데이터센터의 합리적인 환경제어를 위한 장비 발열기준에 대한 연구 (A Study on a Heat-load of IT Equipments for the Thermal Environment Control in the Data Center)

  • 조진균;홍민호;정차수;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.938-943
    • /
    • 2006
  • The primary purpose of a computer room of data center and associated infrastructure is to support the operation of critical IT equipment. Traditionally, most owners of large critical data centers have been more than willing to accept a reasonable amount of computer room worker discomfort if necessary to support critical IT systems. All electrical equipment produces heat, which must be removed to prevent the equipment temperature from rising to an unacceptable level. Most information technology equipment and other equipment found in a data center or network room is air-cooled. Sizing a cooling system requires an understanding of the amount of heat produced by the equipment contained in the enclosed space, along with the heat produced by the other heat sources typically encountered.

  • PDF

발열량의 차이에 따른 Fire Whirl의 유동특성 (Flow Characteristics of Fire Whirl for Different Heat Release Rate)

  • 배승용;성건혁;유홍선;홍기배;김동현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.609-613
    • /
    • 2008
  • The fire whirl occurring by the instability of atmosphere is a rare phenomenon, but highly destructive because it has high inhalation and lift force, caused by the rotating velocity. And it is difficult to extinguish the fire, because of increment of the spread rate with the flame height. In this study, for investigation of the flow characteristic of fire whirl for various heat release rate, numerical analysis is performed in same conditions with experiments, using the FDS which is developed at NIST. For validating of the numerical study, the results are compared with the experiment. The result shows that the relation between the characteristic length and the ratio of circulation versus the buoyancy force is $z_f$/D$^{\ast}$ = 0.304(${\Omega}/{\alpha}$)^2 - 1.334${\Omega}/{\alpha}$ + 5.516.

  • PDF

Storage Vault의 열유동 및 상사특성 평가 (Evaluation of Thermal-hydraulic and Scaling Characteristics for Storage Vault)

  • 유승환;방경식;김동희;이관수
    • 방사성폐기물학회지
    • /
    • 제13권2호
    • /
    • pp.131-140
    • /
    • 2015
  • 본 연구에서는 저장볼트(storage vault)의 실험을 위하여 1/4 축소모델 내 튜브의 적정 발열량을 선정하고자 상사해석을 수행하였다. 저장볼트에 대한 열 및 유동 해석을 우선적으로 수행하였고, 크기를 1/4로 축소한 저장볼트에 대하여 동일한 전산해석을 수행하였다. 전산해석 결과를 바탕으로, 제안된 무차원수를 비교하여 원형모델과 온도분포와 유동분포가 유사하게 되는 발열량을 선정하였다. 1/4 축소 저장볼트 내 튜브의 열유속이 1.3배일 때, 원형 저장볼트와 1/4 축소 저장볼트의 온도장 및 유동장이 상사되었다. 이 때, 1/4 축소 저장볼트 내 발열량은 약 190 W이다.

FEMLAB을 이용한 리튬이온전지의 발열특성 평가모델링 (Evaluation Modeling Heat Generation Behavior for Lithium-ion Battery Using FEMLAB)

  • 이대현;윤도영
    • 청정기술
    • /
    • 제18권3호
    • /
    • pp.320-324
    • /
    • 2012
  • 본 연구에서는 리튬이온전지의 방전특성에 따른 열발생 속도를 계산하여 전지의 특성을 평가하였다. 이를 위하여 Butler-Volmer 식을 지배방정식으로 하여, 유사 2차원 모델링을 적용하고, 편미분 연산자인 FEMLAB을 이용하여 전산모사를 수행하였다. 전류밀도를 5 $A/m^2$에서 25 $A/m^2$까지 증가시켜 계산을 수행한 결과, 전류밀도가 증가함에 따라 전극표면에서 고체상 리튬의 소모량이 증가되는 것으로 나타났다. 이로 인한 확산제한의 발생시점이 단축되었으며, 동시에 리튬이온전지의 내부 전위가 컷오프 전위에 도달하는 시점에서 열발생 속도가 급격하게 증가되는 현상을 보여주었다.

자연공조를 활용한 무선기지국 Energy절감 제어시스템 (Energy saving control system of wireless base station utilizing natural air-conditioning)

  • 류구환;권창희
    • 디지털융복합연구
    • /
    • 제17권10호
    • /
    • pp.223-232
    • /
    • 2019
  • 정보통신 산업 발전에 따라 통신장치의 크기는 소형화 되고 발열량이 많이 발생하는 시스템으로 변화하고 있다. 그러므로 무선기지국에는 무선장비의 발열량이 많이 발생하여 에너지가 계속 많이 소모되고 있고 그로 인하여 무선기지국의 장애가 발생 할 우려가 있어 본 연구에서는 효율적이고 효과적인 방법으로 무선기지국내 에너지를 절감하고 기지국운영을 위하여 본 연구를 분석하게 되었다. 연구방법으로는 발열량 및 전기료를 많이 발생하는 기지국 대상으로 실시하였고 기지국 25개를 선정하여 2주간 데이터를 확보 하였다. 신뢰성을 확보하기 위해 실내 온도를 일정하게 $27^{\circ}C$로 유지 하였으며, 제어시스템을 설치하여 2주간 똑 같이 설치하여 date를 분석 확보 하였다. 연구방법에 있어 시험결과를 산출하기 위해 계측기는 전산전력계, 디지털온도계, 분진측정 등이 활용하였다. date분석을 위해 Control Sysetm 설치 전 date와 설치 후 date 분석을 위해 25개 무선기지국대상으로 연구 시험 하였다.

서버 컴퓨터의 발열량이 변화한 경우의 데이터센터 내의 기류 및 온도분포 특성에 대한 연구 (A Study on the Distribution of Airflow and Temperature in a Data center under the Various Conditions of Heat Generation Rates of Server Computers)

  • 장현재;김제영
    • 설비공학논문집
    • /
    • 제26권3호
    • /
    • pp.108-114
    • /
    • 2014
  • On a large scale of data center, heat generation rates from sever computers occupy almost the entire cooling load of the building, and it is gradually increasing. The efficiency of air distribution system in data centers can be affected by heat generation rates of server computers. In this study, the distributions of airflow and temperature in a data center have been investigated by CFD simulations under various conditions of heat generation rates for server computers. From the results, air around the cold aisle which has high temperature flows tremendously into the cold aisle according to the increase of heat generation rates for server computers and the air temperature in the cold aisle becomes higher. The SHI (supply heat index) and RHI (return temperature index) show almost similar values to the cases study because the air inflow rates to server computers increase with the heat generation rates of server computers.

전산해석을 통한 초본계 농업부산물의 합성가스 생산 특성 (Syngas production from pyrolysis and gasification of rice husks by simulation study)

  • 김수현;구재회;박용철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.249.1-249.1
    • /
    • 2010
  • 현재 농업부산 폐자원은 퇴비, 가축사료 등의 단순 활용이 대부분을 차지하고 있어, 열분해 가스화를 통한 고효율 에너지 이용 시스템 개발로 기존 단순 활용에 그치던 농업부산 폐자원의 고부가가치 이용이 절실히 필요한 실정이다. 본 연구에서는 초본계 농업부산물인 왕겨를 이용한 열분해 가스화 시스템에 대한 특성 파악 및 초본계 농업부산물을 이용한 에너지자원화 및 고효율 에너지 이용을 위한 방안을 모색하고자 다양한 조건에서 전산해석을 수행하였다. 공정해석에 사용된 왕겨는 수분함량 11.33%, 회분함량 10.66%, 가연분 함량, 78.01%의 조성으로, 발열량은 LHV 기준으로 3,729 kcal/kg 였다. 상용해석 프로그램을 사용하여 열분해로의 열손실, 투입되는 시료의 가스화 반응 비율 변화, 열분해 가스화 반응의 산화제로 사용되는 공기의 유량 변화에 따른 발생되는 가스의 유량, 성상, 온도 특성을 파악하였다.

  • PDF

원전콘크리트의 결합재 조성성분을 고려한 단열온도상승값 예측 모델 개발 (Modeling of the Adiabatic Temperature Rise of Concrete for Nuclear Power Plants With the Consideration of Binder Components)

  • 정상화;채성태;김도겸;문재흠
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2010년도 정기 학술대회
    • /
    • pp.758-761
    • /
    • 2010
  • 본 연구에서는 원전격납구조물과 같이 고품질의 대형 매스콘크리트의 설계, 시공, 품질예측 및 관리에 필요한 구조물 건전성 평가시스템 구축의 일환으로 수화열 예측 프로그램을 개발하였다. 개발된 수화열 예측 프로그램은 국내에서 생산된 시멘트 및 결합재의 화학조성성분, 분말도와 같은 기초정보 및 배합정보를 입력하여 경시변화에 따른 수화발열량을 계산하는 방식으로서 기존의 연구결과를 바탕으로 개발되었다. 개발된 프로그램은 배합환경조건을 고려하여 초기배합온도 3종류(10, 20, $30^{\circ}C$)로 실험한 단열온도상승 실험 결과와 비교해 보았으며, 좋은 상관성을 나타냄을 확인할 수 있었다.

  • PDF

공공부문 전력절감과 그린IT구현을 위한 데이터센터 내 열유동해석 (Flow and Thermal Analyses of Internet Data Center for Embodiment in Green IT)

  • 박상린;심장섭;송종철;문병주;박경우
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2010년도 춘계학술발표대회
    • /
    • pp.243-246
    • /
    • 2010
  • 최근 정보량의 급격한 증가로 데이터센터는 점차 대형화되고 있으며, 통합적으로 관리/운영되기 위해서는 전산실내 적절한 온도와 습도의 유지가 필수적이므로, 전산실내 에너지의 사용 효율을 극대화하기 위한 연구가 꾸준히 이루어지고 있다. 이 연구에서는 국내 공공부문의 대형 전산실을 모델로 선정하여 전산실 내 서버의 위치, 용량 그리고 냉각시스템 등을 고려하여 전산실내 열/유동특성을 수치적으로 규명함으로써, 에너지 효율 극대화를 추구하고 전력을 절감하여 저탄소 녹색성장과 그린IT 환경을 구축 하고자 한다. 이를 위하여 실제 측정한 환경 데이터를 바탕으로 전산유체역학(CFD)을 이용하여 3차원 비압축성, 정상상태의 열/유동특성을 예측한다. 또한 기존 및 개선된 전산실에 대한 비교결과를 바탕으로 새로운 열/유동조건을 도출하며, 이를 통하여 전산실 운영에 필요한 에너지 효율향상 방안을 제안하고자 한다. 연구 결과, 전산실 천장의 냉기유입부분과 열기배출부분으로 나뉘어 냉복도와 온복도를 형성하며, 내부 서버와 기타 각종 장비들의 발열 등으로 부분적인 열섬(Thermal island)현상이 나타났다. 이러한 열섬현상을 줄이고, 전산실내 환경을 최적화하기 위하여 찬공기 유입부분의 속도, 배출구의 유량, 그리고 냉/온 복도의 역할 변경 등 여러 가지 가능한 매개변수에 대한 연구가 필수적이다. 또한, 서버에서 발생한 고온의 공기를 배출하는 것이 전산실 내 적절한 온도구현에 효과적이며, 열섬현상을 방지하기 위해서는 이 부분에 차가운 공기의 유입이 필요하다는 것을 알 수 있었다.

효율성 증가를 위한 블록 단위 스마트 랙 기술 개발 (Block Smart Rack Technology Development for Increased Efficiency)

  • 태효식;박구락
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권4호
    • /
    • pp.11-16
    • /
    • 2015
  • 데이터센터는 전 세계적으로 클라우드 기반 IT 솔루션의 발전과 더불어 빅 데이터, 교육, 커뮤니케이션 수단의 발달과 전자기기 사용이 증가함에 따라 국내외로 그 수요가 꾸준히 증가하는 추세에 있다. 이러한 데이터센터의 증가는 IT장비의 발전을 가속화 시켰으며 서버 랙의 발열 또한 크게 높이는 결과를 가지고 왔다. 데이터 센터의 전산 발열량은 IT서버 전력사용의 99%이상이 열로 변환되므로, 서버의 크기와 용량이 증가할수록 발열량 또한 상승하게 된다. 본 논문에서는 공냉식 냉각방식을 중심으로, 데이터센터의 에너지 절감을 위한 공조시스템을 연구 하였으며, 해당 시스템의 성능분석 및 모의실험을 통하여 실제로 에너지 절감 효과가 있는 것으로 분석되었다.