The Effects of Post-Treatments for Wet Spun PVDF on the Piezoelectric Property (습식방사 된 PVDF 섬유의 후 처리를 통한 결정구조의 변화)

  • Yu, Seung Mi;Oh, Hyun Ju;Hwang, Sang-Kyun;Chung, Yong Sik;Hwang, Hui Yun;Kim, Seong Su
    • Composites Research
    • /
    • v.26 no.2
    • /
    • pp.123-128
    • /
    • 2013
  • The PVDF (polyvinylidene fluoride) fibers were prepared using the wet spinning processing. To improve ${\beta}$-phase crystalline which closely related piezoelectric property PVDF wet spun fibers conducted post treatment. Post treatment is consisted of heat stretching and annealing process. The heat stretching and annealing conditions were controlled by changing temperature between glass transition temperature and melting temperature. From these experimental data, the resulting crystal structure of the ${\beta}$-phase crystalline was confirmed by FT-IR and XRD experiments. From these analysis results, optimum stretching and annealing conditions of the wet spun PVDF fibers were founded to increase high ${\beta}$-phase crystalline. Furthermore results showed that thermal processing had a direct effect on modifying the crystalline microstructure and also confirmed that heat stretching and annealing could increase the degree of crystallinity and ${\beta}$-phase crystalline. Finally, piezoelectric constant ($d_{11}$) of the post heat treated PVDF fibers reinforced composite were measured to investigate the feasibility for the sensing materials.

Sorptive Removal of Radionuclides (Cobalt, Strontium and Cesium) using AMP/IO-PAN Composites (AMP/IO-PAN 복합체를 이용한 방사성 핵종(코발트, 스트론튬, 세슘)의 흡착 제거)

  • Park, Younjin;Kim, Chorong;Shin, Won Sik;Choi, Sang-June
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.4
    • /
    • pp.259-269
    • /
    • 2013
  • Applicability of ammonium molybdophosphate/iron oxides-polyacrylonitrile (AMP/IO-PAN) composites on the removal of radionuclides in the radioactive wastewater generated from nuclear power plants was investigated. The composites were characterized using the following analytical techniques: X-ray diffraction (XRD), Fourior transform-infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), particle size analyzer (PSA), nitrogen adsorption-desorption and magnetic property measurement system (MPMS). 10wt% of AMP/IO-PAN composite has a saturation magnetization of 2.038 emu/g. Single-solute sorptions of Co, Sr and Cs onto 10wt% of AMP/IO-PAN composite were investigated. The maximum sorption capacities ($Q^0$) predicted by the Langmuir model on 10wt% of AMP/IO-PAN composite were 0.097, 0.086 and 0.66 mmol/g for Co, Sr and Cs, respectively. The maximum sorption capacities ($Q^0$) of Cs predicted by Langmuir model on 0, 10, 20 and 30wt% of AMP/IO-PAN composites were 0.702, 0.655, 0.602 and 0.559 mmol/g, respectively. The maximum sorption capacities ($Q^0$) of Cs decreased with increasing the iron oxide content in the AMP/IO-PAN composites.

Specification and Limitation of ToF Cameras (ToF 카메라의 특성과 그 한계)

  • Hong, Su-Min;Ho, Yo-Sung
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2016.06a
    • /
    • pp.12-15
    • /
    • 2016
  • 요즘 들어, 3차원 콘텐츠의 수요는 지속적으로 증가하고 있다. 3차원 콘텐츠의 품질은 해당 장면의 깊이 정보에 큰 영향을 받기 때문에 정확한 깊이 정보를 얻는 방법이 매우 중요하다. 깊이 정보를 얻는 방법은 크게 수동형 방식과 능동형 방식으로 나뉘는데, 수동형 방식은 계산 과정이 복잡하고 깊이맵의 품질이 보장되지 않는 단점을 갖기 때문에 능동형 방식이 많이 사용되고 있다. 능동형 방식은 깊이 카메라를 이용하여 직접적인 깊이 정보를 얻는 방식으로, 대게 ToF(Time-of-flight) 기술이 사용된다. 이 논문에서는 ToF 깊이 카메라로 촬영된 실제 깊이맵의 특성을 분석하기 위해 여러 가지 촬영 환경과 객체에 대해서 SR4000 깊이 카메라와 키넥트 v2 센서를 이용하여 깊이맵 품질을 비교했다. 실험 결과, 적외선이 제대로 반사되기 어려운 방사성 물질이나 표면, 경계 영역, 어두운 영역, 머리 영역 등에서 정확한 깊이 정보를 얻기 어려웠으며, 실외 환경에서 정확한 깊이 정보가 획득되지 않는 것을 확인할 수 있었다.

  • PDF

Effects of MnO_2$ Additives on the Characteristics of Infrared Radiator of Cordierite System (Cordierite계 적외선 방사체의 제특성에 미치는 MnO_2$의 영향)

  • 최두선;신용덕
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.9
    • /
    • pp.975-980
    • /
    • 1994
  • The thermal properties of cordierite (2MgO.2Al2O3.5SiO2)+30 wt% clay+ Xwt% MnO2 of infrared radiator have been investigated as a function of MnO2 additives (X=0,0.1,0.25,0.5,1.0,1.5,2.0,2.5). The thermal expansion coefficient was decreased with increasing amounts of MnO2 additives. Otherwise, the spectral emissivity was increased in the below 4.5 ${\mu}{\textrm}{m}$ wavelength. Also, the infrared radiator of cordierite system which spectral emissivity was approximately 1.0 can be attainable at from 4.5 ${\mu}{\textrm}{m}$ to 8 ${\mu}{\textrm}{m}$ wavelength. The spectral emissivity was decreased from 8 ${\mu}{\textrm}{m}$ to 14 ${\mu}{\textrm}{m}$ above X=2.5.

  • PDF

Method for Measuring Mechanical Behaviors of Thin Films at High Temperature (고온에서 박막의 기계적 거동 측정 방법)

  • Lim, Sang-Chai;Joo, Jae-Hwang;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.102-108
    • /
    • 2003
  • Recently, the authors have developed a new material test system fur thin film at the high temperature. It is so compact and precise with sub micron resolution that it seems to be a useful tool fur research of the oxide film growth, its mechanical behavior and failure mechanism. To this end. in this paper three methologies are described for in-situ monitoring of the displacement & strain and the temperature, the oxide thickness. These are the Laser Speckle analysis with digital image correlation technique, the two-color infra-red thermometer and the laser reflection interferometry respectively. The calibration results and some issues which should be addressed for practical application are presented.

The implementation of Lab-on-a-chip type Glucose sensor which uses PVA and design (PVA를 이용한 Lab-on-a-chip type Glucose sensor설계 및 구현)

  • Lee, S.R.;Kim, G.Y.;Lee, Y.T.;Seo, H.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.927-931
    • /
    • 2004
  • 본 논문에서는 혈당측정기 제작에 있어 PDMS(Su-8)를 이용하였다. 이는 일종의 고분자로서 기계적 특성이 우수하고 제작이 간단하며, 가격이 저렴하고 다른 물질과의 접합이 용이하다. 혈액의 펌핑과 믹싱을 할 수 있도록 새로운 구조체를 설계하였으며 제안된 모델의 핵심 부분인 측정전극의 제작에 필요한 기초적인 실험을 수행하였다. 측정전극의 성능향상과 제작편의성, 저가격화를 위해 효소고정화방법으로 Electrospinning (전기방사)으로 제조된 PVA nanofiber web을 이용하였으며, 이는 중합도 Pn=1700, 비누화도 98%인 공업용으로 상용화된 값싼 제품이다. 따라서 이를 이용하면 측정용 전극의 효소고정화에 있어 저가격화를 이룰 수 있을 것으로 기대된다 고정화된 전극분석을 위해 SEM(주사전자현미경)과 NMR(핵자기공명분광계), FT-IR(적외선분광분석)장비를 사용하였다. 그리고 기존의 효소고정화법(전기중합법)과의 응답특성을 비교분석하였다.

  • PDF

Temperature Distribution Monitoring of Transformer Using IRR-Camera (적외선방사카메라를 이용한 변압기 온도분포 모니터링)

  • 이우선;정찬문;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

의용생체공학(4)

  • Hong, Seung-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.2 no.3
    • /
    • pp.20-27
    • /
    • 1985
  • Opto-electronics의 의학에의 응용: 전자공학과 광학의 결합산물인 광전자공학긔 의학응용은 진단,치료에 새로운 경지를 열어주게 되었다. 계측진단은 검체에 적용하는 것과 생체에 적용하는 것으로 분류되어진다. 검체에 적용하는 것은 주로 INVITRO 계측으로 생화학분석, 전기영동, 자동혈구계수등이다. 생체에 적용하는 INVIVO 계측은 관찰, 계측용의 내구경과 비관혈계측으로 분광분석, 산소포화도등의 광의 투과율계측, 적외.마이크로파 .thermography와 같은 방사계측, 발색량계측 등이 이에 속한다. 또한 광전자공학을 응용하여 병원애 전송네트워크구성, 광통신등도 최근의 활용과제중의 하나다. 특히 광전자공학의 응용중에서 가장 관심의 대상이 되는것은 치료에의 응용이다. 그러므로 여기서는 이들 응용중에서 가장 유용성이 있는 적외선 thermography와 Laser의 응용에 대해 간단히 기술하기로 한다.

  • PDF

A Study on Heat Transfer Characteristics of Impinging Jet Using Infared Thermal Image Processing System (적외선열화상처리장치를 이용한 충돌제트의 전열특성에 관한 연구)

  • Kim, D.K.;Bae, S.T.;Kim, S.P.;Lee, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.711-716
    • /
    • 2001
  • This paper presents an information about the heat transfer characteristics of impinging jet in eletronic equipment with infrared image processing unit. There have been many experimental investigations and theoretical studies on impinging jet because of application in a wide variety of industrial process including electronic equipment. In this study, we used infrared image processing unit to visualize heat transfer characteristics of impinging jet in electronic equipment. Infrared image processing unit is one of non-contact temperature measuring methods and it is possible to minimize flow resistance and this measurement is comparatively accurate. The main parameters are nozzle exit angle $(30^{\circ},\;45^{\circ},\;60^{\circ},\;75^{\circ},\;90^{\circ})$ and distance between nozzle and heat source is fixed 6d("d" is diameter of circular nozzle(10 mm). Reynolds number is 4500.

  • PDF

Hybrid laser welding of Polymers (하이브리드방식의 레이저를 이용한 폴리머융착)

  • Han, Sang-Bae;Hofmann, A.
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2006.06a
    • /
    • pp.47-51
    • /
    • 2006
  • 레이저를 이용한 폴리머의 융착기술은, 자동차산업에서의 다양한 적용분야에 힘입어 새로운 접합기술로 각광을 받고 있다. 현재까지는, 대부분 작고 간단한 형상의 제품을 융착하는 분야에 많이 적용되어 왔으며, 튼 사이즈의 제품을 대량으로 생산하는 공정에서는 레이저융착이 가지는 다양한 장점에도 불구하고, 프로세스의 안정성, 사출후의 제품변형에 따른 갭의 관리, 작업속도등에 대한 이유로 본격적인 적용을 기피하고 있는 실정이다. 이러한 배경에 의하여 개발된 하이브리드방식(레이저빔+할로겐램프)의 폴리머융착 시스템은, 다이오드레이저에서 출력되는 $800{\sim}980nm$의 레이저파장과 할로겐 램프에서 방사되는 적외선영역의 파장을 동시에 사용함으로써 프로세스의 안장성과 융착효율을 향상시켰다.

  • PDF