Browse > Article
http://dx.doi.org/10.9708/jksci.2015.20.4.011

Block Smart Rack Technology Development for Increased Efficiency  

Tae, Hyo-Sik (Dept. of Computer Science and Engineering, Kongju National University)
Park, Koo-Rack (Dept. of Computer Science and Engineering, Kongju National University)
Abstract
Data center, not only the development of globally of cloud-based IT solutions, As the big data, education, use of development electronic equipment of communication means is increased, Demand of domestic and international data center has increased steadily. Due to the increase of data center demand, heat generation of server rack due to the development of IT equipment is also increasing continuously. Calculating heat value of the data center, because more than 99% of the power usage of IT server is converted into heat, the calorific value as the size and capacity of the server is larger will increase. In this paper, to center the cooling system of air-cooled, and research and development of air conditioning systems for energy reduction of data center, through performance analysis and simulation, it has been analyzed that there is energy savings.
Keywords
Smart Rack; Internet data center; Air-Cooled system;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 J.R. Turnpenny and D.W. Etheridge, "Novel ventilation cooling system for reducing air conditioning in buildings.: Part I: testing and theoretical modelling", Applied Thermal Engineering, Vol. 20, No. 11, pp. 1019-1037, Aug. 2000.   DOI   ScienceOn
2 C. D. Patel, C. E. Bash, R. Sharma, and M. Beitelmal, "Smart Cooling of Data Centers," In Proceedings of the Pacific RIM/ASME International Electronics Packaging Technical Conference and Exhibition (IPACK03), July 2003.
3 Hyo-Sik Tae, Young-Gi Yun, Koo-Rack Park, Jin-Mook Kim, Application of the In-Rack system and ventilation path for efficiency increase in datacenter cooling. Life Sci J 2014;11(10s):165-169]. (ISSN:1097-8135).
4 Hyo-Sik Tae, Koo-Rack Park, Han-Jin Cho, "Building the monitoring system for efficient operation of data computerized equipment." ICDPM 2015, Vol.2, No.1, pp.162-163, Jan.2015.
5 Cho, jin-Kyun, Park Woo-Pyoung, Shin, Seung-Ho, Lee,Jin-Young, Development of the Cooling Energy Analysis Tool for Green Data Centers and Evaluation of Alternatives for Different Climate, Vol.29, No7, Architectural Institute of Korea, 2013, pp.289-298
6 Jae-Kwon Bae, A Case Study on the Building of Green Internet Data Center for Green IT, Vol.12, No1. The e-Business Studies, 2011, pp329-248   DOI
7 San Murugesan, Harnessing Green IT : Principles and Practices, IT Pro, 2008, IEEE Computer Society, PP.24-33.
8 Kevin Dunlap, Neil Rasmuseen, Choosing Between Room, Row, and Rack-based Cooling for Data Centers, Schneider Electric-Data Center Science Center 2006, APC White Paper #130
9 J.G Koomey, Estimating Total Consumption by Server in the U.S and The World, 2007
10 Jae-Ung Cho, "A Flow Analysis on Wing Shape of Cooling Fan at Automobile", Journal of the Korea Convergence Society, Vol. 5, No. 4, pp. 75-79, 2014.   DOI
11 Young-Suk Chung, Rack-Koo Park, Jin-Mook Kim, "Study on predictive modeling of incidence of traffic accidents caused by weather conditions", Journal of the Korea Convergence Society, Vol. 5, No. 1, pp. 9-15, 2014.   DOI
12 Kang-Hun Lee, Dong-Il Kim, Dae-Ho Kim, Myung-Yoon Sung, Young-Kil Lee, Suk-Yong Jung, "Implementation of Real-Time Video Transfer System on Android Environment", Journal of the Korea Convergence Society, Vol. 3, No. 1, pp. 1-5, 2012.
13 Suk-Yong Jung, "Feedback Load Control Mechanism for Real-Time Web Services", Journal of the Korea Convergence Society, Vol. 1, No. 1, pp. 17-21, 2010.