pivot shift test indicated positive in both groups, 8%(5 cases) and 5%(3 cases) respectively and showed no statistically significant difference. The evaluation of the anterior laxity using the KT-2000 arthrometer revealed no significant difference in the hamstring and BPTB groups: differences less than 3 mm compared to the healthy side were 85%(51 cases) and 90%(54 cases)(p>0.05). The Lysholm score improved from a preoperative score of 51 to a postoperative score of 79.1 in the hamstring groups and from 52 to 82.2 in the BPTB groups. According to the IKDC rating system, 87%(52 cases) were normal or near normal in the hamstring group. In the BPTB group, 83%(50 cases) were normal or near normal. The Tegner score for the hamstring groups was 4.8 preoperatively and 7.1 at the final follow up, and the Tegner score for the BPTB groups was 4.5 preoperatively and 7.3 after the last follow-up. The anterior knee pain was found in 7%(4 cases) in the hamstring tendon group and 10%(6 cases) in the patellar tendon group. Conclusion: Arthroscopic ACL reconstruction using both the autologous hamstring tendon and the patellar tendon during their mid term follow up period demonstrated excellent results. However, the final results during their last follow up showed no statistically significant difference between the two groups.

  • PDF

The characteristic of InGaN/GaN MQW LED by different diameter in selective area growth method (선택성장영역 크기에 따른 InGaN/GaN 다중양자우물 청색 MOCVD-발광다이오드 소자의 특성)

  • Bae, Seon-Min;Jeon, Hun-Soo;Lee, Gang-Seok;Jung, Se-Gyo;Yoon, Wi-Il;Kim, Kyoung-Hwa;Yang, Min;Yi, Sam-Nyung;Ahn, Hyung-Soo;Kim, Suck-Whan;Yu, Young-Moon;Ha, Hong-Ju
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.1
    • /
    • pp.5-10
    • /
    • 2012
  • In general, the fabrications of the LEDs with mesa structure are performed grown by MOCVD method. In order to etch and separate each chips, the LEDs are passed the RIE and scribing processes. The RIE process using plasma dry etching occur some problems such as defects, dislocations and the formation of dangling bond in surface result in decline of device characteristic. The SAG method has attracted considerable interest for the growth of high quality GaN epi layer on the sapphire substrate. In this paper, the SAG method was introduced for simplification and fabrication of the high quality epi layer. And we report that the size of selective area do not affect the characteristics of original LED. The diameter of SAG circle patterns were choose as 2500, 1000, 350, and 200 ${\mu}m$. The SAG-LEDs were measured to obtain the device characteristics using by SEM, EL and I-V. The main emission peaks of 2500, 1000, 350, and 200 ${\mu}m$ were 485, 480, 450, and 445 nm respectively. The chips of 350, 200 ${\mu}m$ diameter were observed non-uniform surface and resistance was higher than original LED, however, the chips of 2500, 1000 ${\mu}m$ diameter had uniform surface and current-voltage characteristics were better than small sizes. Therefore, we suggest that the suitable diameter which do not affect the characteristic of original LED is more than 1000 ${\mu}m$.

Apoptotic Effect of co-treatment with HS-1200 and Cisplatin on SCC25 Human Tongue Squamous Cell Carcinoma Cell Line (HS-1200과 cisplatin의 병용처리가 사람구강암세포에 미치는 세포자멸사 효과에 대한 연구)

  • Kim, Duk-Han;Kim, In-Ryoung;Park, Bong-Soo;Ahn, Yong-Woo;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.3
    • /
    • pp.221-233
    • /
    • 2013
  • Bile acids are polar derivatives of cholesterol essential for the absorption of dietary lipids and regulate the transcription of genes that control cholesterol homeostasis. Recently it have been identified the synthetic chenodeoxycholic acid (CDCA) derivatives HS-1200 and cisplatin showed apoptisis-inducing activity on various cancer cells in vivo and in vitro. This study was undertaken to investigate the synergistic apoptotic effect of co-treatment with HS-1200 and cisplatin on human tongue squamous cell carcinoma cells (SCC25 cells). To investigate whether the co-treatment with HS-1200 and cisplatin compared to each single treatment efficiently reduces the viability of SCC25 cells, MTT assay was conducted. The induction and augmentation of apoptosis were confirmed by DNA electrophoresis, Hoechst staining and an analysis DNA hypoploidy. Westen blot analysis and immunofluorescent staining were also performed to evaluate the expression levels and the translocation of apoptosis-related proteins following this co-treatment. Furthermore, proteasome activity and mitochondrial membrane potential (MMP) change were also assayed. In this study, co-treatment with HS-1200 and cisplatin on SCC25 cells showed several lines of apoptotic manifestation such as nuclear condensations, DNA fragmentation, reduction of MMP and proteasome activity, the increase of Bax and the decrease of Bcl-2, decrease of DNA content, the release of cytochrome c into cytosol, translocation of AIF and DFF40 (CAD) onto nuclei, and activation of caspase-9, caspase-7, caspase-3, PARP and DFF45 (ICAD) whereas each single treated SCC25 cells did not show these patterns. Although the single treatment of $25{\mu}M$ HS-1200 and $4{\mu}g/ml$ cisplatin for 24 h did not induce apoptosis, the co-treatment of these reagents prominently induced apoptosis. Therefore our data provide the possibility that the combination therapy with HS-1200 and cisplatin could be considered as a novel therapeutic strategy for human squamous cell carcinoma.

The changes of electrocardiography and signal-averaged electrocardiography after surgical repair of Tetralogy of Fallot (활로씨 4징의 교정 수술 후 심전도와 신호 평준화 심전도의 변화)

  • Seo, Hye-Eun;Lim, Hae-Ri;Kim, Yeo-Hyang;Hyun, Myung-Chul;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.462-468
    • /
    • 2007
  • Purpose : The purpose of this study was to analyze the changes of the late potential of Signal- averaged electrocardiography (SAECG) and Electrocardiography (ECG) parameters during follow up of those who had taken surgical repair of Tetralogy of Fallot (TOF). Methods : Nine patients who had taken surgical repair of TOF since 1985 checked SAECG and standard 12 leads ECG twice in 1999 and 2005 in Kyungpook national university hospital. We evaluated changes of QRS duration, QT interval and JT interval, QRS dispersion, QT dispersion and JT dispersion of standard 12 leads ECG and Filtered QRS (f-QRS), High frequency low amplitude potential (HFLA), Root mean square in terminal 40 ms (RMS) and Mean voltage in terminal 40 ms (MV) of SAECG between in 1999 and 2005. Results : There were significant decrease of JT dispersion ($101.11{\pm}50.11$ vs $71.11{\pm}22.61ms$, P< 0.05) and significant increase of HFLA ($24.67{\pm}13.19$ vs $32.89{\pm}14.21ms$, P<0.05). But there were no significant changes in other parameters. Conclusion : In repaired TOF patients, we evaluated ECG and SAECG to detect possible late complications such as tricuspid regurgitation, right ventricular enlargement, ventricualar arrythmia and sudden death. And there were significant changes of ECG and SAECG in some parameters (JT dispersion, HFLA). But to see the relationships between the changes of these parameters and the long term prognosis, we need to check more patients and longer follow-up.