• Title/Summary/Keyword: 전류용량

Search Result 687, Processing Time 0.024 seconds

An Evaluation Method for Short-Term Ratings of Double-Circuit Overhead Transmission Lines (2회선 가공송전선의 단시간정격에 관한 평가방법)

  • Kim, Sung-Duck;Sohn, Hong-Kwan;Jang, Tae-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.20-28
    • /
    • 2007
  • This paper describes an analytical method to determine the short-term ratings to reliably operate the overhead transmission lines with double-circuit lines when faulting one circuit of the two. As linearizing the thermal equilibrium equation that represents the temperature characteristic of conductors, we show that the linear equation can be easily represented the over-current and it's temperature property during overloading the one line. Generally, it is well hewn that the short-term line ratings should be determined by considering both conductor life and dip. However, most power companies have their own different guides for the short-term ratings. Using the suggested method in this paper, it can be re-accessed the short-term ratings given in Kepco's overhead transmission lines constructed during the past three different periods. As a result, it is verified that the short-term ratings could be increased mil efficiently. Furthermore, it would be directly applied the given method to determine the short-term dynamic line ratings when occurring faults in one of the double-circuit lines, without doing my other actions for the current lines.

Epoxy Planarization Films for the Stainless Steel Substrates for Flexible Displays (플렉시블 디스플레이용 Stainless Steel 기판의 에폭시 평탄막 연구)

  • Hong, Yong-Teak;Jung, Seung-Joon;Choi, Ji-Won
    • Polymer(Korea)
    • /
    • v.31 no.6
    • /
    • pp.526-531
    • /
    • 2007
  • This paper reports the first results of a series of planarization film study for the stainless steel (SS) substrates for flexible displays. Diglycidyl ether of bisphenol A (DGEBA) and octa(dimethylsiloxypropylglycidylether) silsesquioxane (OG) were chosen for the organic and the hybrid epoxies respectively and diaminodiphenylmethane (DDM) was used as a curing agent at 1:2 stoichiometric ratio. These materials were spin-coated on SS substrates and thermal-cured. TGA study indicated that both the pristine and the cured OG were more thermally stable than DGEBA. AFM study showed that the smooth surfaces of $1{\sim}2\;nm$ roughness can be prepared for both DGEBA and OG when the films were thick ($>\;1\;{\mu}$). The electrical properties such as dielectric constant, capacitance and the leakage current with respect to the applied voltage were all stable even after the stress of $100\;V/100^{\circ}C$ was applied for $0{\sim}10000$ seconds indicating that the insulating properties of DGEBA and OG films were very reliable.

Electrochemical Properties of Polypyrrole/Polyfuran Polymer Composite Electrode (피롤/퓨란 고분자 복합체 전극의 전기화학적 성질)

  • Cha, Seong Keuck
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.664-671
    • /
    • 1998
  • Poly pyrrole polymer(ppy) has an excellent electrical conductivity and can be easily polymerized on anode to give various morophology according to doped anion on electroactive sites. To improve the properties of brittleness, ageing and hydrophobisity, poly furan polymer(pfu) having a high initiation potential was anodically implanted in this porous ppy film matrix to get the Pt/ppy/pfu(x)type of polymer composite electrode. Cyclic voltammetry and electrochemical impedance methods were used to these electrode, where $PF_6^-,\; BF_4^-$, and $ClO_4^-$ ions were employed as dopants. The composition of the pfu(x) at the electrode was changed from 0 to 1.10, but the range was useful only at 0.1 to 0.2 as the redox electrode. The polymer composite electrode doped with $PF_6^-$ was better in charge transfer resistance by a factor of 40 times and in double layer capacitance by a factor of 20 times than others. The charge transfer in the polymer film of the electrode was influenced on frequency change and equivalent circuit of this electrode had Warburg impedance including mass transfer.

  • PDF

Principles and Comparative Studies of Various Power Measurement Methods for Lithium Secondary Batteries (리튬이차전지 출력측정법의 원리 및 측정법간 비교 연구)

  • Lee, Hye-Won;Lee, Yong-Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.115-123
    • /
    • 2012
  • As the market of lithium secondary batteries moves from mobile IT devices to large-format electric vehicles or energy storage systems, the strengthened battery specifications such as long-term reliability longer than 10 years, pack-level safety and tough competitive price have been required. Moreover, even though high power properties should also be achieved for hybrid electric vehicles, it is not easy to measure accurate power values at various conditions. Because it is difficult to choose a proper measurement method and its experimental condition is more complex comparing to capacity measurement. In addition, the power values are very sensitive to power duration time, state-of-charge (SOC) of cells, cut-off voltages, and temperatures, whereas capacity values are not. In this paper, we introduce three kinds of power measurement methods, hybrid pulse power characterization (HPPC) suggested by US FreedomCar, so-called J-pulse by Japan electric vehicle association standards (JEVS) and constant power measurement, respectively. Moreover, with pouch-type unit cells for HEV, experimental power data are discussed in order to compare each power measurement.

A study on Lifetime Evaluation of High-power Cables Based on Temperature Changes (온도변화에 따르는 고전력 케이블의 수명 변화 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.273-278
    • /
    • 2015
  • In order to meet increasing power demands, electrical capacity of equipment for power transfers should become larger accordingly. The equipment used for producing and delivering high-voltage power is also required to operate with a high degree of reliability. The stable operation of power equipment is a necessity, not an option. The current through the power cable, the only device to deliver high power, generates a Joule heat, which causes a deteriorating process on the cable system. The XLPE cable is manufactured in such a manner that it can operate for 30 years at $90^{\circ}$, but there is no guarantee that each cable will reach its projected lifetime of 30 years. In this paper, we have measured the temperatures of nine power cables in operation, based on the theory of cable longevity. In order to study the relationship between temperature and longevity, we have devised a new set of equipment and installed it at Korea Western Power Co., Ltd. located in Taean.

A Delta Modulation Method by Means of Pair Transistor Circuit (쌍트랜지스터 회로에 의한 정착변조방식)

  • 오현위
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.2
    • /
    • pp.24-33
    • /
    • 1971
  • A noble method of delta modulation by means of pair transistor circuit having negative resistance charcteristic is presented. An RC parallel circuit is inserted between two eiuitter tarminals of the pair transistor circuit, and their emitters are driven by a square pulsed current source. Basically this is a relaxation oscillator circuit. But when the value of capacitors and resistanc R, and the pulse height of driving source are properly chosen, the RC parallel circuit apparently functions as integrating circuit of driviving pulses. Compared with the integrated voltage of capacitor C, a signal input voltatage supplied in series with RC parallel circuit between two emitters makes on or off either of the pair transistors. as the result, one bit pulse is sent out from the coupling resistance terminal of conducted transistor. The circuit diagram used for this experiment is presented, it i% composed with simple mod ulster circuit, differential amplifier and pulse shaping amplifier, The characteristics of the components of this ciruit are discussed, and especially quantumized noise in this delta modulation system is discussed in order to improve the signal to noise ratio which has a close relation with circut constants, quantumized voltage, pulse height and width of driving current source.

  • PDF

A Study on the Improvement for a Defect Diagnosis of Track Circuit on HSL (고속선 궤도회로 결함진단을 위한 개선방안 연구)

  • Park, Ki-Bum;Lee, Tae-Hoon;Lee, Gi-Chun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1656-1664
    • /
    • 2007
  • This paper introduces a study of improvement for a defect diagnosis of the UM71C track circuit using on HSL. The track circuit on HSL has long operation section. Therefore, when the worker maintain, many times and efforts are spent. So, periodically, we have operated a inspection car. However, we don't know exactly the state changed of the inspection data when track circuit has defect. Actually, We fixed a sample area within operation section on HSL and performed the simulations for short circuit current that is reflected characteristic impedance and propagation factor. We compared the measuring data with the result of the simulation. Using verified simulation program, we estimated inspection data as the malfunction number and the change of capacity of compensation capacitor. These study need to secure of the safety as the train operation. Also, It needs to make a criteria of analysis for the maintenance through comparison simulation data and inspection data.

  • PDF

Anaysis of Small-sized Power Connectors for Mobile Device Batteries (모바일기기 배터리용 초소형 파워 커넥터 해석)

  • Lee, Keun-Myoung;Oh, Ung;Yoo, Sung-Kyu;Song, Byeong-Suk
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.101-109
    • /
    • 2015
  • As the number of smartphone users grows, number of applications and the expected overall functionality in a smartphone grow simultaneously. With ever-so increasing expectations comes intense competition to squeeze in myriads of functions in a limited space that is only getting 'slimmer' by the year. In order to achieve this, companies often decrease the size of components in smartphones - battery connectors in particular. While they may fit, smaller battery connectors have their disadvantages due to the heat generated by the high current flow in the circuits. In collaborating with Korea's leading battery connector manufacturers, this research presents current issues and design concepts that should be considered when engineers design power connectors based on their electrical and thermal analysis.

A Study on the Evaluation of the Impact of Power System according to the Connection of Renewable Energy (신재생 전원 계통 접속에 따른 전력계통 영향 평가에 관한 연구)

  • Park, Seoung-Jun;Cho, Yun-Sung;Hur, Jin;Park, Sang Ho;Yoon, Gi Gab
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.733-737
    • /
    • 2018
  • In this paper, we describe the effects on the power system by adding renewable generator. In order to examine the stability of the system, the system analysis was performed using the PSS/E software. We confirmed whether occur the line overload of system through the load flow analysis and contingency analysis. and confirmed whether exceed of fault current using the fault current analysis. Dynamic stability of the system is analyzed through dynamic simulation. The analysis of the system according to the addition of the renewable generator was carried out according to the power system reliability and electricity quality maintenance standard.

Efficient Fault Location Detecting Mechanism for Optical Submarine Cable (해저광케이블 고장지점 탐지기법)

  • Park, Hong-Tae;Yoo, Jae-Duck;Yoon, Suk-Min;Jo, Gi-Rayng;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • The optical submarine cable has a long distance cable and the repeater for optical amplification compared to territorial optical cable so conventional OTDR utilization for the optical submarine cable is limited. in case the optical core in the optical submarine cable system cut, by using Coherent OTDR that utilize OTDR path in repeater the cable fault point can be detected and in case the faulty of the copper tube in the cable that provide power for the repeater to amplify optical signal, the ways using the current/voltage characteristic, the capacitance per Km and so on is required. this report suggest efficient fault location detecting mechanism by categorized cable fault type.

  • PDF