• 제목/요약/키워드: 장스팬

검색결과 93건 처리시간 0.027초

Measuring Method Development for High Performance Concrete Structures by Wireless FBG Monitoring System (무선계측 모니터링 시스템을 이용한 고성능-고강도 콘크리트 계측기법 연구)

  • Jang, Il-Young;Yun, Ying-Wei;Ryu, Jeong-Su;Son, Chang-Ho;Park, Seung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.507-508
    • /
    • 2009
  • With the rapid increase of HPC infrastructures especially high-rise building and large-span bridge. Great concern has been focused on safety problems. In this paper wireless FBG monitoring system for HPC structures have been developed and tested to avoid the potential danger.

  • PDF

Evaluation of Serviceability to Long Span Hollow Core PC Slab (장스팬 Hollow Core PC 슬래브의 사용성 평가에 관한 연구)

  • Jeong, Hyung-Il;Kang, Ji-Hun;Jang, Dong-Un
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.955-960
    • /
    • 2000
  • This paper evaluates the serviceability of vibration that is induced by people's walking and running when the long span hollow core slab is used. The dynamic characteristics like a natural frequency and a ramping ratio are found by impact loading test on the mock-up structures. Also, the human induced loading test output is evaluated by the various serviceability criteria. As the various serviceability criteria satisfy with this result, the vibration problem of relevant slab caused by people's behavior does not matter.

  • PDF

A Case Study on Implementation Method of Non-Uniform Structures for Seoul Botanic Park (서울식물원(마곡중앙공원)의 비정형구조물 시공구현방안 검토사례 연구)

  • Song, Hwa-Jun;Park, Kyoung-Yeun;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.8-9
    • /
    • 2020
  • While non-uniform shapes are appearing as an apparent building style recently, most architects predominantly think structure and construction technology should support the designed shape of non-uniform structures determined by the architect. Within such a governance structure of architect's perception, the role of an engineer is emphasized for technical support only. Especially, in making a decision on a structural design and plan, if various and objective reviews are not conducted, the design is very likely to be left only as a drawing even if the design is appropriate for criteria and norms. With the recognition of such problems, the present study attempted to propose an equal cooperative relationship between architects and engineers in designing non-uniform structures in the future.

  • PDF

Shear Performance of Board-type Two-way Voided Slab (일체형 중공재의 중공부 내부형상에 따른 이방향 중공슬래브의 전단성능 평가)

  • Choi, Hyeon-Min;Park, Tae-Won;Paik, In-Kwan;Kim, Je-Sub;Han, Ju-Yeon
    • Journal of the Korea Concrete Institute
    • /
    • 제27권6호
    • /
    • pp.651-659
    • /
    • 2015
  • Currently, social demands for long span building structures are increasing due to architectural planning purposes and economic efficiency. As a result, lighter board-type voiding materials were suggested. With the use of board-type voiding materials, a slab is able to become light weight and convenient. This process efficiently eliminates concrete where it is not required; considerably diminishing dead weight while maintaining the flexural strength of the slab. The reduction in concrete also allows for overall cost reductions and design flexibility. Also it can be ease with fixing the voided material that is composed of one body form. Although board-type voiding materials are ideal, the top and bottom concrete plates lack integrity. Because of this, test results show horizontal cracking towards the tops and bottoms of the concrete columns, or webs, connecting the slabs. The key to correcting this problem is to increase the shear strength. In order to increase the shear strength of the structure, horizontal shear area must increase. R70(100)-D-F has the largest horizontal shear area as it also shows stronger strength. As a result, shear strength ($V_{nh}$) is dependent on the horizontal shear area (N). $V_{nh}={\alpha}{\times}0.16{\sqrt{f_{ck}}}{\frac{{\pi}D^2}{4}}{\times}N({\alpha}=1.8125)$. The web columns have a shear span to depth ratio (a/d) that is less than 2; which classifies it as a deep beam. In this case, however, the shear strength of the deep beams may be as much as 2 to 3 times greater than that predicated conventional equations developed for members of normal proportions. As a result, ${\alpha}$ is suggested as an extra coefficient in the equation for shear strength ($V_{nh}$).

Deflection Evaluation of the Constructing-load Carrying Capacity for Deep Decking Floor System Reinforced with Both Ends Cap Plates (캡 플레이트로 단부 보강한 춤이 깊은 데크의 시공중 처짐성능평가)

  • Jeon, Sang Hyun;Kyung, Jae Hwan;Kim, Young Ho;Choi, Sung Mo;Yang, Il Seung
    • Journal of Korean Society of Steel Construction
    • /
    • 제27권2호
    • /
    • pp.155-167
    • /
    • 2015
  • If of application of the deep deckting floor in long span more than 6m, the deflection caused by the construction load occurred high. Because the constructing-works and safety by this deflection, take actually supports to laborers working on the deck. However, installed supports are having difficultly such as the restricted passage, deficiency of working space, and lowering of efficiency. And toward-opening deck is seen as local buckling of web plate, flexural-torsional buckling, and gradually opening of corrugated decking. In this study, we will suggest a deep decking floor system that reinforced with both ends cap plates for toward-opneing decking change from opening to closing. The constructing deflection of a deep decking more than 6m must be satified 30mm and L/180 as proposed. Full-scale field tests loading by sand conducted a deep decking reinforced with and without cap plate. In conclusion, the specimen reinforced with cap plates have shown that to ensure the negative moment $wl^2/18$. And constructing-deflection of deep decking shown that to satisfy the evaluation value (L/180 or 30mm).

Local Buckling Behavior of Tapered Members under Cyclic Loading (반복하중을 받는 변단면부재의 국부좌굴 거동)

  • Lee, E.T.;Kim, Jong Won;Park, Ji Hoon;Shim, Ju Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • 제18권3호
    • /
    • pp.321-329
    • /
    • 2006
  • The use of tapered structural members was first proposed by Ami rikian for the economical use of materials.Generaly, tapered members are used in single-story structures with one or more bays and in cantilevered sections of ate architectural representation. If only focused on the section performance, however, the width-to-thickness ratio or t apered ratio can exced regulations. Such a case requires a study on the behavior of tapered members. To investigate the plastic and local buckling behavior of web-tapered beams, seven steel beams were the tapered ratio and the width-to-thicknes ratio. The results of maximum strength, strength deterioration, and stiffnes deterioration were compared.

Analytical Study on Strength Resistance of Steel Beams with Stiffened Ends by Reinforced Concrete -difference of behavior with fixing plate- (복합보의 내력성능에 관한 연구 -정착판의 설치에 의한 거동의 차이-)

  • Kim, Seong Eun
    • Journal of Korean Society of Steel Construction
    • /
    • 제12권6호
    • /
    • pp.681-690
    • /
    • 2000
  • Recently, a long span is often required for the spacious building. Therefore the increase of stiffness is necessary to prevent floor vibration and control deformation of the building under earthquake and wind loads. For this purpose, steel beams with stiffened ends by reinforced concrete are effective. To realize such an effective reinforcement method, the smoothening of bending and shear stress transmission at the boundaries between middle-part of the steel beam and both end-parts of the steel beam with stiffened ends by reinforced concrete is required. Therefore, the fixed plate was installed at the boundary with the view of transferring the stress smoothly. This paper evaluates the method of effective transmission of bending and shear stress through the numerical analysis that is based on advanced experimental tests.

  • PDF

The Development of Structural System of Long-span Greenhouse Using the Pre-Engineering Building System (선설계기법을 이용한 장경간 유리온실 구조시스템 개발)

  • Oh, Myoung-Ho;Kim, Yong-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • 제10권1호
    • /
    • pp.1-7
    • /
    • 2010
  • Rural facilities need to be changed to be industrialized and long span structures due to accelerating aging of the rural population. In this study, the optimized structure was developed by applying Pre-Engineered Building System using the tapered member to make that the Korea standard green house has a long span. When considering design load, reasonable values were adapted by reviewing existing design codes. As a result, applying pre-engineered building system was efficient in structural system that has span longer than 16 m. And it was concluded that the increase with the longitudinal span from 4 m to 12 m was more efficient in aspect of steel amount.

The Development of Web Database for the Construction Information of Spatial Structure (대공간구조물 건설정보의 웹 데이터베이스 개발)

  • Jang, Myung-Ho;Park, Sang-Yoon;Sur, Sam-Yeol
    • Proceeding of KASS Symposium
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.27-30
    • /
    • 2008
  • Even though the frequency of constructing spatial structure is increasing currently, the problem is that no efficient medium to provide information of goof quality on spatial structure is existed. The information is available only for some limited number of major construction companies with experiences, not for the academic world, officials. It costs us much time and money gaining the information for spatial structure without integrated media. Thus the purpose of this study is to develop an integrated web database model for spatial structure.

  • PDF

Inelastic Nonlinear Analysis of Structures with Under -Tension System (언더텐션 시스템이 적용된 구조물의 비탄성 비선형 거동 해석)

  • Park, Duk-Kun;Lee, Jae-Hong
    • Journal of Korean Association for Spatial Structures
    • /
    • 제9권2호
    • /
    • pp.91-97
    • /
    • 2009
  • This study presents geometric nonlinear and material analysis of under-tension structure using Total Lagrangian and Updated Lagrangian method. In the regard, the under-tension system enables the load of upper part to carry to the end of beam by pre-tensional force in cable. The under-tension system on lower part of the structure is applied in order to reduce the deflection and size of member. This study is performed with conforming of the effect by pretension value in the cable and applying loading. Dead and Live loads are supposed to apply nodal on the top member. The member force and deflection of the structure are with MIDAS and ADINA.

  • PDF