• Title/Summary/Keyword: 입체 현미경

Search Result 83, Processing Time 0.024 seconds

A study of the distribution of glass particles on patrol car seats (순찰차량 시트에서 유리조각의 분포 연구)

  • Kim, Mihye;Ko, Gangseok;Kim, Sookyung;Hong, Sungwook
    • Analytical Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.136-141
    • /
    • 2016
  • In the present study, the distribution of glass particles inside 10 patrol cars of Chungnam Province has been studied. The target seats were front seats (driver’s seat, passenger’s seat) and the back seat. The target areas were the bottom of the seat (seat contacting buttocks, back of the seat, and the corner of the seat (the bottom and back attached part)). The target areas were tape lifted with an adhesive tape. The glass particles adhering to the adhesive tape were examined and counted under a stereomicroscope. The total number of glass particles found was 679. Among them, 471 (driver’s seat 293, passenger seat 178) were collected from front seats, which are usually occupied by police officers. The majority of glass particles were under 0.49 mm size. The results show that the majority of glass particles can be found on the front seats, rather than on the back seat. There is a high probability that glass particles found on the front seat adhere to police officers, so that to get further transferred to the convict upon physical contact (secondary transfer). Thus, there is a risk of misinterpretation of the value of glass evidence in the course of forensic examinations. Hence, a separate method to prevent cross contamination has to be prepared by police authorities as soon as possible.

Comparison of pigment in automotive solid color paints by FT-IR and XRF spectroscopy for forensic aspect (법과학적 관점에서 FT-IR과 XRF를 이용한 단색 페인트의 안료 비교)

  • Park, Ha-Sun;Kim, Ki-Wook;Heo, Sangcheol;Ryu, Seung-Jin;Lee, Hyunik;Min, Ji-Sook
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.245-255
    • /
    • 2013
  • Identification of paint on victim's clothing and a vehicle are valuable for forensic examination when investigating hit-and-run accidents. Automotive paints on clothes are used to prove a victim caused by traffic accident and to identify a suspected vehicle. The comparison of transferred paints between victim's vehicle and suspected vehicle can be an important evidence in reconstructing the accident situation and in discovering the truth. The paints such as white, yellow, red, blue, or black are hard to examine particle shape under a stereomicroscope because of it is not included aluminum, pearl, and mica flakes in the pigments. The aim of this study under forensic aspect is to compare pigment among basecoat layers of solid paints by identifying inorganic elemental compositions and binder resins of pigments using by micro-FT-IR and micro-XRF spectrometer. The pigment samples were analyzed by using two methods of FT-IR: Reflectance and ATR method. Two methods of FT-IR were useful in discriminating binder resins of pigments by comparing characteristic peaks and patterns of spectra. Also, XRF spectrometer could identify the elemental compositions in inorganic pigments of trace paints which are difficult to compare the identification by FT-IR.

MICROLEAKAGE OF 2-STEP ADHESIVE SYSTEMS IN DIAMOND-PREPARED CAVITY (다이아몬드 기구로 삭제한 와동에서 2단계 접착제의 미세누출 비교)

  • Lee, Myung-Goo;Cho, Kwon-Hwan;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.437-444
    • /
    • 2007
  • The purpose of this study was to compare the marginal microleakage of different 2-step adhesive systems in Class V cavities prepared with different diamond points. Forty Class V cavities were prepared with two different (coarse or fine) diamond points on cervical third of extracted molars. The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. They were divided into one of four equal groups (n = 10) and ; Group 1-prepared with coarse diamond point (EX-41), restored with Single Bond and Z 250, Group 2-prepared with fine diamond piont (TF-21F), restored with Sing)e Bond and Z 250, Group 3-prepared with coarse diamond point (EX-41), restored with Clearfil SE Bond and Clearfil AP-X, Group 4-prepared with fine diamond point (TF-21F), restored with Clearfil SE Bond and Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. In this study, marginal microleakage or Single Bond was not affected by type of diamond points. But Clearfil SE Bond showed higher marginal microleakage at both enamel and dentinal margin when Class V cavity was prepared with coarse diamond point.

Blackeye Cowpea Mosaic Virus and Cucumber Mosaic Virus Causing Mosaic Disease on Asparagus Bean (Vigna sesquipedalis) in Korea (동부(Vigna sesquipedalis)에 발생하는 Blackeye Cowpea Mosaic Virus와 Cucumber Mosaic Virus에 관한 연구)

  • Yoon Tae Kyu
    • Korean Journal Plant Pathology
    • /
    • v.3 no.4
    • /
    • pp.291-298
    • /
    • 1987
  • Samples showing mosaic symptom of cowpea (Vigna sesquipedalis) with vein banding, chlorotic spot, vein yellow were collected from Chinju areas in Korea, Two viruses were distinguishable by stability in sap, host range, and relations with cells and tissues were examined under an electron microscope, Blackeye cowpea mosaic(BICMV) was sap-transmissible to 7 plant species in 2 families, Of the plants, only leguminous species were systemically infected. This virus was inactivated by heating at $50-65^{\circ}C$ for 10 min, by diluting at $10^{-4}-10^{-5}$, and aging at room temperature for 1-6 days. Preparations examined under the electron microscope by direct negative staining method(DN -method) always showed particles of flexuous filament bout 750nm in length and cytopasmic inclusions. Cytoplasmic inclusions and virus particles were also confirmed to present in the cytoplasm of a mesophyll cell by ultrathin sections of BICMV infected cowpea leaves. Cucumber mosaic virus (CMV) was transmitted by sap- inoculation on inoculated leaves of Chenopodium amaranticolor, C. quinoa producing local lesions, but non-inoculated upper leaves of Nicotiana glutinosa, Cucurbita pepo and Vigna sesquipedalis producting systemic mosaic symptoms. Electron microscopic examination of virus preparation by direct negative staining showed spherical particles of about 30nm in diameter. In ultrathin sections of CMV infected tissues, virus particles of crystalline array were found in the vacuole and a large number of virus particles were found in the cytoplasm and the plasmodesmata of mesophyll cells.

  • PDF

MICROLEAKAGE OF 7TH GENERATION BONDING SYSTEM (7세대 결합제의 미세누출에 관한 연구)

  • Lee, Sang-Yup;Kim, Dae-Eup;Ra, Ji-Young;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.422-428
    • /
    • 2006
  • Dentin bonding system have recently been developed in an effort to simplify and shorten bonding procedure. The intent of this study was to evaluate microleakage of newer generation of dentin bonding system comparing with other generations. Forty extracted human premolar teeth were randomly assigned to four groups for bonding : the 4th generation bonding system (Scotchbond Multi-Purpose). the 5th generation bonding system (Clearfil SE Bond), 6th generation bonding system (AQ bond) and 7th generation bonding $system(i-bond)^{TM}$ Class V cavities were prepared in buccal and lingual surface. The cavities were restored with composite resin (Z100) after the application of dentin bonding systems according to the instructions of the manufacturer Samples were thermocycled and immersed in methylene blue dye(2%). Each sample was sectioned with Isomet and evaluated for microleakage using stereomicroscopy. The mean value of the microleakage in 7th generation bonding system was greater than those of 4, 5, 6th generation dentin bonding system. Statistically, the mean values of microleakage between 4th and 7th generation bonding system were significantly different from each other (p<0.05).

  • PDF

Effects of direct and indirect bonding techniques on bond strength and microleakage after thermocycling (직접 부착법과 간접 부착법이 열순환 후 부착강도와 미세누출에 미치는 영향에 대한 연구)

  • Ozturk, Firat;Babacan, Hasan;Nalcaci, Ruhi;Kustarci, Alper
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.393-401
    • /
    • 2009
  • Objective: The purpose of this study was to compare the shear bond strength (SBS) of brackets and microleakage of a tooth-adhesive-bracket complex bonded with a direct and an indirect bonding technique after thermocycling. Methods: Fifty non-carious human premolars were divided into two equal groups. In the direct bonding group a light-cured adhesive and a primer (Transbond XT) was used. In the indirect-bonding group, a light-cured adhesive (Transbond XT) and chemical-cured primer (Sondhi Rapid Set) were used. After polymerization, the teeth were kept in distilled water for 24 hours and thereafter subjected to thermal cycling (500 cycles). For the microleakage evaluation, 10 teeth from each group were further sealed with nail varnish, stained with 0.5% basic fuchsin for 24 hours, and examined under a stereomicroscope. Fifteen teeth from each group were used for SBS testing with the universal testing machine and adhesive remnant index (ARI) evaluation. Data were analyzed using the Mann-Whitney U test, Chi-square test, and Fisher's exact test. Results: There were no statistical differences on SBS and microleakage between the two bonding techniques. The indirect bonding group had a significantly lower ARI score. Bracket failures were obtained between enamel-resin interfaces. Conclusions: The type of bonding technique did not significantly affect the amount of microleakage and SBS.

Effect of various casting alloys and abutment composition on the marginal accuracy of bar-type retainer (합금의 종류와 지대주 성분이 바형 유지 장치의 변연 적합도에 미치는 영향)

  • Lee, Yun-Hui;Song, Young-Gyun;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.85-91
    • /
    • 2012
  • Purpose: The object of this study was to determine if the low-priced alloy and metal UCLA abutment could be available for manufacturing bar-retained framework of implant prosthesis. Materials and methods: Bar structure was classified into 4 groups, The specimen of group 1 and 2 were based on casting high noble metal alloys and noble metal alloys with gold UCLA abutment. The specimen of group 3 and 4 were based on casting noble metal alloys and base metal alloys with metal UCLA abutment. Cast bar structure was installed in an acrylic resin model and only the screw on the hexed abutment side was tightened to 20 Ncm. On the opposite side, vertical discrepancy was measured with stereo microscope from front, back, and lateral side of the implant-abutment interface. One-way ANOVA was performed to analyze the marginal fit discrepancy. Results: One-way ANOVA test showed significant differences among all groups ($P$<.05) except for Group 1 and 3. Among them, difference between Group 1 and 2 was noticeable. Measured vertical discrepancies were all below $70{\mu}m$ except to Group 2. Conclusion: Base metal alloy and metal UCLA abutment could be used as an alternative to high-priced gold alloy for implant bar-retained framework.

EFFICIENCY OF ULTRASONIC ROOT-END RETROGRADE CAVITY PREPARATION AND ITS INFLUENCE ON TOOTH STRUCTURE (초음파기구의 치근단 역충전와동형성 효율 및 치질에의 영향)

  • Lee, Jae-Whan;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.546-559
    • /
    • 1997
  • The purposes of this study were to evaluate the efficiency of cavity preparation and to determine the incidence of tooth crack when root-end retrograde cavity preparation was done with ultrasonics. 91 distobuccal root-ends of extracted human maxillary first molars were cut by 3 mm perpendicularly to the long axis of tooth using a slow speed diamond saw, retrocavities were prepared using a slow-speed no. 2 round bur as controls, and stainless steel ultrasonic tips of power settings of 1 through 10 as experimentals. Time consumed and the number of strokes used for the cavity preparation were measured and evaluated, and the incidence of tooth cracks was observed under a stereomicroscope. The results were as follows : For the retrograde cavity preparation, time and number of strokes used were decreased as the ultrasonic power setting increased (p<0.001). High power setting of ultrasonics induced significantly more tooth cracks than did the slow-speed bur or low- and medium power setting of ultrasonics (p<0.05). Teeth with previous crack induced significantly more tooth cracks than those without previous one when high power setting of ultrasonics were used for the retrograde cavity preparation (p<0.001). Teeth with initial apical canal size of no. 10 induced significantly more crack than did those with size of no. 15 when low power setting of ultrasonics were used for the retrograde cavity preparation (p<0.05).

  • PDF

EFFECT OF BISCOVER ON THE MARGINAL MICROLEAKAGE OF COMPOSITE RESIN RESTORATION (복합레진 수복물의 변연 미세누출에 관한 BiscoverTM 전색제의 효과)

  • Cho, Young-Gon;Choi, Hee-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.355-362
    • /
    • 2005
  • The purpose of this study was to compare the effect on marginal leakage of a resin surface sealant (Biscover) applied before or after polymerization of composite resin to unsealed composite restorations. Thirty Class V cavities with the occlusal margin in enamel and cervical margin in dentin or cementum were prepared on the buccal surfaces of sound extracted molars and restored with a microfilled light-cured composite resin (Micronew). Restorations were randomly assigned into one of three equal groups (n = 10): a control group - no surface sealing, group 1 - applied Biscover after polymerization of the composite resin. and group 2 - applied Biscover before polymerization of the composite resin. Specimens were thermocycled, immersed in a $20\%$ methylene blue solution for 4 hoots, sectioned longitudinally, and analyzed for leakage at the occlusal and gingival margins. The results of this study were as follows 1. In sealed group, group 2 showed higher microleakage than group 1 at both occlusal and gingival margins. but there was no significant difference between two groups (p > 0.05). 2. Unsealed control group showed a little higher microleakage than sealed group at occlusal margins, and a little Higher or similar microleakage than sealed group at gingival margins (p > 0.05) 3. Control group and group 2 showed significantly less microleakage at the occlusal margins, but group 1 showed no significantly difference between microleakage at the occlusal and gingival margins.

A Comparison of shear Bonding Strength with Polyacrylic acid and Phosphoric acid Enamel Surface Conditioning (폴리아크릴산과 인산으로 법랑질표면 처리후 전단결합강도의 비교)

  • Roh, Joung-Sub;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.51-57
    • /
    • 2002
  • The purpose of this study was to compare in vitro shear bonding strength with three different enamel surface preparations (1) 30% sulfated polyacrylic acid with 0.3M lithium sulfate (2) 40% sulfated polyacrylic acid with 0.3M lithium sulfate (3) 37% phosphoric acid. 105 extracted human premolar teeth were divided into each three groups of 35. Metal brackets were bonded to teeth in the three groups. The same self curing resin was used for all groups. A shearing force was applied to the teeth. After debonding, bases of bracket and enamel surfaces were examined under steroscopic microscope to determine the failure modes. Statistical analysis of the data was carried out with one way ANOVA and Student t- test. The results were as follows. 1. Shear bond strength values for the 30% polyacrylic acid and 40% polyacrylic acid group were approximately two thirds of the phosphoric acid group. It maintains clinically acceptable but not enough bond strength. 2. There was no statistically significant difference in shear bond strengths between 30% and 40% polyacrylic acid group. 3. The failure modes of brackets had some differences. In polyacrylic acid groups, the percentage of adhesive/enamel failure was higher than that of adhesive/ bracket interface failure. On the contrary in phosphoric acid groups, the results were reversed. Further study of bond strength could be required. If polyacrylic acid enamel conditioning is used clinically.