• Title/Summary/Keyword: 전기IT기기

Search Result 715, Processing Time 0.029 seconds

MXene Based Composite Membrane for Water Purification and Power Generation: A Review (정수 및 발전을 위한 맥신(MXene) 복합막에 관한 고찰)

  • Seohyun Kim;Rajkumar Patel
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.181-190
    • /
    • 2023
  • Wastewater purification is one of the most important techniques for controlling environmental pollution and fulfilling the demand for freshwater supply. Various technologies, such as different types of distillations and reverse osmosis processes, need higher energy input. Capacitive deionization (CDI) is an alternative method in which power consumption is deficient and works on the supercapacitor principle. Research is going on to improve the electrode materials to improve the efficiency of the process. A reverse electrodialysis (RED) is the most commonly used desalination technology and osmotic power generator. Among many studies conducted to enhance the efficiency of RED, MXene, as an ion exchange membrane (IEM) and 2D nanofluidic channels in IEM, is rising as a promising way to improve the physical and electrochemical properties of RED. It is used alone and other polymeric materials are mixed with MXene to enhance the performance of the membrane further. The maximum desalination performances of MXene with preconditioning, Ti3C2Tx, Nafion, and hetero-structures were respectively measured, proving the potential of MXene for a promising material in the desalination industry. In terms of osmotic power generating via RED, adopting MXene as asymmetric nanofluidic ion channels in IEM significantly improved the maximum osmotic output power density, most of them surpassing the commercialization benchmark, 5 Wm-2. By connecting the number of unit cells, the output voltage reaches the point where it can directly power the electronic devices without any intermediate aid. The studies around MXene have significantly increased in recent years, yet there is more to be revealed about the application of MXene in the membrane and osmotic power-generating industry. This review discusses the electrodialysis process based on MXene composite membrane.

A Study on the Induced Voltages on Subscriber Telecommunication Lines from High-Speed Electrified Railway Line (고속전철에 의한 통신선로 전력유도 현상에 관한 고찰)

  • Oh, Ho-Seok;Kang, Seong-Yong;Yun, Ju-Yeong;Kim, Hak-Chul;Choi, Kyung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.10
    • /
    • pp.71-79
    • /
    • 2008
  • This paper analyzed the voltage induction phenomena on the telecommunication lines by electromagnetic coupling from high-speed A.C. electrified railway. The induced common mode voltages and the induced differential mode voltage on the telecommunication line was measured by notified standard method in the regulation of Korea. The test lines consist of 2 separated lines of 20 m and 300 m in influence distance each for comparison, with 2km inducing length. The analysis is made on the induced voltages from the different influence distances and the different earthing points, and also on the waveform and spectrum distributions. It is proved that the induction is arisen so good and the measured values are fair enough against noise such as the earth voltage differencing, and the current measuring scheme is also rightful.

A Study on Remote Fault Diagnosis System of Special-purposed Vehicle (특수목적용 차량의 원격 고장진단 시스템에 대한 연구)

  • Pyo, Se Young;Kim, Kee Hwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.3
    • /
    • pp.221-226
    • /
    • 2018
  • Special-purposed vehicles are customized according to the user's requirements. When these vehicles are out of oder, they are costly and time consuming to repair. In order to solve these problems, we want to remotely check whether the vehicle is abnormal and remotely identify the fault area, thereby shortening the repair cost and the repair period. In this study, the faulty part of the electric control part is automatically identified, and it is immediately grasped through the user's mobile phone application and an instant fault code is notified to the car manufacturer for quick and smooth fault repair. In order to realize this, we want to build a system that uses the technology of IoT to determine the fault area according to the items required in the field of the special purpose vehicle and notify the manufacturer of the fault on its own.

Subjective Video Quality Comparison of 3D Display Monitors (3D 디스플레이 모니터의 주관적 화질 상관도 비교)

  • Youn, Sungwook;Ok, Jiheon;Yim, Donghyun;Han, Taehwan;Lee, Chulhee
    • Journal of Broadcast Engineering
    • /
    • v.18 no.3
    • /
    • pp.416-424
    • /
    • 2013
  • Recently, efforts have been made to develop international standards related to 3DTV quality assessment underway in International Telecommunication Union and Video Quality Experts Group. Unlike conventional 2D displays, there are several types of 3D display monitors: passive glasses, active glasses and auto-stereoscopic. In this paper, we performed subjective video quality tests using various 3D display monitors, in order to examine whether these display monitors can produce consistent perceptual video quality scores for processed video sequences. The experimental results show that the subjective scores of those 3D monitors are highly correlated and it appears that similar subjective scores will be obtained even when different types of 3D displays are used.

Arc Discharge Sensor having Noise Immunity to Ambient Light (주변광 영향을 받지 않는 아크방전 감지 센서)

  • Roh, Hee Hyuk;Seo, Yong Ma;Khishigsuren, J.;Choi, Kyoo Nam
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.726-728
    • /
    • 2013
  • Optoelectronic arc discharge sensor was used to detect arc discharge inside power distribution panel. Arc discharge is fatal to power system once it begins, thus preventive detection is necessary before power failure occurs. Optoelectronic detection method was used to avoid direct electrical contact to power apparatus inside power distribution panel. 180 degree detection angle and detection range far exceeding 6m, which was sufficient for monitoring purpose, was achieved using the photodiode having $7.5mm^2$ of active surface area and flash source with $0.4cal/cm^2$ energy density, which is equivalent to 1.9J with $2.16cm^2$ emitting area. The response speed of arc discharge sensor was measured to be below 1 msec. The above optoelectronic arc discharge sensor was measured to be sensitive enough to detect 0.94 pC charge.

  • PDF

Effects of E-Learning as a Supplementary Learning for Basic Fluid Power Practice (유공압기초실습의 보완학습으로서 E러닝의 효과)

  • Huh, Jun-Young;Jeong, Seong-Won
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.2 no.2
    • /
    • pp.10-15
    • /
    • 2010
  • The subject of basic fluid power practice which is used in various industries requiring factory automation aims at understanding of the composition and operating principles of pneumatic components and programming of electric sequential circuits, building the design ability of pneumatic system. This subject goes by 3 hour classes with theory and practice side by side. So it is not enough time to instruct students various contents related in this subject. In this research a supplementary learing using E-learning is proposed as a solution for this problem. The off-line classes of this subject went with E-learning side by side and analyzed the effects of E-learning as a supplementary learning through the students survey who attended the class. And further needed research is presented.

  • PDF

Modeling and Analysis of DC Based Buildong Power Structure (직류기반 소용량 건물 전력계 모델링 및 해석)

  • Baek, Jong-Bok;Seo, Gab-Su;Park, Chul-Woo;Bae, Hyun-Su;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.238-239
    • /
    • 2010
  • 주거 상업용 건물에 있어 최근 TV, LED 조명, 컴퓨터, IT 기기들과 같은 직류를 사용하는 부하가 점차 증가함에 따라 기존의 교류 배전 기반의 건물 전력구조에서 에너지절감을 위한 하나의 방안으로 직류기반의 건물 배전구조에 대한 도입에 대한 연구가 활발히 이뤄지고 있다. 또한 직류 형태의 전원인 태양광 발전, 연료전지 등의 신재생 에너지와 가정 및 전기자동차용 배터리의 등장은 직류 기반 전력구조가 가지는 강점을 더욱 부각시키고 있다. 직류 배전 시스템은 기존 교류 배전에서 직류부하를 위한 다중의 전력 변환 과정을 최소화함으로서 전원 및 부하에서 소모되는 에너지를 절감하여 전력시장 내 전체적인 탄소배출량 저감에 기여할 수 있을 것으로 고려되어지고 있다. 이는 직류배전 시스템의 에너지 저감 효용성 이외 기존 교류배전 대비 부하단 부품 수의 감소에 따른 신뢰성 향상 및 가격 저감, 무효전력 고려사항의 제거 등 많은 장점을 가지기 때문이다. 본 논문에서는 소용량 건물에 직류배전 구조가 도입될 경우 실현 가능성이 높은 대표적 직류 배전 구조들을 Functional Modeling 기법을 통해 모델링하며, 시뮬레이션을 통해 기존의 교류 배전 건물과 함께 각각의 전력계 구조에 대한 효율 및 장단점들을 정성적으로 비교하고, 구현에 필요한 고려사항들을 제시한다.

  • PDF

Simultaneous analysis of glucocorticoids in bovine muscle and liver by LC-MS/MS (LC-MS/MS를 이용한 소의 근육과 간 중에 잔류하는 glucocorticoids 동시 분석)

  • Shin, Sang-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.405-413
    • /
    • 2010
  • A new method for the simultaneous determination of six glucocorticoids (betamethasone, dexamethasone, prednisone, prednisolone, methylprednisolone, and flumethasone) in meats (bovine muscle, bovine liver) were established. Samples were effectively extracted using C18 cartridge with ethylacetate. Chromatographic separation was achieved using C18 column and negative electrospray ionization mass spectrometry was performed in the Multiple Reaction Monitoring mode for the effective quantitation and qualification of glucocorticoids. Acetonitrile and water (0.1% formic acid) were used as mobile phase and additive for effective electrospray ionization, and gave good chromatographic separation and mass spectrometric sensitivity. The limit of detection (LODs) and the limit of quantitation (LOQs) in spiked blank samples depending on types of matrix and pharmaceuticals were ranged from 0.2 to $1.0\;{\mu}g$/kg and 0.8 to $3.4\;{\mu}g$/kg, respectively. And the recoveries were between 89.5 to 119.6%. The established method showed good recoveries, accuracies, precisions and fast sample preparation and it will be applied to assay of glucocorticoids residues in meat.

Rechargeable Zn-air Energy Storage Cells Providing High Power Density (고출력.고에너지 밀도의 아연금속-공기전지)

  • Park, Dong-Won;Kim, Jin Won;Lee, Jae Kwang;Lee, Jaeyoung
    • Applied Chemistry for Engineering
    • /
    • v.23 no.4
    • /
    • pp.359-366
    • /
    • 2012
  • Zn-Air energy storage cell is an attractive type of batteries due to its theoretical gravimetric energy density, cost-effective structure and environmental-friendly characteristics. The chargeability is the most critical in various industrial applications such as smart portable device, electric vehicle, and power storage system. Thus, it is necessary to reduce large overpotential of oxygen reduction/evolution reaction, the irreversibility of Zn anode, and carbonation in alkaline electrolyte. In this review, we try to introduce recent studies and developments of bi-functional air cathode, enhanced charge efficiency via modification of Zn anode structure, and blocking side reactions applying hybrid organic-aqueous electrolyte for high power density rechargeable Zn-Air energy storage cells.

Repair and Replacement Methodology for Electrical Equipment Used in Nuclear Power Plants (원자력발전소 전기기기의 보수, 교체 방법론)

  • Park, Chulhee;Park, Wan-gyu;Lee, Manbok;Kim, Choon-sam
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.177-179
    • /
    • 2018
  • After Fukushima nuclear accident at 2011, nuclear industrial has been focused on operation and maintenance phase, not design and construction phase. Continued good operating performance of nuclear power plants has been the best critical issue to nuclear utilities. Replacement for complete components as well as parts of components is being procured because nuclear utilities must maintain safety and reliability of operating nuclear power plants. However, many suppliers and manufacturers are giving up a nuclear quality assurance program under reduction in new construction of nuclear power plants. It is able to be increased difficulty in procuring spare parts to support operations and maintenance of nuclear power plants. Over 20% of nuclear power plant equipment in some countries is obsolete. Owing to obsolescence of nuclear safety-related items and/or withdrawing a nuclear quality assurance program of suppliers and manufactures, some replacement item and part might be procured to the item not covered by appendix B to USNRC 10 CFR Part 50. Under various methods of the nuclear repair and replacement methodology, utilities are supposed to establish a typical program for a repair and replacement of an electrical equipment and its parts in conjunction with a nuclear quality assurance. Concerning this typical program, this study suggests the repair and replacement methodology of electrical equipments used in nuclear power plants by procurement of a power supply, based on nuclear regulations, codes, standards, guidelines, specific and general technical information, etc..

  • PDF