• Title/Summary/Keyword: 저시력 재활

Search Result 11, Processing Time 0.024 seconds

A Study on the Factors Affecting the use of Optical Aids by the aged with Low Vision (저시력 노인의 시력보조기구 사용에 영향을 미치는 요인에 관한 연구)

  • Yeum, D.M.;Sim, M.Y.;Jung, S.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.3
    • /
    • pp.213-219
    • /
    • 2014
  • This study applied the data of 384 senior citizens over 65 years old having difficulties in everyday life, among the ageing research panel of Korea Labor Institute in 2000, due to their visual impairment in the final analysis to investigate factors affecting the use of vision aids by the aged with visual impairment. The analysis was based on the service usage Andersen-Newman model and the factors were classified into preceding factors, potential factors and desire factors. To examine the effects of each factors on the use of vision aids by the aged with visual impairment, logistic regression analysis was carried out. In the analysis results, the level of vision aids usage was shown to increase significantly with unemployed status and higher education level in the preceding factors, lower subjective stratum consciousness in the potential factors, and higher cognitive function in the desire factors. The limitation and implication of this study were suggested on the basis of the results.

  • PDF

A Study on Factors Affecting Social Integration of Visually Impaired People in Korea (시각장애인의 지역사회통합 실태와 관련 요인)

  • Lee, Ik-Seop;Park, Soo-Kyeong;Kwak, Jee-Young
    • Korean Journal of Social Welfare
    • /
    • v.54
    • /
    • pp.149-176
    • /
    • 2003
  • The purpose of this study is to examine the degree of community integration of visually impaired people who have the limitation of mobility in comparison with another disabled and to find factors affecting community integration. The data were obtained through telephone interview with visually impaired people. The final sample was consisted of 1,004 respondents. The data were analyzed using statistical techniques such as crosstabulation, t-test, and hierarchical regression. In this study, the factors affecting community integration was divided into four dimensions : the attribution to disability, physical functioning, psychology and social support system. The major findings of this study were as follows: First, the factors affecting community integration of visually impaired people were age, education, economic status, social support, information support and participation of rehabilitation service. Second, the factors affecting community integration of the low vision and the blind are the limitation of daily activities and social support. But the factors affecting community integration of the blind are participation of education for braille and that of the low vision are information support and participation of rehabilitation service. Finally, the person losing eyesight since school age were the more limitation of daily activities than the person losing eyesight in babyhood. The factors affect community integration of the former are social support, information support, participation of education for braille, and rehabilitation service. The current findings suggest that intervention and policy aimed at improving social support system and formal services such as education, rehabilitation services should be considered by rehabilitation professionals and policy makers.

  • PDF

Reliability and Validity of the Korean Version of Melbourne Low-Vision ADL Index (한국판 맬버른 저시력 일상생활지수(Melbourne Low-vision ADL Index: MLVAI)의 신뢰도 및 타당도)

  • Yoo, Yeon Hwan;Park, Ji-Hyuk;Jung, Min-Ye;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.7 no.2
    • /
    • pp.51-61
    • /
    • 2018
  • Objective: The purpose of this study was performed to modify the performance-based assessment tool, Melbourne Low-Vision ADL Index (MLVAI) had been developed in Australia to suit the Korea culture to verify the reliability and validity. Methods: The subjects were only over the age of 20 living in communities, 26 with low-vision and 42 normal persons. The Korean MLVAI was completed through the expert translation verification and validation of the configuration tool. The validity of the Korean MLVAI was established through the content, discriminant, and convergent validity. Also, the reliability was analyzed through internal consistency reliability for the items, test-retest, and interrater reliability. Results: The Content Validity Index(CVI) was more than .78. There was a statically significant low in low-vision. Also, there was a statically significant low in low-vision. The convergent validity was determined the correlation coefficient of .751 analyzing LVQOL and Korean MLVAI total score, had a significant correlation(p<.05). Cronbach's ${\alpha}$ coefficient indicated an internal consistency of .983(p<.05). Test-retest reliability had a high, significant correlation of .976 and interrater reliability had a high, an intraclass correlation coefficient of .91(p<.05). Conclusion: The results of this study mean that the Korean MLVAI which was modified to fit the Korean is the ADL assessment tool with both validity and reliability. Based on this study, the Korean MLVAI can be used as a useful ADL assessment for OT interventions in low vision.

Usability Testing of OpenCourseWare(OCW) by College Students with Visual and Hearing Impairments - Focused on the Accessibility of KOCW - (시각 및 청각장애 대학생의 오픈코스웨어(OCW) 사용성 평가 - KOCW의 접근성을 중심으로 -)

  • Son, Ji-Young;Yeom, Myung-Sook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.2
    • /
    • pp.127-132
    • /
    • 2016
  • The purpose of the study is to identify the accessibility of OpenCouresWare(OCW) from the perspective of college students with visual and hearing impairments. Six students with visual impairments(3 blind and 3 low vision) and four students with hearing impairments(2 deaf, 2 hard of hearing) implemented usability testing. Two modules in KOCW were selected for testing. Students implemented usability testing and then each individual case was analyzed through quantitative and qualitative methods. As results, the degree of usability and accessibility in two modules indicated low level. Implications and recommendations for designing OCW module based on the results were suggested.

Accessibility Analysis of Mobile Applications for Open Platforms (개방 플랫폼용 모바일 애플리케이션 접근성 분석)

  • Moon, Hyun Ju;Min, Hong Ki;Kim, Sukil
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.2
    • /
    • pp.187-198
    • /
    • 2017
  • In this study, we analyzed the accessibility of open platform Android mobile banking applications, based on Korean mobile application accessibility KS standard, Section 508 technical standard of Rehabilitation Act, and European BBC guidelines. Experimental result showed that there are no mobile banking applications of 8 commercial banks in Korea that satisfy all guidelines of three standards. Typical violations included missing alternative text, keyboard focus violations, control size and spacing non-compliance, and low contrast ratio. These violations are fatal in that they make the accessibility of the blind, the disabled and the low vision and the elderly impossible. The reason that mobile banking applications do not comply with accessibility is that mobile application developers and providers have low awareness of accessibility and do not know how to implement accessibility properly. Comparing Korea mobile application accessibility guidelines with the revised standard of the Section 508 of Rehabilitation Act and the BBC standard, many guidelines are missing. Also, evaluation criteria are ambiguous and abstract, making it difficult for developers to refer specifically. Therefore, improving mobile application accessibility requires developer and government efforts and complementation of standards.

Study on Developing the Equipment of the Time Division System for Rehabilitation in People with Homonymous Hemianopia (동측성 반맹시 환자의 재활치료용 시분할 장치 개발에 관한 연구)

  • Seo, Jae-Myoung;Park, Gune-Ho;Heo, Min-Young;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.407-412
    • /
    • 2014
  • Purpose: It is investigated whether the time division system can extend the field without diplopia for people with homonymous hemianopia. Methods: The time division system was manufactured by a modified mini fan and a black cardboard. In order to verify the effectiveness of the equipment, subjects with and without the equipment took part in the experiment to bisect the space and to recognize letters. Results: Subjects with and without the equipment showed +8.91 and +18.14 degrees in the experiment to bisect the space. In the experiment reading the letters and numbers with the equipment, there were 9 percentage point increase in $4{\times}4$ charts and 15 percentage point increase in $6{\times}6$ charts. It turned out that there was a remarkable improvement for the worst group for reading the charts. Conclusions: The time division system is effective in the mobility and orientation for people with homonymous hemianopia.

Development of Tactile Display for the Blind in Japan (일본의 시각장애인을 위한 촉각디스플레이 개발)

  • Han, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.63-70
    • /
    • 2010
  • Research and development of Assistive Technology (AT) for blind people is primarily focused on assisting mobility and improving access to information. Some particularly useful devices for aiding access to information and communication are DAISY players used with talking books, screen readers for reading screens, video magnifiers to aid low vision, Braille displays, and Braille PDAs. These essential devices have been successfully commercialized and have assisted many visually impaired people. Assistive technology devices for visually impaired people are called sensory substitution devices, because these devices substitute tactile or auditory functions for visual functions. The tactile interfaces of sensory substitution devices such as Braille displays and Braille PDAs have a bimorph type of piezoelectric actuator that forms a Braille (pin) of the Braille cells by moving up and down. KGS Corporation of Japan has more than 80% share of the worldwide market for these Braille cell actuators. Commercializing it for the first time in the world. This paper reviews the various endeavors in Japan in the research and development of tactile displays, such as Braille displays and Braille PDAs. Furthermore, it discusses sensory substitution devices that use tactile displays, focusing especially on the rotating Braille display we have developed.

Effects of the Eccentric Viewing Training Software Based on Korean for Reading Speed: A Case Study (한글기반 중심외보기 훈련 프로그램이 읽기속도에 미치는 효과: 사례연구)

  • Hong, Seung-Pyo
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.441-449
    • /
    • 2018
  • The aims of this study were to consist of the eccentric viewing training software based on Korean and to examine the effects on reading speed. The program was used the Korean stimuli by rapid serial visual presentation. Single-subject A-B-A' research design for 2 normally-sighted young adults was used to examine the effect. The reading speed data on short-sentence of participants showed a statistically significant result, as both data from the intervention period and post-training baseline period deviated more than 2 standard deviations from the pre-training baseline period. Through this study, we suggested that eccentric viewing training software based on Korean characters stimulation would allow clinician in Korea to improve reading skills of low vision individuals with central scotomas.

Study on Physiological Summation in Peripheral Retina for Eccentric Viewing Training (중심외주시 훈련용 주변부 망막의 생리적 가중에 관한 연구)

  • Seo, Jae-Myoung;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.489-493
    • /
    • 2013
  • Purpose: This study was to investigate peripheral vision and provide people with macular degeneration with a guideline for eccentric viewing training. Methods: 30 adult subjects with normal vision took part in this study. The lateral area of $20^{\circ}$ eccentricity from the fovea of right eye was only used to measure the physiological summation. The target was sinusoidal vertical gratings within a circular aperture. The critical points in spatial and temporal summation was found to compare each other for 0.7 cpd and 3.0 cpd, respectively. Results: Critical duration and contrast sensitivity for 0.7 cpd were 540 ms and 1.1, and 315 ms and 0.98 for 3.0 cpd respectively. The critical degrees and contrast sensitivity for 0.7 cpd were $11.3^{\circ}$ and 2.8, and $5^{\circ}$ and 2.63 for 3.0 cpd respectively. Conclusions: The critical point in peripheral vision reaches relatively faster than the one in central vision. It is recommended to train the peripheral retina under the lower spatial frequency more frequently for a short time than constantly for a long time.

Change of Contrast Sensitivity in Peripheral Vision Following Eccentric Viewing Training (중심외주시 훈련 후 주변시야에서의 대비감도 변화)

  • Seo, Jae-Myoung;Lee, Ki-Young;Lim, Yong-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.99-104
    • /
    • 2014
  • Purpose: This study was to investigate the functional improvement in peripheral vision following eccentric viewing training. Methods: 14 subjects with normal vision took a part with their right eye, peripheral retinal which is $20^{\circ}$ lateral area from the fovea was examined for contrast sensitivity(CS). Eccentric viewing training was performed for 21days with an hour image viewing and examination was repeated. Results: The critical durations for 0.7 cpd were increased 2.67(467 ms) for pre-eccentric viewing training to 2.79(616 ms) for post-eccentric viewing training (p>0.05). The critical durations for 3.0 cpd were also increased 2.53(341 ms) for pre-eccentric viewing training to 3.04(1102 ms) for post-eccentric viewing training (p>0.05). Conclusions: It is recommended to use higher spatial frequency with higher CS for eccentric viewing training and to train more frequently for a short time. Moreover, the study on Korean standardizing of the visual rehabilitation for low vision based on the etiology is sorely required.