• Title/Summary/Keyword: 저항률

Search Result 901, Processing Time 0.035 seconds

Optimization of the Backfill Materials for Underground Power Cables considering Thermal Resistivity Characteristics (I) (열저항 특성을 고려한 지중송전관로 되메움재의 최적화(I))

  • Kim, You-Seong;Cho, Dae-Seong;Park, Young-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.113-121
    • /
    • 2011
  • River sand has generally used for the backfill material of underground power cables. The thermal resistivity of it has $150^{\circ}C$-cm/Watt in wet condition and more than double in dry condition. The final goal of this study is to find the backfill material which has a small change in thermal resistivity with various water contents, for example thermal resistivity is $50^{\circ}C$-cm/Watt and $100^{\circ}C$-cm/Watt in wet and dry conditions respectively. In this study it is presented that the comparison of thermal resistivity using stone powder, crush rock, weathered granite soil and Jumunjin sand as well as river sand in the needle method regarding water content, dry unit weight and particle size distribution. As a result, the thermal resistivity of a material is minimized when they have maximum dry unit weight at optimum moisture content and maximum density by appropriately mixing materials for particle size distribution. Therefore thermal resistivity characteristics should be considered two factors: one is the difference between natural dry condition and dry state after optimum moisture content, and the other is the difference between unit weight of raw material and maximum dry density.

Electrical Resistivity at Room Temperature and Relation between Physical Properties of Core Samples from Ulleung Island (울릉도 시추 코어의 상온 전기비저항과 물성 간의 상관성)

  • Lee, Tae Jong;Lee, Sang Kyu;Yun, Kwan-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.4
    • /
    • pp.171-180
    • /
    • 2015
  • Electrical resistivity of 23 core samples from Ulleung Island at dry or saturated condition has been measured along with dry density and effective porosity, and the relations between the properties has also been discussed. Upper and lower bounds of electrical resistivity at room temperature can be provided by the dry- and saturated-resistivity, respectively. Injecting nitrogen gas to the pore space at the very end of drying process can prevent humid air from getting into the pore space, so that measurement of dry-resistivity can be less affected by humidity in the air. Dry density and porosity have very close correlation; the ratio between increase of porosity and the decrease of density showed distinct relation to the rock types, such that basaltic rocks showed higher ratio while trachytic rocks showed lower. Saturated resistivity showed close correlation to density and effective porosity of the rock sample, while dry resistivity didn't.

Determining Kernel Function of Apparent Earth Resistivity Using Linearization (선형화를 이용한 대지저항률의 커널함수 결정)

  • Kang, Min-Jae;Boo, Chang-Jin;Lee, Jung-Hoon;Kim, Ho-Chan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.454-459
    • /
    • 2012
  • A kernel function of apparent earth resistivity can be estimated using the apparent earth resistivity measured with Wenner's 4 point method. It becomes to solve a nonlinear system to estimate the kernel function of apparent earth resistivity. However it is not simple to get solution of nonlinear system with many unknown variables. This paper suggests the method of estimating kernel function by linearizing this nonlinear system. Finally, various examples of earth structure have been simulated to evaluate the proposed method in this paper.

Material Properties of Concrete Produced with Limestone Blended Cement (석회석 혼합 시멘트로 제조된 콘크리트의 기초 물성)

  • Bang, Jin-Wook;Kwon, Seung-Jun;Shin, Kyung-Joon;Chung, Woo-Jung;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.125-132
    • /
    • 2015
  • This paper presents an experimental investigation in order to evaluate fresh and hardened properties of LP (Limestone Powder) blended cement concrete. The cement contents of the mixtures are replaced by LP in the range of 10%, 15%, 25%, and 35%, while a control mixture is prepared with only OPC (Ordinary Portland Cement). The fresh concrete properties like slump and air content are similar to those of control mixture up to 35% of replacement ratio of LP, however a delay in setting time is evaluated. The hardened properties including compressive strength, flexural strength, and rapid freezing and thawing resistance shows similar results of control mixture up to 15% of replacement. Relatively lower strength development is evaluated over 25% replacement of LP. For accelerated carbonation test, resistance to carbonation rapidly decreases with increasing LP replacement ratio due to the limited amount of $Ca(OH)_2$. From the study, LP replacement under 15% can be adopted considering reduction of strength and resistance to carbonation.

Investigation of Coring Grounding Construction by Equivalent Radius Concept (등가반경개념에 의한 코어링 접지공사의 고찰)

  • 김세호;김일환;양문길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.103-110
    • /
    • 2003
  • The grounding system is necessary to provide means to dissipate electric currents into the earth without exceeding any operating and equipment limits. The ground is composed of various soils and the resistivity of the soil depends on many parameters. It depends on the type of soil and varies with distance as well as with depth. Especially, soil resistivity of volcanic area such as Jeju is ve교 high and it is difficult to acquire necessary grounding resistivity. This paper introduces the efficient grounding construction using coring technique for proper grounding resistance in high resistivity area. Because it is difficult to measure the accurate resistivity of soils, their resistivities are estimated using measured value of ground resistance and equivalent radius method. Estimated resistivities are used for grounding resistance in scheduled construction region.

Effects of Matrix Strength, Fiber Type, and Fiber Content on the Electrical Resistivity of Steel-Fiber-Reinforced Cement Composites During Fiber Pullout (매트릭스 강도, 섬유 형식 및 보강량에 강섬유 보강 시멘트 복합재료의 인발시 전기저항에 미치는 영향)

  • Le, Huy Viet;Kim, Dong Joo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.675-689
    • /
    • 2019
  • Development of smart construction materials with both self-strain and self-damage sensing capacities is still difficult because of little information about the self-damage sensing source. Herein, we investigate the effects of the matrix strength, fiber geometry, and fiber content on the electrical resistivity of steel-fiber-reinforced cement composites by multi-fiber pullout testing combined with electrical resistivity measurements. The results reveal that the electrical resistivity of steel-fiber-reinforced cement composites clearly decreased during fiber-matrix debonding. A higher fiber-matrix interfacial bonding generally leads to a higher reduction in the electrical resistivity of the composite during fiber debonding due to the change in high electrical resistivity phase at the fiber-matrix interface. Higher matrix strengths, brass-coated steel fibers, and deformed steel fibers generally produced higher interfacial bond strengths and, consequently, a greater reduction in electrical resistivity during fiber debonding.

Stretchable Deformation-Resistance Characteristics of Metal Thin Films for Stretchable Interconnect Applications I. Effects of a Parylene F Intermediate Layer and PDMS Substrate Swelling (신축 전자패키지 배선용 금속박막의 신축변형-저항 특성 I. Parylene F 중간층 및 PDMS 기판의 Swelling에 의한 영향)

  • Park, Donghyun;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.3
    • /
    • pp.27-34
    • /
    • 2017
  • We investigated the feasibility of parylene F usage as an intermediate layer between a polydimethylsiloxane (PDMS) substrate and an Au thin-film interconnect as well as the swelling effect of PDMS substrate on the stretchable deformability of an Au thin film. The 150-nm-thick Au film, which was sputtered on a PDMS substrate without a parylene F layer, exhibited an initial resistance of $11.7{\Omega}$ and an overflow of its resistance at a tensile strain of 12.5%. On the other hand, the Au film, which was formed with a 150-nm-thick parylene F layer, revealed an much improved resistance characteristics: $1.21{\Omega}$ as its initial resistance and $246{\Omega}$ at its 30% elongation state. With swelling of PDMS substrate, the resistance of an Au film substantially decreased to $14.4{\Omega}$ at 30% tensile strain.

Effect of Gas Diffusion Layer Compression and Inlet Relative Humidity on PEMFC Performance (기체확산층 압축률과 상대습도가 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.68-74
    • /
    • 2021
  • Gas diffusion layer (GDL) compression is important parameter of polymer electrolyte membrane fuel cell (PEMFC) performance to have an effect on contact resistance, reactants transfer to electrode, water content in membrane and electrode assembly (MEA). In this study, the effect of GDL compression on fuel cell performance was investigated for commercial products, JNT20-A3. Polarization curve and electrochemical impedance spectroscopy was performed at different relative humidity and compression ratio using electrode area of 25 ㎠ unit cell. The contact resistance was reduced to 8, 30 mΩ·㎠ and membrane hydration was increased as GDL compression increase from 18.6% to 38.1% at relative humidity of 100 and 25%, respectively. It was identified through ohmic resistance change at relative humidity conditions that as GDL compression increased, water back-diffusion from cathode and electrolyte membrane hydration was increased because GDL porosity was decreased.

Design of Grounding System for Rock Area by Ground Resistivity measurement (암반지형에서의 대지저항률 측정을 통한 접지설계)

  • Lee, Jeong-Hun;An, Ho Sung;Maeng, JongHo;Mun, Seong Duk;Ahn, Heesung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.394-395
    • /
    • 2015
  • 접지시스템은 전력계통에서 사고가 발생하거나 접지가 시공된 시설물에 낙뢰가 침입하는 경우와 같이 고장 전류나 써지가 발생하였을 때 대지로 신속하게 방전시켜 전력기기의 파손 및 고장을 방지하고 대지 전위 상승을 억제하여 인체에 대한 안전성을 확보를 해야한다. 본 논문에서는 대지저항률이 높은 암반지형에서 접지시스템을 설계하기 위해서 대지저항률을 측정하여 토양모델을 모의하였으며, 접지망 설계를 통해 대지 전위 상승을 모의하여 인체 안전 측면을 검토하고자 한다.

  • PDF