• Title/Summary/Keyword: 전기IT

Search Result 23,929, Processing Time 0.057 seconds

An Analysis of Cold Gas Flow-Field for UHV Class Interrupters (초고압 가스차단부의 냉가스 유동해석)

  • Song, Gi-Dong;Park, Gyeong-Yeop;Song, Won-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.387-394
    • /
    • 2000
  • This paper presents a method of cold gas flow-field analysis within puffer type GCB(Gas Circuit Breaker). Using this method, the entire interruption process including opening operation of GCB can be simulated successfully. In particular, the distortion problem of the grid due to the movement of moving parts can be dealt with by the fixed grid technique. The gas parameters such as temperature, pressure, density, velocity through the entire interruption process can be calculated and visualized. It was confirmed that the time variation of pressure which was calculated from the application of the method to a model GCB agreed with the experimental one. Therefore it is possible to evaluate the small current interruption capability analytically and to design the interrupter which has excellent interruption capability using the proposed method. It is expected that the proposed method can reduce the time and cost for development of GCB very much. It also will be possible to develop the hot-gas flow-field analysis program by combining the cold-gas flow field program with the arc model and to evaluate the large current interruption capability.

  • PDF

$NO_x$ Sensing Characteristic of $TiO_2$ Thin Film Deposited by R.F Magnetron Sputtering (R.F 마그네트론 스퍼트링으로 작성된 $TiO_2$박막의 $NO_x$ 감지 특성)

  • 고희석;박재윤;박상현
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.12
    • /
    • pp.567-572
    • /
    • 2002
  • In these days, diesel vehicle or power plant emits $NO_X\; and SO_2$ which cause air pollution like acid-rain, ozone layer destroy and optical smoke, therefore there are many kinds of methods considered for removing them such as SCR, catalyst, plasma process, and plasma-catalyst hybrid process. T$TiO_2$ is commonly used as catalyst to remove $NO_X$ gas because it have very excellent chemical characteristic as photo catalyst. In this paper, $NO_X$ sensing characteristic of $TiO_2$ thin film deposited by R.F Magnetron sputtering is investigated. A finger shaped electrode on $Al_2$O$_3$ substrate is designed and $TiO_2$ is deposited on the electrode by the magnetron sputtering deposition system. Chemical composition of the deposited $TiO_2$ thin film is $TiO_{1.9}$ by RBS analysis. When the UV is irradiated on it with flowing air, capacitance of $TiO_2$ thin film increases, however, when NO gas is put into the system with air, it immediately decreases because of photo chemical reaction. and it monotonously decreases with increasing NO concentration.

A Electron-Transfer Study on Self-Assembled Viologen Monolayer In different Electrolytes Using Electrochemical Process (전기화학법을 이용한 전해질 변화에 따른 Viologen 자기조립박막의 전하이동 특성 연구)

  • Lee, Dong-Yun;Park, Sang-Hyun;Shin, Hoon-Kyu;Park, Jae-Chul;Chang, Jeong-Soo;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.878-881
    • /
    • 2004
  • When it converted solar energy or light energy into chemical energy, it studied the electric charge transfer property of the viologen which is used widely as the electron acceptor for the electric charge delivery mediation of the devices. It was formed monolayer in QCM by self-assembled viologen. The absorbed quantities of viologen's electron through peak current and to analyze the electron transfer property of viologen in redox reaction made experiments in cyclic voltammetry among the electrochemical process. It studied the electron transfer relation of viologen from changing the anion in 0.1M NaCl and $NaClO_4$ electrolyte and the interrelation between scan rate and peak current when scan rate increased twice.

  • PDF

Luminance Properties and Electrical Properties by Applied Frequency of External Electrode Fluorescent Lamp(EEFL) (EEFL의 주파수 변화에 따른 전기적 특성과 휘도특성)

  • Lee, Seong-Jin;Lee, Jong-Chan;Park, Noh-Joon;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.355-360
    • /
    • 2007
  • The recent TFT-LCD Trend that is done large size gradually. As size of monitor great, though problem happens, it is that consumer's request which it makes monitor combined TV function. Monitor and TV are no difference externally greatly, but define difference happens as for backlight. An external electrode fluorescent lamp (EEFL) has an advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Researches on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high Luminance using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, EEFL presented the possibility of using it as a light source for back-lights. However, because EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verified the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell electromagnetic field simulation and examined the relationship between the change in the EEFL frequency and Luminance by measuring the optical characteristics.

A Study on the Human body Model shocked Electric installation in Underwater (수중에서의 인체에 가해지는 전기적 현상에 관한 연구)

  • Woo, J.H.;Park, H.Y.;Song, W.C.;Kim, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1338-1339
    • /
    • 2008
  • In this paper, charging part by basic from Andrew's body model research to second a danger have affect on remaining and rehabilitation humans in space under water. The construction of a circuit make to Andrew's body model. It compare that voltages measure a hand, a breast, a groin and electric currents measure an arm, a breast, a leg with safety a limit of body through an electric current. Out of result, it research that magnitude and wave of body passing an electric current give the effect to the heart control a signal and it have affect on direct the ventricle of the heart in detail motion. A thing of this sort get through to the simulation by the ATP-Draw program. The results from above, it is publish one's research work with safety a limit electric angle take measurement of resistance a body in under water and to the voltage and electric current passing each parts.

  • PDF

Analysis of Electrical Characteristics According to the Pillar Spacing of 4.5 kV Super Junction IGBT (4.5 kV급 Super Junction IGBT의 Pillar 간격에 따른 전기적 특성 분석)

  • Lee, Geon Hee;Ahn, Byoung Sup;Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.173-176
    • /
    • 2020
  • This study focuses on a pillar in which is implanted a P-type maneuver under a P base. This structure is called a super junction structure. By inserting the pillar, the electric field concentrated on the P base is shared by the pillar, so the columns can be dispersed while maintaining a high breakdown voltage. Ten pillars were generated during the multi epitaxial process. The interval between pillars is varied to optimize the electric field to be concentrated on the pillar at a threshold voltage of 6 V, a yield voltage of 4,500 V, and an on-state voltage drop of 3.8 V. The density of the filler gradually decreased when the interval was extended by implanting a filler with the same density. The results confirmed that the size of the depletion layer between the filler and the N-epitaxy layer was reduced, and the current flowing along the N-epitaxy layer was increased. As the interval between the fillers decreased, the cost of the epitaxial process also decreased. However, it is possible to confirm the trade-off relationship that deteriorated the electrical characteristics and efficiency.

Test Case Automatic Generation for Fault Localization (결함 위치 추적을 위한 테스트 케이스 자동 생성 기법)

  • Park, Changyong;Kim, Junhee;Ryu, Sungtae;Youn, Hyunsang;Lee, Eunseok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.1235-1238
    • /
    • 2012
  • 오늘날 소프트웨어가 가지는 규모와 복잡성은 날로 심화되고 있으며, 소프트웨어 개발 시 결함을 찾아 내기 위한 테스트에 많은 시간이 소모되고 있는 실정이다. 이러한 문제점을 해결하기 위해 중요한 기술 중 하나가 결함 위치 추적(Fault Localization)이다. 이 기법을 이용하여 결함을 추적하기 위해서는 다량의 테스트 케이스를 필요로 하며, 추가로 테스트 케이스를 작성하는 것은 또 다른 개발 부하이다. 본 논문에서는 이를 해결하기 위해서 분기별 입력 조합 기반 테스트 케이스 생성방법과 시드 결과 기반 테스트 케이스 생성방법을 제안하였다. 개발자는 본 생성방법을 통해 테스트 케이스 생성에 대한 비용 절감을 기대 할 수 있다. 제안하는 내용의 효용성을 검증하기 위해 실제 예제 코드에 적용하여 평가하였다. 두 가지 방법 모두 무작위 생성한 테스트 케이스에 비해 개발자가 직접 생성하는 것과 유사한 테스트 케이스를 생성하고, 제안 방법으로 생성한 테스트 케이스의 신뢰성을 확인하였다.

A Study about the Necessity of Cooperation in Technologies for Small Electric Vehicles in Major ASEAN Countries (소형 전기 상용차산업의 아세안 지역 적용 연구)

  • LIM, JAE WAN;WON, JANG HYEOK;LEE, CHUN BEOM;LIM, OCK TAECK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.4
    • /
    • pp.271-276
    • /
    • 2021
  • Although the development of electric vehicles or electric commercial vehicles is underway in Korea, most companies are seeking to enter the global market because it is difficult to expand their business only in the domestic market. In addition, it is recognized that the country has difficulties in responding to regulations or related procedures when entering overseas markets, and due to such difficulties, it is not possible to gain opportunities to enter the market and gain the technical advantage. Therefore, it is necessary to support individual companies to overcome the difficulties of promoting and exporting products by establishing a pre-cycle support environment for technology development so that development parts can be installed in small electric commercial vehicles. Therefore, this study tried to understand the necessity and factors of small electric commercial vehicles for major ASEAN countries, and as a result, most of them raised the urgency and necessity of joint research.In addition, human resource development, government support, and technical support were suggested as the necessary factors for the study.

Thermal Distribution Analysis in Nano Cell OLED (나노 셀 OLED의 열 분포 해석)

  • Kyung-Uk Jang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.309-313
    • /
    • 2024
  • The key to determining the lifetime of OLED device is how much brightness can be maintained. It can be said that there are internal and external causes for the degradation of OLED devices. The most important cause of internal degradation is bonding and degradation in the excited state due to the electrochemical instability of organic materials. The structure of OLED modeled in this paper consists of a cathode layer, electron injection layer (EIL), electron transport layer (ETL), light emission layer, hole transport layer (HTL), hole injection layer (HIL), and anode layer on a glass substrate from top to bottom. It was confirmed that the temperature generated in OLED was distributed around the maximum of 343.15 K centered on the emission layer. It can be seen that the heat distribution generated in the presented OLED structure has an asymmetrically high temperature distribution toward the cathode, which is believed to be because the sizes of the cathode and positive electrode are asymmetric. Therefore, when designing OLED, it is believed that designing the structures of the cathode and anode electrodes as symmetrically as possible can ensure uniform heat distribution, maintain uniform luminance of OLED, and extend the lifetime. The thermal distribution of OLED was analyzed using the finite element method according to Comsol 5.2.

A Study on the Detection of Indication of Accident in Electric Equipments with Incandescent Lamps Using Current Monitor (전류 모니터를 이용한 백열등 부하 전기설비에서 사고 징후 검출에 관한 연구)

  • Jee, Seung-Wook;Ok, Kyung-Gea;Kim, Shi-Kuk;Lee, Chun-Ha;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.109-115
    • /
    • 2009
  • This paper describes an early detection for indication of electric accident using current waveform which is measured in electric equipments consisted incandescent lamps. At first, it analyzes characteristics of current monitor in resistive electric circuit. In second, the electric equipment is consisted of incandescent lamps. And the electric accident is simulation of tracking according to KS C IEC(Korea Standard C International Electrostatic Commission) 60112 at some part of the electric equipment. The indication of the electrical accident is detected to analyzing current waveform measured by current monitor. As the tracking breakdown, electric accident, processes, as current pulse is bigger and ratio of appearance also is increased irrespective of amount of load.