• Title/Summary/Keyword: 전기침투

Search Result 250, Processing Time 0.029 seconds

Application of Porous Nanofibers Comprising Hollow α-Fe2O3 Nanospheres Prepared by Applying Both PS Template and Kirkendall Diffusion Effect for Anode Materials in Lithium-ion Batteries (커켄달 효과와 주형법을 통해 합성한 α-Fe2O3 중공입자로 구성된 다공성1차원 구조체의 리튬 이차전지 음극활물질 적용)

  • Lee, Young Kwang;Jeong, Sun Young;Cho, Jung Sang
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.819-825
    • /
    • 2018
  • Porous nanofibers comprising hollow ${\alpha}-Fe_2O_3$ nanospheres were prepared by applying both template method and Kirkendall diffusion effect to electrospinning process. During heat-treatment processes, the solid Fe nano-metals formed by initial heat-treatment in the carbon matrix were converted into the hollow structured ${\alpha}-Fe_2O_3$ nanospheres. In particular, PS nanobeads added in the spinning solution were decomposed and formed numerous channels in the composite, which served as a good pathway for Kirkendall diffusion gas. The resulting porous nanofibers comprising hollow ${\alpha}-Fe_2O_3$ nanospheres were applied as an anode material for lithium-ion batteries. The discharge capacities of the nanofibers for the 30th cycle at a high current density of $1.0A\;g^{-1}$ was $776mA\;h\;g^{-1}$. The good lithium ion storage property was attributed to the synergetic effects of the hollow ${\alpha}-Fe_2O_3$ nanospheres and the interstitial nanovoids between the nanospheres. The synthetic method proposed in this study could be applied to the preparation of porous nanofibers comprising hollow nanospheres with various composition for various applications, including energy storage.

Synthesis of Pt-Bi/Carbon Electrodes by Reduction Method for Direct Methanol Fuel Cell (환원법에 의한 직접 메탄올 연료전지(DMFC)용 Pt-Bi/Carbon 전극제조)

  • Kim, Kwan Sung;Kim, Min Kyung;Noh, Dong Kyun;Tak, Yongsug;Baeck, Sung-Hyeon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.479-485
    • /
    • 2011
  • Pt-Bi/C catalysts supported on carbon black with various Pt/Bi ratios were synthesized by a reduction method. Chloroplatinic acid hydrate ($H_2PtCl_6{\cdot}xH_2O$) and bismuth (III) nitrate pentahydrate ($Bi(NO_3)_3{\cdot}5H_2O$) were used as precursors for Pt and Bi, respectively. Before loading metal on carbon, heat treatment and pretreatment of carbon black in an acidic solution was conducted to enhance the degree of dispersion. The physical property of the synthesized catalysts was investigated by X-ray diffraction and X-ray photoelectron spectroscopy. The XRD pattern of untreated Pt-Bi/C catalyst showed BiPt and $Bi_2Pt$ peaks in addition to Pt peaks. These results imply that Bi atoms were incorporated into the Pt crystal lattice by Pt-Bi alloy formation. The catalytic activity for methanol oxidation was measured using cyclic voltammetry in a mixture of 0.5 M $H_2SO_4$ and 0.5 M $CH_3OH$ aqueous solution. The addition of proper amount of Bi was found to significantly improve catalytic activity for methanol oxidation. The catalytic activity for methanol oxidation was closely related to the stability between electrode and electrolyte. In order to investigate the stability of catalysts, chronoamperometry analysis was carried out in the same solution at 0.6 V.

On a Cleaning of COVID-19 Prevention Masks with Electrolytic Decomposition Water (전기분해수로 코로나방역용 마스크의 세정에 관한연구)

  • Tian, Zhixing;Bae, Myung-Jin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.591-596
    • /
    • 2022
  • Various COVID-19 quarantine guidelines and measures are being taken by country at the WHO, but the number of confirmed cases has not decreased significantly. In order to prevent the inflow and outflow of COVID-19 through individual droplets, it is mandatory to wear a mask anytime, anywhere. However, as virus bacteria entering the mask amplify, it pollutes the mask and causes a disgusting smell. In this paper, a new method of preventing the spread of COVID-19 was proposed by sterilizing the mask with a dental gait spray introduced into the mask that has been used for a long time. Dental gargle water is usually produced by electrolysis of tap water, and the unstable ion water (HOCl) dissolved in water penetrates the cell barrier of various viruses and fails to act in its nucleus, causing water to self-purify. As a result of the experiment, when the mask used for a long time was washed with gargle water spray, the washed mask was dried after 10 minutes, and the smell of virus droplets or saliva almost disappeared. In particular, as a result of MOS testing the fit of the subjects who participated in the mask cleaning, it was excellent at 4.4 on average. Therefore, the mask was disposable, but if the spray was washed in the proposed method more than twice a day, the mask could be used in a comfortable state for more than a week.

Frequency Stability Enhancement of Power System using BESS (BESS를 활용한 전력계통 주파수 안정도 향상)

  • Yoo, Seong-Soo;Kwak, Eun-Sup;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.595-606
    • /
    • 2022
  • Korea has the characteristics of traditional power system such as large-scale power generation and large-scale power transmission systems, including 20 GW large-scale power generation complexes in several regions with unit generator capacity exceeding 1.4 GW, 2-3 ultra-high-voltage transmission lines that transport power from large-scale power generation complexes, and 6 ultra-high-voltage transmission lines that transport power from non-metropolitan areas to the metropolitan area. Due to the characteristics of the power system, the penetration level for renewable energy is low, but due to frequency stability issue, some generators are reducing the output of generators. In the future, the issue of maintaining the stability of the power system is expected to emerge as the most important issue in accordance with the policy of expanding renewable energy. When non-inertial inverter-based renewable energy, such as solar and wind power, surges rapidly, the means to improve the power system stability in an independent system is to install a natural inertial resource synchronous condenser (SC) and a virtual inertial resource BESS in the system. In this study, we analyzed the effect of renewable energy on power system stability and the BESS effect to maintain the minimum frequency through a power system simulation. It was confirmed that the BESS effect according to the power generation constraint capacity reached a maximum of 122.81 %.

Development and application of non-invasive drug delivery systems utilizing pulse power, and its application to mouse models (펄스파워를 적용한 비침습 약물 전달기 개발 및 마우스 모델로의 적용)

  • Hwi-Chan Ham;Kyu-Sik Kim;Ji-Hwan Lee;Hyung-Jin Choi;Do-Nyun Kim;Jai-Ick Yoh
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2024
  • Some drugs can offer far better medical effectiveness as it is injected through the intradermal layer of the skin, known as a needle-free injection. However, conventional needle-free devices might deliver a relatively large amount of drug in a just single spot of skin, splitting open the tissue layer structure, which might cause bruising and bleeding. By injecting the small volume with a fast repetition rate in a large surface area of skin, the patient may get much fewer injuries and pain. To achieve that specification, the driving force must be instantaneous and short-pulsed. Such a form of an injection device has been developed but the efficacy of those devices has been rarely examined. Therefore, this study developed the laser-induced microjet device that ejects microjet whose speed is ~310 m/s, during the 400~800 ㎲ of pulse time. The device can eject ~1 µL of the drug at the rate at which each shot repeated 10 shots per second. Using this specification, we evaluated the efficacy of drug injection onto mouse models. After injecting the insulin solution into the mouse model, the blood insulin level is detected, resulting in 20 % of blood insulin level with the ordinary needle syringe injection method.

Non-Fickian Diffusion of Organic Solvents in Fluoropolymeys (불소고분자내 유기용매의 비-픽 확산)

  • 이상화
    • Polymer(Korea)
    • /
    • v.28 no.1
    • /
    • pp.24-34
    • /
    • 2004
  • Transient sorption experiments were conducted among several combinations of fluoropolymers and various organic solvents. Fully fluorinated polymer tended to exhibit ideal sorption behavior, while partially fluorinated polymers showed anomalous sorption behaviors with a drastic acceleration at the final stage of uptake. Minimization of least-squares of the measured and predicted fractional uptake, which indicated the increasing degree of deviation from Fickian diffusion, gave values of 3.0${\times}$10$\^$-4/, 1.75${\times}$10$\^$-3/, 8.68${\times}$10/sup-3/, 1.75${\times}$10$\^$-2/, respectively, for perfluoroalkoxy copolymer, poly(ethylene-co-tetrafluoroethylene), poly(vinylidene fluoride), poly(ethylene-co-chlorotrifluoroethylene). From stress-strain tests, it was confirmed that non-Fickian diffusion is closely related to the significant variation of mechanical properties (such as modulus and tensile strength) of swollen polymer. Anomalous sorption behavior stemmed from non-Fickian diffusion caused by nonlinear disruption of polar inter-segmental bonds due to solvent-induced plasticization. Thus, it is imperative to investigate the diffusion behavior of swelling solvents in partially fluorinated polymers, especially for the application to barrier materials or perm-selective membranes.

Analyzing the Change of Surface Water and Groundwater Systems Caused by Tunnel Construction in Northern Ulsan City (울산시 북구 지역 터널 굴착에 의한 지표수계 및 지하수계 변화 분석)

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Lee, Chung-Mo;Lim, Woo-Ri;Yun, Sul-Min;Park, Heung-Jai
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.81-99
    • /
    • 2018
  • Excessive groundwater discharge by tunneling and tunnel operation can lead to groundwater exhaustion and ground subsidence. Therefore, it is very important to evaluate environmental impact and to establish mitigation measures of the impact related to tunnel excavation based on hydrogeological and modeling approaches. This study examined the depletion of surface reservoirs and valley water due to tunnel excavation through field survey, water quality analysis, tracer test, and groundwater modeling. As a result of field water quality test, the concentration of chemical constituents in groundwater discharge into the tunnel is slightly higher than that of valley water. By the result of laboratory water analysis, both valley water and the groundwater belong to $Ca^{2+}+HCO_3{^-}$ type. Tracer test that was conducted between the valley at the injection point and the tunnel, indicates valley water infiltration into the ground and flowing out to the tunnel, with maximum electrical conductance changes of $70{\mu}S/cm$ in the first test and of $40{\mu}S/cm$ in the second test. By groundwater modeling, the groundwater discharge rate into the tunnel during tunnel construction is estimated as $4,942m^3/day$ and groundwater level recovers in 3 years from the tunnel completion. As a result of particle tracking modeling, the nearest particle reaches the tunnel after 6 hours and the farthest particle reaches the tunnel after 9 hours, similarly to the case of the field trace test.

Preparation and Characterization of PVA/PSSA-MA Electrolyte Membranes Containing Silica Compounds and Surface Fluorination for Fuel Cell Applications (연료전지 응용을 위한 실리카 성분을 함유하며 표면불소화된 PVA/PSSA-MA 막의 제조 및 특성 연구)

  • Kim, Dae-Hoon;Lee, Bo-Sung;Rhim, Ji-Won
    • Polymer(Korea)
    • /
    • v.34 no.6
    • /
    • pp.540-546
    • /
    • 2010
  • In this manuscript, in order to reduce methanol permeability and, at the same time, to increase proton conductivity THS-PSA containing silica compound, responsible for methanol permeability reduction, and sulfonic acid, responsible for proton conductivity enhancement, was applied onto PVA/PSSA-MA membranes. And in order to improve durability, the resulting membranes, PVA/PSSAMA/THS-PSA, were exposed to 500ppm F2 gas at varying reaction times. The surface-fluorinated membranes were characterized through the measurement of contact angles, thermo-gravimetric analysis, and X-ray photoelectron spectroscopy to observe the physico-chemical changes. For the evaluation of the electro-chemical changes in the resulting membranes, its water contents, ion exchange capacity, proton conductivity, and methanol permeability were measured and then compared with the commercial membrane, Nafion 115. Finally, the membran electrode assembly(MEA) was prepared and the cell voltage against the current density was measured. As fluorination time increased, the contents of F2 increased up to maximum 4.3% and to depth of 50 nm. At 60 min of fluorination, the proton conductivity was 0.036 S/cm, larger than Nafion 115 at 0.024 S/cm, and the methanol permeability was $9.26E-08cm^2/s$, less than Nafion 115 at $1.17E-06cm^2/s$.

A development of new dielectric tracer test method for groundwater logging: laboratory soil column test (지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발)

  • Kim Man-Il;Kim Hyoung-Soo;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.301-311
    • /
    • 2004
  • This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration $3\%$ which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water $3\%$ concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.

A Study on the Hydraulic Properties of Aquifers in Bucheon Area (부천지역의 지하수 대수층의 수리적 특성에 관한 연구)

  • Kim, So-Hee;Lee, Yoon-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.626-633
    • /
    • 2006
  • Bucheon city has been rapidly urbanized and steadily enlarged. Also, the city depends on groundwater as an alternative water resource. The objective of this study is to characterize the hydrogeology in this city including the recharge of groundwater and hydraulic property of an aquifer in order to investigate the chemical characteristics and contamination of groundwater in the Bucheon area. Eleven groundwater wells in the Bucheon area were selected for applying certain hydraulic tests, such as pumping and recovery tests. Theis method and Theis recovery method were used to obtain hydraulic parameters, such as hydraulic conductivity, transmissivity by applying recovery tests. The playground of school and uncovered areas layed a major function of recharging areas. The groundwater well in these areas showed high recharge, transmissivity, and hydraulic conductivity. In a downtown area, groundwaier wells showed low pumping capacity and hydraulic parameters. Groundwater samples were collected from 48 different locations in the Bucheon area and that showed very various chemical composition in groundwater Their electrical conductivity showed various ranges from 70.4 to $1,287{\mu}S/cm$. The composition more significantly affected the groundwater due to the land use and urbanization than that of the aquifer rock type.