• Title/Summary/Keyword: 전압 발생기

Search Result 1,068, Processing Time 0.035 seconds

Effects of Grid Characteristics on High Speed Circuit Breaker for Railway Vehicle (철도 차량용 직류 고속도 차단기의 그리드 특성 해석)

  • Park, Ji-Won;Jung, Jooyoung;Choi, Jinnil
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.2
    • /
    • pp.117-123
    • /
    • 2016
  • High speed circuit breakers(HSCB) interrupt the generated arc within the arc chute to turn off the electricity flowing through the main circuit to prevent ground faults. In order to explore the arc generated from the contactor operation, arc definition, establishment of arc interruption method, and analysis of magnetic driving force are required. In this paper, arc interruption capability has been estimated by exploring the difference in magnetic flux density of Lorenz forces using finite element analysis. In addition, since the number of grids and changes in the grid shape within the arc chute influence the formation of the inner magnetic field, its effects have been explored to enhance arc interruption capability. Assessment of interruption capability and analysis of grid shape, with rated operating current, are reported.

양산에 적합한 구조의 X-ray 검출기 공정에 대한 연구

  • Gwon, Jun-Hwan;O, Gyeong-Min;Song, Yong-Geun;Kim, Ji-Na;No, Seong-Jin;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.265-266
    • /
    • 2012
  • 의료용 X-ray의 발전에 따라, 영상의 Digital화가 필요하게 되었다. Digital 영상 구현을 위해 다양한 형태의 영상 검출기가 개발되었다. 진단 영상의 조건으로는 구현 시간이 빠르고 해상도가 높아야 한다. 조건에 부합하는 Flat panel 형태의 직접방식과 간접방식 검출기의 개발이 주로 이루어졌으며, X-ray 검출 효율이 높고 공간 분해능이 높은 직접 방식의 검출기에 대한 연구가 활발히 진행되고 있다. 기존 직접방식의 X-ray 검출물질로는 A-Se이 이용되었다. 하지만 A-Se의 경우 낮은 원자번호로 인해 X-ray에 대한효율이 낮으며, 제조 공정과 수율의 문제로 인해 대체 물질의 개발과 공정의 개선이 필요하다. 선행 연구를 통해 X-ray 검출물질의 전기적 특성을 파악을 통해 대체 물질로서 가능성을 알아보았다. 본 연구에서는 기존에 제작된 X-ray 검출물질의 상부전극 증착 물질과 증착법 선정에 대한 연구이다. 선행 연구를 통해 선정된 X-ray 검출물질은 HgI2이다. 상, 하부 전극 선택에 있어 HgI2의 일함수 값(4.15eV)을 고려하여 그와 비슷한 일함수 값을 가진 물질로 전기적 장벽을 제거하여야 한다. 따라서, ITO (일함수 4.45eV)와 Au (일함수 5.1eV)을 선택하였다. ITO의 증착으로 이용된 방법으로는 on-axis 형태의 magnetron plasma sputtering을 이용하였으며, Au의 증착으로 이용된 방법은 Thermal evaporation deposition을 이용하였다. plasma sputtering에 이용된 타겟은 In2O3;SnO2 (조성비:90:10wt%)를 사용하였으며, Chamber의 크기는 넓이 456 ${\phi}cm^2$ 높이 25 cm이며, 로 target과 기판과의 거리는 15cm이다. plasma발생에 필요한 가스로는 Ar과 O2를 이용하였다. 고 진공 환경 조성에 이용된 장비로는 Rotary pump와 Turbo molecular pump이다. plasma 발생 전 진공도는 $3.2{\times}10^{-5}$ Torr, 발생 후 진공도는 $5.1{\times}10^{-5}$ Torr이다. plasma 환경이 조성된 후 증착 시간은 1분 30초이다. Au는 순도 99.999%를 이용하였으며, 이용된 금은 1회 증착에 0.3 g을 이용하였다. Chamber의 넓이 1,444 ${\phi}cm^2$이며, 높이 40 cm, boat와 기판과의 거리는 25 cm이다. 고 진공 환경 조성에 이용된 장비로는 Rotary pump와 diffusion pump를 이용하였다. Au의 승화 전 진공도는 $2.4{\times}10^{-5}$ Torr 증착 시 진공도는 $4.2{\times}10^{-5}$ Torr이며, Boat에 가해준 전압, 전류는 0.97 V, 47 A이며, 증착 시간은 1분 30초이다. 광도전체 층에 각각 증착된 전극의 저항을 통해 증착상태를 판단하였다. DMM (Digital Multimeter)로 1 cm 간격으로 측정된 표면의 저항은 ITO 약 $8{\Omega}$, Au 약 $3{\Omega}$으로 전극으로서 이용이 가능한 상태이다. Au와 ITO가 증착된 HgI2 시편의 전기적 특성은 기존에 이용된 X-ray 변환물질의 성능보다 우수하였다. 하지만 Au와 ITO가 각각 증착된 시편의 전기적 특성은 큰 차이를 보이지 않았다. ITO의 경우 진공 상태에서 이용되는 Gas가 이용되며, Plasma 환경 조성 유지가 어려운 점이 있다. Au전극은 증착 환경 조성이 쉽지만, 전극 물질 이용효율이 떨어지는 단점이 있다. 본 연구를 통해 X-ray 변환물질인 HgI2의 전극물질로 Au와 ITO의 이용가능성을 알아보았다. 두 전극으로 제작된 검출기의 성능은 큰 차이 없이 우수하였고, 전기적 장벽 상태가 낮아 높은 검출 효율을 보였다. 상대적으로 Au 전극의 공정이 간단하고 수율이 높다. 하지만 Au Source의 이용 효율이 떨어지는 단점이 있다. 본 연구의 결과를 통해 공정상의 유리함과 Source의 이용효율을 고려한 분석에 대한 연구가 필요할 것으로 사료된다.

  • PDF

Wirelessly Driven Cellulose Electro-Active Paper Actuator: Application Research (원격구동 셀룰로오스 종이 작동기의 응용연구)

  • Kim, Jae-Hwan;Yang, Sang-Yeol;Jang, Sang-Dong;Ko, Hyun-U;Mun, Sung-Cheol;Kim, Dong-Gu;Kang, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.539-543
    • /
    • 2012
  • Cellulose Electro-Active Paper (EAPap) is attractive as a biomimetic actuator because of its merits: it is lightweight, operates in dry conditions, has a large displacement output, has a low actuation voltage, and has low power consumption. Cellulose is regenerated so as to align its microfibrils, which results in a piezoelectric paper. When chemically bonded and mixed with carbon nanotubes, titanium oxide, zinc oxide, tin oxides, the cellulose EAPap can be used as a hybrid nanocomposite that has versatile properties and that can meet the requirements of many application devices. This paper presents trends in recent research on the cellulose EAPap, mainly on material preparation and its use in devices, including biosensors, chemical sensors, flexible transistors, and actuators. This paper also explains wirelessly driving technology for the cellulose EAPap, which is attractive for use in biomimetic robotics and micro-aerial vehicles.

Study of Optimum Operating Conditions of Thermal Acoustic Generator (열음향파 발생장치의 최적 작동 조건에 대한 실험적 연구)

  • Shin, Sang Woong;Oh, Seung Jin;Lee, Yoon Joon;Kim, Nam Jin;Chun, Wongee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.131-137
    • /
    • 2013
  • This study deals with the effects of major geometric parameters on the sound wave output of a thermal acoustic system. The output power of the acoustic wave was dependent on the stack position, stack length, resonator tube length, and input power. In experiments, the maximum SPL was generated when the stack was placed between one-fourth to half, resonator and stack length were longer, and input power was increased. The frequency was recorded to be 437 and 885 Hz when the resonator tube length was 200 and 100 mm, respectively. Therefore, when the resonator tube length was shorter, a higher frequency was recorded.

Development of a Low frequency Operating Electronic Ballast for Fish Attracting Lamps (저주파 구동형 집어등용 전자식 안정기 개발)

  • Kil Gyung-suk;Kim Il-kwon;Song Jae-yong;Han Ju-seop;Shin Gwang-chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.1052-1058
    • /
    • 2005
  • This paper dealt with the design and fabrication of a low frequency electronic ballast for ruh attracting lamps. The proposed electronic ballast was composed of a full-wave rectifier, a step don converter operated as a constant power controled current source, an inverter operated by 130 Hz square wave, and an ignition circuit. An acoustic resonance phenomenon of discharge lamps could be eliminated by application of 130 Hz square wave. Also, a circuit of high voltage pulse generation for lamp ignition was added to the ballast. From the experimental results, voltage and current of the lamp operated by the electronic ballast were estimated 132.5 V and 7.6 A, respectively. and the power consumption was about 1,000 W. The weight of the ballast, which is one of important advantages, was reduced to one-fifth of conventional magnetic ballasts.

Design of a CMOS Single Bit 3rd Order Delta-Sigma Modulator with Switched Operational Amplifier (스위치드 연산증폭기를 이용한 CMOS 단일비트 3차 델타시그마 변조기 설계)

  • Lee, Han-Ul;Dai, Shi;Yoo, Tai-Kyung;Lee, Keon;Yoon, Kwang-Sub;Lee, Sang-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8A
    • /
    • pp.712-719
    • /
    • 2012
  • This paper presents Single-bit Third order Delta-Sigma Modulator, which can be applied to the Low speed High resolution ADC in Audio signal Process System. Whereas the Operational Amplifier in modulator consumed static power dissipation in operating, this modulator used Switching on/off techniques, which makes the Power dissipation of the modulator reduced. Also proposed modulator minimizes frequency characteristic variation by optimizing switch position. And this modulator chooses Single-bit type to guarantee stability. The designed ADC went through 0.35um CMOS n-well 1-poly 4-metal process to be a final product, and the final product has shown 17.1mW of power dissipation with 3.3V of Supply Voltage, 6.4MHz of conversion rate. And 84.3dB SNDR and 13.5bit ENOB with 20KHz of input frequency.

Development of a High-Performance Bipolar EEG Amplifier for CSA System (CSA 시스템을 위한 양극 뇌파증폭기의 개발)

  • 유선국;김창현;김선호;김동준
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • When we want to observe and record a patient's EEG in an operating room, the operation of electrosurgical unit(ESU) causes undesirable artifacts with high frequency and high voltage. These artifacts make the amplifiers of the conventional EEG system saturated and prevent the system from measuring the EEG signal. This paper describes a high-performance bipolar EEG amplifier for a CSA (compressed spectral array ) system with reduced ESU artifacts. The designed EEG amplifier uses a balanced filter to reduce the ESU artifacts, and isolates the power supply and the signal source of the preamplifier from the ground to cut off the current from the ESU to the amplifier ground. To cancel the common mode noise in high frequency, a high CMRR(common mode rejection ratio) diffferential amplifier is used. Since the developed bipolar EEG amplifier shows high gain, low noise, high CMRR, high input impedance, and low thermal drift, it is possible to observe and record more clean EEG signals in spite of ESU operation. Therefore the amplifier may be applicable to a high-fidelity CSA system.

  • PDF

A Study on Wireless Broadband Internet RF Down Converter Design and Production (휴대무선인터넷 RF 하향 변환기 설계 및 제작에 관한 연구)

  • Lee, Chang-Hee;Won, Young-Jin;Lee, Jong-Yong;Lee, Sang-Hun;Lee, Won-Seok;Ra, Keuk-Hwan
    • 전자공학회논문지 IE
    • /
    • v.45 no.1
    • /
    • pp.31-37
    • /
    • 2008
  • A Wibro RF down converter of 2.3GHz band is designed and implemented in this paper. The problems that can occur in the receiver LNA(Low Noise Amplifier) to minimize additional purposes. In addition, 2.3GHz band from the 75 MHz downward to minimize the losses in the process, transform and improve efficiency, and achieve stable characteristics can be used to make high frequency characteristics of the device. Wibro repeater uses a TDMA(Time Division Multiplexing Access) method is needed because the RF switch. Production criterion specification, the input voltage from +8 V 1.2A of current consumption, 60dB gain and the noise figure of less than 2.5dB, VSWR(Voltage Standing Wave Ratio) less than 1.5, more than IMD(Inter Modulation Distortion) 60dB satisfied. Environmental conditions ($-20^{\circ}C$ to $70^{\circ}C$) to pass the test of reliability in a long time, that seemed crafted Wibro down converter be applied to the Wibro repeater.

A Simulator for Performance Evaluation of Historical Data Compression Algorithm (이력 데이터 압축 알고리즘의 성능평가를 위한 시뮬레이터)

  • Yoo, Min-Hyung;Kim, Ho-Young;Han, Sang-Hyuck;Kim, Young-Kuk
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06a
    • /
    • pp.182-184
    • /
    • 2012
  • 산업분야에서 이용되는 이력 데이터는 압력, 부피, 온도, 볼트, 전류, 전압 등 각종 제어기나 센서에서 발생하는 입력 정보를 일정 시간 간격으로 수집되는 데이터로, 데이터의 값이 일정하거나 값의 폭이 좁고, 많게는 수만 개의 포인트가 실시간으로 수집, 저장되어지는 대용량의 데이터라는 특징이 있다. 이러한 특성을 지닌 이력 데이터는 이력의 모든 데이터를 저장하지 않고, 전체를 대표하는 데이터의 일부만을 저장함으로써 이력 데이터의 효율적인 관리와 공간효율을 극대화시킬 수 있다. 이러한 이력 데이터를 효과적으로 관리하고, 보관하기 위해 이력 데이터 압축 알고리즘에 대한 개발과 연구가 진행 중이다. 그러나 이미 알려져 있는 이력 데이터 압축 알고리즘과 개발하고 있는 알고리즘의 성능에 대한 평가를 할 수 있는 시뮬레이터는 개인이나 소규모 집단만을 위해 만들어지거나, 공개되지 않고 있어 사용하기에 제한적이다. 이에 이력 데이터 압축 성능평가를 위한 시뮬레이터인 HDCS(Historical Data Compression Simulator)를 설계하고 구현하고자 한다.

Arc Ion Plating Deposition System의 Bias 종류에 따른 TiN 박막의 특성평가

  • Kim, Wang-Ryeol;Park, Min-Seok;Kim, Dae-Yeong;Kim, Hyeon-Seung;Gwon, Min-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.208-208
    • /
    • 2012
  • 최근 환경문제가 많이 제기되면서 친환경적 운송수단인 자전거 개발과 관련하여 다양한 기술개발이 이루어지고 있다. 그 중 고부가가치의 서스펜션 포크의 프레임에 고기능성 표면처리로 Arc ion plating deposition system (AIPDS)을 이용하여 부식, 내마모 특성이 뛰어난 TiN 박막을 증착시켰다. AIPDS는 기존의 arc system과 달리 다원계 소재 코팅 공정조건 확립을 위하여 chamber wall에 2개의 rectangular type sputter source를 장착하고 소재의 pre-treatment 용 linear type ion source를 설치하였다. 장비의 Chamber 중앙에는 pipe형 arc cathode를 설치하였으며, 그 주위를 anode 역할을 하는 copper 코일로 감아 이는 발생한 arc를 target인 cathode 축을 중심으로 방향성을 가지고 회전하여 진행 할 수 있도록 유도 하였다. 이 시스템에서 증착된 TiN 박막은 bias 전압 변화에 따른 박막의 구조 및 물성을 평가하였다. XRD 장비를 통하여 TiN 박막의 상분석을 진행하였고, 마모테스터, 원자현미경, 마이크로 비커스 경도기 등을 이용하여 기계적 특성을 평가하였다.

  • PDF